Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹34.0 L+₹40,772.30 (1.21%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹38.3 L+₹4.6 L (13.8%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹38.7 L+₹5.1 L (15.1%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹39.2 L+₹5.6 L (16.6%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹32.8 L
EMD Value
₹65,600
Closing Date
9 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
SPL REPAIR TO BLDG NO. NP-59 AND PROVN OF MT STORE AT KANCHARPARA UNDER GE BARRACKPORE
2021_MES_481023_1
8570/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹65,600
Yes
11 Dec 2021
11 Oct 2021
10 Nov 2021
11 Oct 2021
9 Nov 2021
27 Oct 2021
60 days
Amount
Hacking out old broken glass (any thickness size quality or description) from wooden or steel/metal frame, glazed with putty or fixed with beads etc complete all as specified and directed.
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description etc complete all as specified and directed.
Dismantling timber scantlings (framed work) 40 sq.cm and over in section, in any position complete all as specified and directed.
Taking down chowkats or frame (without taking off shutter from the frames) exceeding 1.50 Sqm and not exceeding 4.00 Sqm each complete all as specified and directed.
Taking down chowkats or frame (without taking off shutter from the frames) not exceeding 1.50 Sqm each complete all as specified and directed.
Surface dressing in soft /loose soil not exceeding 15 cm deep complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation or for shafts, well, cesspits, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth, laying under ground cable, foundation and erection of poles and stays and getting out in soft/loose soil complete all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm, soil complete all as specified and directed.
Spreading, levelling and ramming including watering in floors etc layers not exceeding 25 cm thick (material obtained from excavated materials) complete all as specified and directed.
M&L for broken brick hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in surface channel and drains etc complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping, bed plates, fixing hold fast including necessary form work complete all as specified and directed.
M&L for RCC M-25 (design mix) (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed.
M&L for RCC M-25 (design mix) (using 20mm graded stone aggregate) as in foundations including rafts, footings, foundations beam, plinth beams, bases for columns etc , basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed.
M&L for RCC M-25 (design mix) (using 20mm graded stone aggregate) as in chajja etc complete all as specified and directed.
M&L for RCC M-25 (design mix) (using 20mm graded stone aggregate) as in column, pillar, piers, post and struts etc complete all as specified and directed.
M&L for RCC M-25 (design mix) (using 20mm graded aggregate) used as in slab supported on walls, beams and columns in floors roofs, landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for cutting chases, in brick wall and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing etc and making good the disturbed surface, cutting not exceeding 10cm girth complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
Add or deduct for each 25 mm girth or part there of over or under 30 cm complete all as specified and directed.
M&L for form work to sides of concrete foundation, footing, base of column, raft & plinth beam for flat, rough finish surface of concrete complete all as specified and directed.
M&L for form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concrete complete all as specified and directed.
M&L for form work to sides of pillar, posts, struts, piers, columns and stanchions for flat, rough finish surface of concrete complete all as specified and directed.
M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges for flat, rough finish surface of concrete complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs exceeding 10 cm but not exceeding 20 cm wide for rough finished surfaces of concrete, flat complete all as specified and directed.
M&L for formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
S&F for second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints of second class hard wood etc complete all as specified and directed.
M&L for second class hard wood in scantling, clean swan as in frame work, fixed with nails complete all as specified and directed.
S&F for 35mm thick (factory made) plain, second class hard wood, framed, panelled shutters (three panels) with lock rails and panel of 12 mm veneered particle board with commercial veneering on both faces (BWR type), the size of rail and stile as per IS-1003 (Part-I) (larger size to be provided) klin seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed.
S&F for 35mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made), open rebated & prepared to receive glass, gauge etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR part-I, section-8, clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
S&F for factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing complete all as specified and directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified and directed.
S&F for 300mm long, MS ordinary rat tail rod pattern spring including roller & roller plate complete all as specified and directed.
S&F for 300 mm aluminum alloy, anodised, sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F for 250 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F for 100 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F for 75 mm long stailess steel butt hinges complete all as specified and directed.
S&F for 25mm dia aluminium, powder coated (wood colour finished), single curtain rod (wall thickness not less than 1mm) including funnels etc as in repair complete all as specified and directed.
S&F for MS bracket (heavy duty), powder coated of best quality as approved by GE suitable for fixing 25mm bore curtain rod (CP) fixed in wall complete all as specified and directed.
S&F for stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
S&F for mild steel hold fast made out of flat iron (25mm x 3mm or equivalent size) including tarring or coal tar black paint and with drilling necessary holes etc conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed.
S&F for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates including where required drilling, fittings, riveting or welding connecting with fish plate, gusset plates etc of Fe-410-W (Gde E-250) quality 'A' complete all as specified and directed.
S&F for pressed steel frames (factory made) for door of size 165mm X 60mm of 1.25mm thick with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded crushed stone aggregate) with and including applying of two coats of black bituminous paint (shop coat) to back of chowkats complete all as specified and directed.
S&F for pressed steel frames (factory made) for door of size 105mm X 60mm of 1.25mm thick with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded crushed stone aggregate) with and including applying of two coats of black bituminous paint (shop coat) to back of chowkats complete all as specified and directed.
S&F for steel windows with side hung shutters (glazed ) including box type hinges with steel handle, steel peg stay, complete with glazing bars , dovetailed or welded to receive wire mesh/glass complete all as specified and directed
S&F for steel windows with side hung shutters (glazed ) including box type hinges with steel handle, steel peg stay, complete without glazing bars , dovetailed or welded to receive wire mesh/glass complete all as specified and directed.
S&F for steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and directed
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws after and including dismantling of existing unserviceable AC sheet complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws after and including dismantling of existing unserviceable AC sheet complete all as specified and directed.
S&F for false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee gird false ceiling using “T” Gird System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board (Make: Everest, type/pattern -oceanic or equivalent of Armstrong/Charminar) of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T gird Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Gird module to form after and including dismantling of existing unserviceable false ceiling complete all as specified and directed.
M&L for applying evenly a coat of oil based bitumen primer confirming to IS-3384 on roof, canopy, chajja, parapet (vertical surface etc) @ 0.40 Litre / Per Sqm by the same membrane manufacturer of density 250C, 0.87 to 0.89 litre and viscosity 70-160 cps after proper cleaning the roof surfaces (horizontal/vertical) and providing APP based polymeric membrane minimum weighing 3.6 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms / sqm) laid on primed surface with side over lap of 100 mm and end overlap of 150 mm, using bitumen torch or by LP gas torching and sealing all joints etc and ensuring complete thermo fusing and applying one coat of aluminum paint @100ml/Sqm over it all as per manufacturer's instructions complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base of floor complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection & hard standing including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate), as in sub base of floor complete all as specified and directed.
M&L for 40 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in floor/paving etc complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:6) for laying floor finishes after and including roughening of old concrete floor by picking, sweeping, clean and washing down with water to remove dust etc complete all as specified and directed.
All as per Item No.71.00 here-in-before but in skirting/dado over and including a backing coat of 10mm thick cement plaster in cement mortar (1:4) complete all as specified and directed.
S&F for glazed ceramic coloured wall tiles (vertical) 350mm x 250mm x 7mm / 450mm X 300mm X 7mm thick or equivalent set and jointed neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 10 mm thick cement plaster in cement mortar (1:4) complete all as specified and directed.
M&L for 20-22mm thick machine cut kota stone slab flooring (pre-mirror polished) over and including 20mm thick screed bed of cement mortar (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 20-22mm thick machine cut kota stone slab in riser of steps, skirting, dado and pillar laid over and including 10mm cement plastering in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for pre-polished coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick (glossy type), set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 20 mm thick cement screed bed in cement mortar (1:6) complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on other than fair faces of brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 20 mm thick rendering in wall, 1st coat 15mm thick in cement mortar (1:6) & 2nd coat 5mm thick in cement mortar (1:4) mixied with water proofing compound as per manufacturer's instructions, plastered surface shall be finished even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately, WPC shall be used in second coat only)
M&L for rendering 5mm thick in cement mortar (1:3) on ceiling, chajja etc surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick cement screed in cement mortar (1:3) on concrete surface (roof) mixed with WPC as per manufacturer's instruction for laying APP membrane complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for applying three coats of white wash on wall surface including preparation of new plastered surface complete all as specified and directed.
M&L for applying three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and directed.
M&L for two coats of white wash on old plastered surfaces of wall after preparation of old plastered surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty on old decorated plastered surface of wall after and including complete removal of existing treatment and preparation of surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3 mm thick wall care putty on wall after preparation of newly plastered surfaces complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying two coats of cement based paint on old plastered surface of walls after complete removal of existing treatment complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint after preparation of old wooden surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
S&F for 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F for 4mm thick figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 sqm each pane after acomplete all as specified and directed.
S&F for 15mm dia bib taps, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed as in repair complete all as specified and directed.
S&F for 15 mm bore angular stop valve, fancy type, chromium plated , cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions as in repair complete all as specified and directed.
S&F for 15mm dia pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes as in repair complete all as specified and directed.
S&F for brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges as in repair complete all as specified and directed.
S&F for 125mm size brass chromium plated shower roses with arms, swivel joints, including fixing to steel pipe or union as in repair complete all as specified and directed.
S&F for 15 mm dia PVC connection pipe of length 600 mm with PTMT nuts as in repair complete all as specified and directed.
S&F for 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing steel tubing complete all as specified and directed.
S&F for 20mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing steel tubing complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor, trench etc.) for 15 mm bore pipes with new fittings etc after and including taking up or down existing steel tubing and cleaning the same for reuse complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor, trench etc.) for 20 mm bore pipes with new fittings etc after and including taking up or down existing steel tubing and cleaning the same for reuse complete all as specified and directed.
S&F for 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer), ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection including dismantling / taking down old PVC water tank, ball valve etc all as specified in SSR Part-I complete all as specified and directed.
S&F for vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern but including flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2) securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement as in repair complete all as specified and directed.
S&F for vitreous china wash basin, white, flat back, size 550 X 440 mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand as in repair complete all as specified and directed.
S&F for vitreous china wash down water closet pan (pedestal pattern) white with P or S trap (excluding flushing cistern & flush pipe) including connection to trap & to flushing pipe, anti-syphonage pipe & seat cover etc. as in repair including making good to floor complete all as specified and directed.
S&F for 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor as in repair complete all as specified and directed.
S&F for vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests with P or S trap (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floors with PCC bedding (1:5:10) type E2 using 40mm nominal brick ballast and connection to trap with cement mortar, and making good to floor after and including demolition of PCC / lime concrete bedding of existing pan as in repair complete all as specified and directed.
S&F for 32mm waste coupling of PTMT (half and full threaded) (minimum weight 45gms) completed all as per specified and directed.
S&F for 125 mm dia grating doom PTMT (minimum weight 40gms) complete all as specified and directed.
S&F for 32 mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall or in floors etc. as in outlet pipe for WHB, urinal etc. complete all as specified and directed.
S&F for 100mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, laid in trenches or in floors or fixed to walls after and including dismantling of CI or reinforced concrete pipe complete all as specified and directed.
S&F for 100 mm dia cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) complete all as specified and directed.
M&L for 100mm dia cast iron nahani trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) as in repair complete all as specified and directed.
S&F for 100 mm cast iron cowls complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of top cover , blanking plate as per numbers of switches, sockets, fan regulators, blank plates etc as approved coloures accessories of suitable and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as sunken box, top cover , blank plate, MS box, screws, washers etc are to be used of same make/brand only and cost of the same shall be deemed to be included in quoted rate only.)
One light point controlled by one switch .
One ceiling fan/exhaust fan point controlled by one switch .
One 3 pin 5 amps socket point controlled by one 6 amps switch on independent board .
One 3 pin 5 amps socket point controlled by one 6 amps switch on same board .
All as per Item No.121.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of 3 pin, 15/16 Amps socket outlet on independent board complete all as specified and directed .
S&F for stepped type (0-4/5 step) electronic fan regulator for ceiling fan 1200 mm, 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing complete all as specified and directed.
S&F for ceiling rose , surface bakelite 65X50mm, three terminal, PVC/polycarbonate body complete all as specified and directed.
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 and15/16 Amps, 240 volts, AC, ISI marked complete all as specified and directed.
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC complete all as specified and directed.
S&F for switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F for switch piano flush button single pole one way 15/16 amp 240 volts, AC, ISI marked complete all as specified and directed.
S&F for batten holder /angle lamp holder, PVC/polycarbonate type, ISI marked complete all as specified and directed.
S&F for decorative box type 20 -22watt LED fitting with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC as approved for LED lamp as approved)
S&F for 36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cable with and including street light bracket made out of GI pipe of 40mm dia medium grade bent to shape of 1.2 mtr long including clamps made out of 40 mm x 6 mm flat iron for fixing bracket including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer after and including taking down street light fittings alongwith brackets complete all as specified and directed. (Make : Crompton Greaves Cat No LSTS-36-CDL-M/ Bajaj Cat No BRTFG 36W LED as approved)
S&F for 36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cable with and including street light bracket made out of GI pipe of 40mm dia medium grade bent to shape of 1.2 mtr long including clamps made out of 40 mm x 6 mm flat iron for fixing bracket including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. (Make : Crompton Greaves Cat No LSTS-36-CDL-M/ Bajaj Cat No BRTFG 36W LED as approved)
S&F powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way / Hager cat No.VYS08D / L&T Cat No.DBSPN008GD as approved)
S&F for powder coated sheet metal enclosure with metal type acrylic door, 415 volts, AC, VTPN DB (V-vertical type distribution board) 4 way plus 24 modules, for flush mounting with 200amps copper busbar, 2 neutral/earth bar for ease of installation and MCCB incomer of rating upto 200Amps, FP and MCB SP /TP MCB's as outgoing and complete connecting cable links with top and bottom with IP43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat as in repair complete all as specified and as directed. (Make: Legrand cat No.5077 30, 4 way / Hager Cat No.VYVO4DM-P / L&T Cat No.DBVTH004DD as approved)
S&F for powder coated sheet metal enclosure acrylic door 240 volts AC,SPN distribution board 4 way for flush mounting with 100 amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 100 Amps, MCB SPN/DP and MCB SP, 10KA as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed. (Make:- Legrand cat No. 5076 20 4 way / Hager cat No.VYS04D / L&T Cat No. DBSPN004GD as approved).
S&F for MCB SPN 32 Amps, 10 KA, 'C' series, AC, 240Volts, 50Hz, ISI marked complete all as specified and directed.
S&F for MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
S&F for MCCB, 63 Amps, 3 pole, 16KA breaking capacity Icu at 415 Volt with thermal magnetic release, 50 Hz after and including taking down existing unserviceable MCCB complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically (earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value complete all as specified and directed. (Galvanised iron wire of 4mm dia upto 7.5m including testing consider in this item).
S&F for heavy duty type exhaust fans AC single phase 230/240 V of size 300 mm sweep, 900 RPM with louver and necessary connection, testing including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects complete all as specified and directed. (Make : Havells model No Turbo Force SP 300mm-900RPM or equivalent model of Crompton Greaves as approved)
S&F for ceiling fan of size 1200 mm sweep, BEE 5 Star, high speed, single phase, 240Volts, AC, 50Hz, as approved colour and including hanging GI hook with necessary suitable MS clamps and connecting cable three core 0.75 sqmm round PVC sheathed from ceiling rose to fan connector and testing complete all as specified and directed. (Make:- Havells model No. Samraat or equivalent model of Crompton Greaves/Usha/Bajaj as approved)
Taking down ceiling fan of 1200/1400 mm sweep by unscrewing nut/bolts from its position and re-fixing the same to its original place after necessary cleaning, oiling, greasing, connecting wire from ceiling fan to ceiling rose or connection complete all as specified and directed.
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 10 sqmm, 2 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 16 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking down existing cable of any type and any size complete all as specified and directed . (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed.
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work after and including taking down of old existing one complete all as specified and directed . (Note : Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity, one run of PVC conduit and chase cutting shall be measured as one unit)
S&F for water storage heater (geyser) of 25 ltrs capacity, vertical type with copper inner tank, 240 volts, AC, 50Hz and fixing arrangement on wall including providing hole fastners-04 nos, hot & cold water PVC pipes 15 mm bore approximate 600 mm long -2 Nos, chromium plated brass stop cock 15 mm bore -01 No and including necessary plumbing work, tesing complete all as spcified and directed. (Make: Havells/Crompton Greaves /Racold as approved)
M&L for GI pipe 50mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, floors, on roof, on pole for cable protection complete all as specified and directed.
M&L for GI pipe 40mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, on wall, floors, on roof, on pole for cable protection complete all as specified and directed.
M&L for boring holes horizontally under road without damaging the surface of road (minimum 1.0m bellow the road surfaces) with the help of GI tubing of any dia not exceeding 100mm dia for passing of UG cable complete all as specified and directed.
BARRACKPORE ELECTRONICS
S..S. ELECTRIC CO.
DEYS ENTERPRISE
M/S D K Singha
RISING ENTERPRISE
M/S PAUL CONSTRUCTION
MANOJ CONSTRUCTION
B.N. SADHUKHAN
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .