Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹34.4 L+₹85,111 (2.53%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹35.5 L+₹1.9 L (5.72%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹36.9 L+₹3.3 L (9.95%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to required category not found in enlistment letter |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
10 Feb 2024, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
AC REPAIR AND MAINT OF WINDOW/SPLIT/PACKAGE TYPE AC, WATER COOLER, REFRIGERATOR, DEEP FREEZER, CENTRAL AC, COLD STORAGE ROOM AND CERTAIN MISC WORKS AT BARRACKPORE UNDER GE BARRACKPORE
2024_MES_637418_1
8880/E8
Open Tender
Civil Works
Item Rate
270 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹98,000
Yes
9 Mar 2024
13 Jan 2024
12 Feb 2024
13 Jan 2024
10 Feb 2024
27 Jan 2024
Amount
Servicing & repairs to walk - in - cooler comprises with out door/indoor unit (Refrigeration Unit of Cap 10000-20000 BTU) of make BLUE STAR/ CARRIER by replacing the unserviceable parts of the machine including charging of Refrigerant gas, leak testing, Brazing the suction / discharge tubes where required and cleaning of Condensing unit, strainer, checking/repairs to sensor unit, HP/LP cut off valve for proper functioning and replace where required/ordered including testing complete all as specified and directed. (Note: (i) Spare parts will be measured and paid separately as " Supply only" under relavent item. (ii) Labour charge for taking down and fixing of " Supply only " items are deemed to be included with quoted rate)
Supply only following parts of walk-in-cooler of make Blue Star/Carrier complete all as specified and directed:-
Electronic Temperature controller complete all as specified and directed. (Make:- Blue Star/Carrier as approved)
Evaporator fan motor 70Watt complete all as specified and directed. (Make:- Blue Star/ Carrier as approved)
Three phase compressor contactor complete all as specified and directed. (Make:- Kirloskar/Hitachi/Emerson/Toshiba/Danfoss/Blue Star as approved)
Hermetically sealed compressor of capacity 2.5 TR, 3 phase, 415V AC, 50Hz complete all as specified and directed. (Make : Kirloskar/Hitachi/Emerson/Toshiba/Danfoss/Blue Star as approved)
Hermetically sealed compressor of capacity 3 TR, three phase, 415V AC, 50Hz complete all as specified and directed. (Make :Kirloskar/Hitachi/Emerson/Toshiba/Danfoss/Blue Star as approved)
Blower motor with blade of walk-in cooler of any make and capacity (as per sample) complete all as specified and directed.
Evaporator Fan motor set complete all as specified and directed.
HP/LP cutoff complete all as specified and directed. (Note for item No. 2.01 to 2.08 :- Maerials of item No. 2.01 to 2.08 to be in corporated in item No. 1.00 here -in-before)
Taking out split type air conditioners indoor and out door units complete for repair and overhauling of capacity 1.5/2.0 TR of any make/type after disconnecting refrigerant pipes, drain pipe and electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda/cleaning chemical agents, checking and replacing the spares like relay assembly, relay contactor, capacitors, thermostat, fan motor with blades & blower fan motor with blades, unserviceable strainer air filters cum dryier etc after taking down of old materials as required and also including connecting of refrigerant pipe, drain pipe and also charging of refrigerant gas and fixing back in its original location after satisfying testing complete all as specified and directed. (Note :- (i) Spare parts will be measured and paid separately as "Supply only". (ii) Refrigerant gas will be measured and paid separately as "Supply only". (iii) Lobour charge for taking down and fixing of " Supply only" materials are deemed to be included with quoted rate.)
Supply only relay assembly suitable for split type air conditioner 1.5/2.0 TR capacity (as per sample) complete all as specified and directed. (Make: Indfos/Whirlpool/Danfoss as approved)
Supply only fan motor with blade suitable for out door unit split type air conditioner up to 2 TR capacity (as per sample) complete all as specified and directed. (Make: Indfos/Whirlpool/Danfoss as approved)
Suppy only relay contactor No. 1622 suitable for split type air conditioners upto 2 ton capacity complete all as specified and directed. (Make: LG/ Samsung/Carrier/Blue Star/ Hitachi/Voltas/ Kirloskar as approved)
Supply only blower fan motor with blade for out door unit including capacitor, single phase, 230V, 50Hz, ISI Marked for split type air conditioner upto 2 TR capacity (as per sample) complete all as specified and directed. (Make: Usha/Siemens/Keltron as approved)
Supply only for starting capacitor of 80 to 100 MFD for split type air conditioners upto 2 TR capacity complete all as specified and directed. (Make: EPCOS/Keltron/Asian/Tibcon/ Universal as approved)
Supply only for running capacitor of 36 to 60 MFD for split type air conditioners complete all as specified and directed. (Make: EPCOS/Keltron/Asian/Tibcon/ Universal as approved) (Note for item No : 4 to 9:- Material of item No. 4 to 9 to be incorporated in item No. 3.00 here-in-before)
S&F for any type hermetically sealed compressor of split type air conditioner of 1.5 TR capacity including initial filling of refrigerant gas to the required pressure and testing after taking down and removing of old unserviceable compressor complete all as specified and directed. (Make : Voltas/ Hitachi/Blue Star/Carrier/ Emerson/Tecumseh as approved)
S&F for any type hermetically sealed compressor of split type air conditioner of 2.0 TR capacity including initial filling of refrigerant gas to the required pressure and testing after taking down and removing of old unserviceable compressor complete all as specified and directed. (Make : Voltas/ Hitachi/Blue Star/Carrier/ Emerson/Tecumseh as approved)
S&F for mild steel wall bracket (as per sample) suitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and making good disturbed surfaces to match with the existing after taking down old unserviceable bracket complete all as specified and directed.
Leak testing the complete gas circulating system with dry nitrogen after evacuating and rectifying/arresting leakage by cutting, soldering, flaring work with nut, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in split type air conditioner upto 1.5TR/ 2 TR capacity and testing complete all as specified and directed. (Note: Refrigerant gas will be measured and paid separately as "Supply only".)
Supply and topping up of refrigerant gas (R-134a/R-410a/R-407 or superior ) suitable for Refrigerators/water coolers/Deep freezers and cold room Air conditioners complete all as specified and directed. (Make: Mafron/Refron/FLORON as approved )
Supply and topping up of refrigerant gas (R-32 ) suitable for split/window AC complete all as specified and directed. (Make: Mafron/Refron/FLORON as approved )
Supply and topping up of refrigerant gas (R-22 ) suitable for split/window AC complete all as specified and directed. (Make: Mafron/Refron/FLORON as approved )
Supply & fixing in repairs of universal strainer air filters cum drier suitable for upto 2 TR capacity Split Air conditioners of any make (as per sample) complete all as specified and directed.
Repair to remote control unit (PCB board) after taking down from indoor unit of split type AC of 1.5/2.0 TR capacity and checking the electronic circuit and rectifying the defects by replacing the defective components with new ones and testing complete all as specified and directed.
Repair to remote control unit (PCB board) after taking down from indoor/outdoor unit of split type dual inverter AC of 1.5/2.0 TR capacity and checking the electronic circuit and rectifying the defects by replacing the defective components with new ones and testing complete all as specified and directed.
Repair to remote control unit (PCB board) after taking down from indoor/outdoor unit of split type dual inverter AC of 1.5/2.0 TR capacity replace and refix it with new one and testing complete all as specified and directed. (Make:- LG/Daikin/Haire etc as approved)
S&F of swing motor of 1.5/2.0 TR capacity split type AC (as per sample) after taking down of old unserviceable one from AC complete all as specified and directed.
S&F of acoustic ('U' foam) padding with all packing material for refrigerant tubing from outdoor unit to indoor unit after taking down of old unserviceable from AC complete all as specified and directed.
S&F in repairs of 15 mm dia PVC pipe, including bends, tees, elbows, sockets, saddles, etc for condensed water outlet complete all as specified and directed.
S&F in repairs of 0.064" to 0.080" (inch) dia and 28" to 35" long capillary tube with strainer for the split type AC 1.5/2 TR capacity complete all as specified and directed.
S&F in repairs of copper tube of size 10mm (3/8 inch) dia including necessary soldering, flaring work and jointing testing in between indoor to outdoor units of split type AC complete all as specified and directed. (Make:- Malasia/Camipro/Diamond/Star as approved)
All as per item No 25.00 here-in-before but size of copper tube 12mm (1/2 inch) dia complete all as specified and directed.
All as per item No 25.00 here-in-before but size of copper tube 6mm (1/4 inch) dia complete all as specified and directed.
All as per item No. 25.00 here-in-before but size of copper tube 15mm (5/8 inch) dia complete all as specified and directed.
S&F for PVC insulated, sheathed, multistranded, 1100V grade copper conductor cable of size 4 sqmm, 3 core after taking down existing unserviceable copper cable complete all as specified and directed. (Make:- Havells/R R KABEL/FINOLEX/KEI/POLYCAB)
S&F for PVC insulated, sheathed, multistranded, 1100V grade copper conductor cable of size 2.5 sqmm, 1 core after taking down existing unserviceable copper cable complete all as specified and directed. (Make:- Havells/R R KABEL/FINOLEX/KEI/POLYCAB)
Supply only hand remote control for split type AC of capacity 1.5/2 TR with 2 Nos batteries, 1.5 Volt of size 'AAA' (suitable for existing make) and testing complete all as specified and directed.
Dismantling of the split type / window type air conditioner of capacity 1.5/2.0 TR complete set from the existing position and shifting the same to the new location as per direction, complete indoor and outdoor units, refrigerant tubing, MS stand, stabilizer and cable etc and testing complete all as specified and directed.
S&F in repairs of 3 pin industrial plug top, ISI marked, suitable for industrial metal clad socket, single phase, 240 volts, 20 Amps including connection complete as all as specified and directed. (Make:Legrand/L&T/Siemens as approved)
S&F in repairs for copper condenser coil assembly with all accessories for split type AC upto 2 TR capacity suitable to existing make/type (as per sample) and testing complete as all as specified and directed. (Make :-Zeco/Citizen/Hitech/Loyid as approved)
Takind down old unserviceable cooling coil assembly from split type air conditioner upto 2 TR capacity supply and fixing condenser cooling coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.
Taking down old unserviceable 2-3 way refrigerant control valve from split air conditioner outdoor unit after evacuating of refrigrant gas and supply and fixing 2-3 way valve suitable for split type ACs of capacity upto 2TR and testing complete all as specified and directed.
Taking down old unserviseable split type air conditioner indoor unit and deposited in store yard for safe custody and Supply and fixing indoor unit of the split type air conditioner 1.5 TR capacity with all accessories such as installation plate with screws, blower motor, swing motor, filters etc duly pre-wired including connecting to existing refrigerant piping, electrical connections, drain pipe and testing etc complete all as specified and directed. (Make: Carrier/LG/Hitachi/Blue star/ Voltas as approved)
Taking down old unserviseable split type air conditioner outdoor unit and deposited in store yard for safe custody and Supply and fixing outdoor unit of the split type air conditioner 1.5 TR capacity and complete with all accessories such as hermetically sealed compressor and condenser unit, capacitors, relays, fan motor, duly prewired including connecting to existing refrigerant gas piping, electrical connections and testing etc complete as in repair all as specified and directed. (Make: Carrier/LG/Hitachi/Blue star/Voltas as approved)
Supply & fixing in repairs of capacitor 2.5 MFD complete all as specified and directed. (Make: Asian/Keltron/Epcos/Universal/Tibcon as approved)
Supply & fixing in repairs of capacitor 4 MFD complete all as specified and directed. (Make: Asian/Keltron/Epcos/Universal/Tibcon as approved)
Supply & fixing in repairs of capacitor 6 MFD complete all as specified and directed. (Make: Asian/Keltron/Epcos/Universal/Tipcon as approved)
Taking out window type air conditioner for servicing and overhauling of capacity 1.5/2.0 TR of any make/type after disconnecting of electric connection, removing dust by using blower and cleaning the condenser coil and components by using water and caustic soda and replacing the spares like relay, Capacitors , thermostat, fan motor, blades & blower and also including carrying out servicing , overhauling and charging of refrigerant gas and testing including fixing back in its original location complete all as specified and directed. (Note :- (i) Spares will be measured and paid separately as "Supply only" under relevent item. (ii) Labour charge for taking down & fixing of "Supply only" materials are deemed to be included with quoted rate)
Supply only of starting capacitor 80 to 100, 100 to 120 MFD for window type air conditioner complete all as specified and directed. (Make : Concap/Keltron/Asian/Tesla/Sarda/Siemens/Tibcon as approved)
Supply only of running capacitor 40/50/60 MFD for window type air conditioner complete all as specified and directed. (Make : Concap/Keltron/Asian/Tesla/Sarda/Siemens/Tibcon as approved)
Supply only thermostat switch suitable for 1.5/2.0 TR window type AC complete all as specified and directed. (Make : Honey Well/Indfors/Renutrol/Siemens/Daspars as approved)
Supply only of blower fan motor with blade including capacitor, single phase 230V, 50 Hz for window type air conditioner upto 2 TR capacity complete all as sepcified and directed. (Make: Usha/AUE/Siemens/Keltron or equivalent any make with ISI marked )
Supply only of fan motor with blade suitable for window type air conditioners upto 2 TR capacity complete all as specified and directed. (Make: As per sample)
Supply only of relay contactor suitable for existing window type air conditioners upto 1.5/2 TR capacity complete all as specified and directed. (Make: LG/Samsung/Carrier/Blue Star/Hitachi as approved)
Supply only of relay assembly No. 1622 suitable for window type air conditioners upto 1.5/2 TR capacity complete all as specified and directed. (Make: As per sample)
Supply only contactor, AC, 230 volts ,50Hz, suitable for Window ACs upto 2.00 TR capacity complete all as specified and directed. (Make: As per sample) (Note for item No.43.00 to 51.00 :- Materials of item No.43.00 to 51.00 to be incorporated in item No.42 here-in-before)
Replacing the corroted outer casing with base tray sheet of the window type air conditioner of capacity upto 2 TR of any type/make and supply and fix outer casing with base sheet made out of GI sheet suitable to window type air conditioner of capacity upto 2TR complete all as specified and directed.
Leak testing the complete gas circulating system with dry nitrogen after evacuating and rectifying/arresting leakage by cutting, soldering, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in window type air conditioner upto 2TR capacity and testing complete all as specified and directed.
S&F in repairs of over load protector suitable for window type air conditioner complete all as specified and directed. (Make: Usha/Sriram/Sarda as approved)
S&F of window type air conditioner electric driven (Single phase), cooling capacity 4500K cal per hour(1.5 Ton) BEE 5 star rated after taking down and depositing old unserviceable one to MES store yard complete all as specified and directed.
S&F of any type hermetically sealed compressor of window type of air conditioner of 1.5 TR capacity including initial filling of refrigerant gas to the required pressure and testing including taking down old unserviceable compressor complete all as specified and directed. (Make:Hitachi/Tecumseh/Carrier/Blue star/Emerson as approved)
S&F of any type hermetically sealed compressor of window type of air conditioner of 2.0 TR capacity including initial filling of refrigerant gas to the required pressure and testing including taking down old unserviceable compressor complete all as specified and directed. (Make:Hitachi/Tecumseh/Carrier/Blue star/Emerson as approved)
Taking down remote control with 2 Nos Batteries(1.5 Volts of size 'AAA') PCB board from window type AC of 1.5/2.0 TR capacity and checking the electronic circuit and rectifying the defects by replacing the defective components with new ones and testing complete all as specified and directed.
Taking out old unserviceable front side grill cover and supply and fix plastic or acrylic front side grill cover for window type AC upto 2.0 TR capacity of various makes etc complete all as specified and directed.
Taking down old unserviceable condenser coil assembly from window type air conditioner upto 2.0 TR capacity & supply and fix copper condenser coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.
Removing old unserviceable condenser cooling coil assembly from Window type air conditioner of 1.5 TR capacity & supply and fix condenser cooling coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.
M&L for spray painting to window type air conditioner of any type/make with two coats of synthetic enamel paint over a coat of red oxide primer after removal of existing treatment and preparation of surfaces and including removing dents complete all as specified and directed. (Make of Paint & Primer :- Asian/Burjer/Johnson & Nekaltron/Narolac)
Taking out water cooler for servicing and overhauling 40/80 ltrs, 40/120 ltrs, 40/160 ltrs capacity of any make/type after disconnecting of electric connection, removing dust by using blower and cleaning all the components by using water and caustic soda, checking and replacing the spares like relay, capacitors, thermostat, PVC pipes, push cock/lift cock, float valves etc and also including carrying out servicing, overhauling and charging of refrigerant gas and testing and fixing back in its original location complete all as specified and directed. (Note:- (i) Sparen will be measured & paid seperately as " Supply only" under relevent item. (ii) Labour charge for taking down & fixing of "Supply only" materials are deemed to be included with quoted rate.)
Supply only capacitor of 10-20 MFD complete all as specified and directed. (Make:Epcos/Keltron/Tibcon/Universal as approved)
Supply only PVC out let drain connecting pipe of 15 mm bore with brass nuts and washers of length not exceeding 60 cm for connecting of water coolers complete all as specified and directed. (Make : As per sample)
Supply only relay assembly suitable for water coolers of capacity complete all as specified and directed.
Supply only thermostat switch for water coolers any type/make complete all as specified and directed. (Note for item No. 64.00 to 67.00 :- Materials of item No. 64.00 to 67.00 to be incorporated in item No. 63.00 here-in-before)
Replacing the corroded portion of the water cooler & servicing capacity 40/80 ltrs, 40/120 ltrs, 40/160 ltrs capacity of any type/ make and providing the same gauge sheet in corroded portion by bending/welding, soldering and painting the replaced portion to match with existing colour and providing base support legs complete all as specified and directed.
S&F for hermetically sealed compressor for water cooler 40/80 Litres capacity including initial filling of refrigerant gas to the required pressure and testing complete including taking down old unserviceable compressor complete all as specified and directed. (Make: Voltas/Blue Star/Tecumseh/Emerson /Usha as approved)
S&F for hermetically sealed compressor for water cooler 60/120 Litres capacity including initial filling of refrigerant gas to the required pressure and testing complete including taking down old unserviceable compressor complete all as specified and directed. (Make: Voltas/Blue Star/Tecumseh/Emerson/Usha as approved)
Leak testing complete by gas circulating system with dry nitrogen after evacuate and rectifying/arresting leakage by cutting, soldering, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in water cooler 40/80 ltrs, 40/120 ltrs and 80/160 ltrs cooling capacity and testing complete all as specified and directed.
S&F of blower fan motor for water cooler upto 160 Ltrs capacity and testing including taking down old unserviceable motor complete all as specified and directed. (Make : As per sample)
S&F for in repairs push cock/lifting cock of brass chromium plated 15 mm bore self closing type with back plate for water cooler of any capacity complete all as specified and directed.
S&F for in repairs float valve assembly 15 mm dia with PVC body, polythene float suitable for water coolar complete all as specified and directed.
Taking down old unserviceable copper condenser coil assembly from water cooler any type 20/40 to 100/150Ltrs capacity and supply and fix copper condenser coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.
S&F in repair of fan motor with blade including capacitor, single phase, 230V, 50Hz for water coolers of capacity 40/80 Ltr & 60/120 Ltr complete all as specified and directed. (Make: Usha/ AUE/Siemens/Keltron or equivalent as approved)
S&F in repair of 15mm dia pillar taps, cast copper allay with capstan head, chromium plated, screwd down high pressure with or without lettered hot or cold wiht long screwed shaks and fly nuts screwed for iron pipes as complete all as specified and directed (Make:- Essco/Marc/Prayag/Hindware as approved)
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 ltrs including taking down old unserviceable one to MES store yard complete all as specified and directed.
M&L for spray painting to water coolers 40/80ltrs, 40/120ltrs, 40/160 ltrs of any type/make with two coats of synthetic enamel paint over one coat of red oxide primer after removal of existing treatment and preparation of surfaces and including removing dents complete all as specified and directed.
Taking out Refrigerator for servicing and overhauling from 165 litre to 352 ltr capacity (single door/Double door type) of any make/type after disconnecting of electric connection and cleaning all the components, checking and replacing the spares like relay,capacitors, thermostat, Fused bulb and also including carrying out servicing, oiling, greasing, charging of refrigerant gas and testing complete all as specified and directed. (Note :- (i) Spares will be measured and paid separately as "Supply only" under relevent item. (ii) Refrigerant gas will be measured and paid separately as "Supply only".)
Supply only for relay assembly suitable for refrigerators of any type of capacity 165 to 352 litres complete all as specified and directed.
Leak testing complete by gas circulating system with dry nitrogen, evacuate and rectifying/arresting leakage by cutting, soldering, jointing of refrigerant tubing and charging of refrigerant gas to required pressure in Refrigerator upto 352 ltr capacity and testing complete all as specified and directed.
S&F of refrigerators, electric driven (single phase), capacity more than 310 Litres upto 360 Litres BEE 5 star rated including taking down old unserviceable one and removing to MES store yard complete all as specified and directed.
S&F for hermetically sealed compressor of Refrigerator upto 185 litres capacity including initial filling of refrigerant gas to the required pressure and testing including taking down old unserviceable compressor complete all as specified and directed. (Make: Voltas/Kelvinator/Kirloskar/Tecumseh/Usha/Godrej as approved)
S&F of any type hermetically sealed compressor of Refrigerator of 210 to 352 litres capacity including initial filling of refrigerant gas to the required pressure and testing including taking down old unserviceable compressor complete all as specified and directed. (Make: LG/Voltas/Kelvinator/Tecumseh/Kirloskar/Usha/Godrej/Videocon/Samsung as approved)
S&F in repair of bi-metal switch for refrigerators of any type/ capacity 165 to 352 litres complete all as specified and directed. (Make:- LG/samsung/Videocon/Godrej/Whirlpool as approved)
S&F in repairs of condenser coil suitable for refrigerators of any type of capacity 165 to 352 litres complete all as specified and directed.
S&F in repairs of cooling coil suitable for refrigerators of any type/ capacity 165 to 352 litres complete all as specified and directed.
S&F in repairs of fan motor with blade suitable for refrigerators of any type of capacity 165 to 352 litrescomplete all as specified and directed.
S&F in repairs of MS refrigerator stand suitable for refrigerator of any type and any capacity complete all as specified and directed.
S&F in repairs of capacitor of 6 to 10 MFD complete all as specified and directed. (Make:Asian/Epcos/Tibcon/Keltron as approved)
S&F in repairs of thermostat switch for refrigerators of any capacity/ any make complete all as specified and directed.
S&F in repairs of heating element 20 to 40 watt for refrigerators of any capacity/ any make complete all as specified and directed. (Make: Indofoss/Ranutral/Annapurna as approved)
Taking down old unserviceable capilary copper tube of dia 0.031" (Inch) and supply and fix new capilary copper tube suitable for existing type/make/size complete all as specified and directed.
S&F in repairs of acrylic plastic chillar tray's suitable for vegitable ice tray's for refrigerators of any capacity complete all as specified and directed. (Make : As per sample)
Taking down old unserviceable bulb from refrigerator of any watt/capacity and supply and fix bulb as per existing type/capacity complete all as specified and directed. (Make : As per sample)
S&F in repairs of fan motor with blade, single phase, 230V AC 50 Hz for deep freeze of any make of capacity 200 to 400 Ltr complete all as specified and as directed. (Make : As per Sample)
S&F of anti-bacterial gasket set for refrigerators door of any capacity/ any type/ make (as per sample) complete all as specified and directed.
Taking out Deep freezers for repairs/ servicing to Deep freezer of capacity 150 to 400 ltr of any make/type by replacing unserviceable compressor and other parts from the machine as directed including charging of Refrigerant gas after vacuuming and making system leak proof. Brazing the suction / discharge tubes where required and cleaning of Condensing unit to achieve proper cooling effect. Checking of electronic circuit of machine and repair where necessary by replacing electronic parts and changing of wirings with proper size PVC insulated wires as directed and testing complete. (Note :- Compresssor shall be measured and paid seperately under relevent item)
Supply and fixing of capacitor of any capacity for Deep freezer of capacity 150 to 400 Ltr complete all as specified and directed by Enginner-in- Charge.
Supply only thermostate switch suitable for Deep freezer of capacity 150 to 400 litre (Make: Indfoss/ Denfoss/Ranutal/Annapurna as approved)
Supply only relay assembly suitable for Deep freeze complete all as specified and directed. (Make:- As per sample.)
Supply only fan motor with blade, single phase, 230V AC 50 Hz for deep freeze of any make of capacity 200 to 400 Ltr (Make : As per Sample) (Note for item No. 101.00 to 103.00 :- Materials of item No. 101.00 to 103.00 to be incorporated in item No. 100.00 here-in-before)
S&F for any type hermetically sealed compressor for deep freezer 150 to 400 litre capacity including initial filling of refrigerant gas to the required pressure and testing also including taking down old unserviceable compressor complete all as specified and directed . (Make: Voltas/Blue Star/Kirloskar/Tecumseh/Usha as approved)
Leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting, soldering, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in Deep freezer upto 400 Ltrs capacity and testing complete all as specified and directed.
Supply, Installation, commissioning and testing of voltage stabilizer for automatic operation single phase, wall mounted, copper wounded air cooled, with digital display desinged for input variation between 170 volt to 260 volt with output voltage 220 + 9% volt with calibration accuracy + 3% with high low cutoff, inteligent time delay facility of capacity 5.0KVA including taking down old unserviceable one complete all as specified and directed. (Make:- AE/APLAB/ ANREWYULE/ INDIAN TRANSFORMER & ELECTRICALS P. LTD./ V-GUARD/ VOLINA/ VINITEC)
S&F flat sleek smooth 25A motor starter for AC including cutting fixing of concealed MS 2M box with cover and finishing as complete all as specified and directed.
S&F in repairs of concealed socket 3 pin 25A for AC including cutting fixing MS 2M box with cover plate including all other necessary items complete all as specified and directed.
S&F of powder coated sheet metal enclosure acrylic door 415 volts AC,SPN distribution board 2 way suitable for flush mounting with 200 Amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200 Amps, MCB SPN/SP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed.
S & F in repairs of MCB SP, 6 to 32 Amps, B Curve 240 volts, 50 Hz, including making necessary incoming and out going electric connection with suitable size of copper lugs and testing complete all as specified and as directed by Engr-in-Charge.
S & F in repairs of MCB DP 40 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs and testing complete all as specified and as directed by Engr-in-Charge.
Attending waterleak complain of Air conditioning/other cooling appliances unit and solve the problem after dismantling and checking sloping if required re-locate indoor unit for getting slope to drain pipe, cleaning the cabinet, PVC drain pipe etc applying tape in joint and laying/sloping the drain pipe properly and fix the problem complete all as specified and directed. (Note:- If drain pipe required it will be measured and paid separately)
Attending cooling appliances complain and solve the problem it will be consider where there is no requirement of any material rate is only for taking job card from department and fix the prob at ground and deposite the job card duly signed by user to department.
S&F in repairs of new stainer in place of choked old one for any type of cooling appliances complete all as specified and directed.
M&L for water, dust and direct heat proof cover of split AC outdoor unit of any description as per direction of E-in-C.
FALCONS INDIA
SHARMA CONSTRUCTION
PIONEER TRADING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .