Loading…
Loading…
Tender ID
Tender Value
₹16.8 Cr
EMD Value
₹16.8 L
Closing Date
19 Feb 2026, 6:05 pmClosed
Executive Engineer (R & B) Division, Bharuch
Construction of High level Major bridge on Kim River at Valia-Mangrol Road Km. 0/00 to 12/400 (W.S. 11/400 to 11/500) Ta. Valia Dist. Bharuch
274244
51 of 2025-26
Open
Civil Works - Bridges
Works
Bharuch
19 documents required · 16 mandatory · 3 optional
₹18,000
Yes
Executive Engineer, Bharuch (R&B) Division, Bharuch
₹16.8 L
Yes
7 Feb 2026
7 Feb 2026
7 Feb 2026
19 Feb 2026
7 Feb 2026
No. figures Amount
1 Providing flood gauge marks on sub structure as per design 28.00 Rmt 155.26
including painting as directed etc. complete.
2 Providing masonary steps with cement pointing on approaches as 34.00 Steps 219.53
3 Providing and laying filter media 600mm as directed at the back of 234.00 Smt 1180.34
abutments, returns and wing walls as per detailed specifications etc.
4 Providing and filling sand behind abutment & between returns in 932.00 Cum 445.41
layers as directed.
5 Excavation for foundation in hard murrum and boulders and very 1813.00 Cum 582.22
stiff or sticky clays and other similar strata including sorting and
strutting and dewatering as necessary and disposing of excavated
stuff as directed.
6 Providing and filling in foundation with ordinary cement concrete M- 187.00 Cum 3475.16
15 mix and providing necessary vertical pin headers including
formwork, vibrating, ramming and curing complete.
7 Diversion of water course, providing cofferdam and bund or island 6.00 Each 50500.00
as may be necessary for foundation and maintaining the same for
the period as may be necessary (B) Diversion by cofferdam / island.
8 Empty boring through all sorts of strata for providing 1.50m. 2066.00 Rmt. 3382.34
diameter R.C.C. bored piles to required depth including providing
necessary casing pipes with all plants and equipments as required
complete as per specifications.
9 Providing and casting in situ controlled concrete M-40 for R.C.C. 3651.00 Cum 4781.30
bored piles of 1.50 M dia. including ramming, vibrating and finishing
excluding reinforcement complete.
10 Providing and placing in position I.S.I. mark deformed bar 1268.76 M.T. 73150.49
reinforcement (T.M.T.) of grade Fe-550D for following items
including cutting, bending, hooking, tying etc. complete as per
detailed drawings and specifications for various structural
components.
11 Conducting load testing (Prefer Static load test) of a single pile up to 2.00 No. 35767.11
following capacity in accordance with IS:2911 (Part-IV) including
installation of loading plate form and preparation of pile head or
construction of test cap and dismantling of test cap after test etc.
with all labours, material, tools & plate, equipments, machinery etc.
complete as per drawing and specification, as directed by Engineer.
(Initial load test & Routine load test)
It. Rate in Total
Description of Item Qty. Unit
No. figures Amount
12 Performing Integrity Test (low strain) on vertical pile. The item shall 56.00 No. 1212.00
include chipping of weak concrete at the top of pile, leveling,
bending of reinforcing bars, preparation of pile head including
testing with pile driving analyser or approved equivalent. To be
carried out at least 15 days after concreting of piles. A specialist
approved Agency shall be employed by the Contractor for the test.
The test shall be carried out as per relevant ASTM code.The item is
including complete testing with approved apparatus, analysis of
results and conclusions including submission of test reports in three
hard copies with soft copy in CD.
13 Providing and casting in-situ controlled cement concrete M-40 for 1480.00 Cum 4982.38
R.C.C. piles cap including necessary form work vibrating, curing
and finishing complete.
14 Providing and casting in-situ controlled cement concrete M-35 for 166.00 Cum 4612.45
R.C.C. raft (Return wall footing pad) and cut-off including necessary
shuttering, laying, vibrating, ramming and curing complete.
15 Chipping and dressing of the RCC piles upto cut-off level including 99.00 Cum 886.06
cleaning of reinforcement and removal of dismantled materials etc.
for providing pile caps as directed by Engineer and as per
specification.
16 Providing Steel Liner 8 mm thick for pile including fabricating and 117.00 M.T. 47323.74
setting out as per detailed drawing.
17 Providing and laying weep holes in abutment and returns by using 234.00 Each 82.57
A.C. pipes of 100 mm. including laying in proper grade and jointing
the completed as per directed specification.
18 Providing and casting in situ controlled cement concrete M-35 for 392.98 Cum 5184.78
R.C.C. work in abutment, piers & Return wall as per drawing
including centering, shuttering, scaffolding where necessary laying,
vibrating, curing and finishing complete. (A) Height from 0.0 mt. to
19 Providing and casting in situ controlled cement concrete M-35 for 81.250 Cum 5487.67
R.C.C. work in abutment, piers & Return wall as per drawing
including centering, shuttering, scaffolding where necessary laying,
vibrating, curing and finishing complete. (B) Height from 5.0 mt. to
20 Providing and casting in situ controlled cement concrete M-35 mix 336.00 Cum 5262.95
for R.C.C. work in pier cap, abutment cap and dirt wall including
controlled cement concrete M-40 bed blocks or pedestals of
required size below bearings as per detailed drawings including
centering, shuttering, scaffolding wherever necessary laying,
vibrating, curing and finishing complete.
21 Providing and laying in position fully moulded restrained 645120.00 Cu.c 1.06
elastromeric bearing as per detailed drawings. m.
22 Providing and casting in situ controlled cement concrete M-35 for 718.00 Cum 5733.28
R.C.C. work in superstructure (16.0 m RCC T beam & Deck slab)
including centering, ramming vibrating, curing and finishing
complete. (B) T Beam Deck slab type of superstructure (II) T Beam
Girder, Slab and Cross girder.
23 Providing and casting in situ controlled cement concrete M-40 for 128.00 Cum 5373.61
average 100mm thick wearing coat laid as directed including
tamping, vibrating, finishing, curing and filling in joints with bitumen
etc. complete.
It. Rate in Total
Description of Item Qty. Unit
No. figures Amount
24 Provision of an Reinforced cement concrete crash barrier at the 242.00 Rmt. 1533.18
edges of the road, approaches to bridge structures and medians,
constructed with M-40 grade concrete with TMT reinforcement
conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at
expansion joints filled with pre-moulded asphalt filler board, keyed
to the structure on which it is built and installed as per design given
in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III
dated 24 June 1994 as per dimensions in the approved drawing and
at locations directed by the Engineer, all as specified.
25 Providing P.V.C. 100mm dia. water spouts including necessary iron 48.00 No. 159.37
grating as per detailed drawing including placing etc. complete.
26 Providing and fixing marble slab including engraving letters, 2.00 No. 1012.65
numbers and painting etc. complete. (A) size 75 cm x 60 cm x 4 cm.
27 Providing and casting in situ controlled cement concrete M-30 for 33.00 Cum 5073.17
approach slab including form work, curing and finishing etc.
28 Providing and fixing in position Strip Seal type expansion joint 60.00 Rmt. 1733.16
catering to maximum horizontal movement upto 70 mm, complete
as per approved drawings and standard specification to be installed
by the manufacturer / supplier or their authorised representative
ensuring compliance to the manufacturer's instructions for
installation.
29 Finishing wall with weather proof exterior emulsion paint on wall 362.00 Sq.m. 114.54
surface (two coats) to give an required shape even shade after
thoroughly brushing the surface to remove all dirt, dust and remains
of loose powdered materials etc. complete.
30 Dismentaling the existing structure including removing and stacking 2184.50 Cum 886.06
the dismentelled materials as and where directed. (A) R.C.C. work.
31 Providing and applying one coat Epoxy Phenolic primer of DFT 50 2014.00 Sq.m. 183.82
micron and two coats of Epoxy Phenolic coating of DFT
microns each or any other equivalent epoxy coating system to all
concrete surfaces exposed to atmosphere in substructure including
cost of material, labour, transportation, scaffolding and preparing
the surfaces by cleaning, washing, brushing, sand / grit blasting etc.
complete and as directed by Engineer and as per specification.
(Paint shall be got approved from Engineer and tested from
approved laboratory).
32 Providing fusion bonded Epoxy coating not less than 175 micron 497.00 M.T. 10162.62
thickness and up to 300 micron to reinforcement bars as per
IS13620-1993/ASTM-775 M including testing of coating at plant and
all taxes (A) 10mm to 16mm dia bar.
33 Providing fusion bonded Epoxy coating not less than 175 micron 745.00 M.T. 7296.24
thickness and up to 300 micron to reinforcement bars as per
IS13620-1993/ASTM-775 M including testing of coating at plant and
all taxes (B) 20mm to 32 mm dia bar
34 Providing and fixing the continuity arrangement in deck slab as per 36.00 Rmt. 8319.37
the detailed with fixture, components, filler etc. complete by
Engineer in charge.
It. Rate in Total
Description of Item Qty. Unit
No. figures Amount
35 Earth work for embankment including breaking clods, dressing with 766.50 Cum 169.44
all lead and lift including watering, rolling and consolidation of sub
grade in layer and consolidation of sub grade in layers at O.M.C. to
required dry density including filling the depressions which occur
during the process using vibratory roller 8 t to 10 t (C) from borrow
area within all lead and lift.
36 Clearing and grubbing of road land including uprooting trunk 0.40 Hect. 28393.04
vegetation, grass, bushes, shrubs, saplings and trees of girth up to
300 mm removal of stumps of trees cut earlier and disposal of
unserviceable materials and stacking of serviceable materials to be
used or auctioned upto a lead of 1000 meters including removal
and disposal of top organic soil not exceeding 150mm thickness (C)
by mechanical means in area of light jungle.
37 Construction of 200 mm thick compacted GRANULAR SUB BASE 833.00 Cum 1149.38
(Grading-I, Crushed B.T. materials of 53 mm to 9.5 mm @ 50%,
mm to 2.36 mm @ 20%, Below 2.36 mm @ 30%) by providing
close graded material, mixing in a mechanical mix plant at OMC,
carriage of a mix material to work site, spreading uniform layers with
motor grader on prepared surface and compacting with vibratory
power roller to achieve desire density, complete clause as per
38 Construction of 200 mm thick compacted granular sub base 816.00 Cum 959.50
(Grading-IV, Crushed B T materials of 26.5 mm to 9.5 mm @ 64%,
9.5 mm to 4.75 mm @ 11%, Below 4.75 mm @ 25%) by providing
close graded material, mixing in a mechanical mix plant at OMC,
carriage of a mix material to work site, spreading uniform layers with
motor grader on prepared surface and compacting with vibratory
power roller to achieve desire density, complete clause as per
39 Providing and laying 250 mm thick Wet Mix Macadam (W.M.M.) 996.00 Cum 1041.31
(Two layers each of 125 mm) using machine crushed black trap
aggregate of 40 to 50 mm size in the material as per MORT&H
specification including premixing the material with water at OMC in
mechanical mix plant, carriage of mixed material by tippers to site,
laying in uniform layers with paver in sub base / base course on well
prepared surface and compacting with vibratory roller to achieve the
desired density.
40 Providing and applying priming coat using Slow Setting (SS-1) 3895.00 Sq.m. 62.62
emulsion asphalt at the rate of 7.5 kg/10 Sq.M. on water bound
macadam / W.M.M surface etc. complete including cleaning the
surface with cost of all labour materials.
41 Providing and laying 75 mm thick Bituminous Macadam (grading-2) 642.00 M.T. 2662.36
with B.T. aggregate as per MORT&H specification & bituminous
emulsion RS-1 for tack coat @ 2.5 Kg / 10 Sq.m. on B.T surface
with mechanical sprayer & bitumen grade VG-30 for mixing @
Kg. / M.T. i.e. 3.4% of total weight of mix including heating & mixing
the aggregate & asphalt in drum mix plant and spreading the same
by paver finisher & consolidation with vibratory roller including
providing all materials equipments, tools & plants, fire wood, oil,
kerosene, labour charges etc. complete using contractor's own
machinery drum mix plant & paver finisher etc. complete.
It. Rate in Total
Description of Item Qty. Unit
No. figures Amount
42 Providing and laying 25 mm thick Semi Dense Bituminous Carpet 224.00 M.T. 3315.76
using specified graded crushed black trap stone aggregates as per
MORTH gradation using VG-30 (60/70) bulk bitumen for mixing at
the rate of 5.0 % (50.0 Kg./M.T.) by hot mix process in drum mix
plant and hot laid process using paver finisher to the required
camber and grade including rolling with vibratory roller to achieve
desired density including cost of clearing using fire wood, oil,
Kerosene, labour charges and hire charges of machineries etc.
43 Providing and laying compacted 100 mm thick of specified quarry 47.00 Cum 725.18
spall in side shoulder including carraige of material and spreading
on prepared base including compacting as per MOST Specification
etc. complete.
44 Road marking with hot applied thermoplastic paints with 195.00 Sq.m. 367.73
reflectorising glass beads on bitumen surface providing and laying a
hot applied thermoplastic compound 2.5 mm thick including
reflectorising glass beads @ 250gms per sqm area, thickness of
2.5mm is excluding of surface applied glass beads as per IRC:35-
2015. The finished surface to be level, uniform and free from
streaks and holes. zebra patta / bump patta lane / center line / edge
line/cut patta. The white colour marking should provide luminance
coefficient on cement road shall be min 130 mcd/m2/lux and
Asphalt road shall be min 100 mcd/m2/lux during the service life
during the day time. The marking should meet the performance
criteria for night time reflectivity, wet reflectivity and skid resistance
as mentioned in the section-15 of IRC 35-2015.
45 Cat Eye/ Road Stud/ RPM : Supplying Raised Pavement Markers 142.00 No. 217.41
made of polycarbonate and ABS moulded body and reflective
panels with Micro prismatic lens (No Glass bead lens) capable of
providing total internal reflection of the light entering the lens face
and shall support a load of 13635 kgs. tested in accordance to
ASTM D4280 Type H and complying to Specifications of Category A
of MORTH Circular No RW/NH/33023/10-97-DO III Dt. 11.06.1997.
The Height, width and length shall not exceed 20 mm, 130 mm and
130 mm and with minimum reflective area 13 sqcm on each side
and the slope to the base shall be 35+/-5 degree. The body of the
marker should having finger grip for easy and accurate placement
and application with epoxy / bituminous adhesive as recommended
by the manufacturer of the marker. The colour of the marker should
be as per the IRC 35-2015 and as directed by Engineer-in-charge.
It. Rate in Total
Description of Item Qty. Unit
No. figures Amount
46 Direction (Junction) Sign :- Providing and fixing sign boards made 2.00 No. 26572.09
out of 2mm aluminium sheet / 4mm ACP (Aluminum composite
panel) size 244 x 122 cms. rectangular as per design of IRC-67-
2012. Pre treated with phospheting process & acid etching; coated
with one coat of epoxy primer and two coats of best quality epoxy
paint ;reflectorised with Micro Prismatic grade retro reflective
sheeting of Type-11 as per ASTM D-4956 and latest M.O.S.T.
Specifications; 4.0mtr long (2 Nos.) stand post of 75 x 75 x 6mm /
65NB Circular MS Pipe as required and frame fabricated from
suitable size iron angle of 50 x 50 x 5mm; painted with best quality
epoxy coatings in black and white bends. The details of symbol for
each board shall be as per the instruction of engineer in charge.
The fixing at site shall be in 1:2:4 CC block of size 45 x 45 x
cms. for each leg including excavation, curing etc. complete under
the supervision of engineer in charge. A warranty for 10 years for
the Retro reflective sheeting from original manufacturer & a certified
copy of 3 year outdoor exposure test report from third party test lab for
the product offered shall be submitted by contractor.
(A) Class-C Type-11 Retro Reflective sheeting
47 Cautionary Warning Sign :- Providing and fixing sign boards made 2.00 No. 5077.27
out of 2mm aluminium sheet / 4mm ACP (Aluminum composite
panel) size 90 x 90 x 90 cms. equilateral triangle as per design of
IRC-67-2012. Pre treated with phospheting process & acid etching,
coated with one coat of epoxy primer and two coats of best quality
epoxy paint reflectorised with Micro Prismatic grade retro reflective
sheeting of Type-11 as per ASTM D-4956 and latest M.O.S.T.
Specifications; 3.6mtr long stand post of 75 x 75 x 6mm / 65NB
Circular MS Pipe as required and frame fabricated from suitable
size iron angle of 35 x 35 x 3mm; painted with best quality epoxy
coatings in black and white bends. The details of symbol for each
board shall be as per the instruction of engineer in charge. The
fixing at site shall be in 1:2:4 CC block of size 45 x 45 x 60 cms. for
each leg including excavation, curing etc. complete under the
supervision of engineer in charge. A warranty for 10 years for the
retro reflective sheeting from original manufacturer & a certified
copy of 3 year outdoor exposure test report from third party test lab for
the product offered shall be submitted by contractor.
(A) Class-C Type-11 Retro Reflective sheeting.
It. Rate in Total
Description of Item Qty. Unit
No. figures Amount
48 Facility Informatory Sign :- Providing and fixing sign boards made 1.00 No. 5906.48
out of 2mm aluminium sheet / 4mm ACP (Aluminum composite
panel) size 80 x 60 cms rectangular as per design of IRC-67-2012.
Pre treated with phospheting process & acid etching; coated with
one coat of epoxy primer and two coats of best quality epoxy paint,
reflectorised with Micro Prismatic Grade retro reflective sheeting of
Type-11 as per ASTM D- 4956 and latest M.O.S.T. Specifications;
3.6mtr long stand post of 75 x 75 x 6mm / 65NB Circular MS Pipe
as required and frame fabricated from suitable size iron angle of
x 35 x 3mm; painted with best quality epoxy coatings in black and
white bends. The details of symbol for each board shall be as per
the instruction of engineer in charge. The fixing at site shall be in
1:2:4 CC block of size 45 x 45 x 60 cms. for each leg including
excavation, curing etc.complete under the supervision of engineer
in charge. A warranty for 10 years for the retro reflective sheeting
from original manufacturer & a certified copy of 3 year outdoor
exposure test report from third party test lab for
the product offered shall be submitted by contractor.
(A) Class-C Type-11 Retro Reflective sheeting.
49 Hazard Marker Sign :- Providing and fixing sign boards made out of 2.00 No. 3666.30
1.5mm aluminium sheet / 3mm ACP (Aluminum composite panel)
size 90 x 30 cms. rectangular as per design of IRC-67-2012. Pre
treated with phospheting process & acid etching; coated with one
coat of epoxy primer and two coats of best quality epoxy paint
reflectorised with Micro Prismatic Grade retro reflective sheeting of
Type-11 as per ASTM D- 4956 and latest M.O.S.T. specifications;
1.8mtr long stand post of 75 x 75 x 6mm / 65NB Circular MS Pipe
as required and frame fabricated from suitable size iron angle of
x 35 x 3mm; painted with best quality epoxy coatings in black and
white bends. The details of symbol for each board shall be as per
the instruction of engineer in charge. The fixing at site shall be in
1:2:4 CC block of size 45 x 45 x 60 Cms. for each leg including
excavation, curing etc.complete under the supervision of engineer
in charge. A warranty for 10 years for the retro reflective sheeting
from original manufacturer & a certified copy of 3 year outdoor
exposure test report from third party test lab for the
product offered shall be submitted by contractor.
(A) Class-C Type-11 Retro Reflective sheeting.
50 Providing and fixing Hectometer as per I.R.C. type design including 4.00 No. 356.50
painting, lettering etc. complete (ii) Fixing in C.C. 1:5:10.
51 Providing and fixing Guard stone as per I.R.C. type design including 40.00 No. 349.11
white washing etc. complete (ii) Fixing in C.C. 1:5:10
52 Excavation for foundation upto 1.50 mt. depth including sorting out 1471.00 Cum 241.80
and stacking of useful material and disposing off the excavated stuff
within all lead and lift for Dense or hard soil.
53 Providing and laying rubble Gabion (each stone weight not less than 1582.00 Cum 1041.05
40 Kg) including hand packing and filled in the interstices with
quarry spaull.
54 Providing and Supplying of Mechanically Woven, Double Twisted, 1582.00 Cum 1338.25
Hexagonal wire mesh Zinc+ PVC Coated Gabion boxes, Mesh
opening Type : 10 x 12, Wire dia: 2.7/3.7 mm, Selvedge wire dia:
It. Rate in Total
Description of Item Qty. Unit
No. figures Amount
55 Providing, supplying and installation of 200 GSM Non Woven 1016.10 Sq.m. 45.45
Geotextile needle punched, polypropylene material having minimum
roll size of 5 mt. x 100 mt. including all labours etc. complete.
56 Providing and laying rubble pitching of 22.50 cm. thick with filling the 216.00 Sq.m. 623.09
sand in the interstices & C.C. 1:3:6 panelling at 3.0 mt. C/C and
cms. x 30 cms. panel wall as per the detailed drawing with
necessary excavation and providing water chutes of C.C. 1:3:6 at
24.00 mt. C/C providing pointing on rubble pitching in C.M. 1:3 etc.
57 Providing and erecting a 'W' type metal beam crash barrier 40.00 Rmt. 3496.62
comprising of 3 mm thick corrugated sheet metal beam rail 70 cm
above road/ground level fixed on ISMC series channel vertical post
150 x 75 x 5 mm spaced 2 mt centre to centre, 1.8 mt height, 1.1 mt
below ground /road level, all steel parts and fitments to be
galvanised by hot dip process, all fittings to confirm to I.S 1367 and
I.S 1364, metal beam rail to be fixed on the vertical post with a
spacer of channel section 150 x 75 x 5 mm, 330 mm long complete
as per clause
58 Providing Designing Supplying and Installation of extruded Bi-Axial 1152.00 Sq.m. 111.10
Polypropylene 30 kn GeoGrid including all labours & etc. complete.
Total Rs.
i.e. Rs. Sixteen Crore, Seventy Eight Lacs, Twenty Six Thousand, Two hundred Five and Eighty One paisa only
I/We am/are willing to carry out the work @ ______________ % above/below percent (Should be written
in figures and words) of the estimated rate mentioned above. Amount of my /our tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct………% below Add………% Above
Net Rs. ___________________________ Total Rs. ________________________
In words ____________________ In words ____________________
1. The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge
for which no extra payment shall be made.
2. The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3. GST and Income tax TDS will be deducted at a source while making payments of bills.
4. In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017
Cement Consumption/16/C, Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as per
actual mix design the cost of difference of cement consumption have been deducted from the rate of original item at the
rate of input rate mentioned in all the tender.
5. The Contractor will have to submit the all required mix design at his own cost before execution as directed and to
be approved from the Engineer in charge.
6. Credit for dismantalled materials of amount of Rs. 4,36,900.00 must be recovered from 1st R.A. bill of Contractor's.
Above all items of "Schedule-B" with Item Description, Unit, Rate & Amount have verified by me and found
Deputy Executive Engineer Sr. Divisional Account Officer Executive Engineer
Ankleshwar (R & B) Sub Division, Bharuch (R & B) Division, Bharuch (R & B) Division,
Ankleshwar Bharuch Bharuch
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
E Tender Notice - Major bridge Kim River.pdf
SBD Book - Major bridge Kim River-Valia-Mangrol.pdf
BOQ - Major bridge Kim River - Valia-Mangrol.pdf
Specification Index.pdf
General Techical Specifications.pdf
Spe. Conditions - Bridge.pdf
GRs.pdf
Drawings.pdf
GAD_KIM RIVER - GAD.pdf
PQ - Major bridge Kim River - Valia-Mangrol.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .