Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹75,875Accepted-AOC 676301 | MALAPPURAM | KERALA | 676301 | ₹75,875 Quoted ₹75,874.52 | 1 | Accepted-AOC lowest |
| 2 | 2₹79,979.72Rejected-AOC 28 298 EVM BUILDING BYPASS ROAD THIRURANGADI MALAPPURAM 676306 | MALAPPURAM | KERALA | 676306 | ₹79,979.72 | 2 | Rejected-AOC 2 nd lowest |
Tender Value
₹84,296
EMD Value
₹2,107
Closing Date
25 Feb 2026, 4:00 pmClosed
ASSISTANCE EXECUTIVE ENGINEER
PWD ELECTRICAL SUBDIVISION MALAPPURAM
GENERAL-Providing new Security light and existing High mast Lights for Security lights in the 29 K Battalion NCC Calicut University Malappuram District Electrification General Electrical Work
2026_PWD_838165_1
ELSDM -118/2025-26
Open Tender
Electrical Works
180 days
THENGIPALAM
Please refer Tender documents.
11 documents required · 11 mandatory
₹555
₹2,107
13 Mar 2026
19 Feb 2026
28 Feb 2026
19 Feb 2026
25 Feb 2026
19 Feb 2026
Electrification
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD108606/2025-2026:Dismantling the feeder cable from the mast inspection box lowering the lantern carriage to the bottom and cleaning all terminal box, attending to minor repairs of existing flood light if necessary, giving connection to all lamps, and lifting the lantern carriage to the mast top and test running, etc as required
OD108604/2025-2026:Supplying and fixing 240/415 volts, 30A AC1/12A AC3 Power contractor 3Pole with 240V operating voltage in the existing MCB DB complete with connections, testing and commissioning etc. as required.
OD108600/2025-2026:Supplying and fixing 24Hr Timer switch with NO/NC operating voltage 230V in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD108602/2025-2026:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipment's including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 4Sqmm single run
OD108597/2025-2026:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipment's including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 1.5Sqmm single run
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
2.10.5:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1411848.xls
BOQ • 0.32 MB
015728970271000List.pdf
Other Document • 0.19 MB
viewsbd.pdf
Tender Documents • 1.63 MB
Download all tender documents and submit your bid