| 5 | L5₹20.5 L+₹3.6 L (21.1%)Rejected-AOC 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L5 | Rejected-AOC ok |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
29 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST BAREILLY
OUTSOURCING SERVICES OF 11 KV TAKE OVER POINT AND EXTERNAL ELECTRIC SYSTEM AT MTN DIV AOR UNDER GE WEST BAREILLY
2021_MES_426148_1
8912/C/E8
Open Tender
Civil Works
Item Rate
330 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORYSCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRM
SCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹64,000
Yes
2 Jun 2021
26 Feb 2021
3 Apr 2021
26 Feb 2021
29 Mar 2021
13 Mar 2021
26 Feb 2021 - 12 Mar 2021
60 days
Amount
Outsourcing services for 11 KV TOP comprising of 11KV HT control relay panel, HT VCBs, OCBs, Bus coupler, 11/0.43KV Transformers, Air break switches, LT Panel etc, Maintain and record Voltage, Ampere, Shut down, Break down, Lodging complaint by one skilled electrician and one helper round the clock 24 hours in three shifts 0600hrs to 1400hrs, 1400hrs to 2200hrs and 2200hrs to 0600hrs including Sunday and Holiday including normal maintinance i.e oiling, greasing, tightening of conductors, replacement of PG clamps, tightening of cable joints of OCB panels/VCB Panels of all equipment/plant installled at 11 KV TOP.
Outsourcing services for day to day maintenance of external electric system i.e feeding areas of various sub stations by attending external electric complaints by maintaining all incoming and outgoing HT/LT Feeders, HT/LT OH lines and rectification of any fault occured in the feeder like disconnection of jumpers, breaking of ACSR conductor, disconnection of cable lugs from the panel/transformer, blown out of fuse element, trimming of tree branches, tripping of feeders, and loose connection in the service wires/cables, short circuiting of conductors,fixing of HT joints any type and attending of complaints for No Lights from poles and other type of faults in HT/LT will be attended immediately by one skilled electrician and one helper round the clock 24 hours in three shifts 0600hrs to 1400hrs, 1400hrs to 2200hrs and 2200hrs to 0600hrs including sunday and holiday. The installtion comprises the following lines/equipements in 6 Mtn Div AOR, Bareilly Cantt under GE (W) Bareilly. (i) Transformers 11/.415 KV (ii) 11 KV VCBs/OCBs (iii) HT/LT OH/UG Lines (iv) LT Panels
Important Points : (a) Payment to employed persons strictly to be done directly to AADHAR linked bank account only. The contractor shall submit all documents as per pervailing labour laws as applicable.
(b) Electrician should be holding ''ITI certificate, experience and to be submitted by the contractor duly vertified and attested'' where dispute exists about the operators qualification/ performance will be assessed by Engineer-in-charge. Decision shall be binding on contractor. Electrician/Helper shall posses, police verification certificate.
(c) Electrician/Helper should not be more than 45 years of age and should not be deriving pension from any Govt/semi Govt or public sector undertaking.Any disputes will be at discretion of GE and decision shall be binding on contractor.
(d) Necessary security passes shall be arranged by the supervisor in respect of all personel deployed as per prevaling station rule and regulation.
(e) Contractor shall be responsible for safety, security,cleaning and upkeep of installation as per MES standards for installation.
(f) Duty roster for one month will be prepared in advance and displayed at prominent places in installations to include names, shifts and contact Number etc. No Electrician/Helper shall be employed in continuous shift and duty roster to include one rest/off day per week for each Electrician.
(g) Contractor shall ensure through Electrician for day to day upkeep and check of all substation equipments as per manufacturers instructions and carry out minor repairs i.e tightening of joints,oiling/greasing of equipments,cleaning of equipments all specified and directed.
(h) Log sheet shall be provided by the contractor at installation and shall be maintained and handing/taking between continuous Electrician and Helper/Mate shall be done correctly as per norm of MES.
(j) Emergencies shall be notified to Engr in Charge/JE/MCM. Routine operation should be under supervison of JE/MCM designated by Engr in Charge.
(k) The work also includes cleaning of complete Sub Stns including maintenance of area within the Sub Stations.
(l) Any minor/petty repairs arised in the subject installation shall be rectified by the employed tradesman of the contractor and minimum required toolkit/bag & consumables/minor items shall be provided by the contractor and rates are included in the above quoted rates.
(m) The contractor shall provide First aid box /kit and all safety equipments like discharge rod, safety belt, Hand gloves, Helmet, glasses, rain Coat, Gum bootetc in the installations & rates are included in the above quoted rates.
(n) Electrician / helper engaged on duty should be in proper dress as approved by Garrison Engineer and not be more than the age of 45 years and in a sound health and be capable to do the electric related job.
(o) Contractor should maintain of proper electrical shut down register and issue PTW( permit to work). If any fault occur in sub station should be intimated to concerned JE E/M or AGE E/M immidiatly.
Notes : Contractor shall keep the following aspects in mind while quoting unit rates and rates quoted shall be deemed to be including the following:- (a) Cost of minor parts such as nuts,bolts, pvc connector,ruber gasket etc is deemed to be included in the quated rates. (b) Material required shall be measured & paid separately as given here-in-after. (c) Contractor shall provide all tools and plants and spares such as Ladder, hand gloves required for attending the complaints shall be issued by the contractor at his own expenses.
(d) All the Stationary i.e complaint Register, Job Cards, dockets and other conected register related to the work shall be arranged as per sample approved by GE/Engr-in-charge and to be maintained by the contractor including providing 02 Nos mobile phones are in each team for communication to receive complaints and will be fully responsible for safety and security of their tradesman with out any extra cost to the department. (e) Transport will be provided by the Deptt. for attending the complaints but in case of non availability of Transport due to any reason contractor has to make his own arrangement to attend the complaints. (f) If the complaint of Ext. Elect is not attended within 01 hrs a recovery @ 100 per complaint per hour will be lieved / recovered from the contractor.
Supply only HT Tape roll of size 19 mm x 0.75 mm x 9.15M long ISI Marked.
Supply only LT PVC tape roll ¾ inch size 8 mtr long multicolour ISI marked.
Supply only of fuse wire 5 Amps to 100 Amps
Supply only Aluminium Lugs/connectors of size 16 sqmm
Supply only Aluminium Lugs/connectors of size 25 sqmm
Supply only Aluminium Lugs/connectors of size 35 sqmm
Supply only Aluminium Lugs/connectors of size 50 sqmm
Supply only Aluminium Lugs/connectors of size 70 sqmm
Supply only Aluminium Lugs/connectors of size 95 sqmm
Supply only Aluminium Lugs/connectors of size 120 sqmm
Supply only Aluminium Lugs/connectors of size 150 sqmm
Notes:- (a) In case the required technician as mention in relevant items of schedule 'A' is not engaged/found absent, neccesarry recovery to this effect based on double the quoted rate will be recovered from the contractor
RAZA ENTERPRISES
R.S ENGINEERING TRADERS
sunder and company
R. S. Associates
D K THUKRAL AND SONS
Ishtiaq and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .