Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC ANUGRAH H MANGOTTUPARAMBA PUTHIYANGADI EDAKKAD PO CALICUT 673005 | KOZHIKODE | KERALA | 673005 | ₹2.7 L | L1 | Accepted-AOC Agreement executed |
| Sl No | Description | Qty | Unit | BRIJESH L1 |
|---|---|---|---|---|
| 1.00DETAILED ESTIMATE | ||||
| 1.00 | OD21917/2025-2026:Removing the blocked materials from the sullage water drain around the building and depositing the dirty matters to a safe distant place. within a distance of 150 M etc, complete, including cleaning the drain uprooting the vegetation and all labour charges etc. complete, as per the direction of departmental officers at site. | 155 | metre | 345.7 ₹53,583.50 |
| 1.00 | OD21910/2025-2026:Removing RCC covering slab of Manhole and bailing out water by bucket, removing all the dirty matters and depositing in trench near the manhole filling with water and testing the lines and replace the covering slab etc.complete | 11.25 | cum | 1,861.21 ₹20,938.61 |
| 1.00 | OD21915/2025-2026:Engaging sewer man labour for cleaning Septic tank /Drainage similar miscellaneous works etc | 8 | Day | 973.13 ₹7,785.04 |
| 1.00 | 50.14.1.1:Removing and refixing door shutters after necessary repairs for easy opening and closing etc complete as per the direction of site Engineer-in-charge. | 4 | each | 421.87 ₹1,687.48 |
| 1.00 | OD21914/2025-2026:Repairing the existing wash hand basin by replacing the damaged pillar tap pillar cock, PVC connection etc. and testing the water flow, cleaning the basin etc. complete including all cost and conveyance of all materials, all labour charges etc. complete as per the direction of departmental officers at site. | 4 | each | 1,355.19 ₹5,420.76 |
| 1.01 | 50.18.9.13.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall | 25 | metre | 282.38 ₹7,059.50 |
| 1.01 | 50.18.9.14.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall | 20 | metre | 336.2 ₹6,724 |
| 1.01 | 50.18.9.15.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 10Kgf/cm2- External work- Exposed on wall | 20 | metre | 429.09 ₹8,581.80 |
| 1.01 | 50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall | 20 | metre | 384.51 ₹7,690.20 |
Tender Value
₹2.7 L
EMD Value
₹6,775
Closing Date
24 Dec 2025, 3:00 pmClosed
The Asst. Executive Engineer
O/o The Asst. Executive Engineer, PWD Buildings Subdivision, Kozhikode
GENERAL-Running Contract 2025-26 to Womens and Childrens Hospital Kozhikode- Annual maintenance and repair of all kinds of work-General Civil Work
2025_PWD_819672_2
PWD/BLDG/TR/8008/2025_5_1_1/1
Open Tender
Civil Works - Buildings
365 days
kozhikode
Please refer Tender documents.
8 documents required · 8 mandatory
₹600
Yes
₹6,775
Yes
3 Jun 2026
17 Dec 2025
26 Dec 2025
17 Dec 2025
24 Dec 2025
17 Dec 2025
Amount
DETAILED ESTIMATE
OD21917/2025-2026:Removing the blocked materials from the sullage water drain around the building and depositing the dirty matters to a safe distant place. within a distance of 150 M etc, complete, including cleaning the drain uprooting the vegetation and all labour charges etc. complete, as per the direction of departmental officers at site.
OD21910/2025-2026:Removing RCC covering slab of Manhole and bailing out water by bucket, removing all the dirty matters and depositing in trench near the manhole filling with water and testing the lines and replace the covering slab etc.complete
OD21915/2025-2026:Engaging sewer man labour for cleaning Septic tank /Drainage similar miscellaneous works etc
50.14.1.1:Removing and refixing door shutters after necessary repairs for easy opening and closing etc complete as per the direction of site Engineer-in-charge.
OD21914/2025-2026:Repairing the existing wash hand basin by replacing the damaged pillar tap pillar cock, PVC connection etc. and testing the water flow, cleaning the basin etc. complete including all cost and conveyance of all materials, all labour charges etc. complete as per the direction of departmental officers at site.
50.18.9.13.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall
50.18.9.14.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall
50.18.9.15.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 10Kgf/cm2- External work- Exposed on wall
50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
OD21913/2025-2026:Supplying and fixing PVC ball valve of approve quality, 40 mm nominal bore
50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
18.51.1:Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
18.54.3:Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal bore, 165 mm long, weighing not less than 110 gms
OD21911/2025-2026:Engaging labour for miscellaneous plumbing works as per the direction of Engineer in charge.
15.31:Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
14.15.1:Renewing wooden battens in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete, including removal of rubbish to the dumping ground, all complete asper direction of Engineer-in-Charge.Sal wood battens
OD21918/2025-2026:Engaging labour for Carpentry works
OD21912/2025-2026:Roofing with Departmental MP clay tiles (manglore tile ) of 20mm nominal thickness and of approved size and as per approved pattern on steel/wood frame work complete (steel/wood frame work to be paid separately)
15.60:Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
15.57:Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
21.5:Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ).
50.12.5.1:Providing and fixing false ceiling with e board classic tile or equivalent make of size 610x610x4 mm ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately)
Bidder Name
BRIJESH
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1378300.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
sbd.pdf
Tender Documents • 1.63 MB
nit.pdf
Tender Documents • 0.03 MB
BOQ_1378300.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid