| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹30.4 L+₹3.4 L (12.7%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L2 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹86,800
Closing Date
23 Dec 2021, 6:00 pmClosed
GE (AF) CHILODA
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
PROVN OF THREE TIER WASHING SYSTEM, GREASE TRAP, WORK SERVICES FOR INSTALLATION OF TTLE, REPLACEMENT OF ROOF WITH GALVALUME SHEET, SPECIAL REPAIRS TO TOILETS AND CERTAIN SANCTIONED WORKS AT VARIOUS LOCATIONS OF AF STN GANDHINAGAR UNDER GE (AF) CHILOD
2021_MES_480881_3
8964/21-22/E8
Open Tender
Civil Works
Item Rate
180 days
Gandhinagar
AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (AF) CHILODA
₹86,800
Yes
28 Jan 2022
1 Dec 2021
25 Dec 2021
1 Dec 2021
23 Dec 2021
11 Dec 2021
Amount
Surface dressing n. exc. 15cm including clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth and trees not exceeding 30 cm girth complete all as per specified and as directed.
Excavation in trenches, n. exc. 1.5m wide and n. exc. 1.5m in depth for foundations etc. n. exc. 10 Sqm on plan and getting out in hard/ dense soil complete all as per specified and as directed.
All as per Item No. 2.00 above but exc. 1.5m depth complete all as specified and as directed.
Excavation in trenches in soft/ loose soil not exceeding 1.5 meter deep and not exceeding 1.5 mtr width and getting out including forming bottom surface to required slope/ gradient for laying pipes etc. complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the pipe etc. are laid, jointed and tested complete all as specified and as directed by Engineer-in-Charge.
Removal of surplus excavated spoil not exceeding 50 mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Demolition for cement concrete/ bituminous road in ground floor and paving n. exc. 15 cm thickness below or above ground level complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregates) as in copping, as in floor/ road finishing even and fair, as in making cement concrete thrust block for supporting of pipe bend, tee, dead end etc. including any necessary work or in any other situation work complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B2 (using 40mm graded stone aggregates) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for use and waste of formwork to sides of footing and stanchions rough finished surfaces of concrete circular on plan complete all as specified and as directed.
M&L for RCC M-25 (Design mix) (using 20mm graded stone aggregates) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc. complete all as specified and as directed.
M&L for use and waste of formwork to sides of pillars, posts, struts, piers, columns, and stanchions rough finished surfaces of concrete circular or plan complete all as specified and as directed.
M&L for RCC M-25 (Design mix) (20mm graded stone aggregates for columns, pillars, piers, posts and struts etc complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips and including welded with new reinforcement to existing reinforcement and grouting of beams/ columns/ lintels etc complete all as specified and as directed.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spaces and binders, cut to length bent to shape required, including crancking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9 mm dia or securing with clip quality complete all as specified and as directed.
S&F hand rails, half round or other steel section or core for wooden hand rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for brick work with sub class 'B', old size bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Cutting into existing manholes for connecting new drains of internal dia 150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 smooth finished and reforming benching as required complete all as per specified and as directed by Engr-in-Charge.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregates) as in sub base etc. complete all as specified and as directed.
M&L for rendering 10mm thick plaster in CM (1:6) on fair faces of brick work or concrete surfaces of walls finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick on brick or concrete surfaces in cement mortar (1:4) finished even and fair without using extra cement complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:4) to receive tiles etc on vertical surfaces of walls complete all as specified and as directed.
M&L for rendering 15mm thick in CM (1:4) on brick work concrete surfaces or similar surfaces etc. complete all as per specified and as directed.
M&L for 15mm thick screed bed or bedding layer in CM (1:6) for laying floor finishes complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for preparing new surface of wall and applying two coats of oil emulsion distemper over a coat of chalk whiting complete all as specified and as directed.
M&L for preparing of new surfaces of walls and applying one coat of cement based paint complete all as specified and as directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and as directed.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for glazed ceramic coloured tiles in vertical surfaces 300mm x 200mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for glazed ceramic coloured tiles in vertical surfaces 350mm x 250mm x 7mm/ 450mm x 350mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for vitrified ceramic tiles 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match premium quality as in floor etc. complete all as specified and as directed.
All as per Item No. 33 above but on vertical surfaces/ skirting.
M&L for granite 18 to 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L for 20-25mm thick machine cut and polished kota stone as in flooring, shelves, platform or similar works including cutting grove in the walls or laid on any support and fixing of stone in CM (1:3) all including rubbing and polishing complete all as specified and as directed.
M&L sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for glossy finished pre-polished coloured machine pressed precast concrete interlocking paver block any shpe and size confirming to IS : 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigments, rubber mould finish laid in floor etc. complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS : 1161-1998 grade St.-240 complete all as specified and as directed.
Dismantling plain or corrugated steel/ fibre translucent sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
S&F pre-painted galvalume aluminium zink coating GI based corrugated steel sheet 0.50mm thick of colour having tensile strength of 550Mpa as in roof covering fixed with self tapping screws complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50mm thick of colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed.
S&F rotational moulded water storage tank 1000 Ltr capacity double layer (cylindrical/ vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
Supply and laying 25mm dia bore GI tubing medium grade including GI fittings like sockets, elbows, bends, Tees, unions, short pieces etc. laid in trench complete all as specified and as directed.
S&F in repairs 40mm size waste pipe for wash hand basin/ urinal/ sink complete all as specified and as directed.
S&F in repairs 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S&F 110mm bore PVC (SWR) bends any redius complete all as specified and as directed.
S&F elbow operated lever pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed to 15mm bore pipe completed all as specified and as directed. Make:- Product code : FLR-CHR-5031N of Jaquar or equivalent make as approved by GE.
S&F aluminium powder coated (three track) sliding windows with frame of size 92mm x 31.75mm x 1.50mm and shutters of size 42mm x 18mm x 1.50mm with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete and stainless steel wire mesh 0.36 mm nominal dia of wire with 1.40mm average width of aperture and fixed with stainless steel wire staples and fixing 5 mm thick glass with necessary rubber beading, gasket etc. complete all as specified and as directed by Engr-in-Charge. Note:- Glazing/ wire mesh shall be included in the unit rate.
S&F aluminium windows (double track)/ ventilator powder coated of section 85.00mm x 31.75mm x 1.50mm thick shutter of section 19mm x 40mm x 1.5mm with rubber gasket beading and locking arrangement etc complete all as specified and as directed. Note:- Glazing/ wire mesh shall be included in the unit rate.
S&F aluminium powder coated grill 6 mm thick fixed to walls with and including 'H' or 'F' aluminium channel of size 38mm x 12mm x 1.50mm complete all as specified and as directed.
S&F in repairs aluminum powder coated door shutter, aluminium section weighing not less then 0.55 Kg/ m including necessary jointing cleats, glazing clips rubber neoprene packing including (a) 150mm handle - 02 Nos. (b) Stainless steel hinges - 100mm - 03 Nos. (c) Mortice lock in built 3 lever - 01 Nos. in each shutter, aluminium anodized snap beading screw etc complete all as specified and as directed. Note:- Glass and particle board shall be paid measured and separately.
S&F in repairs 4.8mm thick tinted glass fixed to aluminum frame work with rubber beading gasket complete all as specified and as directed.
Cutting channels, grooves or rebates n. exc. 15 cm girth and trimming surface with or without reinforcement complete all as specified and as directed.
M&L for SS Sink Grade-304, size 500mm x 450mm x 300mm and 1.62mm thick complete all as per specified and as directed by Engr-in-Charge.
S&F 75mm bore PVC (SWR) junction double, (double T), equal or unequal or as per directed by Engr-in-Charge.
S&F PVC (SWR) 75mm bore bends any raduis complete all as specified and as directed.
S&F 20mm ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
S&F 15 mm water tubes, 'meduim grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S&F stop valves, cast copper alloy, screwed down, high pressure, with crutch orbutterfly handle, screwed bothends for iron pipe or fo runions and fixed to 15mm bore pipe complete all as specified and as directed.
S&F 40mm brass chromium plated waste coupling for wash hand basin complete all as specified and as directed.
S&F 15mm CP hot and cold mixer 2-in-1 with flange wash basin/ sink complete with all fittings complete all as specified and as directed.
S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F SS oil and grease trap (Grade-304) for 100 users, size (1000 x 750 x 600)mm 1.62mm thick complete all as per specified and as directed by Engr-in-Charge.
S&F 110mm bore PVC (SWR) junction double, (double T), equal or unequal or as per directed by Engr-in-Charge.
M&L for point wiring for one light/ fan point controlled by one switch, with 1.5 Sqmm single core PVC insulated unsheathed multi stranded copper conductor FRLS cable 1100 V grade drawn through and including PVC casing in capping/ conduit with accessories like bends tees, junction boxes etc fixed recessed in wall or ceiling etc including 1.5 Sqmm single core PVC insulated but unsheathed multistrandard copper conductor FRLS cable 1100 V grade as earth continuity wire incl sunken type pressed steel terminal boxes of size with 3mm thick bakelite steel white/ coloured top complete all as specified and as directed.
All as per Item No. 69 above but one 3 pin socket outlet 5 Amps on the independent board.
All as per Item No. 69 above but one 3 pin socket outlet, 5 Amps on the same board with other switches.
M&L for point wiring with 2.5 Sqmm (nominal area) single core PVC insulated FRLS un-sheathed multi-stranded copper conductor cable (maintaining colour code), 1100 Volts grade drawn through concealed PVC conduit with accessories like bends tees, junction boxes etc fixed recessed in wall or ceiling etc including 2.5 Sqmm single core PVC insulated but unsheathed multistrandard copper conductor FRLS cable 1100 Volts grade as earth continuity wire including moduler metal flush box with cover plate and frame etc. for one socket outlet 3 pin 15 amps as required at site complete all as specified and as directed.
S&F switch modular single pole, one way, 5 Amp, complete all as specified and as directed by Eng-in-Charge.
S&F switch modular type, single pole, one way, 15 A, complete all as specified and as directed by Eng-In-Charge.
S&F fan regulator step type moduler, 120 W, 240 Volts complete all as specified and as directed by Eng-in-Charge.
S&F ceiling rose 3 terminal/ poly carbonate, isolated body complete all as specified and as directed.
M&L for sub main wiring complete with PVC insulated cable of single core 04 Sqmm (FRLS) 1100 Volts grade with multi stranded copper conductor for drawn through and including PVC casing-capping with accessories including 4.0 Sqmm unsheathed multi stranded copper conductor as on earth wire. Note:- Two runs of single core cable with one run of earth continuity cable including PVC casing capping and its accessories will be measured and paid as one unit.
S&F socket, 6 A - 2/3 pin, combined, 2 module type complete all as specified and as directed by Eng-in-Charge.
S&F socket 6 A/ 16 A - 2/3 pin, combined, 2 module complete all as specified and as directed by Eng-in-Charge.
M&L in repairs/ replacement of submain wiring with two single core 4.0 Sqmm (nominal area) PVC insulated FRLS unsheathed multi-stranded copper conductor cable 1100 Volts grade drawn through PVC casing caping complete including 4.0 Sqmm PVC insulated unsheathed multi-stranded FRLS single core copper conductor cable for earth wire including taking down/ removing old one and making good disturbed surfaces etc, complete all as specified and as directed. Note:- (i) Two runs of single core 4.0 Sqmm multi-standard copper cable and one run of 4.0 Sqmm earth wire shall be measured as one run length. (ii) Extra length of cable required for connection to DBs/ MCBs shall deemed to be included in unit rate quoted by contractor against the item.
S&F MCB single pole and neutral (SPN), 16 to 32 Amps, 240 Volts, 10 KA, ‘C’ series, with all incoming/ outgoing connections with proper size lugs complete all as specified and as directed.
S&F MCB single pole (SP) 6 to 32 amps, 240 Volts, 10 KA, ‘B’ series with all incoming/ outgoing connections with proper size lugs complete all as specified and as directed.
S&F sheet metal enclosure for DB, double door type, single pole and neutral (SPN) 240 Volts with rated bus bar 8 ways suitable for housing MCBs etc complete all as specified and as directed.
S&F ceiling fan five star rated, 230 Volt,1200mm sweep complete with blade, canopy and down rod and connecting up to and including provision of flexible three core copper conductor cable from ceiling rose to connector block complete all as specified and as directed by Eng-in-Charge.
S&F LED lights fitting 1x18 W, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling complete all as specified and as directed.
M&L for laying and jointing pipes galvanized 15mm bore 'medium grade' with all fittings fixed to walls and ceilings or laid in floors/ trenches including testing complete all as specified and as directed.
M&L for laying and jointing pipes galvanized 20mm bore 'medium grade' with all fittings fixed to walls and ceilings or laid in floors/ trenches including testing complete all as specified and as directed.
S&F gun metal gate/ globe valve heavy duty (ISI marked) of size 15mm dia bore with iron wheel head screwed both ends for iron pipe including testing complete all as specified and as directed.
M&L for drilling in DI pipe upto 200mm dia and tapping GI pipe branch connections of 20mm dia including saddle piece and nuts and bolts complete all as specified and as directed.
M&L for boring under road/drain by manual method for inserting the GI tubing up to 25mm dia complete all as specified and as directed by Engineer-in-Charge.
S&F hylam laminated sheet 3 mm thick for mounting, switches, sockets, fan regulator etc. suitable for 08 switch and 02 Nos fan regulator complete all as specified and as directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed.
S&F GI tubing 40mm, medium grade in wall for hanging of ceiling fans including cutting holes in walls built in cement mortar and making good in cement sand mortar (1:4) and finish the surface to match with existing complete all as specified and as directed by Engineer-in-Charge.
S&F MS clamp made out of 30mm x 5mm MS flat iron conforming to grade Fe-410-O or Fe-310-O made to shape suitable for fixing on 40mm dia pipe making necessary holes for nuts and bolts in clamp including 12mm dia MS bar one end flattened and provided with holes for tightening to flat iron clamp with nut and bolts and other end bend to semi circular shape as directed for hanging of ceiling fan, with and including GI nuts and bolts of suitable dia and length complete all as specified and as directed.
S&F for storage water heater (Geyser) 50 Ltrs of capacity verticle mounting type electric driven (single phase), not less than 5 Star rating (BEE) and grouting new suitable size anchor fastner in wall and mounting geyser on anchor fastner and writing MES No on geyser and testing complete all as specified and as directed.
S&F for switch socket outlet combination, multipurpose, three pin, 15 Amps and three pin 5 Amps controlled by one switch, flush type, 230 Volts AC circuit complete all as specified and as directed.
S&F for ball valve GM suitable for 20mm bore of pipe both side thread complete all as specified and as directed.
S&F PVC flexible connection pipe nylon braided hot and cold type 15mm dia 600mm long with brass fly nut at both ends complete all as specified and as directed.
Supply, installation and testing for hi wall digital inverter split units AC with indoor and outdoor unit complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and electric driven single phase of capacity 1.5 TR complete all as specified and as directed.
S&F wall mounted 15 Amp capacity digital voltage stabilizer, for automatic voltage correction single phase, naturally air cooled, indoor type, designed for or input voltage of 170 V to 270 V and output voltage stabilized between 230 V with accuracy of 2.5% complete all as specified and as directed.
S&F industrial type sheet metal enclosures with a two pin and earth plug and socket, 250 Volts with including 20 Amp SPN MCB complete all as specified and as directed.
S&F for MCB single pole with neutral, 20 to 32 Amps (`B’ series ) having current rating 10 KA complete all as specified and as directed.
M&L for submain wiring using two single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 10.0 Sqmm of voltage rating upto and including 1100 Volts drawn in and including PVC casing capping of size not less than 20mm with standard accessories fixed on walls/ ceiling surface along-with one run of FRLS PVC (green colour) insulated, unsheathed, stranded copper conductor of size 10.0 Sqmm as earth continuity conductor complete all as specified and as directed. Note:- Two runs of single core cable with one run of earth continuity cable including PVC casing capping and its accessories will be measured and paid as one unit.
Supply, fixing, connecting and testing sheet metal enclosures double door type for DBs for using MCBs/ MCB isolators suitable for single pole and neutral, 4 way with having copper bus bars suitable for 200 Amps rating complete all as specified and as directed. Note:- Fittings like MCB’s/ Isolators etc. shall be measured and paid for separately under respective items.
Supply, installing and testing indoor type isolation transformer, double copper wound of capacity 10 KVA, 240/ 240 Volt, (at no load) 50 Hz, AC single phase, ONAN cooled, oil immersed, after continuos full load run on an ambient temperature of 40 degree celcius, The isolation transformer shall be comply latest IS/ BIS standard complete with standard fittings/ accessories and cable entry box complete all as specified and as directed.
ARTI CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .