Chief Engineer (ESG)
3rd Floor, North Wing DCSEM, DAE, V.S. Bhavan, Anushaktinagar, Mumbai-94
Providing additional Electrical, air conditioning and allied civil works for UGC-DAE building at VECC, Rajarhat , Kolkata.
2024_DCSEM_809307_1
DCSEM/CQD/QS-C/VECC/ UGC-DAE/Elect /24-25/NIT-08, Dt.29/05/2024
Open Tender
Electrical Works
Item Rate
120 days
VECC, Rajarhat, Kolkata.
Please refer Tender documents
8 documents required · 8 mandatory
₹0
₹1.8 L
2 Aug 2024
31 May 2024
3 Jul 2024
31 May 2024
1 Jul 2024
13 Jun 2024
31 May 2024 - 12 Jun 2024
Amount
Section
SECTION - I :LT Cables and End Joints
SECTION - II : Readymade DB
SECTION - III : Point wiring & Submain wiring
SECTION - IV : Earthing System
SECTION - V : Telephone system
SECTION - VI : LAN system
SECTION - VII : Fire alarm system
SECTION - VIII : LED Luminaire etc
SECTION - IX : Miscellaneous Items
SECTION - X : Civil work
Description of Work / Item(s)
Amount
CABLE TRAYS AND CABLE MANAGEMENT SYSTEM : Supplying and fixing following sizes of GI wire mesh tray,hot dipped galvanised between 60 and 80 microns of zinc as per BS 729 carbon Steel cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required, and duly suspended from the ceiling with electro-zinc coated TF rods, wall mounting brackets etc.
150mm width x 50 mm depth
Cable tray cover only for existing 300mm width Cable tray
Cable tray cover only for existing 150mm width Cable tray
MS Fabrication : Supply, fabrication and installation of supports using MS channel/angle / flat/ MS rod hangers etc.including cutting, fabrication, welding etc. and painting with two coats of primer and two coats of enamel/ PU paint of approved shade as per instructions of EIC.
Blank PVC (HMS) Conduits : Supply & installation of high mechanical stress (HMS)rigid PVC conduit having ISI marked IS 9537 Part - 3,including fixing accessories & hardware concealed/exposed in slab/wall or on 5mm. thick G.I. spacers fixedwith no. 10 nettle fold wood screws with nylon plug complete with all conduit accessories 20 SWG G.I.Saddles, MS/PVC pull out boxes, MS/PVC junction boxes,couplers, bends binding wires etc. as per site condition & as per instructions of E-I-C and of following sizes :-
32 mm dia
PVC trunking system : Supply, installation, testing & commissioning of PVC trunking/casing capping with flexible cover of following sizes of M/s Legrand make, suitable for mounting on wall as per instructions of EIC. Note: All the accessories like Internal, Flat & external angles,VDI accessories for internal, Flat & external angles, end caps, joint covers, cable tie base etc. suitable for PVC trunking shall be included in the scope of work.
25 x 16 mm PVC casing capping with flexible cover
80 x 50mm PVC trunking with flexible cover
150 x 50mm PVC trunking with flexible cover
Disconnection of existing Incoming cable & Shifting of existing MDB G.4 from chemistry lab to workshop and retermination of Incming LT cable in panel incomer etc.
Supply and erection of min 30 feet titable tower extension industrial use ,4 wheels, min100kg capacity Aluminium ladder etc complete as per instruction of engineer in charge.
Supply, installation, testing and commisioning (SITC) of semi electric staker of capacity 1000-2000kg with lift height upto 3.5 m similar to model no E124SE of M/s easy move or equivalent as per instructions of EIC.
Split Air-conditioner: Supply, installation, testing and commisioning (SITC) of wall mounted 5 star rated Invertor hi-wall Split AC unit of 1.8 TR / 6.2 Kw nominal/rated cooling capacities working on R-32 or CFC or HCFC free refrigerant suitable for Single phase, 50 Hz, 230 V AC power supply. The unit shall be suitable for maximum piping length of 25 meter and maximum height between units of 20 meter. Note: 1. The rate is inclusive of refrigerant piping (gas and liquid both) upto 25 meter. 2.The outdoor unit shall be provided with 10 mm thick neoprene pads. 3.The price is inclusive of consumables, leak testing, refrigent gas that may be required to put the air conditioner into service and no extra payment shall be made for the same. 4.The cutout for regrigerant pipe cable and drain shall be included in scope and no extra payment shall be made for the same. 5. On site warranty of Compresser shall be min. 10 years and PCB shall be min. 5 year from date of supply of units. Warranty certificates shall be submitted for each units while supplying the units.
Description of Work / Item(s)
Amount
Providing and laying autoclaved aerated cement (AAC) blocks masonry with 100mm thick AAC blocks as per approved manufacturer, using approved block laying polymer modified adhesive mortar in super structure above plinth level at required locations, levels complete all as per specifications and as directed by Engineer in-Charge. AAC blocks shall be conforming to IS:2185, Part-3, having Grade-I with block of density 551 to 650 Kg/cum) .
Cement concrete of specified grades at all locations & depths for the following works using graded stone aggregate of 20mm maximum size including necessary formwork, machine mixing, transporting, placing in position consolidation, finishing, curing etc. complete as per specifications, drawings & as directed by the Engineer in charge.
PCC of grade 1:2:4 in form of packing of size 100mm wide & 100mm thick.
Providing & fixing of stainless stell (Grade SS 304 fabricated out of 24 gauge sheet )letters in suitable font having compatible width in english and hindi languages as mentioned of appropirate size (8" Hindi & English (tolerance +-0.5 " ), 3/4" rising with approved design ,patterns,machine cut/mould ,mirror polished , duly fixed on A.C.P. Board throughout the M.S. flat framework on canopy wall (Size 22'×29'') including 2 nos LED logo (Size 29''×29'') with necessary SS screw as per requirment and welding to best workmanship, providing sufficient stiffeners to increase rigidity and making arrangment for necessary fixtures by drilling holes providing proper drilling for fixing LED light as per sample on back side of steel letters for proper lighting arrangment including necessary electrical connection from stairside point to steel letters board with proper size wires through MCB and internal wiring. All complete at all height and levels including labour, tools & tackles, scaffolding etc. Complete in all resepect as per instruction of EIC. Note: Sample shall be approved by department before fabrication.
Providing and Fixing rectangular glow sign board (16'×4') with 2 nos logo in traingular format including logo of National Emblem & UGC using solvent digital printing/colour vinaly application over 1.5mm thick Polycarbonate sheet of M/s lexan/Gallina India or apporved equivalent conforming to IS-14443:1997 /latest ammnedment at front and 26 SWG GI sheet at back and alround to form a box made out of MS square tube (25×25×1.0 mm thick) duly welded, fixing aluminium angle(20×20×0.5mm thick) at front edge around with necessary SS screw along with making provision for providing suitable structural framework made with M S angle (65×65×6mm thick) framework should be 2 nos post approx Length 10' long & frame 16'×4' with intermidiate MS members fixing on grond with cement concrete as required including fixing entire framework with existing MS structure providing and fixing 20W LED tube light for 16'×4' glow sign board as required levels including cost of all mterials , labour,tools, tackles, scaffolding necessary electrical connection from staircase switchboard to glow sign board through MCbB with proper size wire,cable with pipe protection as required coplete in all resepect as per instruction of EIC. Note: Sample shall be approved by department before fabrication.
Providing & applying acrylic emulsion (plastic) paint for internal plastered surfaces in two or more coats on old surfaces at all floors, levels & location using ready mixed & ready made acrylic emulsion paint of approved make and shade including one coat of approved cement / acrylic primer (water thinnable) including labour, material, scaffolding, surface preparation, cleaning etc complete all as per specifications and as directed by Engineer-in-Charge. (Note:- Acrylic emulsion shall have VOC content less than 50 grams/ litre)
On Old Surfaces (Including thoroughly scrapping, removal of old paint, if any, sand papering & preparing the surfaces, applying approved putty for touch up to fill up crevices mild depression etc, necessary covering material (tarpaulin etc), cleaning, removal of splashing & droppings of floors, wall, ceiling, doors & windows etc & disposing of debris at outside the campus.)
Description of Work / Item(s)
Amount
L.T Cables: Supply, installation, testing & commissioning of 1.1 KVgrade aluminium/ Cu stranded circular/ sector shape core conductor with XLPE insulation, extruded PVC inner sheathed, G.I flat strip/wire armoured, extruded FRLS grade antirodent & anti termite PVC (ST-2)outer sheathed cable conforming to IS : 1554 Part I / IS 7098 Part-I with latest amendments, fixed on wall/column/slab/ false ceiling / existing cable tray /existing hume pipe/trench/shaft/pit/ on 5mm thick M.S. flat /GI spacer/angle/support fixed with coach screws/grouted in wall/anchor fasteners 2mm. thick G.I. fabricated saddle, all fixing accessories, etc complete including painting of M.S spacers/angles and saddles or in ground , sand bedding,laying of baked bricks on side & top-, temporary reinstatement, back filling, dewatering, consolidation,disposal of excess earth within the radius of 500 m and making good to the original finish etc providing Al cable tag as per enclosed detailed specifications, drawings & asper instructions of the E-I-C & of the following sizes. NOTE: 1) Excavation of earth shall be measured under Miscellaneous item. 2) Sealing of hume pipes with wooden bushes aftercable laying shall be included in the scope of work 3) Clamping of cables on trays including supply of clamping materials as per instruction of EIC shall beincluded in the scope of work. 4). Scope of works also include cutting, filling the leftover gaps with cement mortar , bricks etc and finishing by applying white cement and touch up paint of affected area by roller /brush etc as per instruction of EIC.
3.5C x 185 Sq.mm Al. conductor cable
3.5C x 50 Sq.mm Al. conductor cable
4C x 25 Sq.mm Al. conductor cable
4C x 10 Sq.mm Al conductor cable
3C x 2.5 sqmm Cu Conductor cable
LT Cables End Joints: End jointing of following sizes of cable by crimping with supply of all jointing materials like solderless tinnedcopper cable socket,double compression brass cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminals as per the drawings,specifications and as per the instructions of the Engineer-in-charge.
3.5C x 185 Sq.mm Al. conductor cable
3.5C x 50 Sq.mm Al. conductor cable
4C x 25 Sq.mm Al. conductor cable
4C x 10 Sq.mm Al conductor cable
3C x 2.5 sqmm Cu Conductor cable
Description of Work / Item(s)
Amount
Supply, installation, testing & commissioning of following readymade distribution boards, double door, IP 42 degree protection complete with necessary, MCB isolators , MCBs,earth leakage circuit breaker (ELCB) etc including interconnections with appropriate capacity size of PVC insulated copper conductor wires (ISI marked),suitable for concealed mounting /wall mounting with MS frame workof 40 x 40 x 5 mm MS angle iron, with M.S. enclosure fabricated out of min 18 SWG /20 SWG thick M.S. CRCA sheet as per manufacturers standard, with concealed hinged door, locking arrangement etc. including earthing clamps for both incoming & outgoing circuits,interconnections, per phase isolation kit as required,cable end box & wire way box if required, continuous copper earth wire in the wire way box with single/duplicate brass earthing terminals, danger board, name plate, flexible earthing for the door, metal treatment & powder coatedpainting, Phase Distribution drawing etc. all as per drawings (G.A. & fabrication drawing to be got approved), Note: 1.MCBs (Type –C) shall be minimum 10 KA breaking capacity, as specified. 2. Blanking Plates shall be included in scope of work. 3. DB shall be of standard readymade type from approved manufacturers as indicated in preferred makes of material.
VTPN MDB : a) 250 A , FP MCCB - 1 No. b) 63/40 A ,TP MCB -12 Nos. c) 12 way brass neutral link - 2 set
ETPN DB : a) 63A FP MCB - 1 No. b) 63A DP ELCB with 30mA sensitivity - 3 nos c) 6-32A SP MCB - 24 nos d) 8 way brass neutral link - 4 set
ETPN DB : a) 63A FP MCB - 1 No. b) 63A DP ELCB with 30mA sensitivity - 3 nos c) 6-32A SP MCB - 18 nos d) 8 way brass neutral link - 4 set
MCCB/ MCB enclosure: Supply, Installation, Testing & Commissioning of following MCCB/ MCB with suitable enclosure withangle iron framework including minor civil works to fix on the wall etc complete and all ncessary
125A, 25 kA FP MCCB with Thermal magnetic release
32/63A, 10kA FP MCB
Description of Work / Item(s)
Amount
Point wiring in PVC (HMS variety) conduits : Point wiring for light/ceiing fan/6A/ 16A/ socket outlet/6A outlet for exhaust fan , bell point etc. with 1.1 KV grade FRLS PVC insulated multistranded copper conductor wire (ISI marked), in existing floor raceway/Existing PVC truncking/ 25 to 40 mm dia High mechanical stress (HMS) rigid PVC conduit/casing caping having ISI marked IS 9537 Part - 3, including fixing accessories & hardware concealed /exposed in slab/wall or on 5mm.thick G.I. spacers fixed with no. 10 nettle fold wood screws with nylon plug complete with all conduit accessories 0.9mm G.I. Saddles, ready made MS switch boxes & socket outlet boxes of nominal 1.2 mm thickness , brass earthing stud 1/2 nos, controlling modular switches, sockets with moulded front plate and inner plate etc. including appropriate size of FRLS PVC insulated copper earth wire ,brass/bakelite (straight / angular) lamp holders, 3 plate ceiling rose,6 A, connectors, painting etc. as per specifications and drawings and as per instructions of E-I-C and as detailed below : (sample switch Box etc. to begot approved before fabrication). NOTE: 1. Connections shall be done with crimped type tinned copper lugs & washers. 2. All switches & socket outlets shall be as per preferred makes. 3. All sample boxes with accessories /luminaires shall be got approved from Department. 4. MS boxes other than switch boxes & socket outlet boxes shall be fabricated out of minimum 1.5mm thick MS sheet duly painted with red oxide primer & 2 coats of epoxy paint. 5. Minimum size of the FRLS insulated copper earth continuity wire shall be 2.5 sq.mm. 6. The colour shade of switches shall be white /off white. For socket outlet points/switch boards on normal power supply, the cover plate shall be white/off white colour, graphite grey (RAL 7024) or other shade as per instruction of EIC, for socket outlet points/switch boards on DG power supply. 7. The scope also includes supply of modular blanking plates where ever required. 8. The maximum permissible number of FRLS insulated wires through PVC/MS conduits shall be as per technical . 9. PVC truncking shall be measured separately under relevant item. 10. Scope of works also include cutting, filling the leftover gaps with cement mortar , bricks etc and finishing by applying white cement and touch up paint of affected area by roller /brush etc as per instruction of EIC.
Primary Light point with 2 nos. 1.5 sq.mm wires & 1 No. 2.5 sqmm earth wire with 6A switch
Secondary light point with 2 nos of 1.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire looped to above item 1.01/existing Primary point.
6A socket point with 2 nos of 1.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wires & 6A switch on switchboard.
2 nos.6A socket points with 2 nos of 2.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wires, looping with 1.5 sqmm + 2.5 sqmm wires (for earth) & independent 6A switches.
3 nos.6A socket points with 2 nos of 2.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wires, looping with 1.5 sqmm + 2.5 sqmm wires (for earth) & independent 6A switches.
4 nos.6A socket points with 2 nos of 2.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wires, looping with 1.5 sqmm + 2.5 sqmm wires (for earth) & independent 6A switches.
16 A 6 pin socket outlet point with 2.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire complete with 16 A switch in one box.
2 nos 16 A 6 pin socket outlet point with 2.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire looping with 2.5 sq.mm wires complete with 16 A independent switches.
3 nos 16 A 6 pin socket outlet point with 4 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire looping with 2.5 sq.mm wires complete with 16 A independent switches
4 nos 16 A 6 pin socket outlet point with 4 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire looping with 2.5 sq.mm wires complete with 16 A independent switches
6 A + 16 A (6 pin) socket outlet point with 2.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire & loopingwith 1.5 sqmm + 2.5 sqmm wires complete withindependent 6A and 16 A SP switches in one box.
Point wiring for single phase exhaust fan with 1.5 sq.mm phase wires & 2.5 sqmm earth wire & with ceiling rose near exhaust fan & controlling 6 A , 240 V SP switch on nearest switchboard.
Point wiring with 4 sq.mm wire and 2.5 sq.mm insulated earth wire complete with 25 A 3pin socket outlet with plug(Industrial Type) near split AC unit & 25A DP MCB at operating height on wall, in readymade powder coated MS CRCA box with MS cover and with necessary cutouts,interconnections earthing stud etc . MCB shall be with 10KA breaking capacity.
Point wiring with 4 sq.mm wire and 2.5 sq.mm insulated earth wire complete with 32 A 3pin socket outlet with plug(Industrial Type) & 32A DP MCB on wall, in readymade powder coated MS CRCA box with MS cover and with necessary cutouts, interconnections earthing stud etc .MCB shall be with 10 KA breaking capacity.
6A socket point on the wall/ceiling with 2 nos of 1.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wires & directly controlled from DB (For emergency lights on battery backup)
Submain Wiring : Supply, installation testing & commissioning of 1100 VFRLS grade PVC insulated multistranded aluminium conductor wires of the following sizes with necessary lead sat both sides in 25mm/ 32mm/ mm/40mm dia PVC(HMS)or MS conduit concealed in wall/beam/ slab/column or onsurface of wall/beam/slab/ column on 5 mm thick G.Ispacer and 20 SWG GI saddle, MS pull out boxes , junction boxes of suitable sizes as per site requirement, from MDB to individual DB including connection with copper lugs etcas per specifications and as per the instruction of Engineer-in-charge. Note: 1. Connections shall be done with crimped type tinned copper lugs. 2. All embeded conduit junction boxes/pull boxes shall be covered by 18 SWG thick M S sheet covers painted white projecting atleast 5 mm around finished opening fixed tobox with CSK machine screws.
2 nos. of 6 sq.mm & 1 no. of 4 sq mm copper wire in 40 mm dia PVC (HMS variety) or MS conduit with necessary pull out boxes, junction boxes etc including end temination at both the ends with additional loop wire of 0.5 m length at either ends.
Description of Work / Item(s)
Amount
Supply,installation,testing & commissioning of maintenance free earthing system & associated works, etc.complete as per specifications & instructions of E-I-C. NOTE:1) Measurement of Earth resistance must be carried out as per instructions of EIC.
Tinned Cu. earth plate electrode 600 X600 X 3 mm earth station 2.5 m below ground level conforming to IS 3043 & as per drawing No. CED/E&M/STD/12 complete with all required materials like coke /charcoal, salt, brass nut-bolt & washers, watering arrangement, G.I. Pipe (B class) concrete chamber, 10 mm thick chequered plate hinged cover mounted on 40x40x5 mm thick angle iron frame & excavation in all types of soil in ground refilling & removal of excess earth within radius of 500 m. etc. NOTE: 1) The chamber cover & frame shall be hinged type & it shall be got approved by department.
G.I / tinned Cu earth wire/earth strip fixed on wall/side of trench/slab /column /beam/ shaft connection to panel/DBs/SFU's etc. with 5mm thick G.I. Spacers & 2mm thick G.I. Saddle or in ground at 500 mm below with earth enhancing material surrounding the strip, including excavation in ground, refilling & removal of excess earth within a radius of 500 m, temporary instatement & backfilling of trench, consolidation, painting with two coats of black bituminous paint for earth wire/ strip in ground & green enamel paint for earth wire /strip on surface etc.
25 X 6 mm tinned copper strip
8 SWG tinned Cu earth wire
Description of Work / Item(s)
Amount
Telephone Point Wiring: Point wiring with 4 pair CAT-6 wires copper conductor PVC insulated, in 25-40 mm dia rigid PVC conduit (HMS variety - ISI marked,conforming toIS 9537 Part-III) concealed in slab /wall or surface with 5mm thick G.I.spacer & 20 SWG GI Saddle fixed with nylon plug, wood screws etc. complete with all conduit accessories suitable MS pull boxes of suitable sizes as persite condition wherever required M.S. telephone point accessories boxes fabricated out of min 18 SWG/20 SWGthick CRCA sheet zinc passivated , brass earthing studs 1/2 nos., RJ-11 telephone socket outlets with shutter ferrule numbers on both side of the circuits all terminations with ferrule /lugs if required, labelling all as per drawing specifications & as per instructions of E-I-C. NOTE: 1. Point wiring means 4 pair CAT-6 wires from TelephoneTag Block to assigned point including end termination ofone pair at both sides and other pairs should be keptspare. 2. G.A drawings & fabrications drawing are to be got approved from E-I.C.
Point wiring for telephone point with 4 pair CAT-6 wire with RJ 11 jack type socket with shutter in a box with connector
Description of Work / Item(s)
Amount
LAN System : Supply, instalaltion, testing & commissioning of local area network system comprising of passive components like CAT-6 UTP or improved data cable, information oulet with RJ-45 connections , enclsoures for data outlets with faceplates concealed, patch panels, cable managers, LIU, OFC,splicing, 19" mounting racks , power panels in racks ,cooling fans in racks, flexible G.I pipe, PVC conduit HMS variety conforming to IS 9537 Part-III etc., complete with labeling/identification on the cable , outlets, patch panels etc. complete in all respect as required as per standards,drawings, specifications and instructions of E-I-C. Note : 1. LAN work shall be done by a specialised agency in the field. Credentials of the agency through which the bidder proposes to execute the LAN work to be submitted post W.O. 2. Evaluation of the proposed agency to execute the LAN work shall be carried out seperately by the Department. 3. Active components i.e switches etc are not in the scope of the agency and shall be executed by the users seperately. Agency shall extend full co-operation to theagency / users executing the balance work which is not inthe scope of this tender. 4. Scope includes termination of cables at both ends with all accessories and installation/mounting of 19" racks with all accessories like angle iron frame work etc without any extra cost to the Department. 5. All LAN passive components shall be of same make.
Point Wiring : Point wiring in MS/PVC conduit HMS variety of size 25-40 mm dia ISI mark concealed in slab/column/beam/surface wherever required complete with bends, T/ Cross, junction box with all accessories with RJ-45 shuttered socket outlets (modular) concealed / surface in wall/column/wherever required with all accessories including label holder, face plate, factory made zinc passivated box, screws etc terminated at one end at patch panel at respective floor at the other end in outlet with an extra loop length of approx 2 m at patch panel, ferrule numbers on both side,all terminations as per standards, drawing, specificationsand as per instructions of E-I-C Note : 1. Colour of the outlet and facia plate shall be matching with electrical switches and sockets with the approval of E-I-C.
Description of Work / Item(s)
Amount
Fire Alarm system (FAS) Design,supply,installation,testing & commissioning of analogue addressable type fire alarm system as per relevant Indian Standard specifications and conforming with relevant specifications of fire authorities of local Municipal Corporation, and as directed by E-I-C and consisting of the following: Note. 1) The work shall be carried out by licensed agency complying local State Fire safety statutes. 2)Scope includes submission of factory test report of FAS components. 3)Make of all the components of FAS shall be same and compatible with existing FAS. 4) FAS components shall be compatabile with existing M/s Schrack FAS.
Beam Detectors : Supply ,installation,testing & commissioning of Intelligent addressable beam detector unit detection with inbuilt fault isolator with seprate unit for transmitter and receiver complete with base as required & as per instructions of EIC.
Response Indicator : Supply ,installation,testing & commissioning of Response indicator consisting of aluminium casting enclosure & steady glowing 2 nos.red indicator (LED) and cover plate shall be screen printed as "FIRE". The unit shall be suitable for connecting in parallel to the multisensor & wall mounting type with provision of 25mm dia conduit entries ,painting & other materials as complete as per specifications & of E-I-C.
Wiring for Fire Alarm System : Wiring with 2 nos. 1.5 sqmm FRLS-PVC insulated Shielded twisted pair copper cable/wires in 25mm dia concealed/surface MS/PVC conduit (HMS variety)/casing capping including cost of cutting and filling chases for concealed conduit/ cost of saddles etc. for surface conduit/casing capping as required and including the cost of crimped termination’s as required, complete as per instructions of E-I-C.
Integration of fire damper units (7 nos) with existing FA system including CR module etc
Description of Work / Item(s)
Amount
Supply, installation, testing & commissioning of LED luminaires complete with accessories etc on surface of slab/beam by 2 nos (minimum) of 6 mm anchor fasteners or on wall with 2 nos of wood screws, nylon plug etc.,suitable supporting frame fixed with rag bolts grouted on the wall/anchor fastener on the beam/on the column & other fixing accessories etc provision & connection with 1.5 sq.mm multistranded copper conductor FRLS PVC wires etc., all as per drawing, specifications & as per the instruction of E.I.C. Notes: 1) Sample luminaire/fittings shall be got approved from Dept with complete technical data. 2) All luminairess shall be with drivers. 3) Cost of mounting accessories shall be included in luminaires cost. 4) The lumen output indicated is minimum system output of luminaire. 5) No negative tolerance is allowed on minimum system performance parameters indicated in the SOQ and specifications. 6) The CCT of the luminaire shall be decided at time of work execution.
LED Recessed Mounted min. 2000 Lumen system output Luminaire Similar to M/s Philips Cat. No. DN 295 LED10S or equivalent approved.
Emergency Luminaire :
LED surface/recess, maintained type luminaire with 1 hour backup with all required hardware, egress symbols etc as per instructions of EIC.
Klystron Electronics Pvt. Ltd.
G-TECH CONSTRUCTION & FABRICATORS
Klystron Electronics Pvt. Ltd.
Klystron Electronics Pvt. Ltd.
G-TECH CONSTRUCTION & FABRICATORS
Klystron Electronics Pvt. Ltd.
Klystron Electronics Pvt. Ltd.
Klystron Electronics Pvt. Ltd.
Klystron Electronics Pvt. Ltd.
G-TECH CONSTRUCTION & FABRICATORS
Klystron Electronics Pvt. Ltd.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .