Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC | L1 | Accepted-AOC Being reasonable | |
| 2 | L2₹37.6 L+₹2.1 L (5.87%)Rejected-Finance H NO 786 ANAND VIHAR COLONY PILIBHIT BYPASS BAREILLY UP PIN 243005 | BAREILLY | UTTAR PRADESH | 243005 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹37.9 L+₹2.4 L (6.70%)Rejected-Finance 37 B MODEL TOWN NEAR HARI MANDIR BAREILLY UP 243001 | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-Finance Not being L1 |
Tender Value
₹34.5 L
EMD Value
₹69,000
Closing Date
9 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Shilpam Bharali
Garrison Engineer (AF) Military Engineer Services, Bareilly 243002 (UP)
8752 PROVN OF 3 PHASE POWER SUPPLY FOR PROJECT EAGLE AND SERVO STABILIZER FOR DCN EQUIPMENT AT 781 SU AND CERTAIN B.R AND E.M MINOR WORKS AT AF STATION, BAREILLY
2023_MES_611989_3
8752/E8
Open Tender
Civil Works
Item Rate
180 days
Bareilly
Class D
Category a(i) and b(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (AF) Bareilly
₹69,000
Yes
29 Nov 2023
16 Oct 2023
11 Nov 2023
16 Oct 2023
9 Nov 2023
23 Oct 2023
Amount
Surface excavation n.exc. 30cm deep and averaging 15cm deep and getting out in soft/ loose soil all as specified.
Excavating manually in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in soft/ loose soil.
Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point.
Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25cm in any type of soil.
M&L for plain cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete, sub base for flooring etc. all as specified and as directed.
M&L for brick work with fly ash bricks straight or curved on plan exc. 6m mean radius using old size bricks built in cement mortar (1:6) all as specified.
M&L for 40mm thick cement concrete PCC 1:2:4 type B1 using 20mm graded aggregate as in flooring finishing even and smooth without using extra cement all as specified.
M&L for rendering 15mm thick in CM (1:4) on brick or concrete surfaces, finishing even and smooth without using extra cement complete all as specified.
M&L for providing precast reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
S&F of 150 mm bore reinforced concrete pipe class NP-2 laid and jointed complete with collars in neat cement slurry complete all as specified and directed.
S&F of 200 mm bore reinforced concrete pipe class NP-2 laid and jointed complete with collars in neat cement slurry complete all as specified and directed.
M&L for concrete bed to drain pipes of 150mm bore dia including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6, type C2 all as specified.
M&L for concrete bed to drain pipes of 200mm bore dia including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6, type C2 all as specified.
M&L for plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) in surface channel and drains complete all as specified and as directed.
S&F high strength deformed TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and as directed.
S&F high strength deformed TMT steel bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and as directed.
Use and removal of steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surface of concrete all as specified
Use and removal of steel formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surface of concrete all as specified
M&L for Reinforced cement concrete 1:1½:3 type A1 (using 20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like concrete all as specified.
M&L for hardcore with broken stone or boulders of gauge n. exc. 63mm, deposited, spread and leveled in layers n. exc. 15cm thick, watered and rammed to a true surface.
M&L for 75mm thick cement concrete PCC 1:3:6 type C2 using 40mm graded aggregate as in flooring/ plinth protection finishing even and smooth without using extra cement all as specified.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash all as specified and as directed.
S&F Cast iron soil, waste and vent pipes 100mm bore, sand cast in any length with or without ears, with cement joints, fixed to walls all as specified.
S&F of 100mm bore cast iron bend (any radius), diminishing piece or taper (larger bore measured) complete all as specified and directed.
M&L for 1.6mm thick Mild steel, plain, black sheet in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required and as specified.
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe 410-W (Gde-E- 250), Quality-A all as specified.
M&L for preparation of new or previously untreated steel/ iron surfaces of any description exceeding 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed.
M&L for PCC 100mm thick type D2 (1:4:8) using 40mm graded aggregate as in sub-base for flooring/ hard standing complete all as specified.
M&L for PCC 100mm thick type B1 (1:2:4) using 20mm graded aggregate as in hard standing/ flooring complete finishing even and smooth without using extra cement all as specified.
M&L for Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'B' all as specified.
M&L for roughening surfaces of old concrete floor/ wall by picking, sweeping clean and washing down with water to remove dust, etc., brushing neat cement slurry with 3 kg of cement per sq.m all as specified.
M&L for 25mm thick cement concrete PCC 1:2:4 type B0 using 12.5mm graded aggregate as in sub base for flooring all as specified
M&L for double charged, vitrified tiles, coloured, first quality of size 600x600mm, 9 to 10mm thick as in Floors/ skirting, set and jointed in cement slurry, finished with flush pointing in coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:6 complete all as specified and as directed. [Note: The colour / shade / design of tiles shall be as approved by GE.]
M&L for glazed digitally printed ceramic tiles of size 300x450mm, 6 to 7mm thick in vertical surfaces of wall, set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 10mm thick backing coat in CM 1:4 complete all as specified.
M&L for non skid coloured ceramic joint free tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.18sq.m but n.exc. 0.36sq.m, in floors etc., set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 15mm thick screed bed in CM (1:6) complete all as specified.
M&L for pre-polished coloured chequered cement concrete tiles (rubber moulded with glossy finish) of size 300x300mm, 25mm thick, set, jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles laid over and including 20mm thick screed bed in CM 1:6 complete all as specified.
S&F GI tubes 80mm bore dia medium grade galvanized, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
M&L for on site LLDPE septic tank with up flow filter including media designed to carry sewage and sludge water, excavation & earth work in any type of soil, PCC (1:4:8) type D2 below foundation, vent shaft, connection, complete for 30 users complete all as specified and as directed.
M&L for construction of soakage well of size 3.6m internal dia, 3.0m effective depth all as per TD drg No. CE LZ TD/576, Sheet 1/2 & 2/2 dated 16.06.1989 with excavation and earthwork in any type of soil, foundation in PCC 1:3:6 type C2, Brick work in dwarf wall in CM 1:4, brick work in CM 1:4 for solid walls, honey comb brick work in CM 1:4, RCC type B1 for cover slab, PCC type B1 for band complete all as specified and as directed.
M&L for construction of soakage well of size 3.0m internal dia, 3.0m effective depth all as per TD drg No. CE LZ TD/576, Sheet 1/2 & 2/2 dated 16.06.1989 with excavation and earthwork in any type of soil, foundation in PCC 1:3:6 type C2, Brick work in dwarf wall in CM 1:4, brick work in CM 1:4 for solid walls, honey comb brick work in CM 1:4, RCC type B1 for cover slab, PCC type B1 for band complete all as specified and as directed.
M&L for cutting trench in road/ hard standing (Bituminous/ concrete) 30 cm wide, up to 600mm deep, for taking the sewer lines and refilling trenches with soil/ debris and top 200mm depth with PCC type B1 complete all as directed.
S&F 5.50 mm thick sheet glass (tinted/ reflective type) of any size complete fixed to aluminium frames
S&F 12mm thick prelaminated particle board, interior grade, prelaminated on both sides with decorative choice lamination, fixed with screws to timber frame work all as specified.
M&L for preparation of new plastered surfaces of walls & applying two coats of distemper oil emulsion over a coat of alkali resistant primer all as specified and as directed.
M&L for 18-20mm thick Granite work of colour Ruby red/ Telephone black/ Jade black (table rubbed and polished) in floors, steps, jambs, pillars, window cills, cooking platforms and like set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 20mm thick screed bed in CM 1:4 complete including rounding and polishing the edges all as specified and as directed.
S&F standard size EPDM rubber beading for fixing glass in to aluminium frames all as directed.
S&F Mortise lock, brass vertical type, size 65mm, 2 levers all as specified
S&F floor door stopper of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm.
S&F powder coated aluminium (minimum thickness of powder coating 50 microns) frames for doors, windows, ventilators and partitions (fixed portion) with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS:733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc. complete all as specified and as directed. [Note: Weight of builders hardware & rubber beading shall not be considered for payment, however rate quoted shall be deemed to be included for the same]
S&F powder coated aluminium (minimum thickness of powder coating 50 microns) door shutters, aluminium section weighing not less than 1.00 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodized aluminum snap beading screws etc. complete all as specified and as directed. [Note: Panel inserts like glass, prelaminated particle board & gauge shall be measured & paid separately]
S&F powder coated aluminium (minimum thickness of powder coating 50 microns) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as handles, SS friction hinges etc. complete all as specified and as directed. [Note: Panel inserts like glass & gauge shall be measured & paid separately]
Taking down chowkats or frames with shutters (with out taking off shutters from frames) exc. 1.5sq.m. but n. exc. 4sq.m. each all as specified.
S&F Anti Radiation Hermetic hinged lead lined door made of SS 304 grade stainless steel for civil opening 1000x2100mm, with 2mm lead sheet in 60mm thick door blade and wall frame, lever handle with emergency release, rising hinges and wall covering for wall width up to 400mm, conforming to AERB guidelines including making good the jambs of opening complete all as specified and as directed.
Taking down cement plaster on brick or stone walls including raking out joints, hacking for key, scrubbing down with water etc. to receive plaster
M&L for rendering 15mm thick in CM (1:6) on brick or concrete surfaces, finishing even and smooth without using extra cement complete all as specified.
M&L for preparation of new plastered surfaces of walls and applying white cement based putty for 1.5 to 2mm thick, sand papering to obtain smooth and even finish and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as directed.
S&F sheet steel powder coated distribution board Vertical type TPN 4 ways, 415 volts, with 200 Amps rated copper bus bar, neutral link, earth bar, IP 43 protection and double door, suitable for mounting MCCB up to 160 Amps as incomer and MCBs as out going complete all as specified and as directed. [Cat No. 5077 45 of make Legrand/ Cat No. DBVTH004DD of Make: L&T]
S&F sheet steel powder coated distribution board SPN 4 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, IP 43 protection and double door, IK-09 with metal door suitable for mounting MCBs all as specified and as directed.
S&F MCCB 4 pole, 125 Amps, 16 KA, 415 Volts with thermal magnetic release connecting up with necessary spreader links complete all as directed.
S&F MCB TPN, 415 volts, 100 Amps, C curve 10 KA all as specified and as directed.
S&F MCB SPN, 240 volts, 40 to 63 Amps, C curve 10 KA all as specified and as directed.
S&F MCB SP, 6 to 32 Amps, 230 V, C curve, 10 KA all as specified and as directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to 4mm dia GI earth continuity wire by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected from earth plate electrode to main switch board/ earthing test point including watering arrangement with PCC 1:3:6 type C1 chamber, MS funnel, wire gauge, 50mm thick precast RCC cover in Type B1, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc 50m, charcoal and salt complete all as shown in electrical plate No. 3 of Schedule Part-I 2009 and connected to earthing test point all as specified or indicated and testing on completion.
M&L for Point wiring complete as specified with 1100 volt grade 1.5sq.mm. (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade (IS:694) drawn through and including rigid non-metallic PVC conduit of suitable size not less than 20mm dia, with all fittings, concealed in wall/ roof / floor including pressed steel concealed terminal boxes of required size with top cover of 3 mm thick of plastic laminated sheet of required colour suitable for housing switches/ sockets/ regulators etc. duly earthed with same cable as for wiring above but green in colour as continuous earthing wire complete all as specified for one light/ fan/ bell point controlled by one switch 6 Amps 1 way. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
All as per Item No. 64 herein before but for one 3 pin 6 Amp socket out let point on independent board.
All as per item No. 64 herein before but point wiring with 1100 volt grade 2.5sq.mm. (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade (IS:694) duly earthed with same cable as for wiring above but green in colour as continuous earthing wire suitable for one 3 pin 16 Amps socket out let on independent board.
S&F wall/ surface mounted type LED light fitting 1 X 20 watt (4' long) with extruded aluminum batten with multiple lumen packages complete with all accessories internally pre-wired and including making electric connection with flexible three core 1.50 sq.mm size stranded copper conductor cable from light fitting to ceiling rose complete all as specified and directed. [Cat. Part No. BN021C LED22S PSU CW GR (SmartBright) of make: Philips or Cat No. ENDURALINEARNEOBS20WLED865SPCWH of make: Havells/ Cat No. CCS-100-20-65-HL2-DP-NWH of make: CG/ Cat No. LL20-221-XXX-65NE3 of make: Wipro]
S&F Ceiling fan complete with blades, white colour, with down rod, including all accessories, 230 V, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00, BEE 5 star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
S&F switch piano, flush type SP, one way 5/6 Amps, 230V AC
S&F switch piano, flush type, SP, one way, 15/ 16 Amps, 250 V, ISI marked.
S&F socket outlet 6 Amp, 2 in 1, 5 pin, 230V AC
S&F socket outlet 6/16 Amp, 2 in 1, 6 pin, 230 V AC
S&F ceiling rose PVC/ Poly carbonate isolated body, three terminal complete all as specified.
S&F electronic fan speed regulator, suitable for single phase AC 240 volts, 50 Hz, 100 watts complete all as specified and as directed by Engineer-in-Charge.
S&F Heavy duty Exhaust fan 380mm sweep, single phase 230V AC, 1400 RPM metal body with louvers including electric connection from ceiling rose to fan connector with PVC insulated 2 core copper cable of size 0.75 sq.mm complete all as directed.
M&L for cutting opening in to existing one brick thick walls for fixing the exhaust fan in the required shape and making good the surfaces with cement mortar and finishing the surfaces to match the existing surfaces complete all as directed.
M&L for earthing comprising of copper earth plate electrode 600 mm X 600 mm X 3 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to copper earth strip of size 20 X 3 mm by means of nut-bolts, check nuts and washers of copper all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust and common salt all around the earth plate in alternate layers minimum 150 mm (compacted thickness) in all directions with and including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover of size 450 mm X 450 mm in cement concrete 1:2:4, type B-1, duly reinforced with 8 mm dia mild steel TMT bars @ 100 mm both ways center to center with suitable lifting handle made of 10 mm dia mild steel round bar to lift the cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 40 mm bore including testing on completion of job complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE (i.e. LESS THAN ONE OHM) IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
S&F single pointed air termination aluminum rod, 12mm dia and 300mm long including 20mm size air terminal base/ ridge saddle made of gun metal with and including fixing arrangement on the ridge of RCC roof / on pole as required complete all as specified and directed.
S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex head screws for holding the bronze plate including fastening/ bolting the roof down conductor and earth electrode over the bronze plate with copper bolts & nuts of suitable size, providing 10mm thick fibre sheet of size 15x15cm below the test point to avoid direct contact with wall including enclosing the test point with 1.6mm thick MS sheet front openable box duly painted complete all as directed by Engineer -in-Charge.
S&F aluminium strip 20x3 mm size as in earth continuity conductor or main earthing lead buried in ground/ fixed to wall or any other indicated situation for loop earthing and the like up to test point fixed on necessary insulators and fastening screws, rawl plugs complete all as specified and directed. Note: The joints of each lead strip shall be welded/ brazed and the cost of brazing/ welding shall deem to be included in unit rate of this item.
S&F copper strip 20x3 mm size as in earth continuity conductor or main earthing lead buried in ground/ fixed to wall or any other indicated situation for loop earthing and the like up to test point fixed on necessary insulators and fastening screws, rawl plugs complete all as specified and directed. Note: The joints of each lead strip shall be welded/ brazed and the cost of brazing/ welding shall deem to be included in unit rate of this item.
S&F GI pipe of 40mm bore dia light grade for earth strip protection, laid in trenches, surfaces or fixed to wall with suitable clamps complete all as specified and as directed.
Supply, lay, connect, test and commissioning of LT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade of size 4 Core 25 Sq.mm complete all as specified and directed. Note: (i) Contractor shall bring the entire cable in one length. (ii) Necessary test results like continuity test, megger tests shall be submitted to Engineer-in-Charge before the cable is laid. (iii) Excavation & earth work will be measured and paid separately.
All as per Item No. 83 herein before but cable of size 3.5 core 50sq.mm
All as per Item No. 83 herein before but cable of size 3.5 core 95sq.mm
All as per Item No. 83 herein before but cable of size 2 core 16sq.mm
S&F On load changeover switch 4 pole, 415 Volts, 160 Amps capacity with sheet steel enclosure, operating handle complete fixed to wall including necessary cable connections all as directed.
S&F of sheet metal enclosure with socket plug top and MCB triple pole and neutral enclosure 63 Amps with a 3P+N+Earth plug and socket complete with one No. TPN MCB 25 Ampere capacity 240 Volts complete all as specified and directed.
Making horizontal bore hole under the road suitable for drawing up to 80mm bore pipe at a depth not less than 1 Mtr below ground level for passing of LT underground cable complete all as specified and as directed.
Supply and laying GI pipe of 50mm bore dia light grade for cable protection, laid in trenches/ drawn through boring for drawing cables complete all as specified and as directed.
All as per Item No. 90 herein before but of size 80mm bore dia
Supply and spread river sand as in cushioning for UG cable all as specified in clause 19.75 of SSR Part I. [Note: Punned down thickness shall be considered for payment]
M&L for well burnt Sub class 'B', modular bricks laid dry, flat, over the cable abutting each other, complete all as specified and directed.
Supply, installation and commissioning of water cooler with SS 304 grade stainless steel body and tank working on 240 Volts, 50 Hz AC supply complete with hermetically sealed reciprocating compressor with copper tube evaporator, fan motor, thermostatic temperature control, 02 Nos brass CP taps, PVC connections, PVC drain pipe etc., puff insulation, suitable to operate with CFC free refrigerant gas with storage capacity of 80 litres & nominal cooling capacity of 40 litres/ hour complete all as directed. [Make of Cooler: Voltas Model No. SDLX4080B or equivalent model in Blue Star/ Usha]
Supply and install Voltage Stabilizer Copper wound for automatic operation, single phase naturally air cooled indoor floor mounted type & designed for input variation between 130 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5 % and of capacity 2 KVA complete all as specified and as directed by Engineer-in-Charge.
S&F GI tubes 15mm bore dia medium grade galvanized, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S&F GI tubes 20mm bore dia medium grade galvanized, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S&F 15mm bore gun metal globe or gate valve with iron wheel heads Class-II, screwed both ends for iron pipe all as specified.
S&F MCCB 4 pole, 100 Amps, 25 KA, 415 Volts with thermal magnetic release connecting up with necessary spreader links complete with and including sheet steel enclosure all as directed.
S&F Off load changeover switch 4 pole, 415 Volts, 250 Amps capacity with sheet steel enclosure, operating handle complete fixed to wall including necessary cable connections all as directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized earth strip of 32X6mm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected from earth plate electrode to main switch board/ earthing test point including watering arrangement with PCC 1:3:6 type C1 chamber, MS funnel, wire gauge, 50mm thick precast RCC cover in Type B1, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc 50m, charcoal and salt complete all as shown in electrical plate No. 3 of SSR Part-I 2009 and connected to earthing test point all as specified or indicated and testing on completion
S&F GI strip 25x4 mm size as in earth continuity conductor or main earthing lead buried in ground/ fixed to wall or any other indicated situation for loop earthing and the like up to test point fixed on necessary insulators and fastening screws, rawl plugs complete all as specified and directed. Note: The joints of each lead strip shall be welded/ brazed and the cost of brazing/ welding shall deem to be included in unit rate of this item.
M&L for providing cement concrete type B1, 1:2:4 using 20mm graded aggregate as in lintels up to 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, copings, bed plates etc complete including necessary formwork all as specified.
Supply, installation, commissioning and testing of 75 KVA capacity servo controlled voltage stabilizer confirming to BIS-9815 (Part-1) (1994), three phase, 50 Hz, naturally oil cooled, indoor type, unbalanced type, copper wound, metallic body duly powder coated with lifting hooks two Nos., with digital display type, relay free (microprocessor based) smooth and silent operation with and including 1st filling of transformer oil up to required level comprising of the following specifications and characteristics complete all as specified and directed: - (a) Input voltage range- 300 to 480 Volts, 3 Phase, 50 Hz. (b) Output voltage stabilized at- 380 Volts + 10%, 3 Phase, 50 Hz. (c) Operating frequency- 47 to 53 Hz. (d) Operating Temperature- 0 to 50 degree centigrade. (e) No. of Phases- 03. (f) Speed of correction- 8 to 6 volts per Second for single phase and 13 volts per second Phase to Phase. (g) Efficiency- Greater than 97%. (h) Type of voltage / load- Unbalanced 4 wire (j) Mode of operation- Fully automatic. (k) Displaying type- Digital voltmeter, digital ammeter, digital input frequency meter. (l) Protective- Over voltage, under voltage, over load, High / low voltage cut off, single phase preventer and phase reversal protection with by pass arrangement switch 4 Pole of suitable capacity, spike suppressor, alarm system. (m) MCCB- INPUT, OUTPUT MCCBs of suitable capacity as per KVA rating. NOTE: - Design, drawings, Technical specifications shall be approved by the Garrison Engineer.
Supply, installation, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 1200mm width x 1000mm height (with canopy & base channel) x 450mm depth, M.S. channel base frame mounted conforming to IS/IEC-61439-1&2 with rated fault 65kA/1 Sec with internal arc containment, suitable for 3 phase 4 wire, 415 Volts AC supply and having 4 Nos Aluminium bus bars of rating 300 Amps, duly powder coated with seven (07) tanks pre-treatment process followed by powder coated painting (thickness not less than 80 micron) with RAL 7032 (Siemens Gray) shade. The Feeder Pillar shall be dust and vermin proof with degree of protection not less than IP-54 and Internal wiring with PVC insulated copper conductor multi-stranded cable 1100 volts grade IS-694 marked. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate with compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility. The feeder pillar shall be comprising of the following:
INCOMING: (i) MCCB 100 Amp, 4 pole, 25 KA, 415 Volts - 01 No (ii) Voltmeter 0-500 Volts, Square flush type, digital - 01 No. (iii) Amp meter 0-600 Amps, Square flush type, digital - 01 No. (iv) Indication lamp LED type - RYB-01 set (v) Alarm system for indication of commercial power failure OUTGOING: (i) MCCB 63 Amp, 4 pole, 36 KA, 415 Volts - 02 No
Deduct: Amount of Schedule of Credit b/f from Sl. Page No. 16 of tender document i.e. Rs. 150.00
ZAIGHAM ENTERPRISES
MOHINDER SINGH AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .