Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 CrAccepted-AOC | ₹6.2 Cr | L1 | Accepted-AOC Contract awarded to M/s Shitapa Traders by the committee due to L1 |
| 2 | L2₹6.5 Cr+₹31.9 L (5.15%)Rejected-Finance 0 BAROO KARGIL KARGIL KARGIL LADAKH 194105 | KARGIL | LADAKH | 194105 | ₹6.5 Cr+₹31.9 L (5.15%) | L2 | Rejected-Finance Due to L2 Bid Rank |
| 3 | L3₹8.2 Cr+₹2.0 Cr (33.0%)Rejected-Finance | ₹8.2 Cr+₹2.0 Cr (33.0%) | L3 | Rejected-Finance Due to L3 Bid Rank |
| 4 | Rejected-Technical | - | - | Rejected-Technical Due to not uploading the requisite Documents, DD, EMD, Solvency Certificate, Working Capital Certificate, Police Verification and Affidavits as per NIT |
| Sl No | Description | Qty | Unit | M/S ZAILDAR ENTERPRISES L2 | shitapa traders L1 | Intrernational Engineers L3 |
|---|---|---|---|---|---|---|
| 1.00 | Building work
SCHEDULE 'A' PART-I
Completion of incomplete / balance work in Construction of block of 12 Havs and 88 Ors (Double storey), complete all as specified and shown on drawings
(First Block) (Refer page No 22 and 25 ) | 1 | EACH BLOCK | 24,50,000 ₹24,50,000 | 21,00,000 ₹21,00,000 Lowest | 87,91,626 ₹87,91,626 |
| 1.01 | Completion of incomplete / balance work in Construction of block of 12 Havs and 88 Ors (Double storey), complete all as specified and shown on drawings (Second Block)
(Refer page No 22 and 26 ) | 1 | EACH BLOCK | 24,50,000 ₹24,50,000 | 21,00,000 ₹21,00,000 Lowest | 87,91,626 ₹87,91,626 |
| 1.02 | Completion of incomplete / balance work in Construction of block of common and study room (single storey), complete all as specified and shown on drawings.
(Refer page No 22 and 27 ) | 1 | EACH BLOCK | 2,80,000 ₹2,80,000 Lowest | 3,00,000 ₹3,00,000 | 10,00,000 ₹10,00,000 |
| 1.03 | Completion of incomplete / balance work in Construction of block of cook house and dining hall (single storey), complete all as specified and shown on drawings.
(Refer page No 22 and 28 ) | 1 | EACH BLOCK | 7,25,000 ₹7,25,000 Lowest | 8,00,000 ₹8,00,000 | 21,00,000 ₹21,00,000 |
| 1.04 | Completion of incomplete / balance work in Construction of block of plant room/ DG set/ pump house with duty room, store and toilet (150 Sqm) (single storey), complete all as specified and shown on drawings.
(Refer page No 23 and 29 ) | 1 | EACH BLOCK | 6,50,000 ₹6,50,000 | 5,00,000 ₹5,00,000 Lowest | 9,00,000 ₹9,00,000 |
| 1.05 | Completion of incomplete / balance work in Construction of block of sub station building (84 Sqm) (Single storey), complete all as specified and shown on drawings.
(Refer page No 23 and 30) | 1 | EACH BLOCK | 2,80,000 ₹2,80,000 Lowest | 3,00,000 ₹3,00,000 | 8,00,000 ₹8,00,000 |
| 1.06 | Completion of incomplete / balance work in Construction of RCC under ground sump 30,000 ltrs capacity, complete all as specified and shown on drawings.
(Refer page No 23 and 31 ) | 1 | EACH | 1,10,000 ₹1,10,000 Lowest | 1,50,000 ₹1,50,000 | 8,00,000 ₹8,00,000 |
| 1.07 | Construction of block of covered interconnecting passage 2.40 mtr wide complete, all as specified and shown on drawings.
(Refer page No 23 and 31) | 28 | RUNNING METRE | 73,500 ₹20,58,000 | 65,000 ₹18,20,000 Lowest | 85,000 ₹23,80,000 |
| 1.08 | Completion of incomplete / balance work in Construction of septic tank 100 users (Stone masonry), complete all as specified and shown on drawings.
(Refer page No 24 and 31 ) | 2 | EACH | 60,000 ₹1,20,000 | 40,000 ₹80,000 Lowest | 70,000 ₹1,40,000 |
| 1.09 | Completion of incomplete / balance work in Construction of septic tank 10 users (Stone masonry), complete all as specified and shown on drawings.
(Refer page No 29 and 31 ) | 2 | EACH | 25,000 ₹50,000 | 14,000 ₹28,000 Lowest | 60,000 ₹1,20,000 |
Tender Value
₹3.9 Cr
EMD Value
₹4.7 L
Closing Date
19 Aug 2025, 6:00 pmClosed
CWE KHUMBATHANG
HQ CWE KHUMBATHANG PIN 900270 C/O 56 APO
COMPLETION OF INCOMPLETE WORK FOR PROVN OF OTM ACCN FOR BIMBAT AT DRASS
2024_MES_638513_7
80051/73/E8
Open Tender
Civil Works
Lump-sum
545 days
DRASS
Class A Cat a (i) and b (ii)
8 documents required · 8 mandatory
₹2,000
GE KARGIL
₹4.7 L
Yes
19 Sept 2025
1 Aug 2025
21 Aug 2025
1 Aug 2025
19 Aug 2025
6 Aug 2025
1 Aug 2025 - 5 Aug 2025
Amount
Building work SCHEDULE 'A' PART-I Completion of incomplete / balance work in Construction of block of 12 Havs and 88 Ors (Double storey), complete all as specified and shown on drawings (First Block) (Refer page No 22 and 25 )
Completion of incomplete / balance work in Construction of block of 12 Havs and 88 Ors (Double storey), complete all as specified and shown on drawings (Second Block) (Refer page No 22 and 26 )
Completion of incomplete / balance work in Construction of block of common and study room (single storey), complete all as specified and shown on drawings. (Refer page No 22 and 27 )
Completion of incomplete / balance work in Construction of block of cook house and dining hall (single storey), complete all as specified and shown on drawings. (Refer page No 22 and 28 )
Completion of incomplete / balance work in Construction of block of plant room/ DG set/ pump house with duty room, store and toilet (150 Sqm) (single storey), complete all as specified and shown on drawings. (Refer page No 23 and 29 )
Completion of incomplete / balance work in Construction of block of sub station building (84 Sqm) (Single storey), complete all as specified and shown on drawings. (Refer page No 23 and 30)
Completion of incomplete / balance work in Construction of RCC under ground sump 30,000 ltrs capacity, complete all as specified and shown on drawings. (Refer page No 23 and 31 )
Construction of block of covered interconnecting passage 2.40 mtr wide complete, all as specified and shown on drawings. (Refer page No 23 and 31)
Completion of incomplete / balance work in Construction of septic tank 100 users (Stone masonry), complete all as specified and shown on drawings. (Refer page No 24 and 31 )
Completion of incomplete / balance work in Construction of septic tank 10 users (Stone masonry), complete all as specified and shown on drawings. (Refer page No 29 and 31 )
Completion of incomplete / balance work in Construction of soakage well (Stone masonry) of size 1.8 m dia, 3.0 m deep, complete all as specified and shown on drawings. (Refer page No 24 and 31 )
Completion of incomplete / balance work in Construction of soakage well (stone masonry) of size 3.0 m dia, 4.50 m deep, complete all as specified and shown on drawings. (Refer page No 24 and 31 )
Construction of garbage bin with PCC block walling 20 cm thick, Complete all as Specified and shown on drawings (Refer page No 24 and 31 )
Internal Water Supply SCHEDULE 'A' PART-II Schedule ‘A’ Part- II is prepriced by MES and prepriced rates indicated under Col 5 Signifies this fact only. Bidders shall inserted their rates in green field under Col 6
Internal Electrification SCHEDULE 'A' PART-III Sec-I Schedule ‘A’ Part- III Sec-I is prepriced by MES and prepriced rates indicated under Col 5 Signifies this fact only. Bidders shall inserted their rates in green field under Col 6
Internal Electrification SCHEDULE 'A' PART-III Sec-II SCHEDULE 'A' PART-III Sec-II is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green field under column-6.
Submain wiring using two single core PVC insulated cable1100V grade with copper multi-stranded FRLS conductor of size 4 sqmm and drawing into conduit incl provision of 1.5 sqmm copper multistranded FRLS PVC insulated earth wire complete all as specified and directed. NOTE :- (i) PVC conduit and accessories shalll be measured and paid separately. (ii) Two run of 4 sqmm copper conductor each one metre and one run of earth wire, one metre together shall be measured as one metre for payment purpose.
Supply and fixing flame proof fluorescent lamp luminaire 1 x 40 W complete with all fittings incl tube light and making connections with 3 core PVC insulated copper cable of 1.0 sqmm from fittings to ceiling rose, all as specified and directed by Engr in charge.
Supply and fixing of lamp holder, insulated body with back plate for batten fitting including CFL 15 watt complete all as specified and directed.
Supply and fixing epoxy black powder coated sheet Aluminium housing with epoxy white powder coated CRCA sheet steel grey tray, clear acrylic cover, Aluminium reflector and accessories complete with 'S' type CFL 2 x 18 W suitable for security light purposes as specified, incl provision of GI bracket of 40 mm bore bent to shape , medium grade pipe 1.5 m length for fixing on walls, with clamps of FI 40x6 mm and provn of 2.5 Sq mm PVC insulated, sheathed Aluminium weather proof cable for making connnection all as specified and directed.
Earthing complete with galvanished steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl GI earth wire of size 4 mm dia (as earth lead wire) by means of nuts & bolts, check nuts and washers of galvanished iron and earth wire protected by provision of GI pipe medium grade, 15 mm bore including provision of concrete pit in PCC of 1:2:4 type B-1, using 20 mm graded crushed stone aggregates with 40 mm thick cover of RCC (1:2:4), reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos. and with 6 mm dia MS bar handle made shape, GI medium grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard / dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as shown in electrical plate No. 3 of MES SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. Note : Item of Earthing includes cost of 7.5m long GI earth wire 4.0 mm size and protection pipe of 15mm bore GI medium grade. Any variation in length shall be adjusted through deviation order based on SSR rates adjusted with quoted percentage by contractor against Sch A Part III (Sec-I)
Sub Total
Sewage Disposal SCHEDULE 'A' PART-IV Schedule ‘A’ Part- IV is prepriced by MES and prepriced rates indicated under Col 5 Signifies this fact only. Bidders shall inserted their rates in green field under Col 6
Area Drainage Works SCHEDULE 'A' PART-V Schedule ‘A’ Part- V is prepriced by MES and prepriced rates indicated under Col 5 Signifies this fact only. Bidders shall inserted their rates in green field under Col 6
Road Path and Culverts SCHEDULE 'A' PART-VI Schedule ‘A’ Part- VI is prepriced by MES and prepriced rates indicated under Col 5 Signifies this fact only. Bidders shall inserted their rates in green field under Col 6
Hot Water Supply SCHEDULE 'A' PART-VII Sec-I Schedule ‘A’ Part- VII Sec-I is prepriced by MES and prepriced rates indicated under Col 5 Signifies this fact only. Bidders shall inserted their rates in green field under Col 6
Hot Water Supply SCHEDULE 'A' PART-VII Sec-II SCHEDULE 'A' PART-V (Sec-II) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green field under column-6.
Fixing, installation, commissioning and testing of hot water generator suitable for out put 1,00,000 kilo calorie per hour complete with all accessories and comprising of following technical specifications :- Make - Alfa Term equipment Acqua Therm, Thermax , Nestler Boiler, Heiza Boilers Pvt Ltd (a) Water Outlet temp 60 degree celcius (b) Water pump of discharge 9000 LPH (c ) Calorifier fier working pressure 4 kg/hr (d) Efficiency 93% plus or minus 2% (e) Power supply 415 V 50 Hz , 3 Phase 4 wire completed with water storage and circulating MS tank 3500 liters capacity and suitable size GI pipe and fuel supply tank 300 ltrs cap with provn of pipe line network , fuel lifting pumpset incl PUF insulation to tanks, pipelines etc of suitable thickness to avoid freezing of water and fuel up to (-) 35 Degree celsisus temperature. Note :- (i) Insulation and erection of tanks will be carried out all as per direction of manufacturer's instruction. The hot water generator will be provided with a chimney of height 15 metre from ground level. (ii) Hot water generator will be issued to the contractor under Sch A Part-XIV Schedule of Credit (Old Contractor store for Incorporation in the work) any Accessories or missing items if any will be provided by contractor under this item and the cost of such accessories shall deemed to be included in the quoted rate of the bidder.
Supply and fixing kaiflex insulation tubing of size 48mm inner dia and 19 mm thick. Make : Kaiflex marketed by carewell pipes, 102 Usha Kiran Building commercial complex Azadpur Delhi.
All as per item No 9.02 above but 28mm inner dia and 19 mm thick. Make : Kaiflex marketed by carewell pipes, 102 Usha Kiran Building commercial complex Azadpur Delhi.
Earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm thickness not less than 6 mm burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to and incl GI earth lead using galvanised iron strip 32mmx 6mm size by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4 type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6 mm dia bar handle, excavation and earth work in any type of soil charcoal dust, salt, medium grade GI watering pipe 20 mm dia with funnel and wire mesh and medium grade GI protection pipe of 40 mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate no 3 of MES SSR 2009 Part-I connected main switch board all as specified and testing on completion. Note : Item of Earthing includes cost of 7.5m long GI earth strip 32x6 mm size and protection pipe of 40mm bore GI medium grade. Any variation in length shall be adjusted through deviation order based on SSR rates adjusted with percentage quoted by contractor against Sch A Part- VII (Sec-I).
Sub Total
External Electrification SCHEDULE 'A' PART-VIII Sec-I Schedule ‘A’ Part- VIII Sec-I is prepriced by MES and prepriced rates indicated under Col 5 Signifies this fact only. Bidders shall inserted their rates in green field under Col 6
External Electrification SCHEDULE 'A' PART-VIII Sec-II SCHEDULE 'A' PART-VIII Sec-II) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green field under column-6.
Supply, installation, testing and commissioning of diesel engine/driven generating Set of capacity 110 KVA, 415 volts, 0.8 PF, at NTP, mounted on base platform with flexible coupling , 1500 RPM alongwith sound proof enclosure (Acoustic enclosure ) designed for reducing the sound level to 7 + 5 of B (A) (average) IS 8528 Part-10 as per approved CPCB norms and as per GSR 371 (E) dated 17.05.2002 with silencer pipe and silencer muffler covered with asbestos rope 25mm thick independently supported from engine to outside of power house upto 1 mtr, cold start kit, battery start with suitable size of standard cables for connecting from DG set to panel board on weather condition (+) 35 degree to (-) 35 degree, DG Set shall be capable with and including the following:- (A) Prime Mover :- Diesel engine of suitable capacity water cooled (Radiator mounted) closed circuit as per BS-649 or IS-1002 direct injection type with turbo charger. Make : Cummins India Ltd/Kirloskar. The diesel engine shall be capable of running 24 hrs continuously with 10% overloading for one hrs in every 12 hrs as per BS-5514/BS 649. Engine shall be equipped with all standard fittings as per manufacturer's recommendations mounted on common base plateform through flexible coupling with following accessories :-
Srl item No. 11.01 Contd.... (a) RPM cum hours meter. (b) Battery charging ammeter. (c) lgnition key and starting with push button switch. (d) Lubricating oil pressure gauge. (e) Electronic governor controlling. (f) Toggle switch for idle running. (g) Oil temp gauge. (h) Water temperature gauge. (j) Safety controlled trip for the following:- (i) High Water temp. (ii) Low lubricating oil pressure. (iii) Over speed. (k) Lubricant oil heater to avoid freezing. (I) 24 volts starting equipment comprising of the following:- (i) 2 Nos 12V, 180 AH 25 plates battery (Make-Exide) (ii) Battery charging alternator with inbuilt regulator (iii) Starter motor of suitable capacity. (iv) Battery leads (copper stranded cable) of suitable of size with brass thimbles and terminals (Make : Kirloskar/Cummins) (B) ALTERNATOR :- Alternator of capacity 110 KVA at NTP, 415 Volts 50 C/S, 1500 RPM, 0.8 PF self excited,self regulated, screen protected with self excited field brush rotating fixed designed to be coupled with above engine through flexible coupling. The alternator shall be conformed to 4722 of BS -2613 (Make- Kirloskar/Jyoti/Crompton/NGEF/Stamford.)
Srl item No. 11.01 Contd.... (ii) Oil filter elements - 03 No. (iii) Fan belt -01 Set (iv) Hose pipe-01 Set (v) Tappet cover gasket-01 No (F) DG set shall be supplied alongwith acoustic original enclosure of the manufacturer's suitable for 110 KVA DG set as per CPCB Norms.
Earthing complete with galvanised steel earth plate electrode 600mmx600mm thickness not less than 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below normal groung level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including GI earth lead using galvanised iron strip 32mm x 6mm size by means of nuts & bolts, check nuts and washers of galvanised including PCC pit of 1:2:4 type B-1 cover reinforced with XPM weight not less than 4Kg/Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust, salt, medium grad GI watering pipe of 20mm dia with funnel and wire mesh and medium grade GI protection pipe of 40mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate No 3 of MES SSR 2009 (Part-I) connected main switch board all as specified and testing on completion. NOTE :- Item of Earthing includes cost of 7.5m long galvanised iron earth strip 32x6mm size and protection pipe of 40mm bore GI medium grade. Any variation in length shall be adjusted with quoted percentage of sch 'A' Part-VIII (Section-I)
Supply, installation, testing and commissioning LT panel board out door type platform mounting factory made totally enclosed dust vermin proof double shutter front & rear opening with locking arrangement made of 16 SWG MS sheet, shutter opened both side duly painted with two coats of synthetic enamel paint over a coat of red oxide primer paint with angle iron frame 50x50x6mm thick with necessary foundation, nuts & bolts. Panel should be complete with insulated copper conductors/PVC sleeve on bus bars with following accessories are as shown below:- (a) Copper bus bar cap, 300 Amps rating on insulator -01 No. (b) Amps meter 0to 300 Amps-01 No. (c) Voltmeter 0 to 500 volts -01 No. (d) MCCB 300 Amps - (4 pole) -01 No (incoming). (e) MCB TPN 63 Amp -06 Nos (Outgoing).
Installation, testing and commissioning LT panel board out door type platform mounting factory made totally enclosed dust vermin proof double shutter front & rear opening with locking arrangement made of 16 SWG MS sheet, shutter opened both side duly painted with two coats of synthetic enamel paint over a coat of red oxide primer paint with angle iron frame 50x50x6mm thick with necessary foundation, nuts & bolts. Panel should be complete with insulated copper conductors / PVC sleeve on bus bars with following accessories are as shown below:- (a) Copper bus bar cap, 300 Amps rating on insulator -01 No. (b) Amps meter 0 to 300 Amps-01 No. (c) Voltmeter 0 to 500 volts -01 No. (d) MCCB 300 Amps - (4 pole) -01 No (incoming). (e) MCB TPN 63 Amp -06 Nos (Outgoing). Note :- LT Panel will be issued to the contractor under Sch A Part-XIV Schedule of Credit (Old Contractor store for Incorporation in the work) any Accessories or missing items if any will be provided by contractor under this item and the cost of such accessories shall deemed to be included in the qupted rate of the bidder.
Suppy installation, testing and commissioning of LT panel board indoor type platform mounted factory made totally enclosed dust vermin proof front door & wear opening with locking arrangement made out of 16 SWG MS sheet consisting with the following:- (a) Copper bus bar capacity 300 Amps mounted on insulator - 01Set. (b) Amp meter 0-300 Amps - 01 No. (c) Voltmeter 0-500 volt - 01 No. (d) MCCB 300 Amps 4 pole - 02 Nos. (e) Change over switch 200 Amps 4 pole - 01 No.
Street light fitting HPSV 70 watts, single piece, cast aluminium housing (IP 65) with POT optics reflector including sodium vapour lamp 70 watt complete with all accessories prewired including provision of bracket of 400mm bore GI light grade pipe made to shape over all length 1.50 meter with clamps of 40 x 6mm for fixing street light fittings and providing PVC insulated conductor cable of suitable size for making connection to light fittings from junction box, complete all as specified. (Make : Crompton Greaves Cat Part No. SSG 2107 IH/WI with lamp type 70W HPSV (T) or equivalent in Bajaj/Philips)
Sub Total
External Water Supply SCHEDULE 'A' PART-IX Sec-I Schedule ‘A’ Part- IX Sec-I is prepriced by MES and prepriced rates indicated under Col 5 Signifies this fact only. Bidders shall inserted their rates in green field under Col 6
External Water Supply SCHEDULE 'A' PART-IX Sec-II SCHEDULE 'A' PART-IX Sec-II) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green field under column-6.
Supply & Fixing monoblock pumpset suitable for operation at 440 V, 50 Hz , 3 phase supply with head not less than 30 meter of capacity 5 HP. (Make : Kirloskar/ Crompton Greaves)
Installation, testing and commissioning of existing LT panel board indoor type platform mounting factory made totally enclosed dust vermin proof front door & wear opening with locking arrangement made of 16 SWG MS sheet, consisting with the following :- (a) Copper bus bar capacity 100 Amps mounted on insulator - 01 set (b) Amps meter 0 to 50 Amps alongwith CTs-01 No. (c) Voltmeter 0 to 500 volts -01 No. (d) MCCB 100 Amps, 35 KA -01 No. (e) Fully automatic star delta starter suitable for 5 HP, 3 Phase motor -02 Nos . Note :- LT Panel will be issued to the contractor under Sch A Part-XIV Schedule of Credit (Old Contractor store for Incorporation in the work) any Accessories or missing items if any will be provided by contractor under this item and the cost of such accessories shall deemed to be included in the quoted rate of the bidder.
Supply and Fixing gun metal foot valve with synthetic rubber 'O' ring screwed female and BSP tested 300 PSD , HYD of size 50mm dia. (Make : Sant / BIR)
Earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm thickness not less than 6 mm burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to and incl GI earth lead using galvanised iron strip 32mmx 6mm size by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4 type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6 mm dia bar handle, excavation and earth work in any type of soil charcoal dust, salt, medium grade GI watering pipe 20 mm dia with funnel and wire mesh and medium grade GI protection pipe of 40 mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate no 3 of MES SSR 2009 Part-I connected main switch board all as specified and testing on completion. Note : Item of Earthing includes cost of 7.5m long GI earth strip 32x6 mm size and protection pipe of 40mm bore GI medium grade. Any variation in length shall be adjusted through deviation order based on SSR rates adjusted with percentage quoted by contractor against Sch A Part- IX (Sec-I).
Sub Total
A C and Refgiration SCHEDULE 'A' PART-X SCHEDULE 'A' PART-X) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green field under column-6.
Supply and installed refrigerator , electric driven ( single phase ) capacity 310 ltrs. Make : LG/ Samsung
Supply and installed deep freezer hard top 200 ltrs cap having single door. Make :Blue star/ Voltas
Supply and install automatic voltage stabilizer suitable for operation at 230 V , 50 Hz AC supply of capacity 1 KVA including time delay arrangement. Make : Johanson/ Bluebird/ Blue line
Sub Total
Central Heating System SCHEDULE 'A' PART-XI SCHEDULE 'A' PART-XI) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green field under column-6.
GLYCOL CIRCULATION CENTRIFUGAL PUMPS : Supply, installation, testing and commissioning of monoblock centrifugal pump driven by suitable capacity electric motor for ethylene glycol of 600 LPM and 25 meter head complete with accessories including cement concerete foundation.
"Transfer Gear oil Pump (K'Oil) Self priming: Supply, installation, testing and commsissioning of Rotary Gear transfer pumps (self priming type) for capacity 15 LPM 10 ,meter head, for HSD oil complete with base frame, foundation bolts, coupling and coupling guard and TEFC FP motor (2HP), and other accessories required for commssioning (1 working + 1 standby), all specified"
GLYCOL MAKE UP CENTRIFUGAL PUMPS : Supply, installation testing and commissioning of monoblock centrifugal pump with bronze impeller, driven by suitable capacity electric motor for glycol fluid make up and mixing complete with accessories including cement concerete foundation suitable for a flow rate of 5 LPM and 5 meter head.
FLUE GAS CHIMNEY : Supply and installation of mild steel flue gas chimney made out of 3 mm thick mild steel sheet, minimum 1.20 meter above the highest point of the plant room and including connection from boiler to main chimney fabricated from 3mm MS sheet. The Item shall be complete with fixing / mounting arrangement. The portion of the chimney inside the building shall be insulated with fibre glass insulation wool of 24 Kg/Cum density. The item shall be complete with mounting/fixing arrangement.
EXPANSION TANK : Supply & Installation of overhead expansion tank of size 1500 liters cap PVC tank complete covered with 13mm closed cell electrometric insulation complete with removable lid, in/out/ drain over flow system, including mounting arrangement and complete connections.
GLYCOL FLUID TANK : Supply & Installation 1000 liters capacity PVC tank and complete with removable lid in/out/ drain over flows system, including mounting arrangement and complete connections.
BULK OIL STORAGE TANK : Supply, installation, testing, connecting with the system and commissioning of Horizontal cylindrical oil storage tank made out of mild steel. Design temperature (-) 30 0C and design pressure atmosphere + static head of liquid. (i) Storage capacity (Nominal) 5 KL (ii) Gross capacity (Not exceeding) 5.2 KL (iii) Shell thickness : 3 mm (iv) End plate thickness 4 mm Note :- Tank shall be complete with manhole, lifting lugs, earthing lugs, vent pipe dip stick inlet, outlet connections.
DAY OIL STORAGE TANK : Supply, installation, testing and commissioning of Kerosene/HSD oil day service tank, rectangular mild steel construction with capacity 990 Litres complete with inlet, outlet , drain and the tank shall be made out of 3mm mild steel sheet and will be provided with supports made out of minimum 50mm NB class 'B' pipe to keep tank base at minimum (1000mm) above finished floor level complete all as specfied. Note :- Tank shall be complete with all nozzles, manhole lifting lugs, vent pipe suitable dia inlet, outlet and return pipes with flanges as per specifications including civil works for installations and stagging as per drg.
HSD OIL PIPING : Supply, installation testing and commisioning of MS/PPR pipe including bends, reducers, flanges nuts, bolts etc complete in all respects of following sizes :-
(a) 40 mm dia pipe
(b) 25 mm dia pipe
HOT GLYCOL FLUID PIPING :Supply and laying, connecting, fixing and testing of mild steel ERW, 'C' class piping complete with fittings, duly insulated with closed cell elastomeric insulation 30 to 40 Kg/m3 density covered with shrink wrap polythene sheet for the following sizes of Hot Glycol fluid pipes. The pipes exposed to atmosphere or buried under ground will be insulated with below mentioned thick insulation
(a) 150 mm dia pipe with 16 mm thick nitrile insulation.
(b) 125 mm dia pipe with 16 mm thick nitrile insulation.
(c) 100 mm dia pipe with 16 mm thick nitrile insulation,
(d) 80 mm bore pipe with 16 mm thick nitrile insulation,
(e) 65 mm bore pipe with 16 mm thick nitrile insulation,
Supplying and laying connecting fixing and testing of poly propylene random copolymer pipes or composite pipes complete with fittings duly insulated with 13 mm thick closed cell, elastomeric insulation 30 to 40 Kg/cubic metre density for the following sizes of Hot Glycol fluid pipes
(a) 63 mm bore OD pipe
(b) 50 mm bore OD pipe
(c) 40 mm bore OD pipe
(d) 32 mm bore OD pipe
(f) 20 mm bore OD pipe
(g) Butter fly valves 100 mm
(h) Duel plate non return valves 100 mm dia
(r) Automatic air purgers valves
GLYCOL CHARGE : Supply and first fill for makeup requirement for the first year of operation of glycol concentrate along with the necessary additives and inhibitor in congnition and suppliedd in barrels. The mixture freezing temperature should be (-40 0C) all as specified.
CABLE TRAYS : Fabricating and installing, following sizes of perforated mild steel cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with mild steel suspenders and including painting ( For cabling work in plant room). 150 mm width X 50mm depth
CABLES : Supply and fixing of following sizes of insulated PVC sheathed Aluminium conductor armoured cables of 1.1 KV grade confirming to IS 1554 of following sizes :-
(a) 3 x 6 sqmm (Al)
(b) 3 x 4 sqmm (Al)
(c) 2x 4 sqmm (Al)
ELECTRICAL ACCESSORIES : Supply and fix 6 SWG dia GI wire on surface or in recess for loop earthing inter connecting main panel and other electrical equipment.
Providng "No smoking" and "Flamable" sign board as per requirement of petrolium rules and CCOE nagpur all as specified.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level, connecting to the Galvanised iron earth lead 32x 6mm size, by means of bolts, nuts, check nuts and washers of galvanised iron and 32x 6mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 meter long placed on top edge of earth plate, common salt and charcoal filling, test point made out of 40mm x 8mm Flat Iron with fixing arrangement, funnel wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No-03 of SSR-2009 Part-I and connection to earth test point all as specified or indicated including testing on completion. NOTE :- Item of Earthing includes cost of 7.5m long galvanised iron earth lead 32x6mm size and protection pipe of 40mm bore GI medium grade. Any variation in length shall be adjusted through deviation order based on SSR Rates adjusted with percentage qoted by contractor in Sch 'A' Part IX (Sec-I).
Sand cushioning to under ground electric cables all as per clause 19.75 of MES sch part-I. Note : Sand cushioning shall be fine sand as specified for plastering
Supply and laying common burnt clay cuilding sub class 'B' old size bricks, laid at right angle along the cable complete all as specified. Note : The bricks shall be laid flat butting to each other in such a way that the length of the bricks at right angle to the central axis of the cable.
Sub Total
PROTECTIVE WORK SCHEDULE 'A' PART XII Schedule ‘A’ Part- XII is prepriced by MES and prepriced rates indicated under Col 5 Signifies this fact only. Bidders shall inserted their rates in green field under Col 6
EARTH WORK SCHEDULE 'A' PART XIII Schedule ‘A’ Part- XIII is prepriced by MES and prepriced rates indicated under Col 5 Signifies this fact only. Bidders shall inserted their rates in green field under Col 6
DEFECTIVE WORK SCHEDULE 'A' PART-XIV SCHEDULE 'A' PART-XIV) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green field under column-6.
Item No 1.00 Construction of block of 12 Havs and 88 Ors (Double storey) (First Block) Note:- Srl Item No 18.02 to item No 18.44 are to be executed against the defective work of building mentioned at item No 1.00 of BoQ.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M&L Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not ecxceeding 0.11 sqm i laid over 15 mm thick screed bed in CM 1:4 as in floor etc and jointed in neat cement slurry and pointed in white or coloured cement to match.
M & L for Glazed ceramic coloured tiles of size 300x200x7 mm thick on vertical surface such as in dado/skirting/risers to steps etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over and including 15 mm thick rendering in CM (1:4), complete all as specified and directed by Engr-in-Charge.
M&L for pre-polished cut kota stone slab flooring 20-25mm thick over 20 mm thick screed bed in CM 1:6 laid over cement slurry, pointed and jointed with grey mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-charge.
M&L for pre-polished cut kota stone slab flooring 20-25mm thick as in skirting, dado over 10 mm thick cement plaster 1:6 including rubbing and polishing complete all as specified and directed by Engr-in-charge.
Demolition of PCC (un-reinforced) in ground floors including n.exc 15 CM thickness below or above ground level, complete all as specified and directed by Engr-in-Charge.
M&L PCC type C 2 1:3:6(40mm graded aggregate) 75mm thick as in Plinth Protection all as specified and directed.
S&F Flat iron steel section Fe-290 Gde E-165 as in wind ties for roof including securing bolts and all necessary drilling , bolting or riviting etc including taking out existing J hooks and refix the same position.
S&F in repair viterous China squatting pan, `Orrisa' pattern, size 580 x440 mm white, witht integral foot rests (excluding flushing cistern and flush pipe)
S&F in repair PVC valveless, syphonic action type, flushing cistern, 10 Liter capacity, low level, white, with intel, ball valve, float and handle including brackets
S&F in repair 15mm Cast copper alloy, Chromium Plated Bib taps fancy type with crutch or butterfly handle, screwed for iron pipe or for brass pipe of for ferrule and fixed
Taking down chowkats or frames n. exc 1.5 Sqm each with shutter/without taking of shutters from the frames.
Taking down chowkats or frames exc 1.5 Sqm but n.exc 4 sqm each with shutter/without taking of shutters from the frames.
S&F Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weeighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
S&F 3 mm thick sheet glass, ordinary quality and glazing in square n exc 0.50 sqm in each pane complete all as specified
S&F 5 mm thick sheet glass, ordinary quality and glazing in square exc 0.50 sqm in each pane complete all as specified
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples ,complete all as specified.
S&F 200 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed
S&F 150 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed
S&F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed
S&F 125 mm Aluminium handles, cast type, anodised and fixed
S&F 100 mm Aluminium handles, cast type, anodised and fixed
S&F 100 mm Butt hinges, medium weight, cold rolled mild steel, and fixed
S&F 75 mm Aluminium handles, cast type, anodised and fixed
S&F in repair 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work complete all as specified and directed.
S&F in repair 9 mm thick prelaminated particle board as in ceiling, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work complete all as specified and directed.
S&F Bonded mineral wool blanket slab made from glass density 24kg/cu m and fixed as per maker's instructions, 50mm thick complete all as specified.
Demolition of cement concrete (reinforced) in Roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended work Complete all as specified and directed as Engr-in-charge.
M & L for RCC M 30 design Mix using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for flat fair finished surface of concrete.
M & L for TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
Taking up PVC mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead.
S&F 75mm Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, in walls complete all as specified
S&F 100mm Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, in walls complete all as specified
S&F in repair Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete typee B1 (1:2:4). Note :- This item requires the taking down of existing PVC floor trap and S&F of CI floor trap as indicated above.
S&F 75mm dia Cast iron Bends, laid and jointed, complete
S&F 75mm dia Cast iron `Y' junctions laid and jointed, complete
S&F 100mm dia Cast iron `Y' junctions laid and jointed, complete
S&F 100mm dia Cast iron Slotted vent cowl, complete
Sub Total
Item No 1.01 Construction of block of 12 Havs and 88 Ors (Double storey) ( Second Block ) Note:- Srl Item No 18.46 to item No 18.88 are to be executed against the defective work of building mentioned at item No 1.01 of BoQ.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M&L Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm i laid over 15 mm thick screed bed in CM 1:4 as in floor etc and jointed in neat cement slurry and pointed in white or coloured cement to match.
M & L for Glazed ceramic coloured tiles of size 300x200x7 mm thick on vertical surface such as in dado/skirting/risers to steps etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over and including 15 mm thick rendering in CM (1:4), complete all as specified and directed by Engr-in-Charge.
M&L for pre-polished cut kota stone slab flooring 20-25mm thick over 20 mm thick screed bed in CM 1:6 laid over cement slurry, pointed and jointed with grey mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-charge.
M&L for pre-polished cut kota stone slab flooring 20-25mm thick as in skirting, dado over 10 mm thick cement plaster 1:6 including rubbing and polishing complete all as specified and directed by Engr-in-charge.
Demolition of PCC (un-reinforced) in ground floors including n.exc 15 CM thickness below or above ground level, complete all as specified and directed by Engr-in-Charge.
M&L PCC 1:3:6 type C 2 (using 40mm graded crushed stone aggregate) 75mm thick as in Plinth Protection all as specified and directed.
S&F Flat iron steel section Fe-290 Gde E-165 as in wind ties for roof including securing bolts and all necessary drilling , bolting or riviting etc including taking out existing J hooks and refix the same position.
S&F in repair viterous China squatting pan, `Orrisa' pattern, size 580 x440 mm white, witht integral foot rests (excluding flushing cistern and flush pipe)
S&F in repair PVC valveless, syphonic action type, flushing cistern, 10 Liter capacity, low level, white, with intel, ball valve, float and handle including brackets
S&F in repair 15mm Cast copper alloy, Chromium Plated Bib taps fancy type with crutch or butterfly handle, screwed for iron pipe or for brass pipe of for ferrule and fixed
Taking down chowkats or frames n. exc 1.5 Sqm each with shutter without taking of shutters from the frames.
Taking down chowkats or frames exc 1.5 Sqm but n.exc 4 sqm each with shutter/without taking of shutters from the frames.
S&F Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weeighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppyling & fixing in the frame at site as per specification & drawing.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing.
S&F 3 mm thick sheet glass, ordinary quality and glazing in square n exc 0.50 sqm in each pane complete all as specified
S&F 5 mm thick sheet glass, ordinary quality and glazing in square exc 0.50 sqm in each pane complete all as specified
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and averae width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified.
S&F 200 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed, complete all as specified.
S&F 150 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed, complete all as specified.
S&F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed
S&F 125 mm Aluminium handles, cast type, anodised and fixed
S&F 100 mm Aluminium handles, cast type, anodised and fixed
S&F 100 mm Butt hinges, medium weight, cold rolled mild steel, and fixed
S&F 75 mm Aluminium handles, cast type, anodised and fixed
S&F in repair 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work complete all as specified and directed.
S&F in repair 9 mm thick prelaminated particle board as in ceiling, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work complete all as specified and directed.
S&F Bonded mineral wool blanket slab made from glass density 24kg/cu m and fixed as per maker's instructions, 50mm thick complete all as specified.
Demolition of cement concrete (reinforced) in Roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended work Complete all as specified and directed as Engr-in-charge.
M & L for RCC M 30 design Mix using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for flat fair finished surface of concrete.
M & L for TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
Taking up PVC mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead.
S&F 75mm Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, in walls complete all as specified
S&F 100mm Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, in walls complete all as specified
S&F in repair Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete typee B1 (1:2:4). Note :- This item requires the taking down of existing PVC floor trap and S&F of CI floor trap as indicated above.
S&F 75mm dia Cast iron Bends, laid and jointed, complete
S&F 75mm dia Cast iron `Y' junctions laid and jointed, complete
S&F 100mm dia Cast iron `Y' junctions laid and jointed, complete
S&F 100mm dia Cast iron Slotted vent cowl, complete
Sub Total
Item No 1.02 Block of Common and Study Room ( Single storey ) Note:- Srl Item No 18.90 to item No 19.16 are to be executed against the defective work of building mentioned at item No 1.02 of BoQ.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M&L for pre-polished cut kota stone slab flooring 20-25mm thick over 20 mm thick screed bed in CM 1:6 laid over cement slurry, pointed and jointed with grey mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-charge.
M&L for pre-polished cut kota stone slab flooring 20-25mm thick as in skirting, dado over 10 mm thick cement plaster 1:6 including rubbing and polishing complete all as specified and directed by Engr-in-charge.
S&F Flat iron steel section Fe-290 Gde E-165 as in wind ties for roof including securing bolts and all necessary drilling , bolting or riviting etc including taking out existing J hooks and refix the same position.
Taking down chowkats or frames n. exc 1.5 Sqm each with shutter without taking of shutters from the frames.
Taking down chowkats or frames exc 1.5 Sqm but n.exc 4 sqm each with shutter without taking of shutters from the frames.
S&F Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weeighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitings such as peg stays 150mm long (1 No.) hinge type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified
S&F 3 mm thick sheet glass, ordinary quality and glazing in square n exc 0.50 sqm in each pane complete all as specified
S&F 5 mm thick sheet glass, ordinary quality and glazing in square exc 0.50 sqm in each pane complete all as specified
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and averae width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified.
S&F 200 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed
S&F 150 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed
S&F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed
S&F 125 mm Aluminium handles, cast type, anodised and fixed
S&F 100 mm Aluminium handles, cast type, anodised and fixed
S&F 100 mm Butt hinges, medium weight, cold rolled mild steel, and fixed
S&F 75 mm Aluminium handles, cast type, anodised and fixed
S&F in repair 9 mm thick prelaminated particle board as in ceiling, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work complete all as specified and directed.
S&F Bonded mineral wool blanket slab made from glass density 24kg/cu m and fixed as per maker's instructions, 50mm thick complete all as specified.
Taking down cement or cement-lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
M&L 5 mm thick rendering on ceiling of concrete surface in cm 1:3 complete all as specified and directed.
M&L 12 mm thick rendering on fair faces of brick work or concrete surface in cm 1:4 to be finished even and smooth without using extra cement complete all as specified and directed.
Demolition of PCC (un-reinforced) in ground floors including n.exc 15 CM thickness below or above ground level, complete all as specified and directed by Engr-in-Charge.
M&L PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) 50mm thick as in floor, all as specified and directed.
M&L PCC 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) 75mm thick as in Plinth Protection, all as specified and directed.
Sub Total
Item No 1.03 Block of Cook House and Dinning Hall (Single storey ) Note:- Srl Item No 19.18 to item No 19.44 are to be executed against the defective work of building mentioned at item No 1.03 of BoQ.
Demolition of PCC (un-reinforced) in ground floors including n.exc 15 CM thickness below or above ground level, complete all as specified and directed by Engr-in-Charge.
M&L PCC 1:3:6, type C 2 (using 40mm graded crushed stone aggregate) 75mm thick as in Plinth Protection all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M&L for pre-polished cut kota stone slab flooring 20-25mm thick over 20 mm thick screed bed in CM 1:6 laid over cement slurry, pointed and jointed with grey mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-charge.
M&L for pre-polished cut kota stone slab flooring 20-25mm thick as in skirting, dado over 10 mm thick cement plaster 1:6 including rubbing and polishing complete all as specified and directed by Engr-in-charge.
S&F Flat iron steel section Fe-290 Gde E-165 as in wind ties for roof including securing bolts and all necessary drilling , bolting or riviting etc including taking out existing J hooks and refix the same position.
Taking down chowkats or frames n. exc 1.5 Sqm each with shutter/without taking of shutters from the frames.
Taking down chowkats or frames exc 1.5 Sqm but n.exc 4 sqm each with shutter/without taking of shutters from the frames.
S&F Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weeighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S&F 5 mm thick sheet glass, ordinary quality and glazing in square exc 0.50 sqm in each pane complete all as specified
S&F 200 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed
S&F 150 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed
S&F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed
S&F 125 mm Aluminium handles, cast type, anodised and fixed
S&F 100 mm Aluminium handles, cast type, anodised and fixed
S&F 100 mm Butt hinges, medium weight, cold rolled mild steel, and fixed
S&F 75 mm Aluminium handles, cast type, anodised and fixed
S&F in repair 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work complete all as specified and directed.
S&F in repair 9 mm thick prelaminated particle board as in ceiling, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work complete all as specified and directed.
S&F Bonded mineral wool blanket slab made from glass density 24kg/cu m and fixed as per maker's instructions, 50mm thick complete all as specified.
M & L for RCC M 30 design Mix using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for flat fair finished surface of concrete.
M & L for TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
Dismantling of plain or corrugated CGI/PGI steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.63mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as speciified and as directed
Sub Total
Item No 1.04 Block of Plant room / DG Set / Pump House with Duty Room, Store and Toilet (Single storey ) Note:- Srl Item No 19.46 to item No 19.57 are to be executed against the defective work of building mentioned at item No 1.04 of BoQ.
Demolition of PCC (un-reinforced) in ground floors including n.exc 15 CM thickness below or above ground level, complete all as specified and directed by Engr-in-Charge.
M&L PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) 50mm thick as in floor all as specified and directed.
M&L PCC 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) 75mm thick as in Plinth Protection all as specified and directed.
Taking down chowkats or frames exc 1.5 Sqm but n.exc 4 sqm each with shutter/without taking of shutters from the frames.
S&F Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weeighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S&F 3 mm thick sheet glass, ordinary quality and glazing in square n exc 0.50 sqm in each pane complete all as specified
S&F Flat iron steel section Fe-290 Gde E-165 as in wind ties for roof including securing bolts and all necessary drilling , bolting or riviting etc including taking out existing J hooks and refix the same position.
S&F 150 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed
S&F 100 mm Aluminium handles, cast type, anodised and fixed
S&F 75 mm Aluminium handles, cast type, anodised and fixed
Sub Total
Item No 1.05 Block of Sub Station Building (Single storey ) Note:- Srl Item No 19.59 to item No 19.61 are to be executed against the defective work of building mentioned at item No 1.05 of BoQ.
Demolition of PCC (un-reinforced) in ground floors including n.exc 15 CM thickness below or above ground level, complete all as specified and directed by Engr-in-Charge. NOTE : Plinth protection and floor damaged.
M&L PCC type C 2 1:3:6(40mm graded aggregate) 75mm thick as in Plinth Protection all as specified and directed.
S&F Flat iron steel section Fe-290 Gde E-165 as in wind ties for roof including securing bolts and all necessary drilling , bolting or riviting etc including taking out existing J hooks and refix the same position. NOTE : Wind Ties not provided.
Sub Total
Item No 1.06 RCC Under Ground Sump 30000 Litres Capacity Note:- Srl Item No 19.64 to item No 19.66 are to be executed against the defective work of building mentioned at item No 1.06 of BoQ.
Taking down cement or cement-lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. NOTE : External plaster damaged.
M&L 12 mm thick rendering on fair faces of brick work or concrete surface in cm 1:4 to be finished even and smooth without using extra cement complete all as specified and directed.
Sub Total
Item No 1.07 Block of Covered Interconnecting Passage 2.4 Metre Wide Note:- Srl Item No 19.68 to item No 19.70 are to be executed against the defective work of building mentioned at item No 1.07 of BoQ.
Demolition of cement concrete (reinforced) in Roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended work Complete all as specified and directed as Engr-in-charge.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for Complete all as specified and directed as Engr-in-charge.
Sub Total
Schedule A Part-III Section-I (List of Items of Work and Prices for Internal Electrification) Note:- Srl Item No 19.72 to item No 19.75 are to be executed against the defective work of Sch 'A' Part-III Sec-I (Internal Electrification).
Point wiring including taking down old point wiring with 1.5 Sq mm copper conductor FRLS (Multi strand) PVC ISI Mark unsheathed cabledrawn through existing concealed conduit pipe of any size including PVC insulated ISI mark unsheathed 1.5 Sq mm copper multi stranded conductor FRLS as earth wire connected to common earth dolly and incl sunk cost iron/ pressed steel terminal boxes, junction boxex, other boxes made from 1.60 mm thick sheet of suitable sizes for mounting of switches, sockets, fan regulator, light fittings etc covered with 3 mm thick plastic laminated sheet (make Hylum or equivalent ISI marked) for one light point or one fan point or one bell point or one combination multipurpose, one 3 pin 5 Amps socket outlet independent or one bell / controlled by one switch / push button, complete all as specified and directed. Note :- Any items broken/ made defective during execution shall be changed by contractor at no cost.
All as per srl item No 19.72 above , but for one 3 pin 5 Amp socket on the independent board with other switches, all as spd and directed
All as per srl item No 19.72 above , but with 2.5 sqmm copper conductor FRLS ( Multistrand) and PVC insulated unsheathed 1.5 sqmm copper conductor as earth wire for one 3 pin 15 A socket outlet independent , all as spd and dierctedfor one 3 pin 5 Amp socket on the samet board with other switches, all as spd and directed
Sub Total
Schedule A Part-III Section-II (List of Items of Work and Prices for Internal Electrification) Note:- Srl Item No 19.77 to item No 19.78 are to be executed against the defective work of Sch 'A' Part-III Sec-II (Internal Electrification).
Supply and fixed in repair energy efficient T-5 Fluorescent Tube Light fitting suitable for and incl tube rod 1 x 14 W complete with electronic ballast, capacitors, spring loaded rotor type, lamp holders, starter holders, starter, connector block, etc and all accessories pre wired complete and as directed. Make :- Bajaj Cat Part No BJHL 114 T5 SL or of equivalent in Crompton Greaves and Philips.
Sub Total
Schedule A Part-XI (List of Items of Work and Prices for Central Heating System) Note:- Srl Item No 19.80 to item No 20.04 are to be executed against the defective work of Sch 'A' Part-XI (Central Heating System).
Reinstallation, testing & commissioning after repairing with including providing missing / defective parts for Oil fired glycol based hot water generator (boiler) using kerosene/ HSD oil complete with combustion chamber and equipment automatic monoblock burner assembly tubes primary pump, control panel with sequence controller, photo cell for flame failure, HT transfer electrodes, blower assembly, electric panel pressure gauges, therometers, mounting frame suitable for operation on 50 Hz, 3 phase 415 volts A C supply and all as specified and recommended by manufacturer, Hot water inlet temp = 650 C Hot water outlet temp = 750 C Air changes 1.5 naturally capacity - 4,00.000 K Cal/hr at MSL
M&L for Dismantling of Existing Pipe of any size and make complete all as specified.
HOT GLYCOL FLUID PIPING :Supply and laying, connecting, fixing and testing of mild steel EWR, class 'C' piping complete with fittings, duly insulated with closed cell elastomeric insulation 30 to 40 Kg/m3 density covered with shrink wrap polythene sheet for the following sizes of Hot Glycol fluid . The pipes exposed to atmosphere or buried under ground will be insulated with below mentioned thick insulation:-
(a) 150 mm bore pipe with 16 mm thick nitrite insulation
(b) 125 mm bore pipe with 16 mm thick nitrite insulation
(c) 100 mm bore pipe with 16 mm thick nitrite insulation
(d) 80 mm bore pipe with 16 mm thick nitrite insulation
(e) 65 mm bore pipe with 16 mm thick nitrite insulation
Supplying and fixing elastomeric insulation on existing PPR pipe and testing of poly propylene random copolymer aluminium foiled pipes or composite pipes complete with fittings duly insulated with 13 mm thick closed cell, eleastomeric insulation 30 to 40 Kg/M3 density for the following sizes of Hot glycol fluid pipes :-
(a) 63 mm bore OD pipe
(b) 50 mm bore OD pipe
(c) 40 mm bore OD pipe
(d) 32 mm bore OD pipe
(e) 25 mm bore OD pipe
(g) Butter fly valves 100 mm dia
(j) Balancing valves 65mm
(k) Butter fly valves 80 mm dia
(l) Balancing valves 100mm dia
(m) Balancing valves 80mm dia
(n) Ball valves 25 mm dia
(o) Inlet/Outlet valves for FCU's
(p) Pressure gauges will cocks and syphon
(q) Water flow switch
(r) Automatic air pumping pipe
Fixing only of Inlet / Outlet valves for FCUs Note :- These items are available at site.
Fixing installation, testing and commissioning of decorative wall mounted fan coil unit complete with top grills, EVS casing complete all as specified and directed Note:- 1. These items are available at site. 2. Any Accessories or missing items if any will be provied by contractor under this item and the cost of such accessories shall deemed to be included in the quoted rate by the bidder.
Fixing only Pressure guage with cock and Syphon duly insulated with 13 mm thick closed shell elastomeric insulation 30 to 40 Kg/m3 Density. Note:- These items are available at site.
Supplying Fixing connecting and testing of water flow switch.
Supplying Fixing connecting and testing of Butterfly valve 100mm dia includung taking down existing valve.
Supplying Fixing connecting and testing of Balancing valve 65mm.
Supplying Fixing connecting and testing of Butterfly valve 80mm dia includung taking down specified existing valve.
Supplying Fixing connecting and testing of Balancing valves 100mm dia includung taking down existing valve.
Supplying Fixing connecting and testing of Balancing valves 80mm dia includung taking down existing valve.
Supplying Fixing connecting and testing of automatic Air Purger Valve.
Sub Total
Schedule Of Credit SCHEDULE 'A' PART-XIV) SCHEDULE 'A' PART-XIV)Schedule of Credit ( Old Contractors Store For Incorporation in the Work) The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 1620528.35 and any other reduction if any from quoted amount.
Schedule Of Credit SCHEDULE 'A' PART-XV) SCHEDULE 'A' PART-XV)Schedule of Credit ( Old Contractors Store and T&P Not For Incorporation in the Work) The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 347841.00 and any other reduction if any from quoted amount.
Schedule Of Credit SCHEDULE 'A' PART-XVI) SCHEDULE 'A' PART-XVI)Schedule of Credit ( Not For Incorporation in the Work) for unserviceable items to be taken on credit against the defective works. The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 220870.00 and any other reduction if any from quoted amount.
M/S ZAILDAR ENTERPRISES (BID ID -3390405)
Intrernational Engineers (BID ID -3385309)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .