| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.8 LAccepted-AOC HM 324 PHASE IX SAS NAGAR MOHALI PB | ₹81.8 L | L1 | Accepted-AOC Lowest bidder and found reasonable |
| 2 | L2₹84.9 L+₹3.0 L (3.72%)Rejected-Finance 164 SECTOR 21A CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹84.9 L+₹3.0 L (3.72%) | L2 | Rejected-Finance Other than Lowest |
| 3 | L3₹88.8 L+₹7.0 L (8.50%)Rejected-Finance | ₹88.8 L+₹7.0 L (8.50%) | L3 | Rejected-Finance Other than Lowest |
| 4 | L4₹89.8 L+₹8.0 L (9.79%)Rejected-Finance 96 SECTOR 16 A CHANDIGARH 160015 | CHANDIGARH | CHANDIGARH | 160015 | ₹89.8 L+₹8.0 L (9.79%) | L4 | Rejected-Finance Other than Lowest |
| 5 | L5₹1.0 Cr+₹20.3 L (24.8%)Rejected-Finance | ₹1.0 Cr+₹20.3 L (24.8%) | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹93.7 L
EMD Value
₹1.7 L
Closing Date
15 Aug 2023, 6:00 pmClosed
CWE(AF) Tughlakabad
Military Engineer Services Commander Works Engineers Air Force, Tughlakabad PO-Sangam Vihar New Delhi -110 080
ADDN / ALTN TO TO AI-20 OH LINE AT BRD, AF CHANDIGARH UNDER GE (AF) MC CHANDIGARH
2023_MES_608469_3
CWE/TKD/CHD/TOKEN-21 OF 2023-24
Open Tender
Civil Works
Item Rate
270 days
GE(AF) MC Chandigarh
As per Tender/NIT Documents
8 documents required · 8 mandatory
₹1,000
GE(AF) MC Chandigarh
₹1.7 L
Yes
23 Sept 2023
27 Jul 2023
17 Aug 2023
27 Jul 2023
15 Aug 2023
2 Aug 2023
Amount
Sch 'A' Part -I (Building Works)
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quions, arches, pillars etc, but exluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L Cutting openings, through brick walls for door, window and other openings or enlarging existing openings converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and directed .
M&L cutting holes in brick walls exc half brick but n exc one brick in mud mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 using 20mm graded stone aggregate as required complete all as specified and directed .
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and directed .
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc 4.00 Sqm each complete all as specified and directed.
Taking down cement plaster on brick wall including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors , aprons etc. laid, bedded and pointed in any mortar complete all as specified and directed.
Dismantling of aluminium work as in partition wall cubicals with boards & glass/ window/door frame/shutter or any other locations including removal from site complete all as specified and directed.
Dismantling of wrought or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling asbestos cement corrugated or semi-corrugated sheets as in roof coverings (including ridge) complete all as specified and directed.
All as per item No.10 here-in-before but CGI sheets roofing
Dismantling of ceiling board with frame complete (any type) fixed in any position complete all as specified and directed.
Hacking out old broken glass from metal frame or wooden frames incl punching or drilling out old glazing pins/spring clips and providing and fixing new ones of any area complete all as specified and directed.
Material and labour for brickwork with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for cement conc 1:5:10 type E2 using 40mm graded stone aggregate as in foundations,filling and mass concreting complete all as specified and directed.
M&L rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed .
M&L rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L two coats of Oil Bound distemper over a coat of alkali resistant primer over a coat of 1-2mm thick wall care putty including preparation of plastered or unplastered new wall surfaces complete all as specified and directed .
M&L two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 1-2mm thick wall care putty including preparation of plastered or unplastered old wall surfaces including complete removal of existing treatment complete all as specified and directed .
M&L two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 1-2mm thick wall care putty including preparation of plastered or unplastered old celing surfaces. including complete removal of existing treatment complete all as specified and directed .
M&L for 16-18mm thick marble work (Abu white , table rubbed and polished) for wall lining (veneering to wall) in cement mortar 1:3 and pointing with white cement 1:2 using marble dust with admixture of pigment to match with shade of stone over and including 15 mm thick cement screed base laid in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified & directed .
M&L for 18-20mm thick machine cut kota stone slab flooring over and including 15 mm thick cement screed base laid in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified & directed .
Excavation as in soft/ loose soil as in post holes (or similar holes) each n exc 0.5 cum getting out,ramming, watering ,returning filling in and removing surplus soil to a distance not exc 50m concrete complete all as specified & directed .
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregates as in foundation , mass concrete complete all as specified & directed .
S&F for steel work in tubular tresses (square/rectangular/ circular section of any size & thickness) including bending in any shape (circular/semi-circular / eliptical /parabolic) washer etc complete using ERW or induction butt welded tubes confirming to IS -1161-1979 grade St-240 complete all as specified and directed .
S&F MS plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe-410-W(Gde-E-250) ,complete all as specified and directed .
S&F pre- painted galvatume aluminum zinc coating GI based steel plain sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F painted galvatume aluminum zinc coating GI based as per approved profile steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F 0.8mm thick mild steel plain black sheet but in hearths covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs,ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched,including round headed screws, clout nails or rivets and fixed to wood or steel members, etc.,with plain 40 mm lap joints or welded/riveted seams including bending, turning up mitred angles stopped ends outlets etc. as required complete all as specified & directed .
S&F for 6mm thick multi wall clear/bronze/green/blue polycarbonate sheet with specially designed powder coated aluminium sections (alocx-system or equivalent) EPDM rubber gasket, silicon sealants, cold forged fastners etc on steel structure complete all as specified and directed.
S&F in framed work for grills, gratings etc with ends of bar shouldered and for riveted or welded framed work guard bars and similar work complete all as specified and directed.
S&F in rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates confirming to Fe-410-W(Gd-E-250) quality A complete all as specified and directed.
S&F in GI/MS fastenrs 100 mm long suitable for fixing MS brakets for sunsheds and similar work complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint of approved shade over & including a coat of red oxide primer incl preparation untreated steel or iron surfaces exc 10cm width or girth complete all as specified and directed.
Providing and fixing aluminium work for frame/shutter/fixed portions of doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per specified and directed. (Glazing, paneling to be paid for separately) : (Mim Thickness of Section shall not be less than 1.5 mm)((minimum thickness of polyster powder coating 50 micron)
S&F 4 mm thick aluminium composite panels(ACP) fixed in aluminium doors/partition or any other frame work including joint sealing complete all as specified & directed .
S&F 4.8mm thick plain glass not exc 0.5 sqm in each pane fixed to aluminium door/ windows and iron frame complete all as specified & directed .
All as per item No-37 here- in- before but exc 0.5 sqm in each pane fixed to aluminium door/ windows and iron frame complete all as specified & directed .
S&F rough cast wired glass, 6.4mm thick and glazing with silicon in square exc 0.5 sqm but not exceeding 0.75 sqm in each pane complete all as specified & directed .
S&F 200 mm size powder coated (any tint) aluminium "American Handle" fixed to aluminium door with suitable screws complete all as specified and directed .
Providing and fixing 150 mm long aluminium handles, ISI marked, powder coated (minimum thickness of powder coating 50 micron) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and directed.
Providing and fixing ISI marked aluminium butt hinges of size 100x75x4 mm powder coated (minimum thickness of powder coating 50 micron) transparent or dyed to required colour or shade with necessary screws etc. complete all as specified and directed.
All as per item No-42 here- in- before but 75mm.
Providing and fixing 150 mm long aluminium tower bolts, ISI marked, powder coated (minimum thickness of powder coating 50 micron) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and directed.
All as per item No-44 here- in- before but 200mm
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge NOTE:- The contractor shall submit purchse voucher for claimaing payment in RAR/Bill.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 50 kg and door width 850 mm to 1000 mm), with necessary accessories and screws etc. complete NOTE:- The contractor shall submit purchse voucher for claimaing payment in RAR/Bill.
Providing and fixing aluminium hanging floor door Twin rubber stopper, ISI marked, powder coated (minimum thickness of powder coating 50 micron) transparent or dyed to required colour and shade, with necessary screws etc. complete
M&L 12mm thick glass reinforced gypsum (GRG) ceiling tiles of size 595mm x 595mm of approved design fixed with powder coated GI grid of size main Tee (15 x 32mm) cross Tee (23 x 15mm) and wall angle (18 x 12mm) suitable for mounting tiles of 595 x 595mm including fabricating complete all as per manufacturer instructions including necessary for hanging rod/wire 4mm dia of any length as per site requirement and any height complete all as specified and directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
M & L PCC 1:2:4 type B-0 (12.5 mm graded stone agg ) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed .
Supply only liquid integral water proofing compound complete all as specified and directed.
M&L APP based polymeric membrane minimum weighing not less than 3Kg/sqm and minimum 4 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms /Sqm ) over and including a coat of cold applied bitumen 85/25 based primer on entire surface @1.20 Kg /Sqm over and including 10mm thick rendering in CM 1:4 using water proofing compound (as per Manufature's instructions) over and including 50mm thick PCC 1:3:6, type C1 by using 20 mm graded stone aggregate in padding/mass concrete and haunching in required slope to avoid any logging of water on dry and clean surfaces including demolition of existing treatment of APP/Mud Phuska/BrickTile/PCC etc. and stacking the same at the location specified by GE at distance n.exe 100 m along with cleaning of surface with water jet and preparing the surface by rubbing with wire brush all as specified & directed. Note : 1. The two coat of solar reflective Bituminiuos Aluminum painting over APP shall be carried out and the cost of the same shall be included in quoted rate. 3. The contractor shall submit Purchase voucher of APP, Aluminum Paint to GE for claiming payment. The same shall be fwd to office of Accepting officer along with final bill.
M&L for 40mm thick brick tiles laid over and including 15mm thick screed bed in cement mortar 1:6 , joints grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement on mud phuska including dismantling of brick tiles or terracing tiles, single layer on roof and placing on the location as specified by engr-in-charge but n.exe. 100m complete all as specified and directed.
All as item No.54 here-in-before but except tiles complete all as specified and directed.
M&L applying two coats of solar reflective bituminous aluminium paint over old surface of APP membrane @ 0.20 Kg/Sqm for two coats complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as directed
M&L for non-skid ceramic coloured joint free tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 300x450x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for Acid resistant tiles 15mm thick vitreous ceramic, unglazed, set,jointed and pointed in chemical resistant mortar, resin type, in floors complete all as per manufacturer instructions,specified and directed.
S&F in repair 5mm thick coloured wood grain printed PVC sheet strips in wall panelling over and including PVC frame and overlap strips and corner angles complete inclusive of solvent cement and fixing at site complete all as per manufacturer instructions,specified and directed.
Taking up or down 15mm bore steel water tubing and connection including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20mm bore steel water tubing and connection including cleaning for refixing or removal to store all as specified.
S&F for GI tubing medium grade 15mm bore with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed .
S&F for GI tubing medium grade 20mm bore with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed .
Dismantling of PVC water storage tanks capacity exc 250 ltrs but n exc 500 Ltrs complete all as specified and directed.
All as per item No.66 here-in-before but capacity exc. 500 ltrs but n exc .1000 Ltrs.
S&F rotational moulded polyethylene (tripple Layer) water storage tanks 500 Ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I,complete all as specified and directed.
S&F rotational moulded polyethylene (tripple Layer) water storage tanks 1000 Ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I,complete all as specified and directed.
S&F 20mm ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed
S&F 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified.
S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed.
M&L for filling siliconized sealant around steel/wooden frame around rough cast wire glass 6.4mm thick to cover all side gaps of glass panes with suitable layer (approximate 20mm width in both side)by silicon Gun as per instructions by manufacturer to stop the water leakage from that potion including removing the existing treatment around the glass panes up to height 15mtr etc complete all as specified and as directed.
Sch 'A' Part -II (Electrification Works)
Material and labour for point wiring (concealed) in and including rigid stove enamelled steel conduit, 19/20 mm dia/suitable size as per site requirement including cutting chases for conduits, sinking for boxes for concealed conduit wiring with 1.5 sqmm FRLS PVC insulated unsheathed multi stranded copper conductor cable in and including flush type metal boxes suitable for modular switches and socktes ,fan regulators etc with brass screw, cup washer and including PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm as earth wire connected to common earth and earth dolly as per IS specification, specified and directed.for the One light/fan/bell point controlled by one switch.
All as per item No 73.01 above but for 05 Amp independent socket complete.
All as per item No 73.01 above but with 4 sqmm copper conductor for main wire and earth work for 15 Amp independent socket complete.
S&F switch modular, 1 module single pole one way 6 Amp complete all as specified and directed.
S&F socket outlet 6 Amp modular, 2 module complete all as specified and directed.
S&F switch modular, 1 module single pole one way 16 Amp complete all as specified and directed.
S&F socket outlet 6/16 Amp multipurpose modular, 2 module complete all as specified and directed.
Supply and fixing ceiling rose 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
S&F LED slim flat panel 36 watt having lumen output more than 3200 lumens suitable for false ceiling of cut out size 2'x2' including making connection complete all as specified and directed. NOTE:- The contractor shall submit purchse voucher for claimaing payment in RAR/Bill.
Supply and fix in replacement MCB DB TPN 04 way sheet steel phospetised powder painted with IP 43 protection 415 V nautral link, earth bar and Din rail double door complete all as specified and as directed.
Supply and fix MCB SP 5 to 16 Amps complete all as specified and directed.
Supply and fix MCB TPN 63 Amps complete all as specified and directed.
Supply & fixing ISI marked air circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified and directed. NOTE:- The contractor shall submit purchse voucher for claimaing payment in RAR/Bill.
Supply & fixing exhaust fans AC single phase 230/ 240 V of size 450 mm sweep 1400 RPM with louver complete all as specified and directed.
Supply & fixing exhaust fans AC three phase 415 V of size 900 mm sweep 700 RPM with starter and louver including cutting hole in brick wall and making good disturbed area complete all as specified and directed.
Supply & fixing heavy duty pedestal fan AC single phase 230/240 V of sweep 450 mm complete all as specified and directed. NOTE:- The contractor shall submit purchse voucher for claimaing payment in RAR/Bill.
Material and labour for four single core PVC Insulated unsheathed multi stranded FRLS copper conductor cable of size 2.5 sqmm as sub main wiring including suitable size heavy duty rigid PVC conduit and of PVC insulated unsheathed multi stranded FRLS copper conductor cable of size 2.5 sqmm as an earth continuity conductor complete all as specified and directed. Note:-4 run of 2.5 sqmm (phase & neutral) +1 run of 2.5 sqmm for earth will be measured as one RM
M&Lfor earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 3mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI wire of dia 4 mm by means of bolts, nuts, check-nuts and washers of galvanized iron and thimbles and of earth wire protected by galvanized iron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No 3 of SSR-2009 (Part-I). Note :-The earth value/result shall be less than 5 ohms.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core to be laid in duct/on tray complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core to be laid in duct/on tray complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core to be laid in duct/on tray complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core to be laid in duct/on tray complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core to be laid in duct/on tray complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core to be laid in duct/on tray complete all as specified and directed.
NOTE for Item no. 92.00 to 96.00 The Testing certificate shall be fwd to office of Accepting Officer for at the time of Final Bill.
Supply and fixing cable tray stainless steel powder coated of size 300mm x 54 mm in three meter length complete including all supporting components to mount the tray on wall complete all as specified and directed.
M&Lfor earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI strip of size 32 x 6 mm by means of bolts, nuts, check-nuts and washers of galvanized iron and thimbles and of earth strip protected by galvanized iron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 3 of SSR-2009 (Part-I). Note :-The earth value/result should be less than 5 ohms.
Supply, installation, commissioning and testing of high wall mounted split type unit AC 1.5 TR operated on 410A/407C refrigerant gas, not less than 5 star rated, with cordless remote, operated on single phase AC supply 230 volts including necessary making holes, cutting chases for refrigerant pipes , connection cable etc in brickwall, necessary MS brackets for fixing outdoor/indoor units, made out of structural steel sections duly painted with two coats of synthetic enamel paint over a coat of red oxide making good to disturbed area and matching with the existing surface, PVC heavy duty conduit pipe 2mm thick laid concealed in brickwall from inner unit to outside, necessary refrigerant pipes including PVC insulated 3 core 4 sqmm copper flexible cable of required length from inner unit to outer unit and for socket point of voltage stabilizer etc complete all as specified and directed. Note:- The copy of PV shall be submitted by contractor for claiming payment in RAR. Non-submission may lead to non-payment
Supply, installation, commissioning and testing of automatic voltage stabilizers single phase 3 KVA capacity operated on single phase supply, designed for input voltage between 170 volts to 260 volts and output voltage stabilised at 230 volts + 8% including necessary connection etc complete all as specified and directed. Make : Volina/V Guard/Sinetrac/Bluebird
Dismantling from site split AC (indoor & outdoor unit) of capacity 1.5/2.0 TR carefully and re-install the same to designated location including cutting chases or making hole as per site requirement including filling of refrigerant gas complete all as specified and directed.
S&F sheet metal enclosure with socket plug top and MCB Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
Material and labour for sub main wiring (concealed) two single core PVC insulated unsheathed multi stranded FRLS copper conductor cable of size 4 sqmm as sub main wiring including suitable size medium grade rigid steel conduit and of PVC insulated unsheathed multi stranded FRLS copper conductor cable of size 4 sqmm as an earth continuity conductor complete all as specified and directed. Note :- 2 runs of 4 sqmm copper conductor, 01 run of conduit and 01 run of earth continuity conductor of size 4 sqmm shall be measured as one RM.
Supply, laying and testing of Carbon Steel Seamless pipes for compressed air line , Grade (ASTM) A-106 Grade B ,Sch 40, laid in Duct/wall with flanged & welded joints including all fittings such as bends, unions, reducer, elbow, socket, tee etc. with packing nuts, bolts, washers and necessary connection wherever required, testing as specified, for 50 mm dia. bore pipe and testing complete all as speicfied and as directed. Note:- The copy of PV shall be submitted by contractor for claiming payment in RAR. Non-submission may lead to non-payment
Supply, laying and testing of Carbon Steel Seamless pipes for compressed air line , Grade (ASTM) A-106 Grade B ,Sch 40, laid in Duct/wall with flanged & welded joints including all fittings such as bends, unions, reducer, elbow, socket, tee etc. with packing nuts, bolts, washers and necessary connection wherever required, testing as specified, for 15 mm dia. bore pipe and testing complete all as speicfied and as directed. . Note:- The copy of PV shall be submitted by contractor for claiming payment in RAR. Non-submission may lead to non-payment
M&L for cutting existing compressed air line of size 80 mm dia and making branch connection with suitable size of tee and jointing material complete all as specified and directed.
S&F valve butterfly S/S grade TP 304 complete of size 50 mm dia complete all as specified and directed. Note:- The copy of PV shall be submitted by contractor for claiming payment in RAR. Non-submission may lead to non-payment
S&F valve butterfly S/S grade TP 304 complete of size 15 mm dia complete all as specified and directed. Note:- The copy of PV shall be submitted by contractor for claiming payment in RAR. Non-submission may lead to non-payment
Schedule of Credit
MS SACHDEVA BUILDERS
shree balaji builders
Anil Kumar Gupta
J and K constructions company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .