Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹3.0 L+₹1,494.73 (0.51%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹3.1 L
EMD Value
₹7,626
Closing Date
13 Jul 2026, 6:00 pmClosed
Assistant Executive Engineer
Assistant ExecutiveEngineer, PWD Electrical subdivision,Tvpm
GENERAL-Annual Maintenance Contract of ductable air conditioning unit of cardiology ICU in cardiology Theatre,Dialysis,Nephro High Dependency Unit in Golden Jubilee Block of SAT hospital attached to Medical College Tvpm-Electrical AC Work
2026_PWD_859018_1
ESDT/ET-52/2026-27
Open Tender
Electrical Works
Percentage
365 days
PWD Electrical sub division Thiruvananthaouram
please refer tender documents
6 documents required · 6 mandatory
₹675
₹7,626
28 Jul 2026
4 Jul 2026
17 Jul 2026
4 Jul 2026
13 Jul 2026
4 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Air conditioning | |||||
| 1.001 | OD328353/2025-2026:All inclusive Comprehensive maintenance contract of the following air conditioner units including replacement of defective accessories, refrigerant controls, pressure testing of the system, vacuuming, oil charges,replacing defective single phase preventer,three pole contractor etc. as required and excluding the replacement of defective compressor, electrical Mains switches and Civil works.Any error/failure calls will attend immediately on report.11 TR Air Cooled Duct able Split AC units service of the plant 12 times per year
(1.Safety controls such as pressure cutouts will be tested for proper functioning and in case of any malfunctioning they will be repaired/replaced.
2.Air filters will be inspected and cleaned.
3.Cooling coil will be inspected and cleaned.
4.The blower motor will be checked and any defects noticed will be attended.
5.The driver set of the motor will be checked and any defects noticed will be attended.
6.The condenser fan motor will be attended to.
7.The condenser coil will be inspected and cleaned.
8.Repairs to refrigerant piping due to system problems will be attended) | - | each | 37,503.8 | - |
| 1.002 | OD328354/2025-2026:Charges for filling sufficient quantity of Freon 32/410A gas for existing air conditioner unit including leak testing rectifying the defects leak arresting including brazing and make the compressor in good working condition for the following. 1TR/1.5TR/2TR/3TR | - | kg | 1,043.63 | - |
| 1.003 | OD72548/2026-2027:Supply and fixing ofSelf-adhesive vinyl sticker for lettering and figures of sizes and colour selected by the Engineer in charge for the identification mark to fan, AC, SB, DB, panel board , fire etc as required | - | sqcm | 0.07 | - |
| 1.004 | OD72553/2026-2027:Cleaning and painting of base frame in installed position with one or more coats of painting with synthetic enamel paint of approved brand and manufacture. | - | sqm | 324.38 | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1452349.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1452349.xls
BOQ • 0.31 MB
mom.pdf
Tender Documents • 11.87 MB
sbd.pdf
Tender Documents • 1.63 MB
acsc.pdf
Tender Documents • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .