Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC 27 ABUSETH ROAD DEHU ROAD PUNE 412 101 | NA | NA | 412101 | L1 | Accepted-AOC Accepted as L1 | |
| 2 | L2₹14.8 L+₹2.2 L (17.3%)Rejected-Finance FLAT NO 1 GURUKRUPA APARTMENT BEHIND TELEPHONE EXCHANGE DEHUROAD PUNE | PUNE | PUNE | MAHARASHTRA | 412101 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹17.5 L+₹4.8 L (38.3%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹18.0 L+₹5.3 L (42.2%)Rejected-Finance PR CDA SC PUNE 01 THROUGH AO GE DEHU ROAD | L4 | Rejected-Finance Rejected | |
| 5 | L5₹2.0 L−₹10.6 L (84.2%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
17 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE, Dehu Road, Pune
GE, Dehu Road, Pune
CERTAIN REPAIRS TO SEWAGE LINES MAN HOLES SEPTIC TANKS CLEANING OF SEWAGE LINE OF MDOTM ACCN AT 105 AD REGT 953 WKSP SARVATRA NAGAR SIG COY UNDER AGE BR WEST AT GE DEHU ROAD
2020_MES_397226_1
8486
Open Tender
Civil Works
Item Rate
180 days
GE Dehu Road, Pune
please refer tender documents
7 documents required · 7 mandatory
₹500
GE, Dehu Road, Pune
₹50,000
Yes
4 Mar 2021
23 Nov 2020
24 Dec 2020
23 Nov 2020
17 Dec 2020
3 Dec 2020
60 days
Amount
Cleaning sewage line 100mm bore SGSW / RCC pipe upto 2.5 M below GL ground level with mechanical cleaning device and water jets etc and bringing out all foreign materials / mud sludge etc. from the lines removing the same through the manholes and cleaned with water complete all as specified and as directed by Engineer -in- Charge.
All as per item No. 01 above for 150 mm dia line and upto 1.5 m in depth below GL complete all as specified and as directed by Engineer -in- Charge.
All as per item No. 01 above for 200 mm dia line and upto 1.5 m in depth below GL complete all as specified and as directed by Engineer -in- Charge.
Cleaning of septic tank of any depth by removing of sludge, silt, or mud etc. First by dewatering with mechanical systems of septic tanks and filter beds with mechanical pumps and sucking out or mechanically removing the accumulated sludge , silt and mud etc, from bedsand removing burring and chlorinated in the ground outside MD land including cleaning of surfaces completely with water etc complete all as specified and as directed by Engineer -in- Charge. Note:- Solid material only be measured and element of dewatering is deemed to be included in rates.
All as per item no. 04 above but only cleaning of Man Holes upto 1.00 mtr depth complete all as specified and as directed by Engineer -in- Charge.
All as per item no. 04 above but only cleaning of Man Holes exc 1.00 mtr depth but n exc 2.00 mtr depth complete all as specified and as directed by Engineer -in- Charge.
Excavation in trenches n exc 1.5 mtr deep & n exc. 1.5 mtr wide and getting out in soft/loose soil for taking out drain pipe, cable etc or for foundation complete all as specified and as directed by Engineer-in-Charge.
Returning filling in including levelling , watering and well ramming in layers n exc 25 cm thick in soil complete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to a distance n exc. 50 M & depositing where directed at a level n exc. 1.5 M above starting point complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced )as in manholes cover slab complete all as specified and as directed by Engineer-in-Charge.
Demolition of brick work or stone/boulder masonry including all quoins, arches, pillars etc , precast concrete articles and precast concrete block walling built in cement mortar complete all as specified and as directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and as directed by Engineer-in-Charge
Dismantlimg/Taking down AC waste/Vent pipes fixed to walls with all fittings/accessories 100 mm dia pipes all as specified and as directed by Engineer-in-Charge
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in concrete for 150 mm dia pipes all as specified and directed by Engineer-in-Charge.
All as per Item No 14 only but of 200 mm dia pipes complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC 1:4:8 type D-2 (Using 40mm granded stone aggregate ) as in foundations and mass concrete all as specified and as directed by Engineer-in-Charge.
M&L for precast Cement concrete (1:2:4) Type B-1 (20mm graded stone agg) as in cover slabs for man holes, set and jointed in CM (1:4) Complete. Note:- Reinforcement shall be measured and paid separately.
M&L for mild steel TMT bars 6 to 8 mm and over dia cut to length, bent to shape required incl cranking, bending, hooking ends & binding with & incl mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surface incl mixing of water proofing compound finished even & smooth with using extra cement complete all as specified and directed by Engineer-in-Charge. (Note: WPC shall be measured & paid seperately)
Supply only imtegral water proofing compound.
S&F in repair PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls, or laid in trenches bore of pipe 110 mm dia complete all as specified and directed by Engineer-in-Charge.
S&F in repair 110 mm dia PVC (SWR) bends, any radius with access door complete all as specified and directed by Engineer-in-Charge.
S&F in repair 110 mm dia PVC (SWR) branch piece single (Single 'Y') equal or unequal complete all as specified and directed by Engineer-in-Charge.
S&F in repair 110 mm dia PVC (SWR) branch piece double, (double 'Y') equal or unequal complete all as specified and directed by Engineer-in-Charge.
S&F in repair 110 mm dia PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC (SWR) pipes 75 mm dia ,single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC (SWR) bends any radius, 75mm dia pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair 75mm dia pipe PVC (SWR) branch piece, single (single Y) equal or unequal,for complete all as specified and directed by Engineer-in-Charge.
S&F in repair 75mm dia pipe PVC (SWR) branch piece, double (double Y), equal or unequal,for complete all as specified and directed by Engineer-in-Charge.
S&F in repair 75 mm dia PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete pipes class NP-2 , laid in trenches & jointed complete with collars, dia of pipe 150 mm complete all as specified and directed by Engineer-in-Charge.
All as item No. 31 above but for 200 mm dia of pipe complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in bed to drain pipes, incl forming cradels after they are laid and tested for 150 mm bore RCC pipe complete all as specified and directed by Engineer-in-Charge.
All as item No. 33 above but for 200 mm dia RCC pipe complete all as specified and directed by Engineer-in-Charge..
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc all as specified
M&L for Chequered cement concrete tiles of 20 cm x 20cm x 25 mm thick with grey cement and pigment,set and jointed in neat cement slurry in floors including 15 mm thick screed bed or bedding layers in cement mortar 1:6 for laying tiles complete all as specified and as directed by Engineer-in-Charge .
M&L non skid coloured ceramic tiles 7 to 8 mm thick area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm , in floors, etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match. Including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
M&L Glazed ceramic tiles in vertical surface 450x300x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles incl backing coat 10mm thick in CM 1:4 all as specified and as directed by Engineer-in-Charge.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern) of size 580x440 mm white with 'P' or 'S' trap including plastic water closet seat, black/white closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device connection to drains (or outgoing pipes) and to the flushing pipes, complete all as specified and directed.
S&F in repairs vitreous china squating pan Orissa pattern of size 580x440 mm white with 'P' trap front or back inlet and foot rest any pattern including provision of lime concrete complete all as specified and directed.
M&L for cleaning of all blockage of any type of trap, water closet, soil waste/vent pipe, gully traps upto first manhole by removing all chocked materials of any suitable means and equipment including foreign materials and removing the same to a distance exceeding 100 mtr and n exc 200 mtr and making good the disturbed surfaces as per existing where required and as directed by Engineer-in-Charge
H S TAKHI
Preeti Enterprises
S Y Itkar Construction and Company
M/S VR Construction Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .