| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED | |
| 2 | L2₹25.7 L+₹1.3 L (5.22%)Rejected-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 3 | L3₹29.2 L+₹4.8 L (19.8%)Rejected-AOC | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 4 | L4₹29.6 L+₹5.2 L (21.2%)Rejected-AOC | L4 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 5 | L5₹29.7 L+₹5.3 L (21.8%)Rejected-AOC | L5 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
Refer Docs
EMD Value
₹57,000
Closing Date
29 Jun 2023, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR AND REPLACEMENT OF STREET LIGHTS, CEILING FANS AND COOLING APPLIANCES AT MIL STN DHRANGADHRA
2023_MES_601266_1
GE(A)/GNR/TOKEN/28 of 2023-24
Open Tender
Civil Works
Item Rate
240 days
MIL STN DHRANGADHRA
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹57,000
31 Aug 2023
5 Jun 2023
1 Jul 2023
5 Jun 2023
29 Jun 2023
16 Jun 2023
5 Jun 2023 - 13 Jun 2023
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole,laying of cables etc in Hard and dense soil and getting out.
Excavating in trenches not exceeding 1.5m wide and exceeding 1.5 m but not exceeding 3.00m in depth for foundation of pole, laying of cables etc in hard/dense soil and getting out.
Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm.
Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point.
M&L for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note : Depth after punning shall be measured and paid.
M&L for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundtion of PCC poles,bed of pole /struts all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundtion of pole/stay assembly etc including necessary form work, all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed.
Taking out sub class burnt bricks from the trenches and stacking at site serviceable /unserviceable bricks for reuse.
Laying only sub class brunt bricks as cable protection cover all as directed.
Supply and laying sub class old 'B' burnt bricks laid as cable protection cover complete all as specified and directed.
Dismantling old unserviceable Steel poles/struts, any size complete all as specified and directed.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-31 (09 Mtr long) including two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of aluminium paint over one coat of red oxide primer to external/exposed surfaces complete all as specified and directed . Note:- (i) Excavation/PCC will be measured and paid separately under relevant items (ii) writing letters pole no and figures in white enamel of black Roman, Italic or Indian of 10 cm height including circular back ground with black enamel paint of two coats incl white circular border over steel
S&F, in repair, GI pipe, 40mm bore, light grade, laid below road/fixed along the poles / walls with necessary clamping, etc complete all as per specified and directed.
Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of following size with glands, cable protection pipes, cable route indicator etc., complete from the trenches/fixed on wall (or) passing through pipes/in floor removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make
6 Sqmm 2 core
10 Sqmm 2 core
10 Sqmm 4 core
16 Sqmm 4 core
25 Sqmm 3.5 core
Supplying & laying, XLPE insulated PVC inner sheathed of following size armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed.
6 sqmm 2 core .
10 sqmm 2 core .
10 sqmm 4 core .
16 sqmm 4 core .
25 sqmm 3.5 core .
M&L Painting to steel tubular poles LT of 8.5/9Mtr long incl fittings and fixtures complete, fixed with poles with one coat of alluminium paint incl scrapping of rusts and preparation of surfaces and writing letters and figures in white enamel of black Roman, Italic or Indian of 10 cm height including circular back ground with black enamel paint of two coats incl white circular border over steel/RCC surfaces of electric poles.etc., complete all as specified and as directed by Engr-in-Charge.
Taking down existing LED light fitting 25/45/70/90 W from LT poles ,cleaning of prismatic polycarbonate cover, remove the corban and reconected to ACSR conductor by using new aluminium service wire 2.5mm from conductor to LED street light all as specified and directed
Taking down and refixing existing LED light fitting from LT poles, and ,Supply & fix in replacement of UNSV electronic driver assembly the same as exixting for LED street light fitting of 25 watt all as specified and directed
Taking down and refixing existing LED light fitting from LT poles, and ,Supply & fix in replacement of UNSV electronic driver assembly the same as exixting for LED street light fitting of 45 watt all as specified and directed
Taking down and refixing existing LED light fitting from LT poles, and ,Supply & fix in replacement of UNSV electronic driver assembly the same as exixting for LED street light fitting of 70 watt all as specified and directed
Taking down and refixing existing LED light fitting from LT poles, and ,Supply & fix in replacement of UNSV electronic driver assembly the same as exixting for LED street light fitting of 90 watt all as specified and directed
Taking down and refixing existing LED flood light fitting from LT poles, and ,Supply & fix in replacement of UNSV electronic driver assembly the same as exixting for LED flood light fitting of 200 watt all as specified and directed
S&F, in repair, FRP insulated with PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, passing throuth existing pipe, fixed on pole/wall from juntion box to street light fitting including taking down old complete all as specified and directed.
S&F, in repair, LED flood light luminaire of 170watts with high pressure die cast housing with IP-66, power coated with gray colour finish, prismatic polycarbonae cover with LED lenses complete all as including taking down old Make - Bajaj or Chrompton/Havells/Philips all as specified and directed.
S&F, in repair, LED flood light luminaire of 120 watts with high pressure die cast housing with IP-66, power coated with gray colour finish, prismatic polycarbonae cover with LED lenses complete all as including taking dowo old per Make - Bajaj or Chrompton/Havells/Philips as all specified and directed
S&F, in repair, LED flood light luminaire of 100 watts with high pressure die cast housing with IP-66, power coated with gray colour finish, prismatic polycarbonae cover with LED lenses complete all as including taking dowo old as all specified and directed
S&F, in repair, LED flood light luminaire of 50 watts with high pressure die cast housing with IP-66, power coated with gray colour finish, prismatic polycarbonae cover with LED lenses complete all as including taking dowo old per Make - Bajaj or Chrompton/Havells/Philips as all specified and directed
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant including taking dowo old complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 66 protection
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant including taking dowo old complete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 66 protection complete
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant including taking dowo old complete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 66 protection complete
Supply and fix LT junction box for street light, FRP type with hinged type door and locking arrangement, off white colour, of size 300 x 200 x 105mm (internal) comprising of suitable size Aluminium busbar 3 rows with base insulation and 01 No earthing terminal bolt , nut and connecting up cables with terminal lugs all as specified and as directed .
S&F, in repair, PVC junction box, factory made, size 180x290x110mm with one No SP MCB of 06 Amp rating, class-B and 3 Nos connector fixed on pole with necessary clamps and bolts etc duly painted with two coats of aluminum paint over a coat of red oxide primer including connecting with street light cable including taking dowo old complete all as specified and directed.
S&F, in repairs, bracket made out of light grade, Galvanised steel tube, 25 mm bore, 1.2 Mtr length, bent to 120 degree for fixing street light fitting at the top, fixed to pole with necessary clamps made out of FI 40mm x 4mm with nuts & bolts including preparation of steel surfaces & apply two coat of synthetic enamel paint over red oxide prime rincluding taking dowo old complete all as specified and directed.
S&F, in repairs, bracket made out of light grade, Galvanised steel tube, 40mm bore, 1.2 Mtr length, bent to 120 degree for fixing street light fitting at the top, fixed to pole with necessary clamps made out of FI 40mm x 4mm with nuts & bolts including preparation of steel surfaces & apply two coat of synthetic enamel paint over red oxide prime rincluding taking dowo old complete all as specified and directed.
Supply, installation, commissoning and testing, in repair street light timer panel along with Conforms to IS/IEC 60947-4-1, Provided with Protection Degree IP 54 Extended wide band coil FRLS (Fire retardant low smoke) Internal wiring In-built Short-Circuit Protection with Digital 24 hour timer-01 no,Contactor Rating (A) 32 / TP40 / TPN-01no as per havells Cat part no IHXTS03060 or equivalent to L&T/ C&S/ ABB all as specified and directed
Supply, installation, commissoning and testing, in repair street light Time switch analog time switch,with Conforms to single phase, 230 volts with 24 hours time setting, current rating 16 Amps as per Havells cat part no.DHTED*50*6 or equivalent to ABB/ Seimens/ C&S
Supply, installation, commissoning and testing, in repair street light AC relay type ML-3 and with MCB TPN, C curve 32 Amp, three phase,
M/L for trimming of branches of trees touching LT electric over head line and making clear about 3 mtr in radius by climbing up tree or by providing ladder, at a height of 9 mtr and above and carrying and depositing where directed not exceeding 50 mtr. Note : (i) Necessary T & P items arrange by contractor. (ii) While cutting the tree branches the fallen branch damaged the contactor, insulator, pole the contractor should be replaced the said items without any extra cost.(ii) Cutting of tree consider in each span only not no of tree in one span have 10 trees it consider only one span.
Supply and fixing post top lantern LED type in repair 20watt 230 watt volts AC outdoor type with decorativepost top for 360 degree indirect light IP 65 protectionwith impact and corrosion resistant complete withdriver and lamp including taking down old one complete.make havells cat part CORALMINIPT25WLED 757PSYMTOPC or equvalent Bajaj/Chrompton /wipro / Philips
Taking out and refixing existing LED bolard light and Supply & fix in replacement of UNSV electronic driver assembly the same as exixting for bolard light fitting of 5 to 10 Watts all as specified and directed
S&F in repairs battery for LED Solar street light fitting suitable for 25 Watt with high efficiency ,lithium ferro phosphate battery with in built ,all as fixing as existing light complete all as specified and directed .make Havells/ bajaj/philips or equivalent
Supply and fixing in repair bollard light provided uniform illumination for pathways LED type 9 watt 230 watt volts AC outdoor type with decorativepost for 360 degree indirect light IP 65 protectionwith impact and corrosion resistant complete withdriver and lamp including taking down old one complete complete.make havells/ Bajaj/Chrompton
Taking down of ceiling fan 1200/1400 mm sweep from existing position/hook,dismantling blades deposite to store and removing fan cleaning, servicing or re-fixing on same position after complete all as specified and directed.
De-assembling (opening) of the ceiling fan, 1200mm/1400mm sweep for repair, removing existing burnt winding, rewinding as per existing winding the same gauge and weight with super enameled copper winding wire of appropriate gauge, slot insulation, heat varnishing, greasing and re-assembling including replacement of split pin and flexible twisted copper cable of 23/0.0076 gauge, testing complete all as specified and directed. Note:- (i) Contractor shall collect the Ceiling fan for repair from Store Yard/site of AGE E/M and fix the repaired fan on the location given by Engineer-in-charge. (ii) Where ever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
Supply only capacitor of 2.5 Mfd suitable for 1200/1400 mm sweep ceiling fan.
Supply only ball bearing suitable for 1200mm/1400mm sweep ceiling fan.
Supply only gun metal bush suitable for 1200/1400mm sweep ceiling fan of appropriate make.
S & F, in repair, capacitor of 2.5 Mfd suitable for 1200 mm/1400mm sweep ceiling fan.
S&F, in repair, PVC canopy set (Upper & Lower) suitable for ceiling fans complete all as specified and directed.
S & F in repair,ceiling fan down round metal rod/pipe of lenghts of one feet suitable for 1200 mm/1400mm sweep ceiling fan.
S&F, in repair, MS hanging clamp with rubber bush, bolts, nuts & washer with split pin suitable for ceiling fan complete all as specified and directed.
M & L Painting of ceiling fans complete, in situ with synthetic enamel paint by sprayingincluding filling cavities with filler, onecoat after cleaning/removing existing paint and all dust etc.
Taking down exhaust fan metal body of size 200/230/250/300/380/450 mm sweep from existing position, cleaning, servicing and re-fixing on same position complete all as specified and directed by Engg-in-charge.
De-assembling (Opening) of exhaust fan 200/230/250/300 mm sweep for repair, removing existing burnt winding, rewinding as per existing winding gauge & weight with super enameled copper winding wire of approprite gauge, slot insulation heat varnishing, greasing, re-assembling, refixing, testing complete all as specified and directed. Note:- (i) Contractor shall collect the exhaust fan for repair from Store/Site Yard of AGE E/M and Refix repaired fan on the location given by Engineer-in-charge. (ii) Where ever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
De-assembling (Opening) of exhaust fan 380/ 450 mm sweep for repair, removing existing burnt winding, rewinding as per existing winding gauge & weight with super enameled copper winding wire of approprite gauge, slot insulation heat varnishing, greasing, re-assembling, refixing, testing complete all as specified and directed. Note:- (i) Contractor shall collect the exhaust fan for repair from Store/Site Yard of AGE E/M and Refix repaired fan on the location given by Engineer-in-charge. (ii) Where ever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
Supply only capacitor of 4.0 Mfd suitable for exhaust fan complete all as specified and directed..
Supply only ball bearing suitable for 200/230/250/300mm sweep exhaust fan complete complete all as specified and directed..
Supply only ball bearing suitable for 380/450 mm sweep exhaust fan complete complete all as specified and directed..
Supply only gun metal bush suitable for 200/230/250/300mm sweep exhaust fan complete all as specified and directed complete all as specified and directed..
Supply only gun metal bush suitable for 380/450mm sweep exhaust fan complete all as specified and directed.
M&L for preparation of surfaces of exhaust fan of size 200/230/250/300/380/450mm including blade, frame/louver and apply one coat of synthetic enamel paint with spraying after taking down in respective items all as specified and directed by Engg-in-change.
Taking down/Disconnecting carefully water storage type water heater of 25/50 ltr cap of any make, disconnecting electric connection and dismantling for repair by taking out the syphon assembly of thermostat, heating element and cleaning, de-scaling the inner tank by chemical compound including soldering, brazing if required, Re-assembling and re-fixing the geyser after cleaning & servicing at existing position/location complete all as specified and directed. Note:- (i) Heating element, thermostat, air release valve, safty valve, indicating lamp and syphone assembly shall be measured and paid under relevant items as "Supply Only". (ii) The rate quoted are deemed to include cost of soldering/brazing work if required at site.
S&F, in repair, heating element of 1.5 KW with circular or triangular base suitable for existing entry of geysers complete all as specified and directed.
S&F, in repair, heating element of 2.0 KW with circular or triangular base suitable for existing entry of geysers complete all as specified and directed.
S&F, in repair, thermostat assembly for geyser, tempetrature setting up to 85 degree centigrade, ISI marked complete all as specified and directed.
S&F, in repair, indicating lamp suitable for existing entry of geyser complete all as specified and directed.
S&F, in repair, inlet/outlet (cold& hot) pipe of 15mm bore 400mm long, PVC connection, high density suitable for temperature upto 100 degree complete all as specified and directed.
S&F, in repair, inlet/outlet (hot & cold) pipe of 15mm bore 600mm long, PVC connection, high density suitable for temperature upto 100 degree complete all as specified and directed.
S&F, in repair, water storage type copper inner tank of 25 ltr capacity as per existing tank complete all as specified and directed.
S&F, in repair, water storage type copper inner tank of 50 ltr capacity as per existing tank complete all as specified and directed.
S&F, in repair, water storage type steel body outer tank of 25 ltr capacity as per existing tank complete all as specified and directed.
S&F, in repair, water storage type steel body outer tank of 50 ltr capacity as per existing tank complete all as specified and directed.
S&F, in repair, semi circular bottom cover plate of 25/50 ltr capacity geyser duly painted of appropriate make complete all as specified and directed.
S&F, in repair, Geyser syphon assembly (flange) made out of copper/steel as existing including heat resistance and leak proof gasket suitble for 25/50 ltrs capacity geyser all as specified and directed.
S&F, in repair,safty relief valve, as per existing of 25/50 ltr capacity geyser complete all as specified and directed.
S&F, in repair,pressure safty valve, as per existing of 25/50 ltr capacity geyser complete all as specified and directed.
S&F, in repair, glass wool superior quality around the water container as heat resistance upto full capacity complete all as specified and directed.
Taking down and Refixing up carefully 1.5 ton window OR 1.5/2 ton split type AC after checking of electric wiring and parts , cleaning of unit, lubrication of motor, capillary, filter & servicing at existing position/location complete all as specified and directed. Note:- (i) Compressor, capacitor, starting relay, overload protection shall be separetely measured and paid. (ii) The rate quoted are deemed to include cost of soldering/brazing work if required at site.
S&F, in repair, Indoor unit AC Swing blades motor in (replaced with original company of same make as per existing), suitable for working on single phase, 50 HZ AC , 1.5/2 Ton split type AC with electric connection, testing complete all as specified and directed.
S&F, in repair, Indoor unit AC BLOWER FAN motor (replaced with original company of same make as per existing), suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton type split AC with electric connection, testing complete all as specified and directed.
S&F, in repair, Indoor unit AC BLOWER FAN BUSH (replaced with original company of same make as per existing), suitable for working on single phase, 50 HZ AC supply in split type AC with electric connection, testing complete all as specified and directed.
S&F, in repair, Indoor unit AC Cooling condenser (replaced with original/as per existing), suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton split type AC with electric connection, testing complete all as specified and directed.
S&F, in repair, Indoor unit AC Display unit (replaced with original/as per existing), suitable for working on single phase, 50 HZ AC supply 1.5/2 Ton split type AC with electric connection, testing complete all as specified and directed.
S&F, in repair, Remote with PCB Circuit of 1.5/2 Ton capacity split ACs (replaced with as per existing), suitable for working on single phase, 50 HZ AC supply in split type AC with electric connection, testing complete all as specified and directed.
S&F, in repair, Outdoor unit AC Fan motor blade of suitable size (replaced with original/as per existing), suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, Outdoor unit AC copper coils of suitable size (replaced with original/as per existing), suitable for working on single phase, 50 HZ AC supply , 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, Outdoor unit AC insulation tubing/cover as per existing tubing tickness of 6 feet lenght For 1/4" & 1/2" size of copper coils(replaced with original/as per existing), suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, Outdoor unit condenser fan motor of suitable size (replaced with original company of same make/as per existing), suitable for working on single phase, 50 HZ AC supply 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, Outdoor unit AC heat condenser coil of suitable size (replaced with original company of same make/as per existing), suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity type split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company, new compressor of same make as per existing) suitable for Operation on single phase, 50 HZ AC supply for 1.5 ton split type AC including making necessary refrigerent pipe connection, electric connection, checking of leakage and testing complete all as specified and directed.
S&F, in repair, Outdoor unit AC Compressor capacitor of suitable capacity (replaced with original company of same make/as per existing), suitable for working on single phase, 50 HZ AC supply 1.5/2ton split type AC with electric connection, testing complete all as specified and directed.
M&L, in repair, Outdoor unit AC Gas valves of suitable size (replaced with original company of same make/as per existing),For 1.5/2 Ton split type AC with all conecting accessories, testing complete all as specified and directed.
S&F, in repair, Outdoor unit AC power relay contactors of suitable capacity (replaced with original company of same make/as per existing), suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton split type AC with electric connection, testing complete all as specified and directed.
M&L for refrigerent charging with R 22/R 134/R 410 for window AC of capacity 1.5 Ton and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
M&L for refrigerent charging with R 22/R 134/R 410 for split type AC of capacity 1.5 & 2 Ton and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company, new compressor of same make as per existing) suitable for Operation on single phase, 50 HZ AC supply for 2 ton split type AC including making necessary refrigerent pipe connection, electric connection, checking of leakage and testing complete all as specified and directed.
S&F,in repair, Starting capacitor of 80-100 MFD capacity for 1.5 ton window/1.5/2 ton split type AC suitable operation on 230 Volt, 50 Hz complete all as specified and directed.
S&F,in repair, Starting capacitor of 100-120 MFD capacity for 1.5/2 ton split type AC suitable operation on 230 Volt, 50 Hz complete all as specified and directed.
S&F,in repair, Running capacitor of 36 MFD capacity for 1.5/2 ton split type AC suitable operation on 230 Volt, 50 Hz complete all as specified and directed.
S&F,in repair, Running capacitor of 45 MFD capacity for 1.5 Ton window/split type AC suitable operation on 230 Volt, 50 Hz complete all as specified and directed.
S&F,in repair, Running capacitor of 60 MFD capacity for window/split type AC suitable operation on 230 Volt, 50 Hz complete all as specified and directed.
S&F,in repair, Heavy duty ODU(outdoor unit) Stand/installation bracket kit with brackets, fasteners, nuts and washer for 1.5/2 ton split type AC complete all as specified and directed.
M&L, in repair, starting relay of window/Split type A/C, 1.5 to 2 Ton capacity including making necessary electric connections complete all as specified and directed.
M&L, in repair, Thermostate switch suitable for window/Split type A/C, 1.5 to 2 Ton capacity including making necessary electric connections complete all as specified and directed.
M&L, in repair, Sensors for all model type AC.s, including making necessary electric connections complete all as specified and directed.
S&F, in repair, overload protector for split type AC of 1.5/2 Ton capacity complete all as specified and directed.
M&L, in repair, copper piping of 1/2" & 1/4" size , wiring between Indoor & Outdoor for 1.5/2 ton split type AC including all necessary connecting accesssories complete all as specified and directed.
S&F, in repair, indoor unit DC MOTOR (replaced with original company of same make/as per existing), OF suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity INVERTER Type Split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, DC INDOOR CIRCUIT (replaced with original company of same make/as per existing), Of suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity INVERTER Type Split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair,INVERTER OUTDOOR CIRCUIT (replaced with original company of same make/as per existing), Of suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity INVERTER Type Split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, INVERTER OUTDOOR UNIT DC COMPRESSOR (replaced with original company of same make/as per existing), Of suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity INVERTER Type Split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, INVERTER OUTDOOR UNIT SENSOR (replaced with original company of same make/as per existing), Of suitable for working on single phase, 50 HZ AC supply, 1.5/2 Ton capacity INVERTER Type Split ACs with electric connection, testing complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in refrigerator 1/8 HP (165 to 210 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in refrigerator 1/6 HP (265 to 310 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair,Evaporator of 165/180L Capacity (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in refrigerator 1/8 & 1/6 HP (180 to 310 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 200 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 310/320 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
M&L, in repair, starting relay of Refrigerator 1/8 to 1/6 HP capacity including making necessary electric connections complete all as specified and directed.
S&F, in repair, overload protector of Refrigerator and Deep freezer 165 Ltr to 320 Ltr complete all as specified and directed.
S&F, in repair, Deep freezer condenser (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 200/310/320 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, Deep freezer condenser fan motor (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 200/310/320 Ltrs capacity including making connection, electric connections and testing complete all as specified and directed.
S&F, in repair, Deep freezer cooling fan of 35x35x10mm (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 200/310/320 Ltrs capacity including making connection, electric connections and testing complete all as specified and directed.
M&L for refrigerent charging with R-134a for Deep Freezer of capacity 200 Ltr to 320 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
M&L for refrigerent charging with R-600a for Refrigerator of capacity 165 Ltr to 320 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in water cooler of 40/80 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
M&L, in repair, starting relay of water coolers 40/80 Ltr capacity including making necessary electric connections complete all as specified and directed.
S&F, in repair, overload protector of water cooler up to 120/150 Ltr complete all as specified and directed.
M&L for refrigerent charging with R-22/R-134 for Water Cooler of capacity 40/80 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
M&L, in repair, Thermostate suitable for water cooler up to 120 ltrs capacity including making necessary electric connections complete all as specified and directed.
M&L, in repair, Thermostate suitable for Refrigerator & deef freezer up to 320 ltrs capacity including making necessary electric connections complete all as specified and directed.
S&F, in repair, Running capacitor, 230 Volts, SP, 4.0 MFD complete all as specified and directed.
S&F, in repair, Running capacitor, 230 Volts, SP, 6.3 MFD complete all as specified and directed.
S&F, in repair, Running capacitor, 230 Volts, SP, 36/45 MFD complete all as specified and directed.
S&F, in repairs, water lift submerssible pump (ISI Marked) suitable to operate on 230V AC supply of desert cooler and connecting electically, complete all as specified and directed.
S&F, in repair, fan motor (ISI Marked), 1/6 HP, 230 volt single phase of existing desert cooler with fixing clamps, complete all as specified and directed
S&F, in repair, wood wool pads, superior quality, size 60x45 cm (approximate), complete all as specified and directed
S&F, in repair, PVC insulated and PVC sheathed cable 3 core, 2.5 Sqmm, multistandard copper conductors for water coolers/ refrigerators complete all as specified and directed.
SURESH ELECTRICALS
Ramdev and Sons
Vardaini Industries
Marudhar construction company
Shree Builders
K K Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .