Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹1.0 L
Closing Date
15 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Shalimar
Supply Installation Testing and Commissioning of Hybrid Solar 50 Kwp Plant with Battery backup complete in all respects for Veterinary Clinic at FVsc and AH Shuhama SKUAST Kashmir
2021_SKUST_118660_1
E-NIT 22 of 2020
Open Tender
Miscellaneous Services
Item Rate
20 days
Shalimar
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
Asstt.comptroller Estates office
₹1.0 L
Yes
16 Mar 2021
1 Mar 2021
16 Mar 2021
1 Mar 2021
15 Mar 2021
1 Mar 2021
120 days
Amount
Solar PV Modules SITC of Solar Panel 300 to 380 watt MONO Perc with 72 Cells & should have a 25 years of warranty or 325WP, 72 Cell/ Make:- Adani /Goldi/ Vikram solar/ Saatvik/ Waree/Panasonic/ Mono-Csi-JAKSON/SSI/MNRE approved of MNRE approved make. (Complete qty in all respects for 50Kwp plant )
Hybrid Inverter SITC Hybrid inverter Should be Approved by MNRE, & Tested by Govt Approved Solar testing Lab & test Certificates should be Enclosed with Inverter. Hybrid inverter 50kw/3P/ 440V/240V . having Import Export Facility & should have GPRS Solar data Monitoring Facilities Hybrid Inverter-50 KW/240V or equivalent 50Kwp Hybrid SPP with (02V/300AH) Battery bank -having up (Three hrs) Battery Backup Solar PCU 50 KW (240V) MNRE Approved make Fuji-electric/Schenider/ Hybrid /SUNGROW-/ MNRE or equivalent 50Kwp Hybrid SPP (7.2VAH/Wp) Battery back-up (three hrs) Solar PCU 50 KW of make Fuji-electric/Schenider/ Hybrid /SUNGROW-/ Statcon/MNRE Approved
Batteries. 02V 300AH lead acid tubular or equivalent volts 150Ahx12 Volt for hybrid inverter of 50 KWp 3 Hr backup Make Exide Solar / Amaron Solar including all Transportation, Installation and commissioning charges
Structure for Roof top 50 kWP) AL Structure with fasterners 6 MM - SS Farstener with two Washers with 25 x 3 GI Strip for Structure Earthing GI Earthing Strip (AC+DC+LA) with complete earthing works pit , PVC cover, Chemical 2 Mtr Long electrode etc
Earth Pit for (AC+DC) 17.2 MM Dia, 3 M Long, CU Plated, Chemical Earthing
LA-ESE 50 M Radius, 5 M Height-ESE type with all accessories inc. Earth Pit for LA 17.2 MM Dia, 3 M long x 4 mm copper strip CU Plated, Chemical Earthing
4 SQmm DC Solar cable for Module/SJB/AJB/ Inverter 1Cx 4 sq.mm 1.1 kV Solar PV cable (R+B) 4 SQmm DC Solar cable for Module/SJB/AJB/ Inverter/Polycab /Havells /Finolex
MC4 Connector Pair MC4 Connector Pair (Male, Female,Pins) - Suitable for 4 Sq.mm for connecting string
Green cables 1Cx6 Sq.mm Cu.Flex Green cables
Conduit 40 MM- HDPE with L & T Joints and Coupler and end cap
Cable Tray-GI-Perforated 100x50x1.6mm GI-Perforated-with cover & clamps
AC cable4 - Inverter to LT panel 3.5C-70 Sqmm, Cu AR,1.1kV Cable Havells /Finolex/Polycbab
Cable 3.5C-35 Sqmm, Cu AR,1.1kV Cable able Havells /Finolex/Polycab
Cable 1C-70 Sqmm, Cu AR,1.1kV Cable Cable MMDC Cu(in Mtrs) Polycab /Finolex /Havells
Cable Cable1C 95sq MM for battery bank Cu (in Mtrs) Polycab /Finolex /Havells
Junction boxes ARY Junction box
Junction boxes Main Junction Box
DB AC Distribution box.
Rack Battery rack for mounting batteries Complete job for 120 Nos
ACDB AC Distribution Board suitable for outdoor (IP-65), Structure/Wall mount type construction with following items: A) 2 numbers 63 Amp, 4P,10kA for 1 Sec MCB with required terminal block for incoming 3.5C x 25 Sq.mm Ar.AL Cable, & 1 numbers 125 Amp, 4P,10kA for 1 Sec MCCB with required terminal block for outgoing cable 3.5C x 70 sqmm Al.Ar Cable required terminal block (Make :- Schneider/Reputed) B) Three number control MCB of, SP, 6Amp , 10KA for 1 Sec. (Make :- Schneider/Reputed ) C) Three no. Current Transformer Cast Risen type, Cl-0.5, 5VA, 125/5 Amp with Test certificate. (Make :- AE/Kappa/G&M/Reputed) D) One no Flush Mounted KWH meter (Make-Secure - Elite-445/ Consreve EM6400) with Accuracy class of 0.5, with RS 485 Port, 415VAC, 3-Ph, 4 Wire with test certificate for the same having glass window at the enclosure for energy meter monitoring. E) One indicating light, LED type, with R, Y, B, 230Volt AC (Vaishno / C&S / Schneider/Reputed ) F) One no. 16A, 1Ph, socket with plug and 10A DP MCB, 10kA for 1 sec with 4sqmm. cable (Reputed) G) Enclosure with wall mounting arrangement for outdoor Application IP65 along with suitable heat dissipation arrangement shall be provided. Holes with glands for cable entry shall be provided. H) Control Cable and Power Cable shall be FRLS Type, 1.1KV Grade, ISI marked (Make :- KEI / Polycab / HAvells / CCI/Reputed) I)One No. AC SPD, Type 2, 40kA for 1 sec. (Make - Phoenix Contact VAL-MS 320/3+1/FM-2859181) J) One Set TPN Busbar of 125A rating K) Enclosure Shall be Powder coated with RAL-7032 paint shade with minimum thickness upto 65 micron. CPRI / ISO (Make – /Schnieder Electric/L&T) (Double Compression Gland are required of sutaible size for incoming cable & outgoing cable)
Sensor-1 Ambiemt Temprature sensor 1 no
Sensor-2 Module Temprature sensor 1 no
Sensor-3 IR Sensor Referenc Cell 1 no
Data Logger Multi In 1 Out Data on Cloud server through DLMS MODBUS 1 no
Modem 3G/ 4G Srevice enable 1 no
CAT-4/6 Cable CAT-4/6 Cable 50 Meter
0.75 KVA UPS Backup for 15 Mins 1 no
Modem 3G/ 4G Srevice enable 1 no
CAT-4/6 Cable CAT-4/6 Cable 200 Meter
Data Logger Box Poly carbonate Box IP-65, Outdoor application 700 x 700 MM, with Mounting Din rail,Gland, (Front Side Transprint) 1 no
0.75 KVA UPS Backup for 15 Mins 1 no
Fire extinguisher 2.5 kg, CO2 type
Energy Meter Bi Directional Energy meter with CT /PT . Complete in all respects including panel and stand etc
Servo Supply , installation of Servo Voltage Stabilizer with specifications as : • Capacity : 50 KVA, 3 Phase • Input voltage : 90-270 V per Ph. (155-467 V) • Accuracy : 415 +1% • Cooling : Naturally and Oil cooled • Complete with Oil topping • Speed of Correction : >8 V per second • Type: un Balanced Type • Winding: Full Copper wound • Efficiency: 95% • Auto/Manual operation facilities. • Fully solid state circuit using triacs/thyristor. • Three number Voltmeter (0-500V) provided for reading input/output voltages • Overload/under load protection with oil topping , high cut , low cut Make: Vintek/Alba/Integ/Cosco/Convergence/Deltron/ Vision/Elient/Chinar
Changeover Supply /installation of Auto changeover 100 AMP 4 pole with mountage and panel etc Havelll’s/SSK/Equivalent/L&T
Termination Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 kV grade as required
Control SITC of MCCB 160 Amp TPN Legrand /hager make having breaking capacity 50kA including termination job
Spreader S/I of speaders link copper 160 Amp
Note:-The rates quoted are inclusive of all carriages (Mechanical/Manual) of materials from source to site work and all extra charges complete in all respects.
Shah Industries
Grun Umwelt Energy Pvt
KASHMIR RENEEWABLE ENERGY PRIVATE LIMITED
M/S SUNNERGY SYSTEMS
KIRSO POWER PRIVATE LIMITED
M/S ORION VALLEY SOLAR PVT LTD
VLAST E SERVICE
siab surgiments
stage.html
html • 0.03 MB
finance_227922.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .