Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance DIAMOND STREET 2ND STREET POTTAPEDU ROAD NSC BOSE NAGAR RAMAPURAM CHENNAI TAMIL NADU 600116 | THIRUVALLUR | TAMIL NADU | 600116 | Admitted-Finance |
| 4 | Admitted-Finance 004 003 SUMANGAL VIHAR COLONY NEAR LATA MANGESHKAR COLLEGE ISASANI HINGNA ROAD NAGPUR MAHARASHTRA 440016 | NAGPUR | MAHARASHTRA | 440016 | Admitted-Finance |
Tender Value
₹6 L
EMD Value
₹18,000
Closing Date
11 Mar 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
REGIONAL MANAGER
HOTEL PONDICHERRY ASHOK, EAST COAST ROAD, KALAPET, PUDUCHERRY-605014
SITC OF PANEL BOARDS AT MURUNGAPAKKAM MUSEUM IN PONDICHERRY
2022_ITDC_106209_1
PAHCL /Panel Board/SITC/2022
Open Tender
Miscellaneous Services
Works
45 days
puducherry
Please refer Tender documents.
17 documents required · 17 mandatory
₹0
₹18,000
Yes
24 Mar 2022
18 Feb 2022
12 Mar 2022
18 Feb 2022
11 Mar 2022
18 Feb 2022
120 days
Amount
Supply and installation of Cubicle floor mounted panel Board with 14G CRCA sheet, powder coated Siemens grey (RAL 7032) after seven tank process and complete with welded & bolded design and all incoming & out going switch gears as per the following:- Suitable Aluminium bus bars, control wiring , control fuses , separate metering compartment with multi function meter and phase indications. Electrical and mechanical inter lacking facility between EB incomers & bus coupler. Safety features and items including necessary earthingthrought the bottom length, 6 sq.mm FRLS copper wire connections for compartment earthing, complete copper control wiring with crimping type ferrules , copper lugs, proper engravation on each compartment etc. The switch boards shall be CPRI approval and factory assembled and tested. All complete compatible with EMS & RS 485 integration All bus bars shall be fixed with standard space clearance and with colour coated heat shrinkable PVC. Sleeves with DMC/SMC bus bar supports and suitable copper earth bus Cable entry shall be from the bottom / top as per site requirement. The item including cost of MS base from of 75mm height 3.15mm sheet steel or 40mm x40 mm x 6mm MS angle for load bearing members fittings hooks steel support structure required for irrigation and its painting , minor civil work vendor drawings necessary safety clearance from statutory authorities , panel approval from CPWD /PED till obtaining final power supply all complete as per specification drawings and / or as directed by the Engineer i) The contractor shall submit general arrangement & control wiring drawings along with CPRI test certificates and get approval from Engineer in-charge / consultant before commence the fabrication works. MAIN PANEL: i) 250A 4P on load Auto Transfer switch with ON delay Timer Auxiliary relay/ contactor, single phase preventer, control MCB,s - 01 set ii) 250A ,TPP , 36KA , MCCB with adjustable thermal magnetic releases and rotary handle mechanism & spreader – 01 No iii) Phase indication lamps (RYB) – 02 sets iv) ON/OFF/TRIP Indication lamps -01 set v) CT ratio 250/5A , CL :1.0 tape insulated bar primary type with suitable sorting links – 01 set vi) Multifunction meters cl:1.0 measured with V,A.F.PF.KW.KWH & phase sequence -01 set vii) BUS BAR:- 250A TPN,25KA for 1 sec Aluminium bus bar , Phase:- current density not more than0.8 A / sq.mm, Neutral: half of the phase current (0.5xPhase), Earth: 25 x 3 mm copper flat throught the panel length viii) OUT GOING: 125A, TPN, 25KA MCCB with adjustable thermal magnetic releases and rotary handle mechanism & spreader -02 Nos. 63A , TPN.18KA MCCB with adjustable thermal magnetic releases and rotary handle mechanism & spreader - 15 Nos
40 KVAR APFC PANEL: INCOMER:- 125A, TPN. 25KA, MCCB with adjustable thermal magnetic releases and rotary handle mechanism & spreader -01 No i) Phase indication lamps (RYB) – 01 set ii) ON/OFF/TRIP Indication lamps -01 set iii) CT ratio 125/1A , CL :1.0 burden 5VA tape insulated type with suitable sorting links – 01 set iv) Multifunction meters cl:1.0 measured with V,A.F.PF.KW.KWH -01 set OUT GOING:- Each bank provide with stage incomers and on indication lamp Micro processor based APFC relay with 8 stages, capacitor duty contactor, cylindrical gas filled and consider up to 5Kvar heavy duty type 480V i) 10KVAR with 63A TP MCB -02 Nos ii) 5KVAR with 32A TP MCB -02 Nos iii) 4KVAR with 32A TP MCB -01 No iv) 3KVAR with 32A TP MCB -01 No v) 2KVAR with 32A TP MCB -01 No vi) APFC controller with 8 stages -01 No vii) 1KVAR with 25A TP MCB -01 – Direct control
LT CT METERING PANEL Supply and erection of compartmentalized CT metering panel (3 Compartmental type) for receiving the EB supply and consisting of 250A 4 Pole copper bus bars suitable to accommodate 3 Nos CTs. The meter chamber will have provision to fix 3 phase 4 wire 50 Hz Ct operated Kwhr meter to be supplied by supply authorities and the front meter door to read the meter recording the meter door shall have provision for sealing arrangement by supply authorities .The TTB chamber will have 3 phase 4 wire 50 Hz TTB. All Chambers should have sealing arrangement provision. 3 Nos 250A porcelain cutouts and 315A Neutral link with cable chamber suitable for receiving 1 No 3 1/2 core 185 sq.mm PVC insulated Aluminum conductor armored such that should be approved by local supply authorities.
Design and supply of 250A TPN SDF DIN type fuse link with suitable sorting as complete with enclosure
Madras Power Corporation
RAHSAN ENGINEERING
Kumar Electricals Service
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .