Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.4 LAccepted-AOC PLOT NO 4 NAYA GAON HARIPUR KANWALI P O SEEMADWAR DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹54.8 L+₹6.9 L (14.4%)Rejected-Finance 133 SADAK DUDHLI SAHARANPUR 247001 UP | SAHARANPUR | UTTAR PRADESH | 247001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | Rejected-Technical 2523 B LANE NO 3 TURNER ROAD DEHRADUN 248002 | DEHRADUN | UTTARAKHAND | 248002 | - | Rejected-Technical Not fulfilling the eligibility criteria |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
19 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Clement Town
GE Clement Town MES Dehradun
COMPREHENSIVE MAINTENANCE OF OTM AND MD ACCN OF NHO AND HQ CWE (HILLS) DEHRADUN UNDER AGE B/R-III OF GE CLEMENT TOWN
2023_MES_607224_2
GE /CLT/ of 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Clement Town
Class D Cat a(i)
6 documents required · 6 mandatory
₹500
Yes
GE Clement Town
₹98,000
Yes
23 Dec 2023
23 Sept 2023
21 Oct 2023
23 Sept 2023
19 Oct 2023
30 Sept 2023
Amount
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed.
Dismantling wall & ceiling boards (fibre, insulation etc ) or insulation boards, slabs, blankets any thick ness including cover fillets complete all as specified and directed.
Dismantling timber scantling 40 Sqcm and over in section in any position complete all as specified and directed.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down cement plaster of any description on brick work or stone masonry walls including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size n.exc 1.50 Sqm complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size exc 1.5 Sqm and n.exc 4 Sqm complete all as specified and directed.
Taking down shutter of any description exc. 1 sqm but not exc. 2 sqm each complete all as specified and directed.
Taking down shutters exc 1 Sqm and n.exc 2 Sqm of any description and refixing in same opening/position include cutting for size and fitting including making good of distrub area complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/springclips and providing and fixing new one complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed.
Taking up or down 20mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed.
M&L for cleaning and removing all scales and dirt etc from tanks and from mouths of circulating pipes of capacity exc 250 & n exc 500 ltrs complete all as specified and directed.
M&L for cleaning and removing all scales and dirt etc from tanks and from mouths of circulating pipes of capacity exc 500 & n exc 1000 ltrs complete all as specified and directed.
M&L brick work with sub class "B" old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L for half brick work with subclass ‘B’ bricks, straight or curved on plan to any radius built in CM 1:4 complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.50mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
M&L 50mm thick PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) as in plinth protection /hardstanding , laid in panels, finished the top surfaces even and fair without using extra cement complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed.
M&L RCC (1:2:4) type B-1 (Using 20mm graded stone aggregate) as in slabs, shelves supported on walls, beams and columns in floor or roof including balconies, cooking platform ,canopies, deck slabs or in Chajja/facia projection and the like complete all as specified and directed.
M&L mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for fair finished surfaces (Horizontal or sloping) complete all as specified and directed.
M&L Vitrified coloured tiles 8-10mm thick any Shade/Double charged (square/rectangular) area of each tiles exc 0.18 Sqm but not exc 0.42 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:6 laying floor finishes, complete all as specified and directed.
M&L Vitrified coloured tiles 8-10mm thick Dark Shade/Double charged (square/rectangular) area of each tiles exc 0.18 Sqm but not exc 0.42 Sqm as in vertical surface such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 to recieve tiles complete all as specified and directed.
M&L for Non skid Endura coloured tiles 10-12 mm thick (square/rectangular) , area of each tile exc 0.06 Sqm but not exc 0.11 Sqm over and including 15mm thick screed bed in Cement mortar (1:6) in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
M&L for Non skid Endura coloured tiles 10-12mm thick (square/rectangular) , area of each tile exc 0.06 Sqm but not exc 0.11 Sqm as in vertical surface such as dado/ skirting etc over and including 10mm thick screed bed in Cement mortar (1:4) in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
M&L for joint free Non-skid ceramic coloured tiles 7-8mm thick (square/rectangular), area of each tile not exc 0.11 Sqm, over and including 15mm thick screed bed in CM (1:6) in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
M&L for Glazed ceramic coloured joint free tiles 450x300X7mm in vertical surfaces over and including 10mm thick rendering in Cement mortar (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) stone slab as in steps, jambs, pillars, window-cills, cooking platforms and like over and including cement screed bed 15mm thick in CM (1:6) including pointing in white cement (1:2) using marble dust to match with marble shade complete all as specified and directed.
S&F 30mm thick factory made flush shutter solid core construction with block board core and ply wood face panels, commercial type both sides complete all as specified and directed.
S&F in repair powder coated aluminium glazed side hung double door shutters with anodised aluminium frame of section 100x44x1.5mm and shutter having style, top rail, lock rail and bottom rail of 84x44x1.5mm including 5.5mm thick tinted blind sheet glass ordinary quality with all necessary suitable push & pull plate/handle, screw, jointing cleats, rubber packing, aluminium snap beading and 1 No 200mm long Al tower bolt in each shutter, 100 mm long 3 No Al butt hinges B-21 type in each shutter, and one No mortice brass lock 100mm size 6 leaver (vertical type) complete all as specified and directed.
S&F Factory made 100% Solid WPC Brown door Frame (75mm x 50mm Single Rebate) made from 100% LEAD FREE (single extruded process) material with density 780 kg/Cum & Manufactured by an ISO: 9001-2015 certified company, all as per specification drawing as directed by the Engineer-in-Charge. The door frame should be Waterproof, Termite Proof, Fire Retardent and having excellent screw holding capacity complete all as specified and directed.
S&F Factory made 100% Solid WPC Brown door Frame (100mm x 63mm Single Rebate) made from 100% LEAD FREE (single extruded process) material with density 780 kg/Cum & Manufactured by an ISO: 9001-2015 certified company, all as per specification drawing as directed by the Engineer-in-Charge. The door frame should be Waterproof, Termite Proof, Fire Retardent and having excellent screw holding capacity complete all as specified and directed.
S&F Factory made 100% Solid WPC Brown door Frame (125mm x 63mm Double Rebate) made from 100% LEAD FREE (single extruded process) material with density 780 kg/Cum & Manufactured by an ISO: 9001-2015 certified company, all as per specification drawing as directed by the Engineer-in-Charge. The door frame should be Waterproof, Termite Proof, Fire Retardent and having excellent screw holding capacity complete all as specified and directed.
S&F 24mm thick Moulded WPC Brown Factory made 100% Solid door (Conforming as Per IS:4020) made from 100% LEAD FREE single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with Wood Grain Texture and back side plain with density not less than 600 kg/cum. Manufactured by an ISO: 9001-2015 certified company. The door should be Waterproof, Termite Proof, Fire Retardent and having screw holding capacity complete all as specified and directed.
S&F 30mm thick Moulded WPC Brown Factory made 100% Solid door (Conforming as Per IS:4020) made from 100% LEAD FREE single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with Wood Grain Texture and back side plain with density not less than 600 kg/cum. Manufactured by an ISO: 9001-2015 certified company. The door should be Waterproof, Termite Proof, Fire Retardent and having screw holding capacity complete all as specified and directed.
S&F 30mm thick Factory made Wiremesh SOLID WPC(Wood Plastic composit) moildede gauged door shutter with wire mesh in any number of division with brown wood grain texture, including S.S wire mesh shall be fixed with 15 x 15 square tube in side rails with screwing 8x28 heat metal zinc coated screws can be removed or fix again after changing of wire mesh when needed. The density of the door shall be as per manufacture instruction complete all as specified and directed.
S&F three track Pre coated Steel Sliding Window System fabricated from roll formed sections made of Galvanized Steel Colour Coated/ Powder Coated (Base Steel as per IS 513 “D” quality, galvanized as per IS 277 with Zinc of 120 grams/ Sq. Mtr.) with total coated thickness of 0.58 mm or Powder Coated with pure Polyester Powder up to 50-60 microns thick. Windows Section for three track external frame should be of 44 x 107mm , Section for window glass shutter should be of 36 x 50 mm, if required Section for shutter horizontal mullion should be 22mm x 60mm, The windows should be paneled with 5mm thick Plain Float glass Gaskets are to be made with Ethyl Propylene Diamine Manomer (EPDM). Corner brackets for internal and external frame made of Polypropylene. Touch lock to be provided for window shuttes Sections are to be cut to length, joined and assembled by means of corner brackets. The above Frame should be fixed to brick/ concrete masonry by using Nylon self-expanding caps and driving MS electroplated 80mm long screws into the caps through frames.Windows shall be provided with fixed Stainless steel 32gauge wire mesh/gauze of 304grade with 144 holes per square inch for mosquito proofing with the help of nut, bolt and flat iron of 20x3mm size on top and Grill made of 12mm MS Square bars welded to 25x4mm angle iron . Distance between bars should not be more than 100mm centre to centre. Total Grill and wire mess unit shall be powder coated.Assembling and installation of windows and ventilators shall be all as per details shown/mentioned on drawings and as per manufacturer‟s instructions complete all as specified and directed.
S&F Pre coated Steel fixed type Window/ Ventilator fabricated from roll formed sections made of Galvanized Steel Colour Coated/ Powder Coated (Base Steel as per IS 513 “D” quality, galvanized as per IS 277 with Zinc of 120 grams/ Sq. Mtr.) with total coated thickness of 0.58 mm or Powder Coated with pure Polyester Powder up to 50-60 microns thick. The windows should be paneled with 5mm thick frosted glass Gaskets are to be made with Ethyl Propylene Diamine Manomer (EPDM). Corner brackets for internal and external frame made of Polypropylene. The above Frame should be fixed to brick/ concrete masonry by using Nylon self-expanding caps and driving MS electroplated 80mm long screws into the caps through frames. Windows shall be provided with Grill made of 12mm MS Square bars welded to 25x4mm angle iron . Distance between bars should not be more than 100mm centre to centre. Total Grill shall be powder coated.Assembling and installation of windows and ventilators shall be all as per details shown/mentioned on drawings and as per manufacturer‟s instructions complete all as specified and directed.
S&F Window/ventilator prepainted section of frame 72x55mm fixed to wall or concrete surface with rawl plugs made of galvanised steel powder coated and section of shutter 47x20mm, mulion section 72x50mm (Base steel as per IS 513 "D" quality galvanized as per IS 277 with zinc of 120 gms/Sqm) glazed and wire gauge shutter prepared to receive wiremesh to the shutter (Double shutter) with total coated thickness of 0.6mm including grills/guard bars made made of 12mm square bars powder coated fixed to window frame with screws at 100mm c/c both ways, 4 mm thick sheet glass, 0.36mm stainless steel wire cloth with 1.4mm aperture and necessary fittings and all builders hardware such as handles, tower bolts & stays etc complete all as specified and directed.
S&F Aluminium powder coated three track sliding windows (with three sliding shutters, (One with and incl stainless steel wire mess and two with and incl 4mm thick sheet glass panes) aluminium sections not less than 1.1kg per meter for bottom track and top track and side track 0.98 kg per metre, bottom shutter frame 0.55 kg per metre, top shutter frame 0.47 kg per metre, shutter sides, 0.47 kg per metre and interlock sides 0.45 kg per metre including suitable nylon beading channel gasket, nylon rollers Maruthi lock with handles etc complete all as specified and directed. Windows shall be provided with guard bars using 25mm flat iron and 10mm square bars of design including painting of guards bars, complete all as specified and directed.
S&F in repair 18mm thick WPC board one side prelaminated and other side plain white colour as in cup boad shutters and frames, kitchen cabinet front shutter, partion, shelf & drawer, fixed with screws, solvent cement/ adhesive complete all as specified and directed.
S&F of 100mm long stainless steel butt hinges, medium weight cold rolled complete all as specified and directed.
S&F 150mm long, Stainless Steel barrel tower bolts complete all as specified and directed.
S&F 100mm size Stainless Steel handles, all as directed complete all as specified and directed.
S&F 150mm size Stainless Steel handles, all as directed complete all as specified and directed.
S&F of 250mm long (Length of bolt) Stainless Steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, and fixing bolts and sliding bolt complete all as specified and directed.
S&F 150mm Stainless Steel Hasp and Staple, including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F in repair Hydrulic Self Closing hinges 35mm of crank( KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters complete in all respect and fixed in position complete all as specified and directed.
S&F aluminium section for modular kitchen partition incl fixing with cleats complete all as specified and directed.
S&F 18 m thick with min density 600kg/cum LEAD FREE PVC celuka ply of both side plain white fixed with SS screws solvent cement/ adhesive to make kitchen cabinet, shelves as per manufacturers instruction complete all as specified and directed.
S&F in repair 16 to 18 mm thick pre laminated TESA ACTION shutter ultra voilet coated panels of intrior grade type II with melamine finish of approved shade for kitchen cabinet fixing with necessary fittings (like keku fitting, spring clip, hanger plate, modular hinges) all as specified and directed including taking down of old cupboard/ cabinet shuttr complete all as specified and directed.
S&F set of 6 modular kitchen stainless steel basket , pull out drawers, shelves cabinet, rack basket tray for multipurpose utensil containers shelf organiser complete including all fittings and side sliding rails complete all as specified and directed.
S&F in repair door closer aluminium (extruded section) body hydraulically regulated, designation No. 3, universal type, complete all as specified and directed.
S&F in repair 300mm long MS Helical ordinary rat tail rod pattern door spring including roller and roller plate etc complete of approved quality complete all as specified and directed.
S&F in repair of 140mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, Overall length of cover plate complete all as specified and directed.
S&F in repair 4mm thick plain glass of aluminium window by taking down window shutter by any means and replacing rubber packing, jointing clip etc. complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty or fixed with cut and mitred beads in squares or triangular n.exc. 0.5 sqm each pane complete all as specified and directed.
S&F 25mm dia drapery rod fancy type powder coated wooden finish fixed to wall with wooden finale and brackets incl ends doms complete all as specified and directed.
S&F Dust/Snake guard aluminium strip in doors of size 40x2mm with rubber at strip bottom complete all as specified and directed.
M&L 15mm thick rendering in cement mortar (1:6) on brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L 15mm thick rendering cement mortar (1:4) mixed with liquid water proofing compound on brick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed. (WPC shall be paid seperately)
M&L for 10mm thick plaster on roof, chajja and roof parapet of CM (1:3) on RCC finished even and smooth without using extra cement etc ncl taking down cement plaster complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
M&L for three coats of white wash to newly plastered surfaces of ceiling including preparation of surfaces, complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of 2mm thick wall putty to newly plastered surface including preparation of surfaces complete all as specified and directed.
M&L two coats of cement based paint over a coat of primer to newly plastered surfaces of wall including preparation surfaces complete all as specified and directed.
M&L for preparation of old surface by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white wash on walls surface including salt, glue and blue etc. as required including cleaning of glass panes, floor and plinth protection complete all as specified and directed.
All as per item No. 71 above but two coats of white wash on wall surfaces complete all as specified and directed.
All as per item No. 71 above but one coat of white wash on ceiling surface complete all as specified and directed.
M&L for preparation old surfaces of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of oil bound distemper on walls including cornices, pilasters etc complete all as specified and directed.
Ditto all as per item No.74 here in above but on ceiling surfaces complete all as specified and directed.
M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper using roller over a layer of wall care putty to make the surface smooth all as specified and prescribed by manufacturer of paint complete all as specified and directed. Note:- (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE before application of distemper for each building. (v). The colour / shade will be all as approved by GE.
M&L for preperation of old decorated/painted surfaces of walls by washing, rubbing down and stoping painted surfaces and applying one coat of plastic emulsion paint complete all as specified and directed.
M&L preperation of old painted concrete/tile floor surfaces of any description includig scraping, brushing, brooming down and repair surface with Primer and applying two coat of Indigo emulsion floor paint any tint / shade over a coat of primer complete all as specified and directed.
M&L preperation of old painted plastered surfaces of any description and applying one coat of exterior emulsion paint (Apex) of asian paint or other equivelent as approved complete upto four storey height complete all as specified and directed. Note : The work is required to be carried out upto 4th storey building. The cost of scaffolding shall be deemed to be included in the item. The contractor shall also make necessary safety arrangement for labour
M&L for preparation of old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint (wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint complete all as specified and directed. Note :- (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are demand to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE before application of distemper for each building. (v). The colour / shade will be all as approved by GE. (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor.
M&L for preparation surface of old wall by washing,rubbing down and stopping of surfaces and applying one coat of cement base paint on walls complete all as specified and directed.
M&L for preparation surface of old wall by washing,rubbing down and stopping of surfaces incl complete removal of existing treatment and applying two coat of cement base paint on walls complete all as specified and directed.
M&L for preparation surface of old wooden surfaces over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
All as per item No.83 above but applying two coat of synthetic enamel paint on wooden surfaces complete all as specified and directed.
M&L preperation of old painted steel and iron surfaces of any description not otherwise described over 10cm width of girth and applying one coat of synthetic enamel paint (any tint/shade) complete all as specified and directed.
M&L for preperation of old painted plastered or concrete surfaces of any description and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L two coats of weather proof emulsion paint Apex in newly plastered surface over a coat of primer incl preparing the surface with 2mm thick wall putty complete all as specified and directed.
M&L for applying two coats of french polish on wooden surface complete all as specified and directed.
S&F 15mm bore dia of medium grade galvanised steel tubing with all fittings including tank nipple and fixed complete to wall or laid in floor including cutting through walls, floors, etc and their making good with existing surface complete all as specified and directed.
S&F 20mm bore dia of medium grade galvanised steel tubing with all fittings including tank nipple and fixed complete to wall or laid in floor including cutting through walls, floors, etc and their making good with existing surface complete all as specified and directed.
Refixing of old steel tubing and connections in new or old position with all fittings to floor, wall or ceiling for 15mm bore GI tubing complete all as specified and directed.
Refixing of old steel tubing and connections in new or old position with all fittings to floor, wall or ceiling for 20mm bore GI tubing complete all as specified and directed.
Cutting chases, pinning in, making good to facing where required and pointing in Cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water pipe etc and making good, cutting not exc 10cm width or girth complete all as specified and directed.
S&F in repair 15mm dia gun metal gate valve with iron wheel haeded screwed both ends to iron pipe and fixed complete all as specified and directed.
S&F in repair 20mm dia gun metal gate valve with iron wheel haeded screwed both ends to iron pipe and fixed complete all as specified and directed.
S&F in repair 110mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches/floor or fixed to wall including necessary clamps complete all as specified and directed.
S&F in repair 75mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches/floor or fixed to wall including necessary clamps complete all as specified and directed.
S&F in repair 75mm dia PVC (SWR) floor trap with grating including jointing with solvent cement including fixing waste pipe etc complete all as specified and directed.
S&F in repair PVC (SWR) junction single, (Single T) equal or unequal 110mm bore with access door complete all as specified and directed.
S&F in repair PVC (SWR) junction single, (Single T) equal or unequal 75mm bore with access door complete all as specified and directed.
S&F in repair PVC (SWR) bend any radius 110mm bore complete all as specified and directed.
S&F in repair PVC (SWR) bend any radius 75mm bore complete all as specified and directed.
S&F in repair PVC (SWR) bend any radius 110mm bore with access door complete all as specified and directed.
S&F in repair PVC (SWR) bend any radius 75mm bore with access door complete all as specified and directed.
S&F in repair PVC vent cowls 75mm complete all as specified and directed.
S&F in repair PVC connection 15mm bore dia 450mm long with 2 Nos PTMT nuts with washer complete all as specified and directed.
S&F in repair PVC waste pipe 32/40 mm dia complete all as specified and directed.
S&F in repair 20mm dia brass CP tubular towel rail D type 600mm long complete all as specified and directed.
S&F in repair brass CP bib tap 15mm bore fancy type screwed for iron pipe complete with wall flange complete all as specified and directed.
S&F in repair 15mm bore Stop valve fancy type, chromium plated with long shunk and cup (concealed type) high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified and directed.
S&F in repair 15mm dia brass chromium plated pillar tap long body with fly nut capstan head screwed for 15mm bore dia of pipe complete all as specified and directed.
S&F in repair chromium plated brass shower roses with or without swivel joints 125mm size including shower arm complete all as specified and directed.
S&F in repair of Sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm and bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repair 15mm dia brass CP wall mixer with provision for over head shower with 115mm long bend pipe and wall flange for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repair 15mm dia brass CP Sink mixer with swinging spout (wall mounted model) with connecting legs and wall flanges screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repair 15mm Brass CP wash hand basin mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repair CP health faucet with 1m flexible tube and wall hook complete all as specified and directed.
S&F in repair CP angular stop cock 15mm dia single way and fixed complete all as specified and directed.
S&F in repair PTMT bath mirror cabinet of overall size 500mm x 400mm, fixed in position complete all as specified and directed.
S&F in repair CP toilet paper holder fixed to wall with CP brass screws complete all as specified and directed.
S&F in repair Sheet glass shelf assembly/Glass Corner assembly set of three consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F in repair Vitreous china wash hand basin including brackets, white size 550 x 400 mm incl cutting cutting for and pinning in ends of brackets. Including Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and directed.
S&F in repair Vitreous china squatting pan ‘Orissa pattern’ size 580x440mm white with integral foot rest including connection to trap, and flushing pipe, anti-syphonage pipe, etc and including lime concrete bedding complete all as specified and directed.
S&F in repair 10 Litre capacity PVC low level flushing cistern with ball valve and handle/push button 32mm dia PVC flush pipe including taking down unserviceable cistern complete all as specified and directed.
S&F Vitreous china wash down water closed pan (Pedestal pattern) white, including connection to drain (or out going pipe) and to flush pipe, antisypthonic (excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F in repair Vitreous china white wash down couple closet composite type including PVC soft seat cover white complete all as specified and directed.
S&F in repairs PVC seat cover for wash down couple closet including fixing bolts complete all as specified and directed
S&F in repairs Kitchen Plate rack with and including shelves and hanging arrangement for utensil for kitchen, made of stainless steelsheet 0.63mm thick size 24"x24"x10" complete all as specified and directed.
S&F in repairs PVC water storage tank double layer cylindrical, vertical with closed top with threaded cover hoisted and fixed in position tank capacity 500 Ltr with and including ball valve high pressure of PTMT with epoxy coated Aluminum rod and high density plastic ball screwed for 20mm bore of iron pipe and making connection for inlet and outlet including dismantle of old water tank and removing from site complete all as specified and directed.
S&F in repairs PVC water storage tank double layer white colour cylindrical, vertical with closed top with threaded cover hoisted and fixed in position tank capacity 1000 Ltr with and including ball valve high pressure of PTMT with epoxy coated Aluminum rod and high density plastic ball screwed for 25mm bore of iron pipe and making connection for inlet and outlet including dismantle of old water tank and removing from site complete all as specified and directed.
S&F in repair 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gram) complete all as specified and directed.
M&L for concrete in Sunken floor and vertical faces of walls to ease up about corners with cement concrete 1:2:4 type B0 (using 12.50mm stone aggregate) mixed with SBR Latex liquid polymer (mixed as per manufacture instructions & will be paid under relivnt item of Sch A) including using form work (straight or curved) as required complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B-1 for fixing edge of interlocking tiles and rounded or chamfered edges, coping complete all as specified and directed.
S&F False Ceiling with Semi perforated 10mm thick Square edged GRG False Ceiling tiles at all heights with GRG (Glass Fiber Reinforced Gypsum) false ceiling tiles of size 595 x 595mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Nomocombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120grams per Sqm incliuding both sides) comprising of main-T runners of size 15x32mm of length 3000mm, cross-T of size 15x32mm of length 1200mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per Sqm) i.e. 50mm lon, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod up to 1000mm length and L-shape level adjuster os size 85x25x2mm. Galvanized iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450mm centre to centre and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing complete all as specified and directed.
S&F 6mm thick PVC heavy grade hollow profile designer sheet strips & channel feathered at edges of approved quality and design PVC Wall/Ceiling lining fixing with frame including all beading, matching PVC angles at all window corners with all necessary frame as required complete all as specified and directed.
Chipping ,removing carefully concrete work by low impact hammer ,breaker without damaging the structure & cleaning and disposal of debris out side the premises etc. complete all as specified and directed.
Dismantling, Removing carefullly Concrete work by low impact Hammer ,Breakar without damaging the structure & cleaning and disposal of debris out side the premises etc. complete all as specified and directed.
M & L for clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete, Applying two coats of alkaline rust converting primer FEOVERT of Krishna Conchem of Roff rust cleaner of Piddilite or Dr Fixit Rust removal or sholirust of STP Ltd. on the rebars,including cleaning the reinforcement ,wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry complete all as specified and directed.
M & L for providing and fixing additional steel bar or stirrups of diameter in variuos structural elements like columns,beams and foundations including drilling,bending and fixing the bars with epoxy putty etc complete all as specified and directed.
M & L for carry out application of ‘Bi-polar migratory corrosion inhibitor' EPCO-KP-100 on concrete surface. This inhibitor has migratory kind of property which permits the material to migrate to a virtual extent of 100 mm, through pores of concrete, inhibiting the corrosion and de-passivating the Electro-chemical reaction. It has property to attack anode as well as cathode, which is purely alkaline in nature (pH-9.5), so it has no carcinogen activity with concrete complete all as specified and directed.
M & L for applying two coats of anticorrosive Treatment to Reinforcement by application of two coats of anti-rust protective coating in the form of Acrylic Polymer with a minium splid content to 40% solid mixed with cement in 1:1.5 proportion ( 1 part polymer and 1.5 part cement) on rebars after cleaning of rust scales with time interval of minimum 4 hours between each coat by brush as per manufacturers instruction. Anti-rust protective shall be procured from one of manufacturer given below.
M & L for providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete complete all as specified and directed.
M & L for providing and applying jacketing around columns,beams,slabs,chajjas etc with Micro concrete (molith-MC) M40 including all lifts, shuttering,drilling holes and fixing shear anchor as per specification complete all as specified and directed. Note: Reinforcement shall be measured and paid separately (Rates including jacketing, formwork and micro concrete)
M & L for building up the profile of structural members by using latex B2 modified air cured mortar system in damaged areas (1Cement-3 part graded cleaned pre-packed river sand 10% latex mortar by weight of cement-0.5 w/c ratio) upto 20 mm to 40 mm thickness including leveling profiling and removing and cleaning existing vegetation growth in structural and Non structural items all complete etc. complete all as specified and directed.
M & L for providing and Casting in position a mix of (M30 Grade) made clean sharp aggregates 10 mm down along with addition of Non shrink admixure including transporting, mixing, laying, curing, etc complete all as specified and directed.
M & L for centering and shuttering including struttings, propping etc. and removal of formwork in 12 mm thick plywood, including application of shuttering oil, etc. for fair finished surface complete all as specified and directed.
M&L for 20mm thick rendering in CM 1:4 with the addition of Shaliplast LW+ @ 200ml per bag of cement on fair faces of brick or concrete surfaces complete all as specified and directed.
M&L for preparation of new or old concrete surface of RCC Over head Tank incl complete removal of existing treatment and applying two coats of asian Apex or equivalent over a coat of primer complete all as specified and directed.
M&L for preparation of old steel surfaces and applying two coats of synthetic enamel paint complete all as speciifed and directed. Note for item No. 137 to 150 :- Work has to be carried out on Over head tank upto 21.00 m height. Contractor has to made his arrangement of necessary scaffolding , safety arrangement etc.
Dismantling and taking down carefully U/S copper / aluminium point wiring (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified & directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates. (ii) If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down carefully sub-main wiring/service wire of any size including wooden batten etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified & directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates. (ii) If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding. If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down carefully existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified & directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates. ( ii) If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding. If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates ii) If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
One 3pin/5pin 5/6 Amps socket out let on same board with other switches , with cables 1.5 sq mm size , complete all as specified and directed.
One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
All as per item No 154 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point.
S & F Switch Modular single pole, one way 6 Amps, 1 module 240 Volts AC complete all as specified & directed.
Supply and fixing switch modular , one-way 16Amps, 1 module 240 Volts AC complete all as specified & directed.
Supply and fixing modular socket, 6A -2/3 pin combined 2 module ISI marked 230 volts, 50 Hz complete all as specified & directed.
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts 50 hz complete all as specified & directed.
Supply and fixing ceiling rose surface bakelite 65x25mm dia having three terminals ISI marked complete all as specified & directed.
Supply and fixing step socket type modular fan regulator 120/280 V , 2 module complete all as specified & directed.
Supply and fixing bell push modular flush type single pole one way 6 Amps, 1 module complete all as specified & directed.
S&F Bell ding dong Type , 240 Volts complete all as specified and directed.
Supply and fixing batton/angle holder insulated body with back plate, suitable for batten fittings complete all as specified & directed.
Supply and fixing in replacement of LED luminaire 600mm X 600mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glair free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fixing in repair LED lights fitting 1X18 watt ,4 ft with extruded aluminium housing heat sink, environmental friendly energy efficient translucent diffuser with LED light source,2400 Lumens( minimum) coefficient colour temp 6000°K to 6500 °K, surge protection range ≥ 2.5KV, voltage protection range-120-300VAC,2 years warranty ,system efficacy not less than140Lm/Watt for the fitting, power factor >.95,total harmonic distortion< 20% color rendering index>80, fixed on site with all accessories including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed.
Supply and fixing in repair energy efficient LED lights fitting, 9 watt , 230 Volt, of 600 mm length,CCT 6000ºK to 6500° K , decorative ultra slim linear LED lighting fixture with extruded aluminium housing heat sink, environmental friendly, energy efficient LED light source more than1200 lumens , wall mounted mirror batten, integrated electronic driver, system efficacy not less than 140 lumens /watt CCT 6000 to 6500°K , surge protection range ≥ 2.5 KV , voltage protection range 120-300 volt AC, power factor > 0.95 total harmonic distortion < 20%, colour rendering index > 80, fixed on site with all accessories including 2 years warranty connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed.
Supply and fixing single pole and neutral enclosure with a two pole and earth plug socket complete with 01 No, RCCB 25 Amp, 30 mili amps, DP, 240 Volts, AC complete all as specified & directed. (Note - Cost of cutting chases for enclosure concealed in wall of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates.)
S & F PVC fresh air fan 240 volts Ac 50 Hz 250 mm sweep PVC body including louvers and cutting as required size and shape complete all as specified & directed.
S & F exhaust fan 240 volts Ac 50 Hz 300 mm sweep matellic body (RPM will not be more then 900) including louvers and cutting as required size and shape complete all as specified & directed.
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar complete all as specified & directed.
Supply and fixing MCB SP 5 to 32 Amp 'B' series 10 KA repturing capacity complete all as specified & directed.
Supply and fixing MCB SPN 40 Amp 240 V AC 10 KA repturing capacity complete all as specified & directed.
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed multi stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/ concealed in wall as per existing along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion all as specified and as directed. Note:- Two runs of multi stranded copper conductor cable and one run of earth wire including PVC conduit will be measured as a one length.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by 4 mm GI wire as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified & directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
ANKIT KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .