Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.6 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹54.2 L+₹5.8 L (12.0%)Rejected-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 UDYAM DL 01 0031798 | CENTRAL DELHI | DELHI | 110002 | L2 | Rejected-AOC ok | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Recommended for opening of second cover |
Tender Value
₹54 L
EMD Value
₹1.1 L
Closing Date
25 Dec 2021, 6:00 pmClosed
CWE Dehradun
HQ CWE Dehradun
REPAIR/MAINTENANCE OF TRANSFORMER AND ALLIED WORKS AT GARHI CANTT AND ANARWALA UNDER GE DEHRADUN.
2021_MES_489485_1
9643/DDN/E8
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
GE Dehradun
₹1.1 L
Yes
3 Feb 2022
20 Nov 2021
27 Dec 2021
20 Nov 2021
25 Dec 2021
13 Dec 2021
Amount
Supply, Laying, connecting up and testing control cable 6 core 10 Sqmm electric power cable with stranded copper complete all as specified and as directed.
Supply, Laying, connecting up and testing cable XLPE insulated galvanised steel strip or wire armoured electric power cable with stranded aluminium conductor 11000 V grade (Earthed) of size 185 sqmm 3 core complete all as specified and as directed.
All as per item No 2 here-in-above but of size 120 sqmm 3 core complete all as specified and as directed.
All as per item No 2 here-in-above but of size 95 sqmm 3 core complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in soft/loose soil complete all as specified and as directed.
Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness all complete all as specified and directed. Note :- Only punned down sand thickness 18CM shall be measured and paid.
Supply and lay un-reinforced precast concrete cable cover , class ,HV , Type I as per IS -5820 with flat size 300 x 180 x 40 mm laid dry in trenches over underground cables complete all as specified and as directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft/loose soil complete all as specified and as directed.
Removing of excavated soil to a distance n exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for under ground Horizontal Pneumatic horizontal drilling of holes under road, rail, pavement, hard standing by trenchless technology using ultra sound technique to measure the project depth. Minimum HDD depth of 1.5m and maximum depth of 4m and pulling the 110mm pipe complete all as specified and directed. Note: 1. Measurement of HDD will be for pipe length end to end. 2. Contractor to submit profile graph of HDD along with claim bill.
S&F cable jointing kit for 11 KV grade for indoor termination, heat shrink type joint with complete jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 Sqmm complete all as specified and directed.
M & L 100 mm bore mild steel tubes light grade galvanised, with all fittings laid in trenches or walls or for passing earth strip, etc , complete including taking down old unserviceable tubes complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage up to 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x1m complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Taking out transformer from its position from location under GE Dehradun for repair/ servicing/ rewinding of following capacity with OLTC, 11/.415KV ,disconnecting/ opening HV, LV electrical, earthing connections complete all as specified and directed.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Transportation of transformer to authorized workshop (UPCL authorized company as approved by Accepting officer) by making necessary arrangements of T&P (crane, recovery, vehicle etc.) for the following capacities transformers.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
M&L for opening of transformer top cover by extraction, removing of serviceable/ unserviceable nuts bolts and washers etc for the following capacities transformers.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Draining out of transformer oil.
M&L Lifting primary (HT) and secondary coil (LT) , dismantling of transformer complete part by part carefully & display all the parts without damaging any portion for inspection complete all as specified and directed for the following capacities transformers.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
M&L for transformer winding including taking out and testing for serviceability and rewinding the same with fresh copper wire or strip including insulation paper bobins etc and keeping the same into the hot air oven till the moisture will remove and insulating resistance improves to the satisfaction level, re fixing the same in original position complete all as specified and directed. Note:- Old unserviceable copper scrap will be retained by contractor under sch of credit.
M&L for replacement of press board & insulation complete all as specified and directed for the following capacities transformers.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
M&L for replacement of gasket & washer complete all as specified and directed for the following capacities transformers.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
M&L for Replacement of Silica Gel Breather (Main Tank + OLTC Tank) complete all as specified and directed for the following capacities transformers.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
M&L for Complete overhauling of On Load Tap Changer (OLTC) and including replacement of wiring conductors, connectors including wiring of control cable connections and connection complete all as specified and directed.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
M&L for replacement of HV & LV Termination complete all as specified and directed for the following capacities transformers.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
M&L for replacement of sundry items like tapes, sleeves, bakelite, nut & bolts wherever required complete all as specified and directed for the following capacities transformers..
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Heating, drying & meggar improvement complete all as specified and directed for the following capacities transformers.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Re-assembling the transformer complete with all existing serviceable parts and new parts as per requirement i.e. repair labour charges complete all as specified and directed for the following capacities transformers.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Filling of New ISI mark transformer oil after dehydration and filtration in transformer at works shop complete all as specified and directed. Old unserviceable transformer oil scrap will be retained by contractor under sch of credit.
Return back from workshop with placement of transformer to its position at location under GE Dehradun after repair/ servicing/ rewinding of capacity 11/0.433 KV Reconnecting HV, LV electrical connections, earthing connections along with following other works like checking & testing of HT line / HT Cable, HT Switchgear etc complete all as specified and directed for the following capacities transformers. Note:- (a) All routine tests will be carried out at manufacturer works (b) Transformer will have warranty period of 6 months from the date of re-fixing at site. (c) UPCL authorized dealers/representative of approved firm shall be available at the time of commissioning of transformer. (d) Any other work required to carryout above job in inclusive.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
M&L for PCC 1:5:10 type E-2 using 40mm graded stone aggregate for foundation of poles stays etc as in mass concrete complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate for foundation of poles/stays etc as in mass concrete complete all as specified and directed.
M&L for PCC1:2:4 type B-1 using 20mm graded stone aggregate as in coping for poles/ stays etc incl necessary form work complete all as specified and directed.
S&F cable jointing kit for 11 KV grade for indoor termination, heat shrink type joint with complete jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 to 225 Sqmm complete all as specified and directed.
S&F cable jointing kit for 11 KV grade for indoor termination, heat shrink type joint with complete jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm complete all as specified and directed.
M&L for earthing complete with GI earth plate electrode of size 600x 600 and 6mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 m below ground level with top edge of the plate not less than 1.5 m below ground level connected with GI wire 4 mm dia by means of nuts, bolts, check nuts and washers made of GI or steel earthing lead to be protected by GI pipe 20 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch all as shown in electrical plate No 3 of SSR Part-I 2009 including providing funnel with 20mm bore GI pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded stone aggregate), 50mm thick precast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia), with 40x40x6mm MS angle iron frame including necessary earth work and testing on completion, complete all as specified and as directed.
M&L Copper earthing with 3 mtr depth . 80 mm dia Electrode ( copper Earthing 50mm) Supply Of Advance Maintenance Free Chemical Gel Earthing Electrode (Medium) Copper 80mm Dia 3Mtr Long, inner pipe 48 mm dia Filled With Highly Conductive metallic Compound Mixture CCM, With The Permanent Sealing Of The Both End , Outer Dia Pipe 50 mm With The Strip Terminal 50x6, Terminal Hole, Include with one 50 kg ,bag of bfc Compound (including installation) and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/ Lt panel etc. and testing on completion complete all as specified and directed.
M&L for earth continuity conductor or main earthing strip fixed to wall on batten or porcelain insulators or recess or chases or buried in ground or drawn in and including GI pipe 40 mm bore or fixed with poles or any other indicated situation for loop earthing etc as required using copper strip of size 32 X 6 mm complete all as specified and directed. NOTE :- (i) Cost of GI Pipe shall be inclusive in quoted rates of this item.
S&F PT 33 KV outdoor type single Phase oil cooled PT of ratio 33/rt3/110/rt3/110rt3 class 0.50-3, burden 50 VA, insulation level 70/170 KV voltage factor 1.2 Cont and 1.9 for 30 second confirming to IS 3156 including taking down old unserviceable PT complete all as specified and directed including taking down existing old unserviceable PT complete all as specified and directed.
S&F CT 33 KV outdoor type single Phase oil cooled CT of Single phase, dead tank, outdoor, oil, Pedestal type, As per IS 2705 Pt. I, Rated short time with stand current, 25kA(RMS), 3 phases , One minute Power Freq. 70kV & 28kV withstand voltage (RMS) , System fault level -25kA for 3sec, CT ratio as existing including taking down old unserviceable CT & PT complete all as specified and.
S&F in replacement of unserviceable station class type Lightning arrestor suitable for 33 KV discharge current 65 KA fixed on existing steel structure including connection with earth strip conforming IS 3070 (Part -3) 1983 Class 'A' complete all as specified and directed including taking down existing old unserviceable complete all as specified and directed.
S&F in repair of insulator pin type porcelain vitreous, white brown or green 150mm height and 150mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 33000 volt grade complete all as directed including disconnection and taking down existing lightning arrestor complete all as specified and directed.
M&L for shifting transformers of capacity 63 to 200KVA capacity. The contractor shall provide the lifting equipment’s like Crane/Hydra/Excavator Machinery and removing the transformer from Plinth/4 Pole structure/2 Pole structure duly disconnecting all incoming/outgoing connections and earthing complete all as specified and directed.
M&L for shifting transformers of capacity 250 to 500KVA capacity. The contractor shall provide the lifting equipment’s like Crane/Hydra/Excavator Machinery and removing the transformer from Plinth/4 Pole structure/2 Pole structure duly disconnecting all incoming/outgoing connections and earthing complete all as specified and directed.
M&L for fixing of HT 33 KV out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators and with earth switch up to 200/400 Amps complete all as specified and as directed
M&L for spraying of agricultural based chemical to control the growth of unwanted herb, shrubs etc including cutting, removing the vegetation growth & surface dressing all around the installation yard/ transformer /LT panel Board area external only and remove the herb, shrubs, creepers etc on the LT/HT Poles the to keep installation always clean and tidy condition. Note:- All the installation yards/area shall be kept clean throughout contract period by repeatedly by removing the grass/shrubs as many times required depending on the growth of grass measurement will be measured & paid only once throughout contract period only once.
M&L for removing the herb, shrubs, creepers etc on the LT/HT Poles the to keep poles/structures always clean and tidy condition. Note:- All the Poles shall be kept clean throughout contract period by repeatedly by removing the grass / shrubs as many times required depending on the growth of grass measurement will be measured & paid only once throughout contract period only once.
M&L for taking out transformer from its position from location under GE Dehradun for repair/ servicing/ rewinding of capacity 3150 KVA with OLTC , 33/11 KV Make ITC ,disconnecting/ opening HV, LV electrical connections, earthing connections along with following other works as under for 3150 KVA Transformers complete all as specified and directed.
Transportation of transformer to authorized workshop (OEM Work shop ie Gurgaon, Haryana) or on workshop as directed and approved by the Accepting officer and back to site by making necessary arrangements of T&P, crane, recovery, vehicle etc. complete all as specified and directed.
M&L for opening of transformer top cover by extraction, removing of serviceable/ unserviceable nuts bolts and washers etc complete all as specified and directed.
Draining out of transformer oil complete all as specified and directed.
M&L for Lifting primary coil (HT) and secondary coil (LT), dismantling of transformer complete part by part carefully and display all the parts without damaging any portion for inspection complete all as specified and directed.
M&L for replacement of Press Board & Insulation complete all as specified and directed.
M&L for replacement of Gasket & washer complete all as specified and directed.
M&L for replacement of Silica Gel Breather (Main Tank + OLTC Tank) complete all as specified and directed.
M&L for complete overhauling of On Load Tap Changer including OLTC panel with replacement of AVR Relay including wiring with suitable size of copper wire complete all as specified and directed.
M&L for replacement of HV & LV Termination complete all as specified and directed.
M&L for replacement of sundry items like Tapes, Sleeves, Bakelite, Nut & Bolts wherever required complete all as specified and directed.
M&L for heating, drying & meggar mmprovement complete all as specified and directed.
M&L for reassembling the transformer complete with all existing serviceable parts and new parts as per requirement i.e. repair labour charges etc complete all as specified and directed.
M&L for placement of transformer to its position at location under GE Dehradun after repair/ servicing/ rewinding of capacity 3150 KVA , 33/11 KV Reconnecting HV, LV electrical connections, earthing connections along with following other works like checking & testing of HT line / HT Cable, HT Switchgear etc complete all as specified and directed. Note:- (i) All routine tests will be carried out at manufacturer works (ii) Repaired Transformer will have warranty period of six months from the date of re-fixing at site. (iii) Representative of authorised firm shall be available at the time of commissioning of transformer.(iv) Quoted rate shall deemed to be inclusive for any other work required to carry out this job.
M/s Kamal Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .