Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹22.8 L+₹2.9 L (14.7%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹37.8 L+₹17.9 L (90.3%)Rejected-Finance H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L3 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
14 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
REPAIR/REPLACEMENT OF CERTAIN PARTS OF SUMMER AND WINTER APPLIANCES INCLUDING REPAIR/REPLACEMENT OF SECURITY LIGHTS, GARDEN LIGHTS AND CONNECTED ITEMS AT RAJOURI UNDER GE 862 EWS
2023_MES_623255_1
GER-63/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
As per tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹99,800
Yes
22 Dec 2023
14 Oct 2023
16 Nov 2023
14 Oct 2023
14 Nov 2023
30 Oct 2023
Amount
REPAIR TO GEYSER Taking down/ dismantling of defective/rusted storage type hot water heater/ Geyser of 50/35/25 Ltr capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts such as glass wool, element, water tank, flange assembly, gasket of any type, nuts/bolts, clamp by unscrewing bolts and nuts, de-scaling/cleaning internally and externally including checking for leakage in tank and rectification by gas welding as required etc. Checking defects, re-assembling and re-installing the Geyser in position after complete servicing, connection and testing to entire satisfaction of Engr-in-Charge. Note:-(i) Cost of gas welding, nuts/bolts, clamps, shall be deemed to be included in the quoted rate by tenderer. (ii) Replacement of unserviceable parts shall be measured and paid separately under respective items.
Supply and fixing in replacement of Heating element 2.0 KW (ISI marked) round/triangle shape, complete all as specified and directed.
Supply and fixing in replacement of Heating element 1.0/1.5 KW (ISI marked) round/triangle shape, complete all as specified and directed.
Supply and fixing in replacement of Heating element 3.0 KW (ISI marked) (for solar water heater), complete all as specified and directed.
S&F in replacement for PVC insulated and sheathed multi - staranded flexible wire 3 core with Copper conductor 2.5 Sqmm round type for Geyser, complete all as specified and directed.
S&F in replacement for Thermostat of range 60-90 degree centigrade adjustable type operative on 240 volts, complete all as specified and directed.
S&F in replacement for Indication lamp (Green/Red) round/ square as per requirement, complete all as specified and directed.
S&F in replacement of Inner tank made out of stainless steel of standard gauge suitable for 25/35 litres capacity geyser make as approved by GE, complete all as specified and directed.
S&F in replacement of Inner tank made out of stainless steel of standard gauge suitable for 50 litres capacity geyser make as approved by GE, complete all as specified and directed.
S&F in replacement of geyser syphon assemble chromimum plated suitable for 50 ltr capacity geyser ISI marked, complete all as specified and directed.
S&F in replacement of geyser syphon assemble chromimum plated suitable for 25/35 ltr capacity geyser ISI marked, complete all as specified and directed.
S&F in replacement PVC connection 15mm dia (heavy duty) with two nos of brass adaptor and washer of size 450mm to 600mm long for hot/cold water suitable for geyser, complete all as specified and directed.
S&F in replacement for sheet metal enclosure with socket plug top and MCBs single pole with one MCB 240 volts 20 amps, complete all as specified and directed.
REPAIR TO CEILING/EXHAUST FAN Taking down/ dismantling complete ceiling fan of size 1200/1400 mm sweep and, exhaust fan/pedestal fan/air ciculating fan any sweep from various building (or collecting from MES E/M store yard), opening up for servicing /repair , removing dust and dirt, cleaning fan motor with cotton/waste malmal, washing blades with detergent powder, greasing to serviceable bearings, checking of nuts , bolts, washer, rubber buff, split pin, condensor, MS clamps, rubber packing, condensors block, rubber reel etc for any damages and replacement of damaged and unserviceable items for the smooth and satisfactory functioning, refixing fans etc in same position connecting to electric system and testing, complete all as specified and directed. (Note :- Replacement of damaged /unserviceable part shall be measured and paid separetaly).
Rewinding of AC ceiling fan motor 240 volts, 50Hz, 1200/1400mm sweep of any make with super enameled copper winding wire of existing size including sleeve work , varnishing with 'B' class insulation varnish, connection with flexible copper wire of 0.472mm dia upto connector block including cutting down and removing complete burnt winding after inspection, complete all as specifid and directed. Note:- (i) Motor shall be wound with machine with same No of turns as per existing. (ii) Make of copper winding as approved by GE.
Rewinding of exhaust fan motor 240 volts, 50Hz, 300mm sweep of any make with super enameled copper winding wire of existing size including sleeve work , varnishing with 'B' class insulation varnish, connection with flexible copper wire of 0.472mm dia upto connector block including cutting down and removing complete burnt winding after inspection complete all as specifid and directed. Note:- (i) Motor shall be wound with machine with same No of turns as per existing. (ii) Make of copper winding as approved by GE.
Rewinding of exhaust fan motor 240 volts, 50Hz, 450mm sweep of any make with super enameled copper winding wire of existing size including sleeve work , varnishing with 'B' class insulation varnish, connection with flexible copper wire of 0.472mm dia upto connector block including cutting down and removing complete burnt winding after inspection, complete all as specifid and directed. Note:- (i) Motor shall be wound with machine with same No of turns as per existing. (ii) Make of copper winding as approved by GE.
S&F in replacement for Capacitor AC 415 volts 3.15 MFD 50 Hz, complete all as specified and directed.
S&F in replacement for Capacitor AC 415 volts 2.5 MFD 50 Hz, complete all as specified and directed.
S&F in replacement for fan blade set of 1200/1400mm sweep ceiling fan (as per sample colour/white), complete all as specified and directed.
S&F for PVC insulated and sheathed multi - staranded flexible wire 3 core with Copper conductor 1.5 Sqmm for connecting connector block to ceiling rose and making connection, complete all as specified and directed.
S&F in replacement for upper/lower canopy of 1200/1400mm sweep ceiling fan (as per sample) colour as per existing fan colour, complete all as specified and directed.
S&F in replacement for PCB (printed control board) and sensor for BLDC motor ceiling fan, complete all as specified and directed.
S&F in replacement for exhaust fan of 300mm sweep, heavy duty, 1200 RPM electrical operated 230 Volts AC single phase, made with sturdy engineering plastic with all accessories and louver etc, complete all as specified and directed.
REPAIR TO REFRIGERATOR Dismantling of refrigerator of any make & capacity in various location, shifting it to MES yard and taking out compressor/condensor/freezer unit etc for repair/ replacement of unserviceable parts, cleaning condensor/ freezer units from foreign particles and descaling with carbon dioxide gas to ensure smooth flow of refrigerent gas, reassembling the appliances, testing and placing in position and sticking a sticker mentioning the “No, Date of servicing, Due date, CA No., Contractor’s name, user’s signature’ and shifted to existing location, complete all as specified and directed by Engineer-in-Charge. (NOTE: Replacement of unserviceable spare parts shall be measured and paid separetaly.
S&F in replacement hermetically sealed compressor unit 1/8 HP for 165/175 Ltr capacity of refrigerator of existing make/ model in the unit, complete all as specified and directed.
S&F in replacement hermetically sealed compressor unit 1/6 HP for 280/310 Ltr capacity of existing make and model of refrigerator, complete all as specified and directed.
S&F in replacement for PCB (printed control board) and sensor for refrigerator, complete all as specified and directed.
Supply & filling of refrigerant gas R-134A of required quantity including detection and rectification of leakage before charging of gas into compressor including replacement of filters of any type, complete all as directed by Engr-in-charge.
S&F in replacement of copper capillary tube and stainer for any type and capacity of refrigerator, complete all as specified and directed by Engr-in-charge.
S&F in replacement of starting relay for domestic refrigerator of any capacity, complete all as specified and directed by Engr-in-charge.
S&F in replacement of over load protection for referigerator of any type and capacity, complete all as specified and directed by Engr-in-charge.
S&F in replacement of thermostat for refrigerator of any type/capacity, complete all as specified and directed by Engr-in-charge.
REPAIR TO WATER COOLER Dismantling of water cooler of any make & capacity in various location, shifting it to MES yard and taking out compressor/condensor/freezer unit etc for repair/ replacement of unserviceable parts, cleaning condensor units from foreign particles and descaling with carbon dioxide gas to ensure smooth flow of refrigerent gas, reassembling the appliances, testing and placing in position and sticking a sticker mentioning the “No, Date of servicing, Due date, CA No., Contractor’s name, user’s signature’ and shifted to existing location, complete all as specified and directed by Engineer-in-Charge. (NOTE: Replacement of unserviceable spare parts shall be measured and paid separetaly.
S&F in replacement hermetically sealed compressor unit 1/6 HP for 80/120/150 Ltr capacity water cooler of existing make/ model in the unit, complete all as specified and directed.
Supply & filling of refrigerant gas R-22 of required quantity including detection and rectification of leakage before charging of gas into compressor including replacement of filters of any type, complete all as directed by Engr-in-charge.
S&F in replacement of copper capillary tube for any type and capacity of water cooler, complete all as specified and directed by Engr-in-charge.
S&F for starting capacitor 60/80 MFD 230 volts AC for water cooler capacity 80/120/150 ltrs including taking out old unserviceable starting capacitor, complete all as specified and directed by Engr-in-charge.
S&F for running capacitor suitable for water cooler of capacity 80/120/150 ltrs including taking out old unserviceable running capacitor, complete all as specified and directed by Engr-in-charge.
S&F for thermostat suitable for water cooler of 80/120/150 ltrs capacity including taking out old unserviceable thermostat, complete all as specified and directed by Engr-in-charge.
S&F for starting relay suitable for water cooler of 80/120/150 ltrs capacity including taking out old unserviceable relay, complete all as specified and directed by Engr-in-charge.
REPAIR TO AC WINDOW TYPE Dismantling the window type AC of capacity in 1.5 Ton in various location, shifting it to MES Yard and taking out compressor/condensor unit/blower motor etc for repair/replacement of unserviceable spares parts and cleaning condensor unit from foreign particles, cleaning of filter (if not replaced) of window type AC of any capacity by vacuum cleaner/water spray/mild liquid soap cleaning the front grill by soft cleanser (Colin etc) and sticking a sticker mentioning the ‘No, Date of servicing, Due date, CA No., Contractor’s name, user’s signature’ reassembling, testing, checking and shifted to existing location, fixing the same by thermocol, ply wood, wooden bit, complete all as directed and specified by Engineer-in-Charge. (NOTE: Replacement of unserviceable spare parts shall be measured and paid separetaly.
M&L for complete servicing of window type AC of capacity in 1.5/2 Ton at various locations disconnecting setting aside cleaning dust particles with blowers and cleaning the condensor fins with chemical and finally with water, reassembling, testing and fixing the same by thermocol, ply wood, wooden bit at same location, complete all of the satisfaction of Engr-in-Charge.
S&F in replacement hermetically compressor sealed unit with referigerant gas of suitable capacity / model in the unit properly for 1.5 Ton window type AC, complete all as specified and directed by Engr-in-charge.
S&F blower fan motor double shaft, 3 speed, single phase, AC, 1/5 HP, 920 RPM, 220 Volts as per existing make of window type AC 1.5 Ton including taking out old unserviceable blower with fan motor, complete all as specified and directed by Engr-in-Charge.
S&F in replacement for starting capacitor 100/120 MFD 230 V AC for window type AC 1.5 Ton capacity, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Starting relay (SR-1622) suitable for window type AC 1.5 Ton capacity, complete all as specified and directed by Engr-in-Charge.
S&F in replacement strip type heater (M-type), 2KW for window type AC 1.5 ton capacity as per existing make and model, complete all as specified and directed.
S&F for running capacitor 36 MFD, 230 V for window type AC 1.5 Ton capacity, complete all as specified and directed by Engr-in-Charge.
REPAIR TO AC SPLIT TYPE Dismantling the split type AC of capacity 1.5 to 2 Ton in various location, shifting it to MES Yard and taking out compressor/condensor unit/blower motor etc for repair/replacement of unserviceable spares parts and cleaning condensor unit from foreign particles, cleaning of filter (if not replaced) of split type AC of any capacity by vacuum cleaner/water spray/mild liquid soap and sticking a sticker mentioning the ‘No, Date of servicing, Due date, CA No., Contractor’s name, user’s signature’ reassembling, testing, checking and shifted to existing location, complete all as specified and directed by Engineer-in-Charge. (NOTE: Replacement of unserviceable spare parts shall be measured and paid separetaly.
M&L for complete servicing of split type AC of capacity in 1.5/2 Ton at various locations disconnecting setting aside cleaning dust particles with blowers and cleaning the condensor fins with chemical and finally with water, reassembling, testing and fixing at same location, complete all of the satisfaction of Engr-in-Charge.
S&F in replacement condensor fan motor per existing make/model of split type AC 1.5/2 Ton, complete all as specified and directed by Engr-in-Charge.
Rewinding blower motor with super enameled copper winding wire of standard gauge including replacement of ball bearing, insulating material for existing make/model of split type AC 1.5/2 Ton capacity, complete all as specified and directed by Engr-in-Charge.
S&F in replacement for PCB (printed control board) dual mode and sensor for split type AC 1.5/2 Ton, complete all as specified and directed.
S&F in replacement of running capacitor 40/50 MFD capacity, 230 Volts for split type AC 1.5 / 2.0 ton capacities, complete all as specified and directed.
S&F in replacement hermetically sealed compressor unit for 1.5/2 ton capacity split type AC of existing make/ model, complete all as specified and directed.
REPAIR TO DEEP FREEZER Dismantling of deep freezer of any make & capacity in various location, shifting it to MES yard and taking out compressor/condensor/freezer unit etc for repair/ replacement of unserviceable parts, cleaning condensor/ freezer units from foreign particles and descaling with carbon dioxide gas to ensure smooth flow of refrigerent gas, reassembling the appliances, testing and placing in position and sticking a sticker mentioning the “No, Date of servicing, Due date, CA No., Contractor’s name, user’s signature’ and shifted to existing location, complete all as specified and directed by Engineer-in-Charge. (NOTE: Replacement of unserviceable spare parts shall be measured and paid separetaly.
S&F in replacement hermetically sealed compressor unit 1/6 HP for 310 Ltr capacity of deep freezer of existing make/ model, complete all as specified and directed.
S&F in replacement of starting relay suitable for deep freezer of any capacity, complete all as specified and directed by Engr-in-charge.
S&F in replacement of over load protection for deep freezer of any type make and capacity, complete all as specified and directed by Engr-in-charge.
S&F in replacement of thermostat for deep freezer of any make and capacity, complete all as specified and directed by Engr-in-charge.
S&F in replacement of filter suitable for deep freezer of any make and capacity, complete all as specified and directed by Engr-in-charge.
S&F in replacement of condensor fan motor suitable for deep freezer of any make and capacity, complete all as specified and directed by Engr-in-charge.
S&F in replacement for indoor unit of the split type Air conditioner 1.5 TR capacity having 3 star rating with all accessories such as, insatallation plate with screws, blower motor, swing motor, filters, hot and cold mode facility and PCB etc. duly pre-wired and including connection to existing refrigerant gas piping, electrical connections, drain pipe etc. and testing, complete all as specified and directed by GE when required.
S&F in replacement of voltage stabilizer 12 Amps, Single phase, 240 volts, AC, 50 Hz of working range 170 volts-270 volts, time delay 3 minutes +/- 2.5 %, wall mounting type, complete all as specified and directed by GE as and when required.
S&F in replacement of voltage stabilizer 15 Amps, Single phase, 240 volts, AC, 50 Hz of working range 170 volts-270 volts, time delay 3 minutes +/- 2.5 %, wall mounting type, complete all as specified and directed by GE as and when required.
Dismantaling of split type AC of capacity 1.5/2 Ton from the existing position and shifting the same to the new altered location, complete indoor and outdoor units, refrigerent tubing, MS stand, stabilizer and cable etc including tesing after installation, complete all as directed by Engr-in- charge.
Repairs to industrial type RO plant of capacity 100 liters per hour of any type and make by dismantling and carry out servicing, descaling and overhauling and making functional after throughly examine/checking all components, inlet and outlet piping system, pressure meter, auto flushing (solenoid valve), automatic ON/OFF, indicators and anti scalant dosing system etc and replacement of spare parts/components viz 100 GPD membrane, filter set, adoptor, motor, solenoid valve, and pipe coupling set and testing for its performance, complete all as specified and directed. Note:- (i) 100 GPD membrane, filter set, adopter, motor, solenoid valve shall be measured and paid sepretely as supply only.
Supply only 100 GPD membrane suiltable for reverse osmosis (RO) plant of capacity 100 liters per hour of existing make and model of RO plant, complete all as specified and directed.
Supply only filter set suiltable for reserve osmosis (RO) plant of capacity 100 liters per hour of existing make and model of RO plant, complete all as specified and directed.
Supply only adopter suiltable for reserve osmosis (RO) plant of capacity 100 liters per hour of existing make and model of RO plant, complete all as specified and directed.
Supply only solenoid suiltable for reserve osmosis (RO) plant of capacity 100 liters per hour of existing make and model of RO plant, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10sqm on plan for laying of cable and foundation of poles stays and getting out in soft / loose soil, complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm (soil) thickness, complete all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable, complete all as specified and as directed. (Note: Punned thickness of sand shall be measured and paid).
M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed.
M&L for PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete of poles and stay/installation paths, complete all as specified and directed.
M&L for plain cement concrete type C-1 , 1:3:6 (using 20mm graded stone aggregate) as in coping of poles, benching, hold fasts, water troughs, bed block and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and directed.
Supply, laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply, laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply, laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
S&F in replacement of LED Bollard light 8 watt, cone shaped intigral decorative with polycarbonate diffuers, outdoor type, IP 65 protection including all accessories and internally prewired including necessary fixing aarangement such as clamps, brackets, nut bolts reducer etc fixed on PCC platform in PCC 1:2:4 and making electrical connection with copper cable, complete all as specified and directed.
S&F in replacement of LED post top lantern light fitting 25 watts with cast aluminium spigot lid cover and clear acrylic cover with IP65 protection complete with all accessories including fixing arrangement on top surface of boundary wall or on pillar by providing GI pipe of suitable size and length as per site requirement and making good the distrubed portion to match with existing surface, complete all as specified and directed.
S&F in replacement of LED street light fitting 45 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting, complete all as specified and directed.
S&F in replacement of LED street light fitting 60 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting, complete all as specified and directed.
S&F in replacement of 70 watt LED flood light luminaire outdoor type with thermal management in multiple optics and equiped with IP-66 protection with impact and corrosion resistant complete with driver and lamp and all accessories duly prewired and including fixing arrangement such as clamps, nuts, bolts, and washers etc on poles/wall surfaces etc at any height, complete all as specified and directed.
S&F in replacement of 120 watt LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium of IP-66 protection complete with all accessories duly prewired and including fixing arrangement on high mast poles/wall surfaces etc at any height providing clamps, nuts, bolts, and washers etc, complete all as specified and directed.
S&F for FRP looping box of size 200x140x95 with aluminium bus bar (04 Nos) 100 Amps capacity connector and comprising oF MCB SP 6 Amps, ISI marked 240 V, 'C' series/curves complete with including providing GI calmps, nuts bolts etc suitable for fixing on PCC pole/wall/steel tubular poles etc after taking down old unserviceable looping box of any type, complete all as specified and directed.
S&F for copper conductor cable, PVC insulated, sheathed flexible, multistranded ISI marked 1100 volts grade 3 core 1.5 sqmm and including connection and testing and after taking down old unserviceable copper conductor cable, complete all as specified and directed.
Supply, fixing and testing of LED street light drivers of 30-120 watt capacity, IP-66 as required on site as per existing make of strret light, complete all as specified and directed.
M/S PARSHOTAM KUMAR GUPTA
M/S A K ENGINEERS & CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .