Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC SUBHASH PALLY WARD NO 3 P O KOKRAJHAR P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM | KOKRAJHAR | ASSAM | 783331 | ₹2.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.3 Cr+₹3.3 L (1.43%)Rejected-AOC SUBHASH PALLY WARD NO 4 P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | ₹2.3 Cr+₹3.3 L (1.43%) | L2 | Rejected-AOC L2 |
| 3 | L3₹2.3 Cr+₹5.4 L (2.36%)Rejected-AOC WARD NO 3 SUBHASHPALLY P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | ₹2.3 Cr+₹5.4 L (2.36%) | L3 | Rejected-AOC L3 |
Tender Value
₹2.3 Cr
EMD Value
₹4.5 L
Closing Date
9 Jan 2020, 2:30 pmClosed
Sri J.M. Basumatary
O/o the Addl. Chief Engiineer-cum-Director, PWD, BTC, Kokrajhar.
Construction of R.C.C. 3 three storied provision Office Building of Asstt. Director of Audit L.F Assam, Kokrajhar Circle at Kokrajhar Bagicha, Kokrajhar.
2019_BTC_15626_1
42/ACE/PWD/BTC/2019-20/4
Open Tender
Civil Works - Building
Item Rate
365 days
Kokrajhar
Refer to SBD
6 documents required · 6 mandatory
₹6,800
Principal Secretary, BTC, Kokrajhar
₹4.5 L
Yes
17 Feb 2020
30 Dec 2019
9 Jan 2020
30 Dec 2019
9 Jan 2020
30 Dec 2019
30 Dec 2019 - 9 Jan 2020
Amount
CIVIL WORKS: 1.1 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (b) In hard/ dense soil
1.3(c ) Earth / Sand filling with river sand or silt (predominantly non plastic) by truck carriage including loading and unloading in plinth in layer not more than 150 mm thick including necessary, carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes as may be necessary.
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately). a) In prop. 1 cement : 3 sand : 6 coarse aggregate by volume
2.1.3 Providing and laying 25mm thick damp proof course with cement concrete in prop 1: 1.5: 3 with graded stone agg. Of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
2.2.1 Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level (A) Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N)(b) M20 grade concrete or Prop. 1:1.5:3
(B) In super structure from plinth level up to 1st floor level. (ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. (N)(b) M20 grade concrete or Prop. 1:1.5:3
2.2.3 Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level.
2.2.3 Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 2nd floor level.
2.2.3 Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the Head Room floor level.
3.2.1 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
3.2.1.2 Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.
3.2.1.3 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
3.2.1.8 Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.
3.2.3 Providing form work of 12mm thick Plywood board and removal of the same in edges of slabs and breaks in floors and walls etc. of in-situ reinforced concrete works upto first floor level. (a) Thickness not exceeding 200mm.
3.2.4 Extra for each subsequent floor or part thereof above the 1st Floor level as mentioned in item no. 3.2.1 & 3.2.3(b).
3.2.4 Extra for each subsequent floor or part thereof above the 2nd Floor level as mentioned in item no. 3.2.1 & 3.2.3(b).
3.2.4 Extra for each subsequent floor or part thereof above the Head Room Floor level as mentioned in item no. 3.2.1 & 3.2.3(b).
3.2.5 Extra for each subsequent floor or part thereof above the 1st Floor level as mentioned in item no. 3.2.3(a).
3.2.5 Extra for each subsequent floor or part thereof above the 2nd Floor level as mentioned in item no. 3.2.3(a).
3.2.5 Extra for each subsequent floor or part thereof above the Head Room Floor level as mentioned in item no. 3.2.3(a).
4.1.1 Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
4.1.2 Filling sunken floor with broken jhama brick bats and sand including compacting and supplying of materials complete as specified and directed for all levels.
4.1.3 Extra cost for lifting of brickbats and sand for filling of sunk floor for each subsequent floors above the ground floor as directed and specified.
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (d) In proportion 1:6.
4.1.8 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 115 mm thick brick wall (a) In cement mortar in proportion 1:4. (1 cement:4 sand)
4.1.14(b) Extra for brick walling for each subsequent floor or part thereof above the 1st floor level.
4.1.14(b) Extra for brick walling for each subsequent floor or part thereof above the 2nd floor level.
4.1.14(b) Extra for brick walling for each subsequent floor or part thereof above the Head Room floor level.
5.1.3 40 mm thick cement concrete floor consisting of 25 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 12.5 mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @ 2.75 kg. per square metre of floor area , wearing layer is to be laid in panels including curing etc. complete as directed.
5.7.1.2 Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). (a) Normal range Somany/ Orient/Nitco/Asian Make (ii) Of size 200mmx300mm and above
5.7.2.1 Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) (a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make (ii) Of size 600mmx600mm and above
5.7.3.1 Providing polished SUNROCK-Hi CTS/ MULTIWYN tiles of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (a) SUNROCKHi CTS TILES (ii ) Old Castle (455x455) mm
5.11.1 Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. (A) CERAMIC i)Normal range (Sizes 300 mm x 300mm and above) (a)Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate
6.2.2 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side
B) On fair side b) In cement mortar 1:4
6.2.5 Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
7.3.2 Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 2nd floor level (instead of plastering on walls) including curing complete as directed.
7.3.3 Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to Head Room floor level (instead of plastering on walls) including curing complete as directed.
6.2.6(a) Extra over item no 6.2.1to 6.2.3 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed.
7.4.2 Extra over item no 6.2.1to 6.2.3 for interior plastering above 2nd floor level for every addl floor or part thereof including curing complete as directed.
7.4.3 Extra over item no 6.2.1to 6.2.3 for interior plastering above Head Room floor level for every addl floor or part thereof including curing complete as directed.
6.2.8(b) Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level including curing complete as directed.
7.5.2 Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond 2nd floor level including curing complete as directed.
7.5.3 Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond Head Room floor level including curing complete as directed.
5.1.10 Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
9.1.2 Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (b) With 1st class timber (Bonsum/ Sundi)
9.6.1 Providing and fixing 1st class timber moulded architrave of size 50x20mm to door and window frames with countersunk wood screw,wooden plugs and applying a coat of wood preservative on unexposed surface etc. (a) With Teak wood/Sissu wood.
9.12.1 Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. (b) Non decorative type and block board core. (ii) 35 mm thick
10.2 Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. (I) Plain grill (c ) Fixed to Brickwork/P.C.C/R.C.C.
13.3.2 Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
13.3.4 Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (i) Thickness = 1.5 mm thick
13.4.7 Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
13.9.5 Finishing wall with water proofing weather coat smooth anti-fungal exterior painting of Ace brand of Asian Paints and of required shade on old/new wall surface after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
13.6.3(a) Applying priming coat with ready mixed paint, wood primer (pink) over new wood based surfaces over 100mm in girth/ width after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. (a) With ready mixed paint , Wood primer (pink)
13.6.5(i)(b) Painting two coats surfaces over 100mm in width or grith (excluding priming coat) on new wood and wood based surfaces with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J& N paint/Nerolac paint) to give an even shade including cleaning the surfaces of dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or girth. (b) High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
13.7.2(a) Applying primary coat with ready mixed "red -lead /red-oxide" primer over new steel and other metal surface up to 100mm in width or girth after preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed "red-lead/ red oxide" primer.
Painting two coats Surfaces over 100mm in width or grith (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J& N paint/Nerolac paint) to give an even shade including cleaning the surfaces of dirt, dust and other foreign matter. (i) Surfaces over 100mm in width or girth. (b) High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
15.2.1 Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) 11.2 A Sliding door bolts (ii) 250mm x16mm sliding door bolt.
11.3 B Tower bolt (iii) 200mm x 10mm tower bolt.
11.3.2 (v) 100mm x 10mm tower bolt.
11.4 C(ii) 150 mm door handle.
18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) (a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars
18.9.1 Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, chanels, plates etc., including welding grinding, buffing, polishing and curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with necessary accessories and stainless steel dash fastners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-Charge. (For payement only weight of stainless steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fastners etc. will be considered.
19.2 Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
19.5(ii) Providing 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm drain with brick work in cement mortar in prop 1:5 with half brick thick side walls and 100mm thick C.C. (1:3:6) base over one brick flat soling including 15mm thick cement plaster in prop 1:3 finished with a floating coat of cement slurry as directed with necessary earth work in excavation of foundation trenches and refilling the sides after completion of work as specified.
(25.1) Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering , curing etc. complete including fixing in position as directed. (a) 100mm thick slab
21.2.1 Providing cast in-situ machine driven reinforced cement concrete piles of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings including using of Bentonite solution. (Reinforcement to be measured and paid seperately as per item no. 21.4.1) C) UNIFORM PILE (I) Concret garade M20 ii) Pile dia 350 mm
21.4.1 Extra for using admixture & plasticiser (a) RCC grade M20 iii) Pile dia 350 mm
21.4.1 Extra for boring specified diameter pile in high sub-soil water level requiring use of drilling mud and extra cement (iii) 350 mm dia
21.4.3 Empty boring for specified diameter piles from ground level to cut-off level. c) Pile Dia 450 mm
21.5.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor...etc) (A) TMT bar made of Primary producer (From Primary producer)
21.6.1 Routine test for test loading to 1.5 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
21.6.2 Initial test for test loading to 2 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
23.17 Demolishing R.C.C./ P.C.C. pile head of different diameters carefully without disturbing the remaining portion of the pile including opening out of the pile head to be demolished by excavating the earth upto required depth and clearing the debris as directed.
26.1.1 Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
26.1.2 Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated - with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
26.1.3 Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
26.1.5 Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
11.1.2 Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. 16.1.1 (a) 2 track sliding windows (ii) 5 mm frosted glass
16.1.2 3 (b) Track sliding window (i) 6mm clear glass
11.2.1 Providing, fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section of approved brand with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mm lock rails 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the department at all levels. (i) 6mm clear glass
11.6.7 Providing , fabrication and fixing of structural glazing made out of coloured Anodised aluminium mother frame 6 nos 1.2m each @ 1.819 Kg/m and subframe of 16 nos 0.60 m each @ 0.31 Kg/m of Jindal or equivalent and 5 mm reflective glass of approved shade. The glass to be pasted using structural selicon (DC 995) and weatherseal silicon to be used (DC 789), the structure complete with all accessories as and where necessary.
22.3.1 (A) Supplying, mixing, laying and applying the following waterproofing systems over Raft slabs, Roof slabs, Terraces etc. including curing complete as specified and directed by the Department at all levels.: (i) 1mm thick single coat of Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)/ mixed with cement in the ratio 1:2 as a prime coat. (ii) 3mm thick Polymer modified mortar - Cement sand mortar (in prop 1:3) mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals) @ 15% by weight of cement. (iii) 1mm thick coat of Master Crete M-81 /Dr. Sealkit Sealcrete (Asian Chemicals) mixed with cement in the ratio 1:2 as final coat. (B) Using RHEOMIX 131 OF BASF
22.3.10 Providing and applying over sunken slab etc., two coats of waterproofing slurry prepared with neat cement, water and modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/ RHEOMIX 141 by brush after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately) as specified & directed by the Department complete.
29.2.2 Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (10 kg) BRAND : FIRESTOP / FIREND / FIRE SHIELD
SANITARY WORKS: Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately). 1.1.3. Vitreous water closet squatting pan Indian type W.C Orissa pattern of size 580 x 450 mm a) White i) Parryware make
Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) A) Parryware make a) White (v) Elite S Trap (Cat No.C0297) (inclusive of seat cover)
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) i) Parryware make a) White (vi) Slimline Standard (Cat No.C8297)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. C) Jaquar make a) White (i) Urinal (Cat. No.URS-WHT-0704) with Sensor (Cat. No.SNR-CHR-51097)
Providing fitting and fixing vitreous china squatting plate urinal with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (A) Parryware Make (i) White (Cat. No. C0503)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) 1.13.2 BASIN (without pedestal) (A) Parryware Make (a) White (iii) Tunga Basin 450 x 300 (Cat. No.C0401)
Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately (B) Nirali (x) Grace Plain Large (Bowl Size - 560 x 410 x 215) Glossy
Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. (i) Jaquar Make (a) Continental (Cat.No.ACN-1331N)
Providing, fitting and fixing Liquid soap dispenser and liquid soap container complete as directed and specified. (ii) Agmeco Make (a) Liquid soap container Capsule Type (Cat.No.LSC-0001)
Providing, fitting and fixing CP towel rail complete as directed and specified. (b) Sona make (iii) Towel rail diplomat 600mm long (Cat.No.TR-0605)
Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified. (b) Sona make (i) Towel ring round (Cat.No.TR-06051)
Providing, fitting and fixing Chrome Plated robe hook complete as directed and specified. (b) Agmeco make (vi) Dolfee (Cat.No.DE-00211)
Providing, fitting and fixing Chrome Plated Tumbler and brush holder of Parryware make (Cat. No.C9947) complete as directed and specified.
Providing, fitting and fixing Chrome Plated TOILET PAPER holder complete as directed and specified. (d) Sona make (ii) Toilet paper holder with cover (Cat. No.AL-1002)
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (b) Sona (i) Rupa 32mm (HT/ FT) (Cat.No.WS-0801)
(ii) Rupa 40mm (HT/ FT) (Cat.No.WS-0801)
Providing, fitting and fixing Chrome Plated bottle trap pipe complete as directed and specified. (a) Sona make (i) Pipe for bottle trap 300mm long (Cat. No.BT-0761)
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (ii) 110mm dia. PVC cowel of ISI make
C.P. Grating (ii) 110 mm dia
Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specified.
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Construction of brick masonry septic tank on a bed of 1:3:6 PCC with neat cement inside plaster, necessary RCC works etc complete as directed and specified including excavation, backfilling and diaposal of surplus earth. 100 Users
WATER SUPPLY WORKS: Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipe A. In exposed surfaces or in trenches. (c) 25 mm nominal outer dia pipe
(f) 50 mm nominal outer dia pipe
Concealed pipe with cutting chases & making good the walls (a) 15 mm nominal outer dia pipe
(b) 20 mm nominal outer dia pipe
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (IV) Agmeco brand (iv) Bib Cock Long Body with Flange CAT No.CC 00203/CAT No.CN 00203
(v) Bib Cock Two way with Flange CAT No.CC 00203/CAT No.CN 00203
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (II) Agmeco Brand (a) 15mm dia(Male/ Female )
(b) 15mm dia(Concealed )
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. (III) Agmeco (classic) (a) Flat
Supplying fitting and fixing Chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately) (II) Agmeco brand a) Sink cock casted swivel spout
Supplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately) (I) Essco make (a) Casted shower arm heavy 190mm long with wall flange
Supplying fitting and fixing Telephonic Chrome Plated (C.P.) shower of approved brand as directed and specified. (Pipes will be measured and paid separately) (II) Lauret make (Telephonic hand shower with 1.5 m PVC pipe with hook)
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. (a) 50 mm dia
( C) 25 mm dia
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes (I) 2000 Lt capacity (a) Sintex make
INTERNAL ELECTRICAL WORKS: 2.1 Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.1 Short point upto 3.0 meter length
2.1.2 Medium point upto 6.0 meter length
2.1.3 Long point upto 10.0 meter length
2.2 Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. 2.2.2 Medium point upto 6.00 metre length
2.2.3 Long point upto 10.0 meter length
2.10 Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) 2.4.1 Extra long point up to 15.00 metre. Length.
2.4.2 Extra long point up to 20.00 metre. Length.
2.4.3 Extra long point up to 25.00 metre. Length.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. 2.7.1 With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
2.7.2 With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
2.7.3 With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
2.9 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. 2.9.4 With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
2.9.5 With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
11.26 Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt.
11.17 Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including 20 watts CFL lamp and connection as approved by the Deptt.)as required. [ BH ]
11.32 Supplying and fixing of Call bell ( Buzzer ) including 5/ 6 amp capacity button piano type bell push switch including connection as approved by the Deptt.)as required. [ CB ]
11.12 Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp. [ BK ]
11.28 Supplying and fixing of Frosted glass shade of 100 mm dia (Nominal Size as required.
11.53 Supplying and fixing of Fan box (AKG or equivalent as approved by the Deptt.)with inbuild rod as required.
SB. 8.62 Supplying including fitting and fixing of TV co-axial outlet MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells complete as per direction of department.
SB. 8.63 Supplying with fitting and fixing of RJ-11 Telephone jack MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA)A), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection complete as per direction of department.
SB.10.20 Supplying ,installation, testing & commissioning of 2 pair Unarmoured Telephone Cable through existing conduit in surface/ recess system.
6.1 Supply and fixing 19 mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed system including cutting the wall and making good the same as required:
15.2 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.2.1 ABB, Schneider MG, legrand, Hager make) 15.2.1.4 12 way SPN Double Door
15.8 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.8.1 ABB, Schneider MG, legrand, Hager make) 15.8.1.1. 4 way TPN (4+12) double door
Supplying with fitting and fixing MCCB income and MCB outgoing sheet steel, phosphatised, powder painted single door surface mounting vertical TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar up to 125A and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.21.1 ABB, Schneider MG, legrand, Hager make) 15.21.1.1 4 way TPN (4+12) single door
16.1 Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.2 C Series (Schneider MG, legrand, Hager make) 16.1.2.1 6 to 32A
16.3 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.2 C Series (ABB, Schneider MG, legrand, Hager make) 16.3.1.1 6 to 32A
16.7 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.7.2 100/300mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make) 16.7.2.1 25A
16.6 Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.6.2 C Series (ABB, Schneider MG, legrand, Hager make) 16.6.2.2 40A
16.16 Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt. 16.16.1 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens make) 16.16.1.4 63A
22.7 Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
22.12 Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
22.10 Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
22.13 Extra for using salt (5 K and Charcoal (96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
22.15 Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
22.20 Supplying & laying of following size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
22.25 Supplying & laying of following size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
22.32 Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid G.I. tube having 85 mm dia. single prong at top and 3 mm base plate at bottom complete with fitting & fixing with G.I. nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt.
22.28 Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt.
27.1 Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. 27.1.2 Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS-390 Deco Havells make) [ F ]
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. 27.2.1 Domestic 27.2.1.12 Ventil Air DB 300 mm sweep (Havells make) [ EF ]
27.6 Supplying fitting and fixing of ceiling fan Regulator including connections etc. complete as required complete and as directed by the department. 27.6.2 Electronic StepType
Supplying and fitting fixing of H.T./ M. V. danger plate complete as required and as directed by the department.
Supplying with installation testing and commissioning of Hi -- wall 4 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with indoor and outdoor unit, copper pipe and electrical connection as approved by the Deptt.)up to 5 m between the room unit and out door unit as directed by the department. 29.1.2 1.5 Ton capacity 29.1.2.3 3. Blue Star make) Model 4WAE181YA
Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUS make) 31.2.4 3.0 KVA Automatic Input 120-280 V Out put 200-240 V
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 32.1.2 3 Core A2XWY A2XFY 32.1.2.1 4.00 Sq.mm 3 Core armoured U.G. cable
32.1.2.2 6.00 Sq.mm 3 Core armoured U.G. cable
32.1.3.1 25.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
32.1.3.4 70.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 32.5.2 Core - 3 A2XWY A2XFY 32.5.2.1 4.00 Sq.mm 3 Core U.G. cable in 25mm dia medium duty G.I. pipe
32.5.2.2 6.00 Sq.mm 3 Core U.G. cable in 32mm dia medium duty G.I. pipe
32.5.3.1 25.00 Sq.mm 3&1/2 Core U.G. cable in 40mm dia medium duty G.I. pipe
32.5.3.4 70.00 Sq.mm 3&1/2 Core U.G. cable in 50mm dia medium duty G.I. pipe
32.18 Supplying including installation of cast iron cable marker as specified and directed by the deptt.
Supply including fitting and fixing of 1.1 KV PVC/XLPE cable INDOOR/OUTDOOR end termination Kits (Raychem RPG make) HEAT SHRINK TYPE including all accessories for the following sizes including testing and commissioning as specified and directed by the Deptt. 34.28.3 70.00 -150.00 Sq.mm., 3/ 3.5/ 4 Core cable.
Supplying including fitting and fixing of Hot Dip galvanised arm bracket for installation of luminaries. Header with top cap 300 mm long pipe of thickness 3 with arrangement to fix on pole top with 3 Nos. of bolts. i Armed of required length size 48.3mm out side dia x 3.25mm thick (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezone make) Stiffener plate from arm of the following types : 37.2.2 Single arm bracket 1500mm long for 3m to 10 metre. Poles.
EXTERNAL ELECTRICAL WORKS: 22.7 Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
22.12 Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
22.10 Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
22.13 Extra for using salt (5 K and Charcoal (96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
22.15 Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
22.20 Supplying & laying of following size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
22.25 Supplying & laying of following size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
25.2 Supplying with fitting & fixing of the following integral type street light luminaries complete and consisting of single piece integral epoxy gray powder coated dia cast aluminium housing gasket, pot optic reflector, cast aluminium frame from heat resistance toughened clear glass cover and accessories such as Condenser, lamp Holder, Ballast, lamp etc. in the existing pole including making necessary connection as approved by the Deptt.)with 2× 2.50 sq.mm F.R. multistrand and P.V.C. insulated single core copper cable as specified and directed by the department. 25.2.3 Philips make) Cat No.SRX051 1xSON250W For Lamp 1xSON/SONT250W/ / Wipro make): WST50250 For lamp 1x150W HPSV
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 32.1.2 3 Core A2XWY A2XFY 32.1.2.1 4.00 Sq.mm 3 Core armoured U.G. cable
32.1.2.2 6.00 Sq.mm 3 Core armoured U.G. cable
32.1.3.1 25.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
32.1.3.6 120.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
32.2 Supply and laying of following numbers and size of armoured cable in same trench, PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 32.2.1 1 Core A2XWY 32.2.1.20 4x120.00 Sq. mm. 1 Core armoured U.G. cable
32.5 Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 32.5.2 Core - 3 A2XWY A2XFY 32.5.2.1 4.00 Sq.mm 3 Core U.G. cable in 25mm dia medium duty G.I. pipe
32.5.2.2 6.00 Sq.mm 3 Core U.G. cable in 32mm dia medium duty G.I. pipe
32.5.3.1 25.00 Sq.mm 3&1/2 Core U.G. cable in 40mm dia medium duty G.I. pipe
32.5.3.6 120.00 Sq.mm 3&1/2 Core U.G. cable in 65mm dia medium duty G.I. pipe
32.18 Supplying including installation of cast iron cable marker as specified and directed by the deptt.
34.28 Supply including fitting and fixing of 1.1 KV PVC/XLPE cable INDOOR/OUTDOOR end termination Kits (Raychem RPG make) HEAT SHRINK TYPE including all accessories for the following sizes including testing and commissioning as specified and directed by the Deptt. 34.28.3 70.00 -150.00 Sq.mm., 3/ 3.5/ 4 Core cable.
35.1 Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure. 35.1.1 25 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
36.6 Supplying and fitting fixing of galvanised L.T. T cross arm complete with clamps ,blots, nuts etc. as required and as directed by the department.
36.11 Supplying and fitting fixing of galvanised channel of 100 mm x 50 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
36.14 Supplying and erection of 11 KV Pin insulator (Poly) with G.I.pin, blots and nuts coach screw etc. as required and as directed by the department.
36.16 Supplying and erection of 11 KV Disc insulator (Poly) 45 KN with hard ware fittings etc. as required and as directed by the department.
36.22 Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department.
36.23 Supplying and fixing of 11 KV 150 A D.O. fuse set complete as required and as directed by the department.
36.24 Supplying and fixing of 11 KV 5 KA Lighting arrestor (Poly) set complete as required and as directed by the department.
36.25 Supplying and fitting fixing pole clamp complete as required and as directed by the department.
36.33 Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.
36.34 Supplying, erection and commissioning of the following specification as per IS:2713 : 410 SP hot dip Galvanized Steel tubular pole manufacturing out from electrically welded in 3 (three section having a base plate including providing all required building materials as directed and specified by the deptt. (BANSAL/SRP / Valmont / PARUTHI ENGR make) 36.34.9 410 SP 43 Length of pole = 10.00 metre., Length of sections, Bottom = 5.20 M, Middle = 2.40 M, Top = 2.40 M, Out side dia. & Thickness Bottom = 165.10 x 4.50 mm, Middle =138.70 x 4.50 mm, Top =114.3 x 3.65 mm
Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt. Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 5 HP STAGE 14 to 50 with MCB controlled Submersible motor pump set control panel.
Supplying with fitting and fixing sheet steel cable junction box of size 40cm x 20cm x 15 cm made of 16 SWG thick MS Sheet with provision for hinge door and panel locking arrangement complete painted with 2 coats of metal primer and 2 coats of enamelled gloss paint of approved brand and manufacture to give an even shape including cleaning surface to remove of all dirt, dust and other foreign matter, the box is to be fitted on the bottom section of pole with minimum 165 mm dia 25 mm x 5mm size flat iron pole clamp complete with making necessary connection as directed consisting of the following electrical items. a) 12mm x 2mm x 15cm long 2 strip copper Bus Bar - 1 set b) 6-32 Amp "L" series DP MCB - 1 No. c) 6 amp "L" series SP MCB as outgoing - 2 Nos.
Supply, Fitting Fixing of Shock Treatment Chart
RAISING OF LOW SITE: 1.4 (ii) (Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fee, if any monopoly duty etc.(profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (b) Other than Guwahati city.
Paved Road: 5.7.3.4 Const. of Paved Road complete as per analysis
BOUNDARY WALL WITH IRON GATE: Providing brick boundary wall 1.8m high with Rcc post 250x250 size with 4 nos. of 12mm dia TMT main reinforcement and 6mm dia stirrup @ 150 mm c/c and spacing of post should not be more than 2.4m apart including 15cm thick cement plaster in prop. 1:4 on both faces of 12mm thick 1st class brick wall. The post and brick wall rest on RCC footing and tie beam as per design including painting the wall and iron grill ht. 0.45mm on top of wall
17.11: Supplying fitting and fixing double leaf heavy duty iron gate frame made from 50mmx6mm MS flat.
17.13: Providing rails for plying of rollers of gate made from 50mmx6mm size MS flat.
LIFT WITH ALL ACCESSORIES: Supplying installation, testing and commissioning of Passenger Elevator(KONE make for 3stop(544 K 8 persons) having contract speed of 0.65 Metre/Sec(approx.)mps serving different floor in the existing lift shaft as per detailed specification enclosed and as under Location of the lift- 1.Type & Capacity-Passenger-08 Persons-544Kg. 2.Speed- 0.65 Metre./Sec (approx.) 3.Type of Drive- Variable Voltage Variable Frequency Drive with Microprocessor based Simplex Full Collective Control. 4. Location of Machine Room- Top 5. Available Travel- 7.2 metres. ( Maximum) 6. Serving- Ground Floor to 2nd Floor (0,1,2) 3 Stops 3 Levels 3 Openings 7. Well Size- 1850 mm WideX 1850 mm Deep over the finished surface 8. Power supply- 415 Volts 3 phase, 50 cycles alternating current 10. Auxiliary Required- Single-phase 220 V 50 Cycles alternating current. 11. Cab size (Clear Inside approx.---1300mm wideX1100 mm Deep. 12. Pit Depth--1600 mm 13. Head Room-4800 mm. 14. Car Enclosure- Stainless Steel Car- Hairline Finish. 15. Flooring- PVC Flooring 16. Electric Light- Fluorescent Light Fittings 17. Fan- 300 mm Sweep one number. 18. No of Entrances- One Location - Front. 19. Car Entrance- Centre Opening Stainless Steel Power Door without vision panel. 20. Landing Entrance- Centre Opening Stainless Steel Power Door without vision panel. 21. Clear Opening- 800 mm Wide X 2000 mm High. 22. Indicators-Car & Landings-Direction & Position Indicator. Other Features --Emergency Alarm & Light. Call Registration LEDS . OSG Electronic Switch. Fireman Drive Full Length Infra Red door Safety. KONE Rescue Device.
Sajal Sengupta
Manas Das
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .