Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC 1ST FLOOR KRISHNA TOWERS OPP TO THRIKKAKARA TEMPLE THRIKKAKARA P O COCHIN 682 021 | ERNAKULAM | KERALA | 682021 | ₹1.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.3 Cr+₹6.3 L (5.04%)Rejected-AOC 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹1.3 Cr+₹6.3 L (5.04%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Upto date valid registration copy of KMC not submitted, Work completion certificate submitted not covering full scope of work as per installation details as mentioned in NIT. |
Tender Value
Refer Docs
EMD Value
₹2.7 L
Closing Date
16 Mar 2020, 6:00 pmClosed
DGM (E-E)
Airports Authority of India, M.B.B. Airport, Agartala
ARMO of E and M Installations at MBB Airport, Agartala (2019-20). SH Job Contract for Terminal Building, ATS Building, Residential Colony, New CISF Barrack and STP for 02 years
2020_AAI_44875_1
AAI/AGT/DGM(E-E)/NIT-04/19-20
Open Tender
Electrical Works
Item Rate
730 days
M.B.B. Airport, Agartala
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,180
Airports Authority of India
₹2.7 L
27 Apr 2020
3 Mar 2020
23 Mar 2020
4 Mar 2020
16 Mar 2020
4 Mar 2020
4 Mar 2020 - 10 Mar 2020
Amount
Operation and maintenance of all Internal and External electrical installations related to Terminal Building, ATS Building, Residential colony, New CISF Barrack and STP by attending complaints / faults/breakdown including rectification & ensuring serviceability/ satisfactory working condition of the systems on all the days i/c Sundays, Saturdays & holidays in shifts/general duties. The following manpower including reliever has to be deployed by the contractor:- (a) Highly Skilled (Supervisor) - 1 No. (b) Highly Skilled (Computer Operator) - 1No. (c) Skilled - 12 Nos. (d) Semi-Skilled - 5 No. (e) Un-skilled - 11 Nos. Note: The weekly off for all worker is mandatory.
Painting of street light pole of height above 6 metre and upto 10 metre above ground level including bracket etc. with two coats of synthetic aluminium paint/emulsion (above one mtr from the ground, excluding light fitting) after scrapping, cleaning, putty filling and applying one coat of red oxide primer coat including numbering, AAI approved logo and two coats of black bituminous paint upto one metre from the ground etc. complete as required and as directed by Engineer-in-charge.
Spray Painting of Feeder pillar / LT panel with 2 coat of smoke grey synthetic enamel paint after scrapping, cleaning, putty filling and applying one coat of red oxide primer coat including numbering and two coats of black bituminous paint on the legs/supports of LT panels from the ground etc. complete as required and as directed by Engineer-in-charge.
Rewinding of ceiling fan of 1200 mm sweep ceiling fan using 34 SWG enamalled copper winding wire including varnishing providing & fixing required insulation materials, testing & fixing etc as required.
Rewinding of ceiling fan of 1400 mm ceiling fan using 33 to 37 SWG enamalled copper winding wire including varnishing providing & fixing required insulation materials, testing & fixing etc as required.
Rewinding of 300 mm size exhaust fan using 32 SWG enamalled copper winding wire including varnishing providing & fixing required insulation materials, testing & fixing etc as required.
Complete dismantling / lifting of following capacity submersible pump motors set from existing deep tube well i/c discharge head/bend, column pipes etc. complete as required and as directed by Engineer-in-charge. 10 HP to 20 HP
Complete installation / lowering i.c commissioning of the following capacity submersible pump motor set with all accessories i/c discharge head/bend, cleaning & painting of column pipes, valves etc. complete as required and as directed by Engineer-in-charge. 10 HP to 20 HP
Dismantling and complete overhauling of the following capacity of sewage submersible pump motor set i/c descaling, cleaning, greasing of bearings, painting after re-assembling i/c testing, commissioning etc. complete as required and as directed by Engineer-in-charge. 10 HP to 20 HP
Extra duty performed by workers during extension of watch hour or any other requirements.
(a) Skilled
(b) Semi Skilled
(c) Un Skilled
Executing any items of CPWD-DSR-2016 as per direction of Engineer-in-charge (01 job work costing Rs.500000/-). Note: Please refer Clause 35 at page GTT-7 while quoting the rate for this item.
Voltas Limited
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .