Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.2 L+₹4,822 (0.17%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹28.7 L+₹58,417 (2.08%)Rejected-Finance D NO 39 12 27 1 3 MURALI NAGAR VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹28.9 L+₹74,864 (2.66%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹30.0 L+₹1.8 L (6.56%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
Tender Value
Refer Docs
EMD Value
₹95,400
Closing Date
30 Jun 2021, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR MAINT OF HT VCBS RMUS TRANSFORMERS HT DISTRIBUTION SYSTEM INCUDING REPAIR CALIBRATION OF RELAYS METERS AND OTHER ALLIED WORKS AT 11KV SUB STATION 9IRSD AREA WED MO V NEW ASHOKA PARK M PETTA NAMAC NSB AND NAUSHAKTI VIHAR UNDER AGE
2021_MES_450077_1
8323
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
CLASS D
10 documents required · 10 mandatory
₹500
Garrison Engineer Utility-I
₹95,400
Yes
8 Sept 2021
10 Jun 2021
2 Jul 2021
10 Jun 2021
30 Jun 2021
23 Jun 2021
Amount
M&L for disconnecting carefully electrical connection from both HT/ LT (primary & secondary) sides of the transformer, keeping them at safe side and taking out the transformer/Voltage stabiliser indoor/ outdoor type of capacity 500 KVA to 630 kVA, 11 KV/ 0.433 KV, step down any make for carrying out complete overhauling which shall comprise of the following:-
a) M&L for lifting, transporting, handling, the transformer to workshop and opening top cover of the transformer by unscrewing nuts, bolts, washers etc. including disconnecting core assembly from HT/ LT bushing and lifting the same gently and taking out from the shell (container/ body) of the transformer.
b) M&L for draining out transformer oil from the above said transformer in the suitable capacity of container /drums and keeping it in safe custody for reuse.
c) M&L for cleaning the transformer body from inside, removing deposited dirt/ sludge/ foreign particles etc. from the bottom/ body of the transformer and drying up the shell from inside before refilling of the transformer oil.
d) M&L for cleaning and washing thoroughly core and windings of the transformer by hosing down with clean dry oil conforming to IS 335/1983, removing deposited dirt/sludge/foreign particles from the windings/ core, thorough inspection of windings, providing insulations to leads and terminals, heating/ drying/ baking complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc. all as directed by Engr-in- charge.
e) Lifting and refixing core assembly inside the transformer shell gently and carefully, connecting primary/ secondary/ Neutral connections to the bushings assembly, fixing of tap change over including tightening of nuts, bolts, washers of the core to reduce humming noise all as directed.
f) Refilling the filtered transformer oil in the shell of transformer complete.
g) Refixing the top cover including replacement of cork sheet/ gasket 8mm thick, tightening of nuts/ bolts/ washers etc. and replacement of breather with silica gel crystal type all as directed by Engr-in charge
h) Lifting/ shifting to the place from where removed or to any location as directed and re-installing the transformer including connecting primary/ secondary/ neutral connections etc. all as directed by Engr-in-Charge.
j) The inspection of transformer shall involve:- i) Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts. Ii) Checking all brazings, joints, tap heads and connection joints. iii) Checking all jumpers, terminations/ connections inside the transformer. iv) Checking the Buchholz relay/ conservator MOG if any. v) Painting of transformer complete with two coats of synthetic enamel paint externally transformer shell complete all as directed by Engr-in-Charge. (vi) Inspection of tap changer, checking the moving and fixed contacts for contact wear and connection to winding.
k) Conducting the tests on core and windings as per IS like ratio, magnetic imbalance, short circuit etc. in presence of Engr-in-Charge and test results shall be signed both by the contractor and Engineer -in-Charge and kept on record.
Note:- (i) Any damage to insulators/ bushes/ windings etc. while in the custody of the contractor shall be made good at no extra cost to Department. The serviceability of the transformer shall be checked and confirmed by the contractor before taking into his custody. (ii) M&L for rewinding/ re-insulation of HT/ LT (primary/ secondary) coils, bushes, studs, Transformer oil,cable box, replacement of buchholz relay/ MOG if any etc will be measured and paid separately.
All as per Item No. 1 above but transformer/Voltage stabiliser indoor/ outdoor type of capacity upto 400 KVA
Filtration of transformer oil of transformers/ FRMUs installed at various locations to achieve di-electric strength not less than 60 KV at 2.5mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before filtration and after filtration complete all as directed by the Engineer-in-Charge.
Supply and topping up of transformer oil with di-electric strength not less than 60 KV in to the conservator tank/ body tank of the transformer/ OCB/ FRMUs etc at various locations complete all as directed by the Engineer-in-Charge. [Make: Poweroil/ Transol/ Sabitha Chemicals]
M&L for rewinding of distribution (HT/LT) transformers of capacity ( 50 KVA to 400 KVA)/ type by winding the defective coils with new copper wire as per I.S. of same gauge and existing size together with new insulated materials/ bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the transformer and recording the test results complete all as directed. [Note: M&L for re-insulation of serviceable coils will be measured & paid separately under relevant items.]
M&L for rewinding of distribution (HT/LT) transformers of capacity ( 500 KVA to 630 KVA)/ type by winding the defective coils with new copper wire as per I.S. of same gauge and existing size together with new insulated materials/ bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the transformer and recording the test results complete all as directed. [Note: M&L for re-insulation of serviceable coils will be measured & paid separately under relevant items.]
M&L for re-insulating windings of HT/ LT distribution transformers of capacity ( 50 KVA to 630 KVA) / size/ type by strip opening of HT/ LT coils (i.e. Primary/ secondary coils) from core assembly safely, unwinding the HT/ LT coils (i.e. Primary/ secondary coils) complete, removing the old defective insulation paper and replacing with new DPC insulation to the copper conductor, re-varnishing of the windings with super varnish including heating/ drying/ backing complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc. all as per IS 1986-87 and as directed by Engr-in- charge.
Disconnection of the Distrubution Transformer from HT and LT supply mains, removing of Bus duct and Bus bar, Leakage arresting to following transformers by draining out of oil, after arrangement of necessary empty oil drums, buckets etc.,dismantling of top cover and acessories, dismantling of LT bushings by disconnecting leads/jumpers from inside, replacement of gaskets and oil seals and re fixing of the LT bushings, making internal and external connections, replacement of cover gasket and acessories, refixing of acessories and cover, filling of transformer oil complete, and making cable connections and assesting for energising the transformer. (Cost includes materials like gaskets and oil seals and labour, the Bushing and bushings rods to be measured and paid separately).
(a) 500 kVA to 630 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 kVA
Disconnecting the HT/LT connections of following transformers i.e (Bus duct / Cable bunch) keeping all the cables out from the HT/LT sides, physically checking the transformer for healthyness, performing the transformer tests like Meggar test, Ratio Test, Magnetic Balance test and short circuit tests for checking the condition of transformer complete and test results shall be submitted by the contractor. Note:- (i) If the transformer found satisfactory then HT/LT connections shall be done by the contractor and has to charge the transformer. (ii) If the transformer fails in these tests then the contractor has to shift the transsformer for winding /overhauling. (iii) Cost of Transportation / winding / overhauling is exclusive of rate quoted by the
(a) 500 kVA to 630 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 kVA
Shifting the Transformer from existing site to another site within 3 Km distance range by Dismantling of HT and LT cables, jumpers and busbars including LT busbar cable boxes and close the transformers for loading in to Vehicle with the help of crane, transportation to another site, unloading, cable connections both HT and LT, testing and commissioning.
(a) 500 kVA to 630 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 kVA
M&L for replacement of Silica gel breather assembly complete with breather unit and silicagel including connecting with proper necessary gaskets if necessary, including removing the unserviceable breather assembly.
(a) 500 kVA to 630 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 kVA
Supply and filling Silica gel to the transformer breather of transformer including removing the unserveiceable silica gel
M&L for replacement of of Conservator tank complete unit and including connecting with proper necessary gaskets if necessary, including removing the unserviceable Conservator tank:
(a) 500 kVA to 630 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 kVA
M&L for replacement gun metal drain valves of transformers of following capacities including dismantling old one . MAKE :- UPADHYAY/ LEADER/ ZOLOTO/ VAG
(a) 500 kVA to 630 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 kVA
Supply and fix in repairs off load tap changer assembly suitable for any make with 7 tapping position including opening top cover, conservator etc.
(a) 500 kVA to 630 kVA
(b) uto 400 KVA
Supply and replacement of (WTI) Winding Temperature Indicator of following distribution transformers including dismantling old one
(a) 500 kVA to 630 kVA
(b) uto 400 KVA
Supply only LT Bushings made out Porcelain and suitable length/size all as per existing, complete the following capacity distribution transformers of any make/size/type all as directed including dismatling old one.
(a) 500 kVA to 630 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 kVA
Supply only HT Bushings made out Porcelain and suitable length/size all as per existing, complete the following capacity distribution transformers of any make/size/type all as directed including dismatling old one.
(a) 500 kVA to 630 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 kVA
Supply only LT Bushing rod made out of Brass/Copper with threading and suitable length/size all as per existing metal parts / bolts etc, complete the following capacity distribution transformers of any make/size/type all as directed including dismantling old one.
(a) 500 kVA to 630 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 kVA
Supply only LT Bushing rod made out of Brass/Copper with threading and suitable length/size all as per existing metal parts / bolts etc, complete the following capacity distribution transformers of any make/size/type all as directed including dismantling old one.
(a) 500 kVA to 630 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 kVA
M&L for replacement of (OTI) Oil Temperature indicator of following distribution transformers including dismantling old one.
(a) 500 kVA to 630 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 kVA
M&L for providing new cable box made out of MS sheet of thickness not less than 3.15 mm including fabrication works, welding etc. to suit the LT/HT side of existing transformer size, including nuts, bolts, cable glands, termination of existing cables etc., all as directd by the Engineer-in-charge for the following capacity transformers:
(a) 500 kVA to 630 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 kVA
M&L for replacement of Drain plugs to valves/conservator caps of the sizes 3/4", 1", 1.5" valves and plugs of the following capacity distribution transformers of any make/size/type all as directed including dismantling old one.
(a) 500 kVA to 630 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 kVA
M&L for replacement of Oil gauge glass with gaskets of the following capacity distribution transformers of any make/size/type all as directed including dismantling old one.
(a) 500 kVA to 630 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 kVA
M&L for preparation of old painted surfaces of transformers with coarse cloth/ brush and painting throughout externally on exposed surfaces with two coats of smoke grey colour synthetic enamel paint including writing of transformer details on plinth in white enamel paint on black enamel paint back ground complete including one coat of white wash for base foundation all as specified and directed by Engineer-in-charge for the following capacity in-door/ out-door type transformer:-
(a) 500 kVA to 630 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 kVA
Clearing of bushes/small plants upto root level around and surroundings areas E/M installations (i.e.Two Pole/ Four structures, outdoor-substation yards, pump house & Misc E/M installations etc) including surface dressing n.exc 15 cm deep and removing debris to a distance n.exc 50m complete all as specified and as directed
Excavation in trenches n.exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in Soft/loose soil complete all as specified and as directed
Returning and filling in of excavated material ay type including spreading,levelling,watering and well ramming in layers not exceeding 25 cm each complete all as specified and as directed
Removal of surplus excavated material of any type not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed
M&L for Sand cushioning/sand covering for underground cable protection complete all as specified and as directed Note: Punned thickness only will be measured and paid.
Supplying and laying reinforced precast concrete cable cover, class HV, Type 1, flat, size 300 mm x 180 mm x 40 mm, laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
M&L for GI pipe light grade 100 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection .complete all as specified and directed
M&L for cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 120 to 185 Sqmm including testing after jointing complete all as specified and as directed. Make: M-Seal/ 3M/ Raychem/ Denson
M&L for cable jointing kit for 11 KV (Earthed) grade XLPE cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 120 to 185 Sqmm including testing after jointing complete all as specified and as directed. Make: M-Seal/ 3M/ Raychem/ Denson
M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 240 Sqmm including testing after jointing complete all as specified and as directed. Make: M-Seal/ 3M/ Raychem/ Denson.
M&L for cable jointing kit for 11 KV (Earthed) grade XLPE cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 240 Sqmm including testing after jointing complete all as specified and as directed. Make: M-Seal/ 3M/ Raychem/ Denson
Supply , Laying and testing of XLPE insulated,screened, PVC bedded galvanised steel strip or wire armoured ,electric power cables heavy duty with aluminium conductor, 11000 Volts grade ( earthed) of size 3 core 185 Sqmm complete in trenches/ ducts/ on pole etc complete all as directed . Make: Universal/ Nicco/ Polycab/Havells
M&L for detecting HT 11 KV UG cable faults located in any stretch/ depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave reciever, cable indentification instrument , cable tracer for exact location of under ground cable routes. Note: The rate quoted deemed to be inclusive of transportation of equipment and charges for service engineer . The fault locator will be provided by the contractor for operation
M&L for repair and servicing of HT (HT 11 KV) four pole structure by replacing Aluminium PG clamps, GI bolts and nuts, pieces of ACSR conductor with insulation sleeve RYB of any size as jumpers including lubricating the moving parts of AB switch and cleaning of all disc and pin insulators and applying silicon compound for prevention of arcing due to dust/ salt deposits over the surfaces including preparation of surfaces, applying zinc chromate primer on rusted surfaces and applying one coat of aluminum paint to the entire structure complete all as directed. Note:-Rate quoted shall be inclusive of two coats of white wash on exposed concrete .
All as per item No. 39 above but for two pole structure
S & F notice plate of 1.6 mm thick of size 25 x 20 cm , mild steel sheet vitreous enamelled white, with letters figers and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 11 KV complete all as specified and as directed.
M&L for cross arms, bracing, supports, clamps and back plates fabricated from structual steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicted and inclusive of one primer coat one under coat and two finishing coat of aluminium paint including dismatling old one.
M & L for disc insulator porcelain vitreous brown 145 mm height & 225 mm dia ball and socket type two in series assembly with cast aluminium 4 U bolt tension hardware and tension clamps for conductors working pressure HT 11 KV complete including dismatling old one complete all as specified and as directed.
Material for pin insulator porcelain vitreous brown insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut for 11000 volts grade 205 mm dia & 215 mm height, complete including dismatling old one complete all as specified and as directed.
All as per Item No. 44 above but post type insulator including dismantling old one.
Supply and install HT 11 KV, 200 Amp outdoor type gang operated single break switch Tilting type vertical mounting consisting of hot dip galvanised channel iron base having 2 Nos 11 KV Post type insulator in stack and 3 stack per phase copper or copper alloy high pressure heavily tinned contacts plated MS arcing horns capable of breaking the magnetizing current complete with horizontal connecting bar GI pipe as down rod levers coupling & operating handle with locking arrangement complete.
S & Install drop out lift OFF HT 11 KV, 200 Amp fuse link consisting of channel iron base having 2 Nos 11 KV post type insulators in stack & 2 stack per phase complete with fuse carrier of SRBP tube with heavily tinned non ferrous metal parts and spring loaded phosphor bronze contact complete manufactured as per IS 9385 complete all as specified and as directed.
S & F following spares of GOD 11 KV grade, 200 Amp rating in position as in repairs including testing after repairs :
(a). Male contact
(b). Female contact
(c). Tinned copper flexible jumper
(d). MS Jumper carrier
(e). Back connector plate
Supply and laying in repairs rubber mat of Size 2m x lm x 19 mm.
Servicing,Inspecting,checking,cleaning by using of blower,Lubrication ,greasing and carrying out preventive maintanance of RMU capacity 11 KV, 250/350 MVA and RMU in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. Notes: (i) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, HT insulation tape, compound, painting of RMU panels with approved colour including lettering details all as per exisitng etc.
Inspection,testing & servicing,overhauling of HT 11 KV Switch gear and VCBs of capacity 630 to 800 Amps, 11 KV 250 / 350 MVA carried out through Authorised CEIG Licenced agency and comprising of the following all as directed by Eng-in- charge :- (a) Preliminary inspection of 11 KV MV Switch gear for any defects. (b)Testing of CTs:- (i) IR test (ii) Ratio test (iii) Winding resistance test (c) Testing of PTs:- (i) IR test (ii) Ratio test (iii) Polarity test. (d) Servicing on MV Switch gear panels :- (i) Cleaning panel (ii) checking the condition of support insulators and other accessories. (iii) IR test (iv) HV test. (e) Servicing on VCBs :- (i) IR test (ii) Timing test. (iii) CRM test (iv) HV test (f) Over hauling of breakers for proper functionalling (g) Replacement of minor spares.
Notes: (i)The servicing includes for bus bar duct chamber, cable alleys and connecting accessories (ii) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of VCB panels with approved colour including lettering details all as per existing etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. (iii) Major spares like Breaker bushings, vacuum interrupter assly, bus bar spout, bus bar spout connections, circuit spout/circuit spout connections/buffer fixed contacts, moving contacts, tank assly/barriers, solenoid spares, dependent/spring mechanism/ motor mechanism, trip unit etc. will be measured and paid separately under relevant items of Schedule 'A'. However the rate quoted shall be deemed to include for any other minor spares require replacement. (iv)Servicing shall be carried out through authorised OEM service personal only and test report shall be submitted in duplicate. (v) Required new components will be measured and paid separately under relevant items.
Supply & fixing closing coil assembly 110 V DC to Schneider make 11 KV VCB including necessary connection testing complete including dismantling and taking down unserviceable one complete all as specified and directed. Make- Schneider Cat Part No- ECO39SN134900FN
Supply and fixing tripping coil 110 V DC to Schneider make 11 KV VCB including necessary connection testing complete including dismantling and taking down unserviceable one all as specified and directed. Make- Schneider, Cat Part No- ECO39SN134100FN
Supply and fix including dismantling taking out unserviceable vacuum interrupter of suitable for VCB of capacity 2500 Amps all as specified and directed. Make- Schneider Cat Part No-VSLVG4002-01
Supply and fix including dismantling taking out unserviceable Breaker Nylon Wheel, For 800A to 2500A Schneider make 11 KV VCB complete all as specified and directed. Make- Schneider Cat Part No-MVIA00054-01
Supply and fix including dismantling taking out unserviceable spring charging Universal motor with gear box 220V AC For 800A to 2500A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider Cat Part No-MVIJOO157-02
Supply and fix including dismantling taking out unserviceable Release Lever (Nylon ) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider Cat Part No- MVIJ00010-01
Supply and fix including dismantling taking out unserviceable Buffer (For Opening Spring ) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider Cat Part No- MVIJ000980-1
Supply and fix including dismantling taking out unserviceable Buffer (For Closing Spring ) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider Cat Part No- MVIJ00056-01
Supply and fix including dismantling taking out unserviceable Rectifier unit (Monoblock) for spring charging motor For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider Cat Part No- ERC-A-A00DC-001
Supply and fixing of Thermostat and Hygrostat in place of unserviceable damaged space heater, 230V AC supply inside 11 KV HT VCB, cable chamber including dismantling & necessary connection, testing complete all as specified and as directed.
Supply and fix including dismantling taking out unserviceable Service/Test Position Limit Switch 1NO+1NC For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make- Schneider Cat Part No- ESW-B-AAA00-001
S&F multifunctional meter with LED display, accuracy class-1, e- navigator, including dismantling taking down unserviceable one and connection, programming, testing complete all as specified and directed. Make- Elmeasure , L&T , Schneider
Supply and fix including dismantling taking out unserviceable Isolating Contact For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- MVIK00190-01
Supply and fix single (Red-Blue) phase bus bar spout suitable for 800 Amps to 1250 Amps VCB complete al as spec Make Schneider Catpst only Model No MEP-39- 32185 complete all as specified and directed.
Supply and fix single (Y) phase bus bar suitable spout for 800 Amps to 1250 Amps VCB . Make Schneider Model No MEP-39-32186 complete all as specified and directed.
Supply and fix Drive Beam suitable for 11 KV VCB 800 to 2000 Amps. Make Schneider only Model No MCS27S0298700PN complete all as specified and directed.
Supply and fix Epoxy Body suitable for 11 KV VCB up to 1250 Amps. Make Schneider only Model No MEP3953022000FN
Supply and fix Drive Rod assembly with contact block VG2 suitable for 11 KV VCB up to 1250 Amps. Make Schneider or equivalent as approved by GE.
Supply and fix CT Spout suitable for VCB 800 to 2500 Amps 25 Ka chamber insulating bus support epoxy insulator of dia 95mm and 125mm length complete all as specified and as directed. Make Schneider or equivalent as approved by GE.
M&L for setting of 3 phase IED of any type / Make from 11 kV HT panel, cleaning the contacts , IED configuration , Calibration & Testing of all the measuring & protection devices viz., CTs, Relays and Meters at site. Testing of all the trip functions of the relays after final current settings by simulating fault current by CT secondary injection test set , checking of current transformer , rectification of defects in control wiring for proper tripping of CB during actual system fault conduction through relay & Tripping coil. Adjustment / setting to plug and time multiplier settings of IED to achieve the discrimination in tripping , tune/synchronies upstream breaker relay settings-installation of relay, testing & commissioning etc. complete all as specified and as directed.
M&L for Collecting necessary required data & peak load details from IED of any type/Make from 11kV HT panel , Transformer full load details during peak hours. Relay Setting Calculations & Co-Ordination Study. Unit Protection Setting of Transformers. Feeder wise settings has to be furnished & Report with Firm Recommendations to be submitted Down Stream Power distribution (Complete 11 KV system) overall co-ordinations of time need to be achieved. Adjustment / setting to plug and time multiplier settings of IED complete all as specified and as directed.
Maintenance, servicing, Buffing/cleaning, Electroplating of copper Busbar in busbar chamber of each VCB panel including connecting bus bar from CT to main Bus bar & spout. servicing of support insulator by clean cloth and hot air blower/vacuum cleaner, checking for any loose contact, refixing of all nuts & bolts by Stainless Steel , refixing all covers , replacement of defective bus spout complete all as specified and as directed. Note:- Required new components will be measured and paid separately under relevant items.
M & L for applying Si-COAT 570 RTV Silicone High Voltage Insulator Coating solution using an GRACO Mark IV Airless Sprayer to the total VCB panel inside body along with busbars and re-connection of all existing cables, extended bus bars, testing complete all as specified and as directed. Make:- CSL Silicones Inc. Canada or equivalent as approved by GE.
Supply and fixing Resin Cast CT dual core, CT ratio- 100/50/5A-5A For 800A , 11 KV VCB panel complete all as specified and as directed.
M&L for maintenance / servicing of PT unit 11Kv / 110V by disconnecting and taking out from panel mounted position, checking & cleaning of fixed and moving contact points, cleaning/ decarbonising of bus bar connections, resin cast PTs using hot blower, CTC solution, applying backlot (Red) solution to the epoxy PT body, tightening of all nuts, bolts, washers, and refixing the same PT to original position, testing complete all as specified and as directed.
M&L for rectification of faults and retrofit of electrical circuit of 11 KV VCB with suitable IED's by checking CT/PT healthiness , proper programming of multifunctional meters and replacement of defective components & wiring with FRLSH multistrand PVC insulated copper conductor 1100 volts grade as per existing size of wire complete all as specified and as directed. Note :- Required new components will be measured and paid separately under relevant items.
Supply , install ,Testing , Commissioming of Numerical feeder protection relay 50/51N (Earth over current),67 P (3 Ph directional over current),67N (Earth fault directional over current), 51V (Voltage controlled over current), 37 (3Ph under current),46 (Negative Phase sequence over current),59N (Residual over voltage),32 (Directional power protection under/over active/Reactive power),81 (Under over over Frequency ), 49 (Thermal Overload),79 (Auto resue),50BF (Circuit breaker failure direction),Cold pickup,Inrush blocking including taking down old relay complete all as specified and directed by Engr-in Charge.Relay will be on Modbus Protocol. Make:- Schneider of Model Micom P-127 protection relay, 110V, 5A, type-BAOZ112Ca1 or its equivalent in ABB/SEIMENS
Supply and fixing High Speed Master Trip Relay
Supply and fixing the following for METERING:
(c) HRC fuse (PT HT side)
Supply and fixing the INDICATION LAMPS for C.B. ON/OFF/TRIP/Trip Circuit Healthy and Unhealthy/Spring Charged
Supply and fixing the following for CONTROL SWITCHES & Control Wiring
(a) T‐N‐C Switch (Breaker Control Switch)
(b) Trip Circuit Healthy Push Button
(c) Control wiring with appropriate colours
(d) Local Remote switch
Supply and replace 2V, DC, VRLA cell and arrange properly with connecting leads inside battery rack suitable for control DC circuit of 11 KV VCBs and after assembling required voltage is 110V / 100AH including taking down old complete all as specified and directed by Engineer-in-Charge. Make: AMARA RAJA / EXIDE / AMARON
Supply and replace 110v DC/100Ah/30A battery charger made of carbon steel duly grey powder coated finish,contineously weded and ground smooth,concealed door hinges,locking mechanism with key/padlocking handle,oil resistant gasket including taking down old rusted battery cabinet complete all as specified and directed by Engr-in-Charge. Make: AMARA RAJA / EXIDE / AMARON
M/s NATIONAL ENGINEERING CONSTRUCTIONS CO
UNITY PROJEKTZ
GS ENGINEERS
UV POWER TECH
B5BUILDING SOLUTIONS
Saket Enterprises
P NARAYANA RAO
M.V.K.ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .