| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 LAccepted-AOC | ₹4.1 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹4.7 L+₹59,600 (14.5%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹4.7 L+₹59,600 (14.5%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹5.3 L
EMD Value
₹10,520
Closing Date
30 Mar 2020, 6:00 pmClosed
GE Utility Ambala Cantt
GE Utility Ambala Cantt PIN-133001
Repair Maint of Central Package AC plant and Misc items under GE Utility Ambala Cantt
2020_MES_330746_1
GE(U)/AMB-60/2019-20
Open Tender
Civil Works
Item Rate
180 days
Ambala Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
GE Utility Ambala Cantt
₹10,520
Yes
6 Oct 2020
4 Mar 2020
1 Apr 2020
4 Mar 2020
30 Mar 2020
17 Mar 2020
4 Mar 2020 - 16 Mar 2020
Amount
Descaling the condenser by recommended chemical cleaning agent by soaking method, disconnecting condenser from the system by taking out nuts bolts, studs 2 Nos valves and MS/GI pipe line from both sides cover, cleaning each tube with nylon brush, flushing with alkaline solution connecting back both side cover including replacing leather gasket 4 mm thick suitable for AC plants installed as indicated below :- (a) Condenser at OT MH
(b) Condenser at ICU MH
(c) Condenser at Maternity ward
(d) Condenser at Signal Center
Cleaning of Air cooled Condenser by recommended chemical cleaning agent and with high pressure water machine at following :- (a) Air cooled Condenser at Raina Auditorium
(b) Air cooled Condenser at Cold Storage MH
Descaling the Chiller by recommended chemical cleaning agent by soaking method, disconnecting condenser from the system by taking out nuts, bolts, studs 2 Nos valves and MS/GI pipe line from both sides cover, cleaning each tube with nylon brush, flushing with alkaline solution connecting back both side cover including replacing leather gasket 4 mm thick capacities of condensers suitable for AC plants installed as indicated below :- (a) Chiller at OT MH
(b) Chiller at ICU MH
(c) Chiller at Raina Auditorium
Descaling and cleaning of AHU by recommended chemical cleaning agent by soaking method, disconnecting condenser from the system by taking out nuts bolts, studs 2 Nos valves and MS/GI pipe line from both sides cover, cleaning each tube with nylon brush, flushing with alkaline solution connecting back both side cover including replacing leather gasket 4 mm thick suitable for AC plants installed as indicated below :- (a) AHU at OT MH
(b) AHU at ICU MH
(c) AHU at Raina Auditorium
Dismantling of worn out part of FRP cooling tower of AC Plants, cleaning of water tanks and body of cooling tower to make the cooling tower functional and serviceable in all respect including rectification of minor leakages from the cooling tower with M Seal/adhesive complete all as specified and directed by Eng-in-Charge
Supply & fix in replacement side cover jalli for cooling tower for any capacity of OT/ICU MH as per existing size and pattern all as specified and directed by Engr-in-Charge.
Taking down old unserviceable pipe insulations and M&L insulation the pipe line with 25 mm thick closed cell chemically cross linked fire retradant polyethylene foam instulation of density 30 Kg/Cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C, covered with aluminium faced complete application with rubber based adhesive pidilite SR 998 and 50 mm x 3 mm thick self adhesive tape on both longituddinal and traverse joints complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable duct insulations and M&L insulation the Ducts with 13 mm thick closed cell chemically cross linked fire retradant polyethylene foam instulation of density 30 Kg/Cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C, covered with aluminium faced complete application with rubber based adhesive pidilite SR 998 and 50 mm x 3 mm thick self adhesive tape on both longituddinal and traverse joints complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of V belts B-87
Ditto- but B-90
Ditto- but B-81
Ditto- but B-82
Ditto- but A- 28
Supply & charging of refrigerant gas R-22 in central/package type AC plants after detection & rectification of any leakage in the system by using CO2 gas and flushing the complete system thoroughly with Nitrogen gas including testing and commissioning complete all as direccted.
Description all as per item No. 10 above but R-407
Description all as per item No. 10 above but R-404
Note : (i) Gas to be brought by contractor at site from authhorised dealer/manufracturer in company sealed cylinder. (ii) The unit rate quoted in inclusive of cost of nitrogen gas & Co2 gas required for leakage test & pressure test.
M & L in replacement of liqlid line On/Off valve for AC plant as per existing size. at Raina Auditorium AC plants for 23 TR compressor.
Ditto- OT MH AC plant for 12.5 TR compressor.
Ditto- ICU MH AC plant for 12.5 TR compressor.
Ditto- Maternity MH AC plant for 12.5 TR compressor.
Ditto- Signal center MH AC plant for 12.5 TR compressor.
Supply and fixing of PVC pipe 1.5'' for drainage of water from AC plant.
Checking and testing of complete oxygewn gas supply line for leakage and rectify the same by tighting the joint and minor repairs at OT MH all as directed by Engr-In-Charge.
Supply and fixing of Manifold NRV as per existing make & size/type.
Supply and fixing of Oxygen regulator as per existing make & size/type.
Supply and fixing of isolation valve 22 mm with fiting as per existing make & size/type.
Supply and fixing of alarm 3 line as per existing make & size/type.
Supply and fixing of alarm 4 line as per existing make & size/type.
Supply and fixing of flexible tail pipe as per existing make & size/type.
Supply and fixing of seddle for pipeline on walls as per existing make & size/type.
Suppply and fixing matalic viscos filter in replacement made out of GI wire mesh interspaced with two crimp layers and three flat layers and housed in 2" deep metal frame efficeincy 65% as per exisitng size and pattern AC plant air handling unit make athlete or equilevelent.
Supply and fixing of micro filter of size 500 x 500mm x 300mm (NS) flanged type of G.I construction having media supproted by Aluminium expanded mesh & HDPE mesh on front side having efficiency 99% down to 5 micron i/c dismantling the damage filter etc complete as required. Make : Athlete/Clean Air/Purolator or equivalent.
Note:- Amount of credit of Rs. 2054.00 for retrieved materials as mentioned in Schedule of Credit attached in tender documents in pdf form which will be deducted offline while acceptance of tender.
Esha Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .