Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC 201 JITENDRA LODGE BUILDING 20 NEW JAGNATH PLOT RAJKOT | RAJKOT | RAJKOT | GUJARAT | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.7 L+₹26,345.72 (2.80%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹9.7 L+₹31,440.06 (3.34%)Rejected-Finance | L3 | Rejected-Finance L1 |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
17 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I A Jamnagar
INFANTRY LINE JAMNAGAR
PROVN OF B VEHICLE GARAGE FOR 382 COY ASC (SUP) TYPE A AT BG LINES JAMNAGAR
2020_MES_362166_1
8747
Open Tender
Civil Works
Item Wise
120 days
Jamnagar
AS PER TENDER
6 documents required · 6 mandatory
₹500
Yes
₹26,000
Yes
9 Sept 2020
20 Jul 2020
18 Aug 2020
27 Jul 2020
17 Aug 2020
27 Jul 2020
60 days
Amount
Surface dressing not exc 15 cm deep in soft/loose soil complete all as specified and directed.
Excavation in trenches n.exc 1.5m deep & n.exc1.5m wide on plan in soft/loose soil and getting out complete all as specified and directed.
M & L Plain cement concrete (1:3:6) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete all as specified.
M&L for plain cement concrete type D2 1:4:8 (40 mm graded aggregate) as in foundations, filling and mass concrete, complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape required including cracking bending hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia as in reinforcement of fencing posts, columns, plinth beams in fencing all as specified and directed.
Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
S&F TMT bars 6 to 8 mm dia , cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia, complete all as specified & directed.
M&L form work to soffit of slab flat not exceeding 200mm thick horizontal or sloping rough finished surface complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, plinth beams; and similar work; vertical or to batter complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
M&L for RCC M - 25 Design mix Slabs supported on walls, beams and columns in floors roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for RCC M - 25 Design mix Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC M - 25 Design mix Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for RCC M - 25 Design mix Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil.
Removing excavated material n exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L precast cement concrete block masonry with solid block, type C-1,1:3:6 mix ( using 20mm graded aggregate ), exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M & L hardcore of broken bricks of gauge n.exc.63mm,deposited,spread and levelled in layers n exc. 15 cm thick, watered and well rammed to a true surface complete all as specified and directed.
M/L for PCC 1:5:10 type E2 over 100 mm thick hard core as in sub base of floor complete as directed by Engr-in-Charge.
M&L 100 mm thick M-20 (Nominal mix) Type A-1, Plain cement concrete with using 20mm graded aggregate laid inalternate bays over sub base finished even and fair without using extra cement complete all as specified and directed.
M&L 100 mm th PCC 1:2:4 type B-1 using 20 mm graded aggregate as in flooring, finished fair and even complete all as specified and directed.
M&L for forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound,Grade ‘A’, complete all as specified and directed. Make:Tikitar or equivalent ISI marked.
M & L rendering 10 mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified.
M & L rendering 15 mm thick on brick wall or concrete surface in cement mortar 1:4 mixed with water proofing compound at the rate of 3% by weight of cement, finished even and fair complete all as specified and directed. (Note:- Water proofing compound shall be measured and paid saperately.)
M & L rendering 5 mm thick on ceiling in cement mortar 1:4 finished fair and even smooth without using extra cement complete all as specified
M&L for preparation of newely plastered surfaces of wall and applying two coats of oil bond distemper and over one coat of primer on walls
M & L for preperation of new plastred surface of wall and applying two coats of exterior emulsion paint over one coat of primer all as per specified and directed
M & L applying two coat of white wash on newly plastered wall surface of ceiling including preperation of the surface complete all as specified.
M & L 75 mm th PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified.
M&L screed bed 15 mm thick CM 1:4 on top of roof mixed with water proofing compound at the rate of 3% by weight of cement, finished even and smooth complete all as specified and directed. (Note:- Water proofing compound shall be measured and paid saperately).
Supply only water proofing compound
M&L providing, cement concrete Type B1 (1:2:4) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross sectional area, single core, pvc insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC Concealed conduit of dia not less than 20mm and conduit accessories concealed in wall, ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes (with earth duly) duly painted with two coats of anticorrosive paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3mm thick Hylam laminated sheet cover for fixing of switches, sockets etc including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dully complete all as specified and directed at site for the following : (a) One light/ Fan point controlled by one way switch.
S&F switch piano flush type single pole one way 5 Amps 230 V.
S& F Ceiling rose, 3 terminal Poly carbonate body.
Supply& Fixing LED batten fittings 4ft 20 Watt (Min 1900 lumens) with clamps incl PVC gutties and flexible wire and connecting to ceiling rose complete . Model Wipro Garnet 20W , D562065 of Wipro or Eq model in Philips/Osram.
S&F DB sheet metal enclosure 2 way SPN for mounting MCB .
S&F MCB DP 10 to 40 Amps B series all as specified and rupturing capacity 10 KA,
Supply, fixing, testing and commissioning 30W LED security light fitting with system output of 3000 lumens & with dedicated street light optics, System efficacy of greater than 100lm/W luminarie should have pressure die cast aluminium LM6 housing. Luminaire should have dedicated street light optics for better uniformity & spacing. Luminarie should have air vents in housing for proper thermal management. Min IP preventation should be IP65. System power consumption (including driver losser) should not exceed 20W.Make:LSTS-30-CDL of Crompton and euivalent in other make Wipro/Havells
S& F security light bracket made out of GI pipe 40mm light grade ISI marked 1.5 Mtr long bend to shape as required for LED fittings at site including M S Clamp 2 Nos made out of flat iron 50 X 5mm with necessary nuts Bolts and two coats of alluminium paint over a coat of red oxide primer all as directed.
M&L Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in grond (earth pit not less than 2.25 mtrs below normal ground level) with the top edge of the plate not less than 1.5m below the normal ground level connected to GI wire 4.00mm dia protected by 15mm bore GI pipe (light grade) and watering pipe 20mm bore GI pipe(light grade) and PCC Pit (1:3:6) type C1 using 20mm graded stone aggregate with RCC cover including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No-3 of SSR part-I and as specified including earth plate packed around with charcoal dust common salt complete including GI sheet funnel, wire mesh, earth lead wire 4mm dia and earth lead connected to earthing test point/ main board. The GI earth wire 8 SWG under the earth and on pole/db upto a height of 1.5m shall also be protected by 15mm dia GI pipe (light grade ) and the GI pipe to be fixed with poles/wall by means of 02 Nos. GI clamp 25x3mm with nuts bolts and washer etc. complete all as specified and directed by Engineer-in-Charge. Note :- GI earthing wire of same size upto 7.5m shall deemed to be included into quoted rate
Supply & Laying cable of 10 Sqmm x 2 core, only in trenches / poles / walls XLPE insulated, armoured, Heavy duty electric power cable with aluminium conductor 1100 volts grade for following size with lugs including taking out old unserviceable cable complete all as specified and directed .
Excavation in trenches not exceeding 1.5 m wide in depth and getting out soft/loose soil for laying of cables etc complete all as directed .
Returning filling including spreading levelling watering and well ramming in layar not exceeding 25 mm thick complete all as specified and as directed by Engineer in charge
Removal of excavatede material (soil) to a distance not excedding 50 m and depositing where diredted at a level not exc 1.5 m above the starting point complete all as directed by Engineer in charge
M&L dry river sand in trenches for cable cushioning & protection including spreading, ramming all as specified and directed.
Supply & Laying precast PVC cable concrete cable cover LV voltage type -I flat size 250 mm x 150 mm x 40 mm complete
S&F GI Pipe light grade 40 mm for road crossing/ on pole/ on wall for protection of LT Cable laid in trenches, fixed to wall/pole including MS clamps etc. as directed by Engr-in-Charge
Badri Electricals
badri glass and construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .