Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹37.1 LAccepted-AOC A 20 SHIVANI COMPLEX VIDHYA VIHAR OPP BARKATULLAH HOSHANGABAD ROAD BHOPAL MADHYA PRADESH 462026 UDYAM MP 10 0013154 23AAECC2242H1Z6 R M MSME STATUS AS VERIFIED | BHOPAL | MADHYA PRADESH | 462026 | 1 | Accepted-AOC L1 |
Tender Value
₹35.6 L
EMD Value
₹71,260
Closing Date
12 Aug 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
General Manager HWPM
O/o General Manager HWPM Bhadradri Kothagudem Dist Telangana State 507116
Please refer Tender Docs
2024_HWB_814297_1
HWPM/CIVIL/MP/NIT/2024/38
Open Tender
Civil Works
Item Rate
120 days
HWPM
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹71,260
25 Nov 2024
15 Jul 2024
16 Aug 2024
15 Jul 2024
12 Aug 2024
15 Jul 2024
15 Jul 2024 - 27 Jul 2024
Amount
Providing and fixing 2mm thick Poly propylene glass sheeting over a base layer of FRP having a thickness of 1.5mm in horizontal/vertical faces of neutralization pits/channels etc., by using suitable adhesives as approved by the EIC, removing the existing damaged PPG lining, surface preparation complete as per specifications, drawings, including sealing of the new PPG Lining with additional Strip of 25mm Welding and Rod Welding by homogeneous fusion process to the base sheet, the joints have to be tested with spark testing in the presence of EIC or his authorized representative, all complete including handing over the damaged PPG lining to sectional stores. Note: All the requried machinery,materials, tools and tackles have to be arranged by the contractor only. It may be noted that, the work is required to be carried out during the common shut down of the plant. However, some areas can be executed during the plant operation as well. It may please be noted that, repair works if any like reinforced cement concreting, required reinforcement, 20mm thick water proof cement plaster and all finishing civil works will be paid under the Item No.2
Preperatory civil works like levelling the areas with suitable Reinforced cement concrete works of 1:1.5:3 grade using necessary reinforcement (if required), 20mm thick water proof cement plastering using 1:3 cement mortar in two layers and all other civil works like cement slurry grouting wherever required complete as per specifications, drawings for exeution of Item No.1. Note: All the requried machinery,materials, tools and tackles have to be arranged by the contractor only. It may be noted that, the work is required to be carried out during the common shut down of the plant. However, some areas can be executed during the plant operation as well.
Inspection & repairing of the existing PPG lining by removing the air voids and making good with suitable means like spark testing and repairing the joints and sheets using suitable adhesives and duly sealing the joints with welding by adding strip and rod in the damaged locations all complete as per specifications and as directed by the Engineer-in-charge. Note: Payment will be made based on the actural area of repair work carried out at site.
Providing and laying of Acid resistant bricks of size 230mm x 115mm x 38mm as per IS 4860 over a Polymer Based Mortar as per IS 4443 in Neutralization pits, channels in horizontal/vertical faces etc complete inlcuding removing of the existing damaged acid resistant bricks, surface preparation and levelling the areas with suitable Reinforced cement concrete works of 1:1.5:3 grade using necessary reinforcement (if required), 20mm thick water proof plastering using 1:3 cement mortar in two layers and all other civil works like cement slurry grouting wherever required including handing over the damaged acid resistant bricks to sectional stores & disposing the balance materials at designated places complete as per specifications, drawings and as directed by EIC. Note: All the requried machinery,materials, tools and tackles have to be arranged by the contractor only.
Inspection & repairing of the acid resistant brick Joints in the neutarlization pits/ channels and sealing of the joints with Polymer Base Material as per IS 4443 complete as per specifications and as directed by the Engineer-in-Charge. Note: Payment will be made based on the actural area of repair work carried out at site.
Rectification/Rejointing of the Existing HDPE Pipe of having outer dia 315mm including removing the existing damaged pipe, realigning the pipe to correct level and joining the same with welding including necessary bed concrete, dismantling of concrete etc complete as per specifications and as directed by the Engineer-in-charge.
Providing, laying & fixing of HDPE pipe of having outer dia 315mm (2.5kg/Cm2 pressure rating) inlcuding jointing with welding including removing the exisitng damaged HDPE pipe by dismantling the existing concrete and laying of bed concrete for the new HDPE pipe complete as per specifications and as directed by the Engineer-in-charge.
Providing and applying a layer of protective coating with solvent free epoxy paint of "Nitocote EP 140" of M/s. FOSROC or equivalent at 100 micron (wet) i.e 40 micron DFT including dismantling the damaged FRP lining wherever required, preparation of the surface, cleaning etc., complete as per specifications and as directed by the Engineer-in-charge.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .