| Sl No | Description | Qty | Unit | SMA ENERGY & INFRA PRIVATE LIMITED L1 | VERSATILE L3 | Dev Bhoomi Enterprises L2 |
|---|---|---|---|---|---|---|
| 1.01 | Solar Monocrystalline PV module minimum 550/570 Wp for 50KW to ensure the output. | 1 | Job | 14,98,610 ₹14,98,610 | 14,99,120 ₹14,99,120 | 14,95,000 ₹14,95,000 Lowest |
| 1.02 | String invertor with power exporting facility to the grid having out put shall be 415 V AC, 50 H3, 3 Phase degree of protection IP-65 with self protective and self diagnositic features such as over voltage over current (both input and output) over/ under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage competable mean in each and every sense to synchronize with UPCL grid. | 1 | No | 3,09,110 ₹3,09,110 Lowest | 3,15,000 ₹3,15,000 | 3,30,000 ₹3,30,000 |
| 1.03 | Hot dipped Galvanised structure including SS nut bolts at campus of pump housecomplete with grouting by cement concrete etc. | 1 | Job | 3,98,270 ₹3,98,270 | 4,05,000 ₹4,05,000 | 3,72,150 ₹3,72,150 Lowest |
| 1.04 | DCDB box between solar panels and the invertor containing DC SPD and DC MCB with fuse set complete | 1 | Job | 88,700 ₹88,700 Lowest | 95,000 ₹95,000 | 88,900 ₹88,900 |
| 1.05 | ACDB box with protective devices for overload and short circuit in between invertpr and AC side | 1 | No | 1,44,100 ₹1,44,100 | 1,40,000 ₹1,40,000 Lowest | 1,46,000 ₹1,46,000 |
| 1.06 | Copper bonded Lightening arrestor & surge protection. | 2 | Job | 63,280 ₹1,26,560 Lowest | 64,200 ₹1,28,400 | 63,500 ₹1,27,000 |
| 1.07 | Fire extenguisher 5 Kg. | 1 | No. | 11,110 ₹11,110 Lowest | 11,920 ₹11,920 | 11,910 ₹11,910 |
| 1.08 | 03 Nos.Chemical earthing complete with 1 core 4 sqmm earth wire PVC pits etc as per IE rule | 1 | Job | 2,24,120 ₹2,24,120 | 2,23,000 ₹2,23,000 Lowest | 2,28,000 ₹2,28,000 |
| 1.09 | Cabling work by copper 4 core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor | 1 | Job | 3,72,600 ₹3,72,600 | 3,67,800 ₹3,67,800 Lowest | 3,74,500 ₹3,74,500 |
| 1.10 | Miscellenious work i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable , Fire safety system etc. | 1 | Job | 70,320 ₹70,320 Lowest | 72,000 ₹72,000 | 72,400 ₹72,400 |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
15 Jun 2026, 5:00 pmClosed
Superintending Engineer
Superintending Engineer, Mechanical Circle, UPJN, Haldwani
SITC OF GRID CONNECTED ROOFTOP ON GROUND OR SUITEBLE LOCATION IN 03 MLD STP KICHHA CONSTRUCTED UNDER NAMAMI GANGE PROGRAMME AT BOLCK RUDRAPUR, DISST U S NAGAR
2026_MDPEY_95653_1
185/ G-7 /08 DATED 15-05-2026
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
Haldwani
Please refer tender documents
3 documents required · 3 mandatory
₹3,540
Executive Engineer
₹84,000
Haldwani
18 Aug 2026
19 May 2026
17 Jun 2026
19 May 2026
15 Jun 2026
1 Jun 2026
29 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Solar Monocrystalline PV module minimum 550/570 Wp for 50KW to ensure the output. | 1 | Job | - | - |
| 1.02 | String invertor with power exporting facility to the grid having out put shall be 415 V AC, 50 H3, 3 Phase degree of protection IP-65 with self protective and self diagnositic features such as over voltage over current (both input and output) over/ under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage competable mean in each and every sense to synchronize with UPCL grid. | 1 | No | - | - |
| 1.03 | Hot dipped Galvanised structure including SS nut bolts at campus of pump housecomplete with grouting by cement concrete etc. | 1 | Job | - | - |
| 1.04 | DCDB box between solar panels and the invertor containing DC SPD and DC MCB with fuse set complete | 1 | Job | - | - |
| 1.05 | ACDB box with protective devices for overload and short circuit in between invertpr and AC side | 1 | No | - | - |
| 1.06 | Copper bonded Lightening arrestor & surge protection. | 2 | Job | - | - |
| 1.07 | Fire extenguisher 5 Kg. | 1 | No. | - | - |
| 1.08 | 03 Nos.Chemical earthing complete with 1 core 4 sqmm earth wire PVC pits etc as per IE rule | 1 | Job | - | - |
| 1.09 | Cabling work by copper 4 core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor | 1 | Job | - | - |
| 1.1 | Miscellenious work i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable , Fire safety system etc. | 1 | Job | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.20 MB
RE-TENDERKICHHA.pdf
Tender Documents • 2.90 MB
BOQ_113087.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .