| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.0 LAccepted-AOC VILL BHAISORA POST CHINHAT DISTT LUCKNOW UP | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹59.9 L+₹6.9 L (12.9%)Rejected-Finance 10 SUBASH COLONY DEFENCE LAB ROAD RATANDA JODHPUR 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹68.1 L+₹15.1 L (28.5%)Rejected-Finance MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹75.7 L+₹22.7 L (42.7%)Rejected-Finance PLOT NO 361 FLAT NO 06 FIRST FLOOR SECTOR 11 HIRAN MAGRI UDAIPUR 313001 RAJ | UDAIPUR | UDAIPUR | RAJASTHAN | 313001 | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹63 L
EMD Value
₹1.2 L
Closing Date
26 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010
SPL REPAIR TO BLDG NO. P-43 (SINGLE LIVING ACCN FOR NURSING OFFICERS) OF MH AT ARMY AREA JODHPUR UNDER GE (ARMY) NO. 02
2025_MES_702128_1
82425/133/E8
Open Tender
Civil Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (ARMY) NO. 02 JODHPUR
₹1.2 L
Yes
25 Jun 2025
21 Mar 2025
3 May 2025
21 Mar 2025
26 Apr 2025
12 Apr 2025
22 Mar 2025 - 11 Apr 2025
Amount
Demolition of cement concrete of any description and in any position not otherwise specifically provided for (such as copings, bands of any type, roof padding, kerbs, sunken etc; overall thickness and removing the dust debris etc to a distance not exc 250 meter from site and disposing the same complete all as specified and directed by Engr in charge.
Demolition of RCC work as in Roofs (including all fineshes, treatment, padding etc,), floors (other than ground floors), beams, stair cases, landing, chajjas and similar suspended work incl (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engr in charge.
M&L for reinforcement concrete 1:2:4 type B1 using 20 mm graded stone agg as in copings, kneelers, apex stones, bed plates, kerbs lintels upto 1.5m clear span, cills, steps; seismic and other similar bands including necessary formwork, not provided including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engr in charge.
Use and Waste of Form work to sides and soffits of floor or roof RCC beam sides of lintel beam flat rough finish surfaces to receive the plaster, complete all as specified and directed by Engr in charge.
Use and Waste of Formwork for chullah hoods, chajjas through and similar items including edges, surface rough finish surfaces to receive the plaster, complete all as specified and directed by Engr in charge.
Use and Waste of Form work to soffits of suspended slabs such as roof slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping), rough finish surfaces complete all as specified and directed by Engr in charge.
Use and Waste of Form work to edges of concrete flats, floor and roofs not exceeding 20cm wide (horizontal or sloping), rough finish surfaces complete all as specified and directed by Engr in charge.
M&L for providing RCC 1:1-1/2:3 type B1 (using 20mm graded stone aggregate) as in beams, lintel over 1.5m clear span, lintel bands etc; complete all as specified and directed by Engr in charge.
M&L for providing RCC 1:1-1/2:3 type B1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in roof, landings, balconies, canopies and in shelves etc; complete all as specified and directed by Engr in charge.
M&L for providing RCC 1:1-1/2:3 type B1 (using 20mm graded stone aggregate) as in chajjas etc; complete all as specified and directed by Engr in charge.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, includingcranking, bending spirally for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engr in charge.
M&L for Mild steel TMT bars 6 mm to 8mm dia over bent to shape required, including cranking, bending & binding as in stirrups / rings complete all as specified and directed by Engr in charge.
M&L for plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregates as over roof for good depression/ undulation to the existing roof surfaces as filling in depression of roof slab/ floor padding etc complete all as specified and directed by Engr in charge.
M&L for carrying out water proofing treatment for roofs in the following stages - (i) Rendering 10mm thick in cement mortar (1:4), mixed with integral water proofing liquid all as per manufacturer's instructions over concrete surfaces finished even and smooth with out using extra cement. Note : (WPC shell be measured separately and paid for under respective item of schedule). (ii) Material and labour for UV stable single component fibre reinforced elastomeric liquid applied waterproofing membrane having solid content of 55% formulated wih PU hybrid polymers and reinforcing acrylic fibres and having sun reflectivity Index (SRI) of 106. The application of the material should be done in three coat (6 hr gap after each coat) on the substrate, applying first self priming coat at ratio of damp proof ultra and water 3:1 then 2 undiluted coat of damp proof ultra obtaining coverage @1 ltr/10 sqft in two coats (10-12 hrs gap between each coat. The vital physical and chemical parameters shall be as under. Min elongationat break of 350%, crack bridging ability of 2.5 mm @650 microns thickness, resists positive hydrostatic pressure of up to 10 bars. The material shall be appliied with brush or roller, complete all as specified and directed by Engr in charge. Also, proper surface preparation along with covingat corners is must. Note : - The work shall be executed by the authorized applicator of the manufacturer only. Note : - 1.The authorized applicator of manufacturer shall be approved by GE. 2.The color of final finish shall be decided by the GE
Supply only integral water proofing liquid ISI marked complete all as specified and directed by Engr in charge.
Demolition of cement concrete (unreinforced) in ground floor not exceeding 15cm thickness below or above ground level including floor finishes and removing debris from the site complete all as specified and directed by Engr in charge.
Dismantling glazed tiles/ kota stone/ terrazzo tiles any type as in dado/ skirting etc; including cement mortar bedding ( but not backing ) complete all as specified and directed by Engr in charge.
M&L for non skid ceramic coloured tiles of approved shade and pattern, 7 to 8 mm thick , area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm laid in floor, set and jointe (square/ rectangular) in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed by Engr in charge.
M&L for glazed ceramic coloured tiles of approved shade and pattern of size 350x 250x7mm/ 450X350X7mm/ 300X450X7 to 8mm thick or any other nearer size as approved by Engineer incharge in vertical surface set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in CM 1:4 as in backing coat of tiles complete all as specified and directed by Engr in charge.
M&L for light shade virified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and directed by Engr in charge.
M&L for light shade virified ceramic tiles 10 mm thick (square/ rectangular) polished, exc 0.42 sqm but not exceeding 1.00 sqm, as in skirting (Matching with floor tile of the same room) set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and directed by Engr in charge.
M&L for 20mm thick granite (colour as approved) work (table rubbed and polished) in steps, shelves, jambs, pillars, window-cills, cooking platforms (vertical/ horizontal) and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 10mm thick screed bed or bedding layer in CM 1:4 complete all as specified and directed by Engr in charge.
M&L for machine cut kota stone slab flooring 20-25mm (+ 2mm) thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and directed by Engr in charge.
M&L for mirror polished machine cut Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including 10mm thick rendering in CM 1:4 and jointed complete all as specified and directed by Engr in charge.
M&L for Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in plinth protection, 50 mm thick, surfaces finished even and fair without using extra cement including provision of construction joints complete all as specified and directed by Engr in charge.
M&L for Stone slab 25 mm to 35 mm thick dressed true and square, in one length not less than 60cm and n. exc 120cm in as in Plinth Protection, chajja etc., punched dressed on exposed faces and self faced on the embedded unexposed beds and joints; exposed edges rounded or chamfered as directed, set, jointed and pointed in CM in 1:4 complete all as specified and directed by Engr in charge.
M&L for 75mm thick PCC 1:4:8 type D-2, (40mm graded stone aggregate) as in sub floor, sub bases, floor and paving etc; complete all as specified and directed by Engr in charge.
M&L for Providing and laying 60mm thick factory table vibratory, PU mould, chamfered edge cement concrete coloured paver block of M-35 grade with approved design & pattern as in footpath, drive ways or parking etc; over and including 50mm thick compacted bed of fine sand and proper embedding/ laying of inter locking paver blocks into the sand bedding layer, filling the joints with sand and cutting of paver blocks as required, complete all as specified and directed by Engr in charge.
M&L for factory precast cement concrete solid blocks M-30 Grade, using 20 mm graded crushed stone aggregate as in kerb stones of any size (with plain or interlocking joints as directed) set in cement mortar 1:4 for path edgings etc; embedded in position including all necessary excavation, tamping ground arround blocks and removal of rubbish/ surplus soil etc., complete all as specified and directed by Engr in charge.
M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in kerbs or benching etc including necessary form work complete all as specified and directed by Engr in charge.
Demolition of stone/ brick work masonry, built in cement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stone work, serviceable stone aside for reuse and removing unserviceable material in low laying area complete all as specified and directed by Engr in charge.
M&L for squared rubble walling jodhpur type, brought upto course, well bonded bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed by Engr in charge.
-ditto- all as per above item but, except stone complete all as specified and directed by Engr in charge.
Extra over for hammer dressing to face stones with maximum depression on face from a straight edge not exc 20mm and dressing face beds and joints as specified to squared rubble walling,Jodhpur type, brought upto courses complete all as specified and directed by Engr in charge.
M&L for brick work with fly ash bricks (old size bricks), straight or curved on plan exc 6mtr mean radius, built in cement mortar (1:6) complete all as specified and directed by Engr in charge.
M&L for Brick work using old size bricks (EXCEPT BRICKS) straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar (1:6), complete all as specified and directed by Engr in charge.
Taking down cement plaster, any description, on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc and disposal of debris complete all as specified and directed by Engr in charge.
M&L for rendering 15 mm thick in CM 1:6 over stone masonary, concrete surfaces, finished even and smooth (without using extra cement), complete all as specified and directed by Engr in charge.
M&L Keyed pointing to random or polygonal rubble, uncoursed or brought upto course of cement mortar (1;4) complete all as specified and directed by Engr in charge.
M&L for 10mm thick rendering in CM 1:3 on ceiling surfaces finished surfaces even and smooth without using extra cement complete all as specified and directed by Engr in charge.
M&L for carrying out water proofing treatment for sunken portion in the following stages - (i) Taking down of existing sunken slab treatment from the sunken portion and cleaning the surfaces washing down with water and rubbish of the pemises , cleaning and filling cracks with sealing compound, brushing neat cement slurry @ 3.00kg/sqm and grouting 25mm thick cement concrete type B-0 (1:2:4) using 12.5mm graded stone aggregate on sunken slab portion and finishing the top surfaces even and smooth without using extra cement. (ii) M&L for two coat of acrylic cementitious water proofing coating (Dr FIXITpidifin 2k manufactured by M/s Pidilite Industries Ltd or equivalent) and followed by a overlay protective screed (10mm thick cement mortar (1:4) along with liquid water proofing compound approved as per manufacturer's instructions) on top surfaces of sunken slab after preprations as mentioned above. Method of application for acrylic cementitious water proofing coating achieved as per manufacturers instruction complete all as specified and directed by Engr in charge.
Dismantling cast iron work of any description and in any position complete all as specified and directed by Engr in charge.
S&F 100mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, laid in trenches or in floor etc; complete all as specified and directed by Engr in charge.
S&F 100mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, fixed to walls etc; complete all as specified and directed by Engr in charge.
S&F 75mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, laid in trenches or in floor etc; complete all as specified and directed by Engr in charge.
S&F 75 mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, fixed to walls etc; complete all as specified and directed by Engr in charge.
S&F 100mm bore pipe cast iron 'P' or 'S' trap, complete all as specified and directed by Engr in charge.
S&F 75mm bore pipe cast iron 'P' or 'S' trap, complete all as specified and directed by Engr in charge.
S&F 100mm bore pipe cast iron cowls, complete all as specified and directed by Engr in charge.
M&L cast iron up to 150mm bore fittings of Bends (any type, radious and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces, single branch, 'Y' junctions, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc; complete all as specified and directed by Engr in charge.
M&L 100mm bore cast iron pipes and fittings joints or connections are filled/ sealed properly by epoxy sealant of ISI mark or M-Seal apply as per manufacturing instructions, complete all as specified and directed by Engr in charge.
M&L 75mm bore cast iron pipes and fittings joints or connections are filled/ sealed properly by epoxy sealant of ISI mark or M-Seal apply as per manufacturing instructions, complete all as specified and directed by Engr in charge.
S&F for 100mm bore pipes stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall etc; complete all as specified and directed by Engr in charge.
S&F for 75mm bore pipes stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall etc; complete all as specified and directed by Engr in charge.
M&L cement concrete type E-2, 1:5:10 (40mm graded crushed stone aggregate) as in sunken portion complete all as specified and directed by Engr in charge.
S&F in repair 40mm bore steel water tubing medium grade galvanised inserted at the end of lateral slope projecting at least 15cm beyond the outer most projected part of the building below the drain pipe up to two storey construction as spout for sunken complete all as specified and directed by Engr in charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc 4.00 sqm each and removing from site or to store complete all as specified and directed by Engr in charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each and removing from site or to store complete all as specified and directed by Engr in charge.
Taking down shutters any description exc 1.00 sqm but not exc 2.00 Sqm each and refixing the shutter in same opening after easing and adjusting complete all as specified and directed by Engr in charge.
S&F of pressed steel framed of 1.25mm thick MS sheet, of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, complete all as specified and directed by Engr in charge.
M&L for cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate as in fillings and mass concrete, filling backs of chowkats etc., complete all as specified and directed by Engr in charge.
M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in lintels upto 1.50 m clear span, cills , steps, seismic and other similar bands, copings, kneelars, apex stones, bed plates, bed blocks of hold fasts etc including necessary form work complete all as specified and directed by Engr in charge.
M&L 40mm thick flush shutter, solid core construction, with particle board core and plywood face panels, commercial type on both side complete all as specified and directed by Engr in charge.
S&F of factory 35 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) kiln seasoned and chemically pressure treated complete all as specified and directed by Engr in charge.
M&L for fabrication of aluminium powder coated window any pattern & design (openable with hinges, sliding, tilt and turn, casement , fixed type, villa type, ventilators) fabricated with anodized aluminium rectangular or any type section in frame with approved design & patterns including provn of fixing galvanised mild steel wire cloth on the outer side of frame etc; fixed in position complete all as specified and directed by Engr in charge. Note:- Glass pane & wire cloth shall be measured and paid separately under respective Items of Sch 'A'.
S&F for figured glass, pin head type ordinary quality, 4mm thick, area of each pane not exceeding 0.5Sqm and glazing with aluminium beading in aluminium frame complete all as specified and directed by Engr in charge.
S&F of sheet glass ordinary quality 4 mm thick and glazing with oil putty or fixed with wooden beads or fixed with rubber gasket in squares any size of pane complete all as specified and directed by Engr in charge.
.-Ditto- all as per above item but 4mm thick frosted glass complete all as specified and directed by Engr in charge.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engr in charge.
S&F of Factory Solid PVC Moulded Door Shutter of with particle board core , 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, fix in frame at site as per specification & drawing complete all as specified and directed by Engr in charge.
S&F of solid PVC door frame of size 50mm x 47mm of 5.0 mm single side prelam PVC sheet & edges will be painted to match with prelam sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engr in charge.
S&F of 100 mm size Stainless Steel (as approved by Engineer incharge) butt hinges complete all as specified and directed by Engr in charge.
S&F stainless steel door handles fancy type 150 mm long and fixed with steel screws complete all as specified and directed by Engineer-in-charge.
S&F of stainless steel barrel tower bolts, with bright bolt, 150 mm long and fixed with steel screws complete all as specified and directed by Engr in charge.
S&F of 300 mm long stainless steel sliding door bolt, fancy type with bright bolt not less than 12 mm dia with and including bolts and nuts complete all as specified and directed by Engr in charge.
S&F of mild steel rat tail rod pattern helical door spring of size 300mm including roller and roller plate fixing to iron frame by welding complete all as specified and directed by Engr in charge.
S&F of framed work as in doors chowkats of MS angle iron or MS hollow square/ rectangular any type/ size with gusset plates, rails, braces,cooler stand, chajja framed complete drilled for fixing of door etc; to be prepared for hanging with and including hold fasts and locking arrangements confirming to FE- 290 (Gde-E- 165) complete all as specified and directed by Engr in charge.
S & F for Providing Kitchen Cabinet anti fungal,moisture resistence,anti borer,100% water Proof,flame retardant. in required sizes at site of 18mm thick 100% Solid WPC Plain board of required size 18mmthick(WPC) Wood polymer composite sheet & provision of shutters of 18 mm thick 100% Solid WPC Plain board all required brackets SS screws etc. The panels shall be fabricatedusing adhesive and screws where ever required. as per drawing and specification a.including taking down and removal of old unserviceable boarding of any description and in any position, complete all as specified and complete all as specified and directed by Engr in charge.
Providing and fixing (WPC) Wood polymer composite sheet (WPC) Wood polymer composite coated Pre-laminated (one side decorative & other side balancing lamination sheet) density 600 kg/m3, frame of width 150mm & 18mm thickness of extruded 18mm WPC sheet and joined with suitable Cement Solvent adhesive and screw.The frame shall be fixed to the wall using 75mm long M.S. Screws through the frame by using(WPC) Wood polymer composite fasteners. A minimum of 3 Nos. of screws to be provided for each vertical member & minimum 2 Nos. for horizontal member etc, complete all as specified and directed by Engr in charge.
S&F of hydraulic hinges for kitchen cabin door shutter of mild steel bright finish or elecrogalvanised, fixede with screw etc; complete all as specified and directed by Engr in charge.
S&F of mild steel butt hinges 100mm long, medium weight cold rolled fixed with steel chowakats etc; complete all as specified and directed by Engr in charge.
S&F of mild steel single action helical hinges 150-200mm long, suitable for 1000-1250mm wide wooden door fixed with steel chowakats etc; complete all as specified and directed by Engr in charge.
S&F of alluminium anodised cast type handles 100 mm long fixed to windows complete all as specified and directed by Engr in charge.
S&F in repair of decorative Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. 32mm dia including fixing brackets & side cups complete fixed complete all as specified and directed by Engr in charge.
S&F of powder coated aluminium anodised deco grill weighing not less than 1.40 kg/ sqm and fixing necessary joining cleats/ frame etc; complete all as specified and directed by Engr in charge.
Taking down 15mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specified and directed by Engr in charge.
Taking down 20mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specified and directed by Engr in charge.
Taking down 25mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specified and directed by Engr in charge.
S&F of 15mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and directed by Engr in charge.
S&F of 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and directed by Engr in charge.
S&F of 25mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and directed by Engr in charge.
Refixing 15mm bore old serviceable steel water tubing any grade with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and directed by Engr in charge.
Refixing 20mm bore old serviceable steel water tubing any grade with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and directed by Engr in charge.
Refixing 25mm bore old serviceable steel water tubing any grade with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and directed by Engr in charge.
S&F Vitreous China wash down water closet pan (pedestal pattern) with shhet cover, white (including fixing bolts, and flush pipe and connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete all as specified and directed by Engr in charge.
S&F in repair PVC 10 ltr. Cap. valveless syphonic action type, flushing cictern, low level, white/ coloured with inlet, ball valve, float and handle including brackets and connection to pipe etc. complete all as specified and directed by Engr in charge.
S&F in repair CP health faucet with 15mm bore flexible pipe of 1.50mtr long complete all as specified and directed by Engr in charge.
M&L as in repair 75 mm PVC (SWR) floor trap, plain with SS grating including jointing with solvent cement 75 mm bore, including jointing to waste pipe set in cement concrete type B-1(1:2:4) in repairs, complete all as specified and directed by Engr in charge.
S&F in repair vitreous china wash basin, white/ coloured, flat back, size 550x400mm including PTMT waste fittings, 32mm bore size, waste pipe pvc 32mm bore and angle iron brackets of required size and length etc. and good disturbed surfaces to match with the existing complete all as specified and directed by Engr in charge.
S&F 450 mm long PVC connection with PTMT nuts on both ends for 15mm bore pipes of approved quality complete and fixed in repair complete all as specified and directed by Engr in charge.
Disconnecting existing PVC tank exc 250 Ltrs and not exc 500 Ltrs setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting refixing in position complete all as specified and directed by Engr in charge.
S&F in repair 500 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe all as specified in SSR Part-I complete all as specified and directed by Engr in charge.
S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 23cm wide with chromium plated bracket guard and railing complete all as specified and directed by Engr in charge.
S&F MS chromium plated peg set of 05 pegs fixing with wall complete all as specified and directed by Engr in charge.
S&F as in Corner Glass shelf 250mm superior quality with CP tubular framing & brackets complete all as specified and directed by Engr in charge.
S&F in repair Soap dish fancy type, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engr in charge.
S&F in repair tubular towel rail 20mm dia brass chromium plated `D' type 60cm long with bracket and fixed complete all as specified and directed by Engr in charge.
S&F in repair 15mm bore chromium plated bib taps, fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engr in charge.
S&F in repair for pillar tap, brass, 15mm dia, with capston heads, chromium plated, fancy type screwed down, high pressure, with or without lettered hot or cold, with long shank, screwed shanks and fly nuts, screwed for iron pipes or for wash hand basin complete all as specified and directed by Engr in charge.
S&F in repair 15mm bore stop valve/ angle stop cock chromium plated, fancy type cast copper alloy, screwed down, high pressure, screwed both ends for iron pipe with long shank and cup complete all as specified and directed by Engr in charge.
Supply & fix in repair brass chromium plated wall mixer suitable size for both telephonic shower and overhead shower with long bend pipe complete all as specified and directed by Engr in charge.
Supply & fix in repair 15mm dia single lever one hole basin mixer of superior quality with capstan heads, cromium plated cast copper alloy with hot and cold arrangements with long shank and cup , screws for iron pipe fixed complete all as specified and directed by Engr in charge.
S&F in repair 25mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed by Engr in charge.
S&F in repair chromium plated shower roses 125mm size with or without swivel joints, any size, including fixing to steel pipe or union suitable for 15mm bore pipe etc; complete all as specified and directed by Engr in charge.
S&F in repair Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed by Engr in charge.
S&F in repair Grating square (SLIT) 150mm of CP with anti cockroach assembly complete all as specified and directed by Engr in charge.
S&F Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105gms) complete all as specified and directed by Engr in charge.
S&F in repair Ball valves of 20 mm dia high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 2 0mm-210gms) complete all as specified and directed by Engr in charge.
M&L for Preparing new or previously untreated surfaces of wood and wood based material of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engr in charge.
M&L for Preparing new or previously untreated surfaces of steel or iron work of any description and girth over 10cm and applying two coats of synthetic enamel paint complete all as specified and as directed by Engineer in charge.
M&L for Preparing new plastered surfaces and M&L for applying chalk whitening/ concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of Distemper oil Emulsion on new plastered surfaces all as directed by Engr in charge.
M&L for Preparing new plastered surfaces and M&L for applying concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engr in charge.
M&L for Preparation of new plastered surfaces of walls etc. & applying three coats of lime white wash on walls complete all as specified and directed by Engr in charge.
M&L for Preparation of new plastered surfaces of ceiling etc. & applying three coats of lime white wash on ceiling complete all as specified and directed by Engr in charge.
M&L for Preparing of old painted wooden surfaces or wood based material of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engr in charge.
M&L for Preparing old painted steel surfaces or iron work of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engr in charge.
Complete removal of existing treatment by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots incl washing , rubbing down and stopping of distempered or painted surfaces and M&L for applying chalk whitening/ concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of Distemper oil Emulsion on old treated surfaces of walls complete all as specified and directed by Engr in charge.
Complete removal of existing treatment by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots incl washing , rubbing down and stopping of distempered or painted surfaces and M&L for applying concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm old treated surfaces of walls complete all as specified and directed by Engr in charge.
M&L for Preparation of old decorated plastered surfaces of walls etc. & applying one coat of white wash complete all as specified and directed by Engr in charge.
M&L for Preparation of old decorated plastered surfaces of ceiling etc. & applying one coat of white wash on ceiling complete all as specified and directed by Engr in charge.
Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed by Engr in charge.
Taking down carefully UNSV main switch and DB's including MCBs of any size , type and capacity and depositing at site complete all as specified and directed by Engr in charge.
M&L for point wiring complete for one light point / exhaust fan point / bell point controlled by one 1-way switch/ bell push, with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers with and including FRLSH PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing modular switches / sockets etc and good surface by wall panelling etc, complete all as specified and directed by Engr in charge. Note : 1. The cost of modular type Metal flush boxes and modular accessories like inner/outer cover plates etc is deemed to be included in quoted rate. 2. The cost of cutting chases on wall and good surface on wall are deemed to be included in the quoted rate
All as per srl item no. 134 here-in-before but for one socket outlet 3 pin, 5 Amps on independent board complete all as specified and directed by Engr in charge.
All as per srl item no. 134 here-in-before but for one socket outlet 3 pin, 5 Amps on same board complete all as specified and directed by Engr in charge.
All as per srl item no. 134 here-in-before but for one light point controlled by two 2-way switches complete all as specified and directed by Engr in charge.
All as per item No 134 here in before but with single core multistranded cable of size 4 Sqmm for one 15 Amps socket outlet/AC point on independent board and multistanded insulated copper earth continuity conductor of size 4 Sq mm complete all as specified and directed by Engr in charge.
S & F in replacement Modular switch 1 way 6A , 1 module size complete all as specified and directed by Engr in charge.
S & F in replacement Modular switch 2 way 6A , 1 module size complete all as specified and directed by Engr in charge.
S & F Modular switch 1 way 16A , 1 module size complete all as specified and directed by Engr in charge.
S & F in replacement Modular Bell push way 6A with 2 module size with indicator complete all as specified and directed by Engr in charge.
S & F in replacement Modular Socket , 6 A , 5 Pin , 2 module size complete all as specified and directed by Engr in charge.
S & F in replacement Modular Socket , 6 A / 16 A , 5 Pin , 2 module size complete all as specified and directed by Engr in charge.
S&F in replacement modular type regulator 2 module-120 W A/C 240 Volts complete all as specified and directed by Engr in charge.
S&F in replacement of wall mounting light fitting, Decorative type, wall mounting incl suitable size 9W retrofit LED bulb and necessary electric connection, complete all as specified and directed by Engr in charge.
Supply and fixing in replacement Ceiling rose on PVC FRLS board size 65 X 50 mm three terminal complete all as specified and directed by Engr in charge.
S&F in replacement electric call bell ding dong AC 230 volts Single Pole complete all as specified and directed by Engr in charge.
S&F in replacement of LED light fitting 1 X 20 watt (4 feet), T5 Rechargable Emergency Batten Light, has power backup of 3 to 4 hours, a slim design with internal driver, complete with all accessories and necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed by Engr in charge.
S&F in replacement of LED light fitting 1 X 10 watt (2 feet),complete with all accessories and necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed by Engr in charge.
S&F in replacement bldg security LED Light Luminaire of 60 Watts having IP 65 protection fiting of pressure die cast Aluminium housing, operating Voltage 140-270 Volts with in built surge protectore, toughened glass with fixing of GI pipe 40 mm band including drilling holling nuts & bolts 2 code of red oxide paint on GI pipe and fixing with wall security light on building wall complete all as specified and directed by Engr in charge.
Taking down ceiling fan from existing position and keep in safe custody for refix after completion of work with all necessary connection complete all as specified and directed by Engr in charge.
M&L for dismantling and Removing old burnt copper wire winding of ceiling fans of any size & sweep of any and rewinding with new enameled super copper wire of existing gauge as per old copper winding incl providing insulation by varnishing , cleaning, oiling, greasing etc complete all as specified and directed by Engr in charge.
S &F of plastic ventilating fan 250 mm sweep plastic body including louvers with cutting chases and grounting with nut bolts on aluminium frame/iron window complete all as specified and directed by Engr in charge.
S&F sheet metal enclosure SPN 240 Volts having 2 pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed by Engr in charge.
S&F in replacement of Distribution Board, double Door, of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 12 way (Concealed flush to wall), 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and all necessary connections, duly flush of wall surface, complete all as specified and directed by Engr in charge.
S&F in replacement of MCB, B Curve type, 10 kA, 63Amp, SPN with over load and short circuit protection, complete all as specified and directed by Engr in charge.
S&F in replacement of MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as specified and directed by Engr in charge.
Taking down old sub main wiring and M&L for concealed sub main wiring with 2 run of 10 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and inc l10 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit suitable size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as specified and directed by Engr in charge. Note : Two run of 10 Sq.mm. and one run of 10 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including good the disturbed surfaces.
All as per srl item no. 159 here-in-before but with 2 run of 4.0 sq mm FRLS copper wire with one run 4 Sqmm FRLS copper cable as earth wire complete all as specified and directed by Engr in charge.
Supplying and fixing single phase two wire dual source prepaid energy meters BIS 15884 marked in existing meter board / floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 Volt accuracy class 1.0 alongwith parallel home display split unit including connection wire from meter to rooms with inbuilt load control switch containing provision for TOD and RTC, capable to define for tariff slabs, happy hours and holiday definition complete all as specified and directed by Engr in charge. Note : Taking down old unserviceable existing meter and deposit to MES store yard with proper reading.
Supply, laying, testing and commissioning of LT UG cable XLPE insulated galvanized steel strip heavy duty armoured electric power cable with stranded aluminium conductor 1100 volts grade 70 sq mm 3.5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and connection, complete all as specified and directed by Engr in charge. Note : 1. The cost of aluminium thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
M&L for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth lead wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point on completion with and including 15 mm bore GI light grade protection pipe (7.5 mtr long) for earth lead GI lead wire 4mm dia (7.5 mtr long), PCC pit with cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia tor bars @ 80mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work, complete all as specified and directed by Engr in charge.
Taking down and refixing Storage type water heater (Geyser ) from wall by disconnecting the electric connection and water inlet/outlet connection from main and repairing the water heater storage type capacity 25/35 ltrs upto 3 KW of any type and , Checking the serviceability of all parts such as inner vesser, rubber gasket, non return valve, heating element, thermostat etc and refixing the same after replacing of Unsv parts and assembly complete (considered as one unit) and installing & testing the same complete all as specified and directed by Engr in charge. Note : All unsv parts if reqd to be replaced shall be measured and paid separately under respective item of Sch 'A' as supply only.
Supply only heating element including rubber ring, washer, holding clamps and nuts of geyser upto 3.0 KW capacity of suitable size complete all as specified and directed by Engr in charge.
Supply only thermostat suitable for upto 3.0 KW geyser complete all as specified and directed by Engr in charge.
S&F in replacement electric water storage geyser 2 KW & 25 ltr capacity assembly/body except heating element & thermostat including all electrical components parts complete all as specified and directed by Engr in charge.
Supply only PVC connection (heavy duty) of 15 mm dia with required length with 2 Nos of brass, chromium plated nuts of approved & quality complete all as specified and directed by Engr in charge.
Excavation in trenches in loose / soft soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide and getting out including trimming of sides, for laying of cables & foundation of poles, stay assembly, complete all as specified and directed by Engr in charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr in charge.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed by Engr in charge.
M&L for factory un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr in charge.
M&L for Sand cushioning to protection of underground cables, laid 8 cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18 cm thick, complete all as specified and directed. Note : Punned thickness shall be measured and sand cover to UG cable, complete all as specified and directed by Engr in charge.
S&F of galvanized iron pipe of 50 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall, complete all as specified and directed by Engr in charge. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
PANWAR ELECTRICALS (BID ID -3280784)
M/S KAUTILYA GARG (BID ID -3287766)
M/s Ajay kumar Garge (BID ID -3288058)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .