Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAccepted-AOC | L1 | Accepted-AOC Work Order Issued | |
| 2 | L2₹2.4 L+₹23,061 (10.7%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹2.5 L+₹34,578 (16.1%)Rejected-Finance 447 A DHALITITHA BASIRHAT NORTH 24 PARGANAS PIN 743412 WEST BENGAL | BASIRHAT | NORTH 24 PARGANAS | WEST BENGAL | 743412 | L3 | Rejected-Finance L3 |
Tender Value
₹2.7 L
EMD Value
₹5,381
Closing Date
9 Jun 2025, 1:00 pmClosed
Assistant Engineer
Baruipur Electrical Sub Division PWD
SITC of AC machine for Death birth counter room Medicine OPD room sister in charge room of Baruipur Sub Divisional Hospital Baruipur South 24 Parganas
2025_WBPWD_850000_1
WBPWD/AE/BESD/eNIQ02/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Baruipur Sub Divisional Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,381
24 Jun 2025
21 May 2025
11 Jun 2025
27 May 2025
9 Jun 2025
31 May 2025
Amount
PART-A- Electrical Installation work. Supply & Fixing 240V, 25A, 3 pin Modular type plug socket (Brand approved by EIC), with plug top, on 2 module GI Modular Switch Board complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
Supply & Fixing 240V, 25A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
S&F 415 V, Horizontal type, TPN MCB DB (4-way) with SS enclosure double-door with IP-42/43 protection, with cable-end box at both ends & Four Pole Isolators as incomer and SPMCBs ('C' Curve, 10 KA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Interconnection with suitable size of copper wire and neutral link & provision for earthing attachment as per GS. Incoming 63 A FP Isolator -1 No, Outgoing 6-32A SPMCB-12 no. (Make:Legrand) .
Supply and delivery of 1.1 kv grade 4 core 25 sq mm XLPE/PVC Ar Al cable, as per direction of EIC. [Make - Polycab/Havells/RR Kabel/Gloster] from VTPNDB to HTPNDB]
Laying of cable upto 3/4 core 25 sqmm (4 core 25 sq mm XLPE/PVC Ar Al cable) on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting as per GS [From VTPNDB to HTPNDB]
S/F compression type cable end gland with finishing end by crimping method for the following size for 4 core 16 sqmm A/Al armoured cable as per GS.
S/F Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket for 4 core 16sqmm XLPE-armoured AL. cable(Dowels make), tapes, anticorrosive paste & jointing materials :as per GS.
Distribution wiring in 1.1 KV grade 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [ AC] single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. A) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm)
PART B - SITC of AC Supply & Delivery of High-wall Split-type Air-Conditioner having following specification: Cooling Capacity - 5.2 kW (Minimum) Minimum ISEER - 3.8, BEE level - 3-Star(min)[1st July22 to 31st December 2025] IS Compliance - IS-1391(Part-I & Part-II) with all amendment Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 48ºC and above Air flow: 600 CFM(Minimum) Power supply -230V, 50Hz (±tolerance asper applicable standard),as directed by EIC. The scope of work is also includes supply and fixing of following (i) Necessary refrigeration copper line with nitrile rubber insulation and wrapping tape - 3 mtr (ii) Necessary 3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr and 230V, 25A, 3 pin plug top with indicator(Anchor/North West/Legrand/Havells) [Make: General/Mitsubishi Electric/ Daikin/ Blue Star/ Voltas/ Carrier]
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including Supply of required Refrigerant, S&F of necessary fixing arrangement for indoor and 40 x 40 x 5 mm MS angle iron frame for outdoor unit (or arrangement recomended by Manufacturer), duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of the EIC.
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. (i) Supply & Fixing of extra refrigerant pipe(as requisite dia) with nitrile rubber insulation and wrapping tape [each mtr Refrigerent pipe will include cost of 1 metre liquid pipe line and 1 mtr gas pipe line of required dia and other accesories as required].
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. i) 2.5 sqmm ,3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster)
Supply & Laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC (Make: Suprime/ Oriplast)
Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees.
AIR COOL ENTERPRISE (BID ID -6497702)
BENGAL TRADING CO (BID ID -6489749)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .