| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC D NO 10 36 3 2 FLAT NO N 1 DASARATHA ENCLAVE RAM NAGAR VISAKHAPATNAM 530 002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.5 L+₹2.2 L (6.34%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹43.2 L+₹8.0 L (22.7%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹43.3 L+₹8.1 L (23.1%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
3 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) (DM) VISAKHAPATNAM
GE (I) (DM) VISAKHAPATNAM Naval Dockyard 530014
OVERHAULING OF PBS, JBS, CP AT JETTY GALLERY, REPLACEMENT OF UNSV PB/JB/CP AND ALLIED WORKS AT OLD DOCKYARD AREA AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2022_MES_499951_1
SSGE/8681/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (I) (DM) VISAKHAPATNAM
As per tender documents
8 documents required · 8 mandatory
₹500
GE (I) (DM) VISAKHAPATNAM
₹98,000
Yes
16 Feb 2022
6 Jan 2022
10 Feb 2022
6 Jan 2022
3 Feb 2022
20 Jan 2022
60 days
Amount
M&L for de-carbonizing/cleaning of LT 415/380 V 3 phase, 4 wire Junction boxes inside Jetty Gallery used for distribution of power to different pillar boxes by removing cover, by dismantling bunch of cable termination of 3ph+N busbar (cable terminations are not less than 16 nos in each phase of 150 sqmm to 500 sqmm) taking out aluminium/copper complete busbar off sizes, checking for any defects due to any flush, loose contact and cleaning of complete bus with CTC, cleaning of all bus insulators and re-fixing bus etc after applying Backtol (red) solution to the insulator and and refixing all cable connections, replacement of damaged cable lugs and replacement of damaged nuts, bolts, washers and tightening of all nuts, bolts including one coat of painting to inside chamber of cope point with synthetic enamel paint complete all as specified and as directed. Note: (a) required aluminium or copper busbars, coloured heat shrink sleeve for busbar, cable kits, will be measured as supply only, (b) required busbar insulators, aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate.
M&L for de-carbonizing/cleaning of LT 415/380 V 3 phase Air Circuit Breaker at Pillar boxes inside/above Jetty Gallery by removing outer door, inner door, by draw-out movable unit from base, keeping aside carefully, removing all cable connection from rear side bus, interconnection bus between main bus and ACB, checking for any defects due to any flush/loose contact, cleaning of all fixed and moving contact point, terminal connection points with CTC and re-fixing moving unit of ACB, cables, bus the same after applying Backtol (red) solution to the bus bar insulator and replacement of defective aluminium cable lugs and tightening the nuts, bolts, spring washers & thimbles complete all as specified and as directed. Note: (a) required male/female ACB contacts, trip coils, closing coils, electronic protection unit will be measured as supply only. (b) required aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate (c) all cleaning agents are included in the quoted rate. (d) Disconnection and reconnection of cable will measured separately
M&L for de-carbonizing/cleaning of complete LT 415/380 V 3 phase Pillar boxes inside/above Jetty Gallery by removing cover, by dismantling bunch of cable termination of 3ph+N busbar from inside gallery (cable terminations are not less than 4 nos in each phase of 150 sqmm to 500 sqmm) taking out aluminium/copper complete busbar off sizes, checking for any defects due to any flush, loose contact and cleaning of complete bus with CTC, replacing damaged coloured heat shrink sleeve, cleaning of all bus insulators and re-fixing bus etc after applying Backtol (red) solution to the insulator and refixing all cable connections, replacement of damaged cable lugs and tightening the nuts, bolts, washers including one coat of painting to inside chamber of cope point with synthetic enamel paint complete all as specified and as directed. Note: (a) required aluminium or copper busbars, coloured heat shrink sleeve for busbar, cable kits, will be measured as supply only, (b) required busbar insulators, aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate.
M&L for de-carbonizing/cleaning of complete LT 415/380 V 3 phase Cope points fixed at edge of Jetty with half portion above GL and half portion in gallery by removing cover, by dismantling bunch of cable termination of 3ph+N busbar from inside gallery (cable terminations are not less than 4 nos in each phase of 150 sqmm to 500 sqmm) taking out aluminium/copper complete busbar off sizes, checking for any defects due to any flush, loose contact and cleaning of complete bus with CTC, replacing damaged coloured heat shrink sleeve, cleaning of all bus insulators and re-fixing bus etc after applying Backtol (red) solution to the insulator and refixing all cable connections, replacement of damaged cable lugs and tightening the nuts, bolts, washers including one coat of painting to inside chamber of cope point with synthetic enamel paint complete all as specified and as directed. Note: (a) required aluminium or copper busbars, coloured heat shrink sleeve for busbar, cable kits, will be measured as supply only, (b) required busbar insulators, aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate.
Dismantling taking out complete cable end of sizes 150 sqmm to 500 sqmm, 3.5 core from Cope point/ACB/MCCB, cutting cable ends for replacement of burnt/defective aluminium cable lugs or heat shrink cable end Joints of suitable size or for outdoor heat shrink sleeves single core of suitable size for extended length of XLPE cable and fixing to ACB/MCCB terminals/busbars with nuts, bolts, washers, aluminium cable lugs complete all as specified and as directed. Note- (a) heat shrink cable end joints, heat shrink sleeves will be measured measured separately as supply only, (b) required aluminium cable lugs and nuts-bolts-washers and busbar insulator shall be inclusive of quoted rate
Supply only fixed contract of ACB 1200A to 3200A complete all as specified and as directed.
Supply only Moving contract of ACB 1200A to 3200A complete all as specified and as directed.
Supply Only Electronic protection unit of ACB 1200A to 3200A complete all as specified and as directed.
Supply Only shunt trip coil of ACB 1200A to 3200A complete all as specified and as directed.
Supply Only closing coil of ACB 1200A to 3200A complete all as specified and as directed.
S&F CT (Current transformer), 1100 volts grade, CT ratio 800/5 to as per existing shape and size including connections and rectification of internal wiring defects after dismantling taking out unserviceable one complete all as specified and as directed.
Supply & fix digital Ammeter 0-2000 A including connections and rectification of internal wiring defects after dismantling taking out unserviceable one complete all as specified and as directed.
Supply & fix digital Voltmeter 0-500 V including connections and rectification of internal wiring defects after dismantling taking out unserviceable one complete all as specified and as directed.
Supply only Heat shrink cable end terminal for 3.5 core 1100 V, 150 to 185 sqmm. Make 3M, cat No MHI/Ox1.1KV(HESL-4/4C) or equivalent of Denson/M Seal/MS Seal/RPG complete all as specified and as directed.
Supply only Heat shrink cable end terminal for 3.5 core 1100 V, 240 to 300 sqmm Make 3M, cat No MHI/Ox1.1KV(HESL-5/4C) or equivalent of Denson/M Seal/MS Seal/RPG complete all as specified and as directed.
Supply only Heat shrink cable end terminal for 3.5 core 1100 V, 400 to 500 sqmm Make 3M, cat No MHI/Ox1.1KV(HESL-6/4C) or equivalent of Denson/M Seal/MS Seal/RPG complete all as specified and as directed.
Supply only Heat Shrink sleeve outer protection insulating tube (Coated) single core, for application range 13-38mm suitable for outdoor use to any weather condition, Make- RPG, cat No-WCSM-48/12 or equivalent of 3M/Denson/M Seal complete all as specified and as directed.
Supply only coloured Heat Shrink sleeve busbar insulation tube single core, for application range upto 150 mm , Make- RPG, cat No-WCSM-33/8 or equivalent of 3M/Denson/M Seal complete all as specified and as directed.
Supply and fix heat shrink straight through joint, LT 1100 volts grade, 3.5 core, 150 to 185 sqmm after dismantling taking out cable from cable tray at gallery or at trench, after complete preparation complete all as specified and as directed. Make 3M, cat No MHS/Ox1.1KV(HSLA-4/4C) or equivalent of Denson/M Seal/MS Seal/RPG
All as per item No 19.00 above but of heat shrink straight through joint, LT 1100 volts grade, 3.5 core, 240 to 300 sqmm. Make 3M, cat No MHS/Ox1.1KV(HSLA-5/4C) or equivalent of Denson/M Seal/MS Seal/RPG
All as per item No 19.00 above but of heat shrink straight through joint, LT 1100 volts grade, 3.5 core, 400 to 500 sqmm. Make 3M, cat No MHS/Ox1.1KV(HSLA-6/4C) or equivalent of Denson/M Seal/MS Seal/RPG
Supply only Busbar anodised aluminium off sizes including required drilling holes for fixing with other bus / cable connections complete all as specified and as directed.
Supply only Busbar anodised copper off sizes including drilling holes for fixing with other bus / cable connections complete all as specified and as directed.
Supply and fix LT ACB 3 pole 3200 A, 50 KA breaking capacity, 415 V, 50 Hz, manual drawn out type and manually charged with micro processor ET2L trip unit (Without display) release protection system against over current, earth fault and short circuit with 2 NO + 2 NC auxiliary switch, safety shutter, cradle guard, operating handles conforming to IEC 60947-2 & 3 complete all as specified and as directed. Make:- Cat.No. MVS32N3MW2L of schneider equivalent make in L&T/ABB/GE/lEGRAND
All as per item No 24.00 above but of capacity 2500Amps,3pole Cat.No. MVS25N3MW2L of schneider equivalent make in L&T/ABB/GE/Legrand complete all as specified and as directed.
All as per item No 24.00 above but of capacity 2000Amps,3pole Cat.No. MVS20N3MW2L of schneider equivalent make in L&T/ABB/GE/lEGRAND
All as per item No 24.00 above but of capacity 1600Amps,3pole Cat.No. SPS16F3PMW2B of schneider equivalent make in L&T/ABB/GE/lEGRAND
All as per item No 24.00 above but of capacity 1250Amps,3pole Cat.No. SPS12F3PMW2B of schneider equivalent make in L&T/ABB/GE/lEGRAND
Supply and fix MCCB, 3 pole 400 amps, 36 KA breaking capacity, Ics = 100% Icu, with thermal magnetic release, Make Schneider/ABB/Legrand complete all as specified and as directed.
M&L for painting of outer surface of multiple section of complete VCB panel 11 Kv size up to 2 m x 1.8 m X 0.8 m in one substation using one coat of synthetic enamel paint after preparation of surface, providing protection cover to all metering equipment, panel meters, switchgears, cleaning of all meters and switch gears complete all as specified and as directed.
SAI ENGINEERING WORKS
B.Veerabhadra Rao
R AND A ASSOCIATES ENGINEERS CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .