| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC 37 TILAK NAGAR MATHURA 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹7.9 L+₹1.4 L (21.1%)Rejected-AOC 154 155 SUBATHU DISTT SOLAN 173206 | SOLAN | SOLAN | HIMACHAL PRADESH | 173206 | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹7.9 L+₹1.4 L (21.7%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹8.6 L+₹2.1 L (32.3%)Rejected-AOC | L4 | Rejected-AOC Other than lowest bidder |
| Sl No | Description | Qty | Unit | M/S SUKHMANI ENGINEERS L3 | M/s A.K. ENGINEERS L1 | J B ELECTRICALS L4 | M/S PARMOD KUMAR L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | S&F in repair of switch piano flush type 6 Amps SP one way, Complete all as specified and Directed by Engr-in-Charge. | 100 | Each | 20 ₹2,000 Lowest | 20 ₹2,000 Lowest | 23 ₹2,300 | 20 ₹2,000 Lowest |
| 2.00 | S&F in repair of switch piano flush type 6 Amps SP 2-way, Complete all as specified and Directed by Engr-in-Charge. | 5 | Each | 27 ₹135 | 25 ₹125 Lowest | 35 ₹175 | 35 ₹175 |
| 3.00 | S&F in repair bell push, flush type 6 Amps, Complete all as specified and Directed by Engr-in-Charge. | 5 | Each | 37 ₹185 | 30 ₹150 Lowest | 35 ₹175 | 35 ₹175 |
| 4.00 | S&F in repair of socket outlet 6 Amps flush mounted piano type 5 pin multi purpose, Complete all as specified and Directed by Engr-in-Charge. | 50 | Each | 102 ₹5,100 | 60 ₹3,000 | 55 ₹2,750 | 50 ₹2,500 Lowest |
| 5.00 | S&F in repair of switch piano type 16 Amps SP one way, Complete all as specified and Directed by Engr-in-Charge. | 50 | Each | 85 ₹4,250 | 80 ₹4,000 Lowest | 100 ₹5,000 | 110 ₹5,500 |
| 6.00 | S&F in repair of socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type, Complete all as specified and Directed by Engr-in-Charge. | 100 | Each | 93 ₹9,300 | 80 ₹8,000 Lowest | 100 ₹10,000 | 100 ₹10,000 |
| 7.00 | S&F in repair of lamp holder bakelite insulated body with back plate suitable for batten fitting, Complete all as specified and Directed by Engr-in-Charge. | 50 | Each | 38 ₹1,900 | 40 ₹2,000 | 55 ₹2,750 | 30 ₹1,500 Lowest |
| 8.00 | S&F in repair of bell Ding dong type 230 volts single phase, Complete all as specified and Directed by Engr-in-Charge. | 5 | Each | 180 ₹900 | 160 ₹800 | 150 ₹750 Lowest | 300 ₹1,500 |
| 9.00 | S&F in repair ceiling rose surface Bakelite 65x25 mm two to three terminals, Complete all as specified and Directed by Engr-in-Charge. | 100 | Each | 35 ₹3,500 | 25 ₹2,500 Lowest | 55 ₹5,500 | 35 ₹3,500 |
| 10.00 | S&F in repair LED Glass Bulb 9 Watt B-22 Cap, AC 230V, 50 Hz, suitable for Batten Holder/Bulk head/wall light fittings, Complete all as specified and Directed by Engr-in-Charge. | 150 | Each | 45 ₹6,750 | 40 ₹6,000 Lowest | 100 ₹15,000 | 75 ₹11,250 |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
8 Jan 2026, 6:00 pmClosed
Sh K K Soni AE (Civ) AGE I R and D Manali
AGE I R AND D MANALI PIN 175103 PH 01902255014
REPAIR/MAINT OF LED FITTINGS, BUILDING SECURITY LIGHTS, SUBMAIN WIRINGS, DBs AND CONNECTED ACCESSORIES AT DGRE UNDER AGE (I) R AND D MANALI
2025_MES_745426_1
AGE(I)/MNL-82/2025-26
Open Tender
Civil Works
Item Rate
180 days
Manali
As per NIT and tender documents
5 documents required · 5 mandatory
₹500
AGE (I) R AND D MANALI
₹19,800
Yes
2 Feb 2026
20 Dec 2025
10 Jan 2026
20 Dec 2025
8 Jan 2026
3 Jan 2026
Amount
S&F in repair of switch piano flush type 6 Amps SP one way, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair of switch piano flush type 6 Amps SP 2-way, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair bell push, flush type 6 Amps, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair of socket outlet 6 Amps flush mounted piano type 5 pin multi purpose, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair of switch piano type 16 Amps SP one way, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair of socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair of lamp holder bakelite insulated body with back plate suitable for batten fitting, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair of bell Ding dong type 230 volts single phase, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair ceiling rose surface Bakelite 65x25 mm two to three terminals, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair LED Glass Bulb 9 Watt B-22 Cap, AC 230V, 50 Hz, suitable for Batten Holder/Bulk head/wall light fittings, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair Decorative wall light bracket made up of high grade engineering plastic material suitable for 9 W LED lamp B22 base design approved by engr in charge, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair LED Bulk head 10 watt integrated type complete with LED and 3 core flexible connecting wires, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair LED Batten T-5 fitting 20 watt LED White, indoor decorative aluminum extruded T5 LED battern -integrated type environmental friendly, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair of LED Integrated Batten T5 10 watt - 2FT, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair Circuler Hylam/PVC Sheet upto 10 Cm dia of 3 mm thick (for using as Junction box Cover) including screws and cup washer, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair of PVC casing caping of size 25mm with suitable size of nails for fixing PVC casing caping, in repairs of batten/surface wiring, Complete all as specified and Directed by Engr-in-Charge.
M&L for submain wiring of two runs of 4 Sqmm size for main cable and one run of 4 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn through existing steel/PVC conceiled/surface conduit of size 25mm dia with all fittings accessories including taking down of old unsv submain wiring, Complete all as specified and Directed by Engr-in-Charge. Note :- New conduit of suitable size with connected fitting will be laid if there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes including making good to disturbed surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
M&L for submain wiring of two runs of 6 Sqmm size for main cable and one run of 6 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn through existing steel/PVC conceiled conduit of size 25mm dia with all fittings accessories including taking down of old unsv submain wiring, Complete all as specified and Directed by Engr-in-Charge. Note :- New conduit of suitable size with connected fitting will be laid if there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes including making good to disturbed surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
S&F in replacement MCB DB SPN 4 Way double door type,(IP 43 Protection) flush mounting, Complete all as specified and Directed by Engr-in-Charge.
S&F in replacement MCB DB SPN 8 Way double door type,(IP 43 Protection) flush mounting, Complete all as specified and Directed by Engr-in-Charge.
S&F in replacement MCB DB SPN 12 Way double door type,(IP 43 Protection) flush mounting, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair Recessed mounting 36 Watt 2'x2' flat LED panel fitting luminaire to enhance the delight of occupants with comfortable experience through its classic design and glare & Flicker free illumination. White powder coated CRCA housing with seamless front frame with flat non-yellowish diffuser to fix in existing POP including cutting/grouting of existing POP and get electrically connected the fitting with switch board for suitable size of PVC copper wire, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair Recessed mounting 36 Watt 1'x4' flat LED panel fitting luminaire to enhance the delight of occupants with comfortable experience through its classic design and glare & Flicker free illumination. White powder coated CRCA housing with seamless front frame with flat non-yellowish diffuser to fix in existing POP including cutting/grouting of existing POP and get electrically connected the fitting with switch board for suitable size of PVC copper wire, Complete all as specified and Directed by Engr-in-Charge.
S&F in repair for MCB SP 06 to 32 Amps 240 Volts, 10 KA, `C' curve, all as per site requirement and as directed by Engr-in-Charge.
S&F in repair for MCB SPN 40 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement and as directed by Engr-in-Charge.
S&F in repair for MCB SPN 63 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement and as directed by Engr-in-Charge.
S&F in repair MCB TPN/ Isolator 4P from 63 Amps 415 volts, 'C' Series 10 KA as per site requirement and as directed of approved make.
S&F in repair MCB TP 3 Pole from 40 Amps 415 volts, 'C' Series 10 KA as per site requirement and as directed of approved make, Complete all as specified and Directed by Engr-in-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc., Complete all as specified and Directed by Engr-in-Charge.
M&L for point wiring complete for .One light / fan/bell point controlled by one switch SP, one way, 230 volts using stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ MS conduit and including replacement of unserviceable pressed steel terminal boxes of required size with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) and making good to disturbed surface of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as specified and directed by Engr-in-Charge. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes
M&L for point wiring complete for One 3 pin socket outlet 5/6 Amps on same board using stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ MS conduit and including replacement of unserviceable pressed steel terminal boxes of required size with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) and making good to disturbed surface of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as specified and directed by Engr-in-Charge. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes
M&L for point wiring complete for One socket outlet 5/6 Amps on independent board using stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ MS conduit and including replacement of unserviceable pressed steel terminal boxes of required size with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) and making good to disturbed surface of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as specified and directed by Engr-in-Charge. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes.
M&L for point wiring complete for One power socket 15/16 Amp but with cable 2.5 Sqmm for phase & neutral and for earth 2.5 sqmm. using stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ MS conduit and including replacement of unserviceable pressed steel terminal boxes of required size with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) and making good to disturbed surface of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as specified and directed by Engr-in-Charge. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes.
S&F in repair of switch socket combination piano flush type 5 pin, 6 Amps, 230 volts AC all as specified.
S&F in repair of Switch socket combination 2 in 1, 5 pin, 6 and 16 Amp flush type universal,230 volts complete all as specified.
S&F in repair of gangbox for 5 pin 5A switch socket any type complete all as specified & directed.
S&F in repair of gangbox for 6 pin 5/15A switch socket any type complete all as specified & directed.
Preventive maintenance cheking of elect DBs (SPN/TPN/Load line DBs ) switch board such as checking the looses conncetion in MCBs , cutting the burnt cables and reconnecting to MCBs/DBs spare required shall be maintained and paid under relevent items
S&F in repair distribution board vertical triple pole and neutral 4 way, double door for fixing MCCB upto 125 Amps as incommer and MCBs as out goings with metal door and IP 43 Protections and connecting complete all as specified.
M/S PARMOD KUMAR (BID ID -3524750)
M/S SUKHMANI ENGINEERS (BID ID -3524794)
J B ELECTRICALS (BID ID -3524889)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
TenderDocuments822526EM.pdf
Tender Documents • 1.12 MB
BOQ_834690.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .