Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC KALIBARI BAZAR TUPKHANA PART I PO ARUNACHAL P S SILCHAR DISTT CACHAR ASSAM 788 025 | SILCHAR | CACHAR | ASSAM | 788025 | ₹18.9 L Quoted ₹19.3 L | L1 | Accepted-AOC Being L1 bid |
| 2 | L2₹19.6 L+₹34,380 (1.78%)Rejected-AOC | ₹19.6 L+₹34,380 (1.78%) | L2 | Rejected-AOC Being higher than L1 bid |
| 3 | L3₹19.8 L+₹53,773 (2.79%)Rejected-AOC | ₹19.8 L+₹53,773 (2.79%) | L3 | Rejected-AOC Being higher than L1 bid |
| 4 | L4₹20.0 L+₹71,495.50 (3.71%)Rejected-AOC | ₹20.0 L+₹71,495.50 (3.71%) | L4 | Rejected-AOC Being higher than L1 bid |
| 5 | L5₹20.2 L+₹94,086 (4.88%)Rejected-AOC | ₹20.2 L+₹94,086 (4.88%) | L5 | Rejected-AOC Being higher than L1 bid |
Tender Value
Refer Docs
EMD Value
₹36,600
Closing Date
4 Jan 2021, 6:00 pmClosed
GARRISON ENGINEER SILCHAR
GE SILCHAR, PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
SPECIAL REPAIRS FOR REPLACEMENT OF OH LT LINE TO UG CABLE FROM BLDG NO P-49 TO SECURITY POST NO 03 AND TO AERIAL BUNCH CABLE FROM BLDG NO T-503 TO RR HILL AND PROVN OF WATER GEYSERS AT MASIMPUR MIL STN UNDER GE SILCHAR
2020_MES_391885_2
8589/E8
Open Tender
Civil Works
Item Rate
180 days
MASIMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹36,600
Yes
25 Feb 2021
18 Dec 2020
5 Jan 2021
18 Dec 2020
4 Jan 2021
21 Dec 2020
Amount
Dismantling of existing ACSR or AAC conductors (of any size), jumper from overhead line removing unserviceable material from site of work complete all as specified and directed.
Dismantling of corroded/rusted/defective cross-arms of MS channel or angle of any sections complete all as specified and directed.
Dismantling of unserviceable insulators of any size/type complete all as specified and directed.
Dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed
Supply, fixing, commioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors,1100 volts, grade cross sectional area 16 Sqmm, 4 core laid in trenches/fixed to wall/under road/pipe etc with and including copper cable glands & copper thimbles complete all as specified and directed.
Supply, fixing, commioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors,1100 volts, grade cross sectional area 25 Sqmm, 4 core laid in trenches/fixed to wall/under road/pipe etc with and including copper cable glands & copper thimbles complete all as specified and directed.
Supply, fixing, commioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 50 Sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with and including copper cable glands & copper thimbles complete all as specified and directed.
Supply, fixing, commioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 95 Sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with and including copper cable glands & copper thimbles complete all as specified and directed.
Supply, fixing, commioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 120 Sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with and including copper cable glands & copper thimbles complete all as specified and directed.
Supply, laying, testing and commissioning of Aerial bunched cable XLPE insulated with aluminium conductor of size 50 sqmm 3 single core & one messenger cable of size 35 sqmm 01 core fixed on 09 Mtr pole with clamps of suitable size as directed by Engineer-in-Charge complete all as specified and directed.
Material and labour for LT jointing kit straight through epoxy based suitable for 95 sqmm 3.5 core cable complete all as specified and directed.
Excavation in trenches not exceeding 1.50 meter wide and not exceeding 1.5 meter in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in trenches including Spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing of surplus soil to a distance not exceeding 50 meter and deposited where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed.
Material and labour for laying of bricks locally available sub-class 'B' brick (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the directon of cable complete all as specified and directed.
Supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. Note:- Thickness of sand cushion after punning down will be measured and paid separately.
Supply and laying GI tube light grade 50 mm bore with fitting laid in trenches of for road crossing for protection of LT underground cables complete all as specified and directed.
M&L for Boring hole under-neath road/hardstanding/pavement with trenchless technology using mechanical drilling/horizontal boring machine for crossing of cable without cutting the surface and providing 80mm bore HDPE pipe suitable for 0.4mpa working pressure and making good the disturbed area etc complete all as specified and directed. Note : 80mm bore HDPE pipe is deemed included in unit rate quoted by the contactor.
Material and labour for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip 25 x 4 mm by means of galvanized iron or steel bolts, nuts, check nuts and washers, and connected to equipments as directed, including funnel with GI medium grade watering pipe 20 mm bore, 40 mm bore light grade protection pipe , wire mesh, charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C1, 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance not exceeding 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES Schedule 2009, Part-I complete all as specified and directed.
M&L for point wiring with single core PVC insulated cable of size 2.5 Sqmm nominal area with multi-stranded copper conductor FRLSH , 1100V grade drawn drawn through and including PVC non metallic concealed conduit of suitable dia with all fitting and accessories , PVC terminal box of suitable size with cover for mounting switch/sockets etc of suitable size including 2.5 sqmm PVC insulated unshealhed single core multi-stranded FRLSH copper conductor earth continuity wire connected to common earth dolly with proper colour coding for one 5/6 pin, 15 Amps socket point control by one switch on independent board, incl cutting chasis & marking good to disturbed surface to match with existing surface complete all as specified and directed.
S & F switch piano 15 Amps single pole, Flush type one way 230 V with cover plate complete all as specified and directed.
S & F socket outlet 15 Amps 5/6 pin , Flush type one way 230 V with cover plate ccomplete all as specified and directed.
M & L for circuit /submain wiring alongwith earth wire 2 x 4.0Sqmm FRLSH PVC insulated unsheathed cable multi-stranded FRLSH copper conductor drawn through and including PVC non metallic concealed conduit of suitable dia with all fitting and accessories including 1 x 4.0 Sqmm PVC insulated unsheathed single core multi-stranded FRLSH copper conductor earth wire incl cutting chasis & marking good to disturbed surface to match with existing surface complete all as specified and directed Note: Two run of single core cable and one run of earth wire will be mearsured as one length.
S & F sheet metal enclosure for MCBs distridution board, 240V, 2 way single pole without bus bar complete all as specified and directed.
S & F MCB SPN 40 Amps, 240 V , 10KA breaking capacity complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor 6 sqmm standard conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed.
Supply and fix Bib taps 15 mm dia fancy type Chromium plated with crutch or butterfly handle screwed down, screwed for iron pipes and for brass ferrule and fixed complete all as specified and directed
Supply and fix Stop valves, cast copper alloy,but fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Supply and fix Geyser (water storage heater) of capacity 25 ltr, 5 star rating with 2KW heating element including fixing on the wall with 12 mm dia x 100 mm long GI fastner, nut and bolt by grouting at required position including testing on completion including making all necessary water supply and electric supply connections to water Geyser from existing point and also inclusive of making good to distrubed surface with existing surface complete all as specified and directed. Make :- Havells Cat Part No PURO TURBO 25 L or equivalent in Bajaj/ Crompton Greaves/ Venus
Supply and fix hot water outlet connection made of brass chromium plated with union rubber washer suitable for 15mm bore GI pipe for water complete all as specified and directed.
Supply and fix tubes 15mm bore medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors, Cutting cheses for concealed water tubing and making good with concrete mortar 1:3 and surface shall be match with existing surface by using tiles, putty, pop etc and applying finishing coat of existing treatment complete all as specified and as directed.
M/S PIJUSH BHATTACHARJEE
M/S P K ROY AND SONS
M/S TAPAN KUMAR RAY
m/s builders and suppliers
NAGALAND AGENCIES CO
MS AFTAB LASKAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .