Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAdmitted-Finance NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | ₹18.4 L | L1 | Admitted-Finance |
| 2 | L2₹22.2 LAdmitted-Finance 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | ₹22.2 L | L2 | Admitted-Finance |
| 3 | L3₹24.9 LAdmitted-Finance | ₹24.9 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | RASAM ENGINEERING COMPANY L2 | BK CONSTRUCTION L1 | Onkar Electricals L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for preparation of existing old painted surface of any description such as Panels any height and painted completed with one coats of primer (superior quality) and in smokey greay color all around the panels. (Make of Paint : Asian, Berger or equivalent.) | 50 | Each | 950 ₹47,500 | 2,500 ₹1.3 L | 4,000 ₹2 L |
| 2.00 | Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 450 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-
(A) INCOMING
(i) MCCB, 4 Pole, 415V, 50HZ,250 Amps 25KA micro processor -01 No.
(ii)Motorised Changeover Switch SS Enclosure 250 Amp -02 Nos
(B) OUTGOING
i) MCCB, 4 Pole,415V, 50HZ 125 Amps 16 KA adjustable thermal and magnetic -01 Nos
(ii) MCB, TPN 'C' Series,240V, 50HZ 63 Amps 10KA -04 Nos
(iii) MCB , SPN 'C' Series ,240V/415 V , 50HZ 63 Amps 10 KA -04 Nos
(iii) MCB , SPN 'C' Series ,240V/415 V , 50HZ 32 Amps 10 KA -04 Nos (iv) Digital Multifuction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set
(v) LED Type Phase indicator lamps for three phases set of three - 01 set
(vi) Busbar chamber having insulated aluminium busbar, each suitable for 450 Amps for three phases and neutral -01 Set
(vii) Spare space for MCCB of same capacity -01 Nos | 1 | Each | 2,25,000 ₹2.3 L | 2,50,000 ₹2.5 L | 2,25,000 ₹2.3 L |
| 3.00 | M & L in repair for fabrication of bus bar chamber of size 80cmx60cmx40cm for 415 volts 3 phase 4 wire system with MCCB 400A ,25 KA ,4 pole, out going MCCB 63 Amps - 04 Nos ,outdoor type, with digital volt amp meter ,double door, withpedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 1.2 mtr above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge .
Note :- Comprising of 4 nos. Aluminium bus bar 200 Amp for phases & 100 Amp for neutral mounted on DMC/ porcelain insulator support complete all as specified and directed. | 5 | Each | 1,20,000 ₹6 L | 52,000 ₹2.6 L | 40,000 ₹2 L |
| 4.00 | Expertise and labour only for load balancing of feeder complete after removing all service cables connected to all the three phases, checking these for ohmic value, leakage if any and connecting to all the three phases in such a sequence so that load is nearly balanced in all the three phase complete all as specified and directed. | 10 | Each Job | 500 ₹5,000 | 2,500 ₹25,000 | 5,000 ₹50,000 |
| 5.00 | Inspection/checking & testing after repair of APFC panel 3 Phase,440 voltage 50Hz AC supply system to improve power factor 0.80 to 0.99 automatic step wise switched capacitor panel to make it serviceable in auto and maunal mode, with the help of connecting relays, capacitors,contactors,MCB"s.,CTs, re-wiring burnt/worn out control wires etc and rectifying the defects, replacement of unserviceable parts as required at site and cleaning of AMFAPFC panel as detecting during inspection or pointed out by department and carry out maintenance complete all as specified as directed by Engineer-in-Chrage.(Notes :-This items includes the cost of cleaning & rewiringof panel. Spare parts required shall be measured and paid for separately under respective items as supply only) | 5 | Each Job | 4,000 ₹20,000 | 6,500 ₹32,500 | 10,000 ₹50,000 |
| 6.00 | Supply only in replacement of APFC microprocessor based relay up 8 stage PFC controller ,230 volts complete all as specified and directed by Engineer-in-Charge. Make-L&T/EPCOS/Siemens | 4 | Each | 8,900 ₹35,600 | 12,500 ₹50,000 | 10,620 ₹42,480 |
| 7.00 | Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 10 KVAR complete all as specified and as directed by Engineer-in-Charge. | 4 | Each | 4,500 ₹18,000 | 3,500 ₹14,000 | 3,800 ₹15,200 |
| 8.00 | Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 15 KVAR complete all as specified and as directed by Engineer-in-Charge. | 5 | Each | 6,000 ₹30,000 | 3,800 ₹19,000 | 5,500 ₹27,500 |
| 9.00 | Supply only in replacement of capacitor duty contactor 3 phase suitable upto 20 KVAR capacity 240 volts complete all as specified and as directed by Engineer-in-Charge. Make- Epcos, L&T | 5 | Each | 3,000 ₹15,000 | 4,500 ₹22,500 | 8,000 ₹40,000 |
| 10.00 | Supply only of capacitor duty contactor 3 phase suitable upto 5 KVAR capacity 240 volts complete all as specified and as directed by Engineer-in-Charge. Make- Epcos, L&T | 5 | Each | 2,200 ₹11,000 | 3,500 ₹17,500 | 3,500 ₹17,500 |
Updated dates
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
25 May 2026, 6:00 pmClosed
Harikesh Meena EE
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2026_MES_762540_1
8977
Open Tender
Electrical and Maintenance Works
270 days
GE ARMY BARODA
As per tender documents
9 documents required · 9 mandatory
₹500
GE ARMY BARODA
₹30,000
Yes
30 May 2026
28 Apr 2026
26 May 2026
28 Apr 2026
25 May 2026
13 May 2026
29 Apr 2026 - 5 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for preparation of existing old painted surface of any description such as Panels any height and painted completed with one coats of primer (superior quality) and in smokey greay color all around the panels. (Make of Paint : Asian, Berger or equivalent.) | 50 | Each | - | - |
| 2 | Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 450 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-
(A) INCOMING
(i) MCCB, 4 Pole, 415V, 50HZ,250 Amps 25KA micro processor -01 No.
(ii)Motorised Changeover Switch SS Enclosure 250 Amp -02 Nos
(B) OUTGOING
i) MCCB, 4 Pole,415V, 50HZ 125 Amps 16 KA adjustable thermal and magnetic -01 Nos
(ii) MCB, TPN 'C' Series,240V, 50HZ 63 Amps 10KA -04 Nos
(iii) MCB , SPN 'C' Series ,240V/415 V , 50HZ 63 Amps 10 KA -04 Nos
(iii) MCB , SPN 'C' Series ,240V/415 V , 50HZ 32 Amps 10 KA -04 Nos (iv) Digital Multifuction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set
(v) LED Type Phase indicator lamps for three phases set of three - 01 set
(vi) Busbar chamber having insulated aluminium busbar, each suitable for 450 Amps for three phases and neutral -01 Set
(vii) Spare space for MCCB of same capacity -01 Nos | 1 | Each | - | - |
| 3 | M & L in repair for fabrication of bus bar chamber of size 80cmx60cmx40cm for 415 volts 3 phase 4 wire system with MCCB 400A ,25 KA ,4 pole, out going MCCB 63 Amps - 04 Nos ,outdoor type, with digital volt amp meter ,double door, withpedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 1.2 mtr above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge .
Note :- Comprising of 4 nos. Aluminium bus bar 200 Amp for phases & 100 Amp for neutral mounted on DMC/ porcelain insulator support complete all as specified and directed. | 5 | Each | - | - |
| 4 | Expertise and labour only for load balancing of feeder complete after removing all service cables connected to all the three phases, checking these for ohmic value, leakage if any and connecting to all the three phases in such a sequence so that load is nearly balanced in all the three phase complete all as specified and directed. | 10 | Each Job | - | - |
| 5 | Inspection/checking & testing after repair of APFC panel 3 Phase,440 voltage 50Hz AC supply system to improve power factor 0.80 to 0.99 automatic step wise switched capacitor panel to make it serviceable in auto and maunal mode, with the help of connecting relays, capacitors,contactors,MCB"s.,CTs, re-wiring burnt/worn out control wires etc and rectifying the defects, replacement of unserviceable parts as required at site and cleaning of AMFAPFC panel as detecting during inspection or pointed out by department and carry out maintenance complete all as specified as directed by Engineer-in-Chrage.(Notes :-This items includes the cost of cleaning & rewiringof panel. Spare parts required shall be measured and paid for separately under respective items as supply only) | 5 | Each Job | - | - |
| 6 | Supply only in replacement of APFC microprocessor based relay up 8 stage PFC controller ,230 volts complete all as specified and directed by Engineer-in-Charge. Make-L&T/EPCOS/Siemens | 4 | Each | - | - |
| 7 | Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 10 KVAR complete all as specified and as directed by Engineer-in-Charge. | 4 | Each | - | - |
| 8 | Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 15 KVAR complete all as specified and as directed by Engineer-in-Charge. | 5 | Each | - | - |
| 9 | Supply only in replacement of capacitor duty contactor 3 phase suitable upto 20 KVAR capacity 240 volts complete all as specified and as directed by Engineer-in-Charge. Make- Epcos, L&T | 5 | Each | - | - |
| 10 | Supply only of capacitor duty contactor 3 phase suitable upto 5 KVAR capacity 240 volts complete all as specified and as directed by Engineer-in-Charge. Make- Epcos, L&T | 5 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_854154.xls
BOQ • 6.70 MB
Tenderpages8977.pdf
Tender Documents • 0.42 MB
Download all tender documents and submit your bid