Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹43.4 LAccepted-AOC | 1 | Accepted-AOC 1st lowesr |
Tender Value
₹43.8 L
EMD Value
₹50,000
Closing Date
28 Nov 2023, 5:00 pmClosed
Executive Engineer
WS Division NTA
Jal Jeevan Mission (JJM)-al Jeevan Mission - CWSS to Ottasekharamangalam - Water supply line extension amp providing water connections from existing and proposed pipelines to households of Ottasekharamangalam Grama Panchayath. (Phase-2)-Design Suply
2023_KWA_622808_1
RE-E-Tender49/2023-24/WSD/NTA
Open Tender
Civil Works - Water Works
Item Rate
120 days
Neyyattinkara
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,760
Yes
₹50,000
Yes
20 Jan 2024
17 Nov 2023
30 Nov 2023
17 Nov 2023
28 Nov 2023
17 Nov 2023
Amount
Construction of OH Tank
2.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)
OD100192/2023-2024:Supply and Providing MS dowel bars of size 20mm dia of 2.0mt long (1mt in roack and 1mt in Concrete) including drilling hols of 25mm dia and filling gap with cement grout (0.50kg/each) etc complete.
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
OD127577/2023-2024:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve work ability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :-Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @340 kg/cum). Extra for providing and mixing water proofing material in cement concrete in doses by weight of cement as per manufacturer's specification. No Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.-above plinth level
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
13.4.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.
OD127857/2023-2024:Design charge of structural and designing of RCC over head tank
OD127795/2023-2024:Supply and fixing 150mm CI Wall casting pipe
OD127809/2023-2024:Supply and fixing 80mm Fabricated Wall Casting pipe including fixing charges.
OD127802/2023-2024:Fabricating 65mm GI Tee with using went pipe welding charges and fixing all labour charges.
OD127943/2023-2024:Labour engaged for conveying concrete materials like cement sand aggerate steel etc.(Up to 100mt)
12.41.1:Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.75 mm diameter
Supply & fixing centrifugal pumps, Pumping main & Distribution line
2.1.1:Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
OD127983/2023-2024: Supply, Installation of high head CF booster pump, 3 phase, 65 mt head, 7LPS ( Considering available pumping hours of 8 Hours due to valve controlling) with warranty for 2 years for the date of commissioning, The rate includes, cost of pump, cost of motor, cost of dry run preventer, cost of panel board, cost of soft starter, cost of suitable pressure gauge 2 nos, starter, Aluminium cable from panel board to starter and starter to motor, cost of capacitor, 65mm GI (Class-B) suction pipe minimum 5 mt length foot valve, Non return and sluice valve pipe connection work for suction and delivery side, earthing as per IE rule, Errection charges including foundation, base plate, cost of cement sand and meter, trail run and commissioning etc. complete as per the direction of engineer in charge. Protection cover for booster pump, KYOSK for placing the energy meter and panel board accessories.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
OD100324/2023-2024:Protecting Cover for Booster pump, KYOSK with metel roof for placing the energy meter starter and panel board accessories etc comlplete.as per the direction of Dept officers.
OD100334/2023-2024:OYEC amount for taking connection to the Booster pump house near Anakuzhi colony including CD, Inspection charges etc. complete
OD100335/2023-2024:Supply and installation of module for mobile starter for motor including SIM
OD100354/2023-2024:Inter connection and making 65mm GI/MS Flanged bend for connecting existing 75mm PVC line to 65 mm Suction pipe with Flanges all all labour and materials charges etc complete
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
15.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.11:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outside diameter pipes.
100.31.2.1:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 80mm diameter, Class II.
100.31.2.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class II.
100.32.1:Conveying and fixing C. I. Single Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 25mm Single Acting Air Valve.
100.32.3:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 50mm Double Acting Air Valve.
100.98.239:Supply of PVC Pipe, 10kg/cm2, 160mm Dia.
OD100511/2023-2024:Cost of 10kg PVC Specials
100.98.440:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm.
100.98.457:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.
100.98.460:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm.
18.19.5.1:Providing and fixing gun metal non-return valve of approved quality (screwed end): 65 mm nominal boreHorizontal
100.98.446:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Double Orifice Type DS2, Size 50mm.
OD127870/2023-2024:Fabricating 150/150x 50mm MS Flanged Tee including Fabrication Charge Cutting ,Grinding Welding cost of Flange all labour charges etc complete
OD127871/2023-2024:Supplying & Fixing 50mm CI/GM Flanged Sluice valve for fixing Isolation of 50mm Air Valve including fixing charge
18.17.1:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
OD100513/2023-2024:Supply of 150mm CID Joint-(Class-15)
OD100514/2023-2024:Supply of 80mm CID Joint-(Class-15)
OD100484/2023-2024:Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling, such Tee, bend, flanges etc complete . External work 150 mm dia nominal bore class B Pipe excluding charge of Tar/Concrete cutting-(weight 19.5kg/mt)
OD127904/2023-2024:Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling, such Tee, bend, flanges etc complete . External work 80 mm dia nominal bore class B Pipe excluding charge of Tar/Concrete cutting-(weight 8.47 kg/mt)
OD100505/2023-2024:Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling, such Tee, bend, flanges etc complete . External work 65 mm dia nominal bore class B Pipe excluding charge of Tar/Concrete cutting-(weight 6.10 kg/mt)
OD133251/2023-2024:Labour engaged to Joining the 150/80mm GI Pipe with flanges and IR sheet nut and bolt, primer and painting the welded portion ete complete. excluding charge of flanges.
OD100486/2023-2024::Providing labour engaged for lifting pipe and related other materials.( Head Load )
OD100488/2023-2024:Inter connection from Newly laid 150/160mm Pipe to existing 75mm PVC Pipe with all specials labour charges etc complete.
OD100515/2023-2024:Labour engaging fixing Sluice/ Non return/Air valves and related other works
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
OD100489/2023-2024:Providing and fixing Plastic Fully Automatic Water Level and Over flow Controller with One Float Switch sensor, Three Phase
OD100497/2023-2024:Supplying laying 4 core 1M2 mm UG cable by control of automatic water controller and laying ,cost of cable charge etc complete.
Construction of Valve Chamber
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
OD100518/2023-2024:Supply and providing heavy duty MH cover with frame of size 560mm dia (Weight minimum 208.kg)
Bidder Name
SHIBU C
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_937546.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .