Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.7 LAccepted-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L1 | Accepted-AOC BEING ELIGIBLE AND LOWEST BIDDER | |
| 2 | L2₹42.9 L+₹12,999.03 (0.30%)Rejected-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹43.3 L+₹57,777.40 (1.35%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹46.3 L+₹3.6 L (8.42%)Rejected-Finance 141 SHANTI NAGAR MODEL TOWN MODEL TOWN PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Electricals India L1 | MONA GENERATOR SEVICES PVT. LTD. L2 | Chanda Construction Co. L4 | ARTI CONSTRUCTION L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, install, commissioning and testing factory made (including CPRI approved manufacturer) LT panel box (KIOSK) out door type size not less then size 1500mm W x 1500mm H x 500mm D platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 300 amps rating installed on porcelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 Mix, type B2 of Suitable size over the ground level upto 1 Mtr height. 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should have anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangements as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of allthe following complete all as specified and directed :- (SMQ 64-65, 66-67, 68-69, MT 01 No, Near Mandir Old Darjipura,Gas Agancy) | 6 | EACH JOB | 1,69,200 ₹10,15,200 Lowest | 1,83,080.92 ₹10,98,485.52 | 2,02,000 ₹12,12,000 | 1,72,584 ₹10,35,504 |
| 1.01Incomer:- (a) MCCB FP 200 A 36 kA with Electronic microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 1.5 to 10.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 no | |||||||
| 1.02(b) 4 Nos Aluminium Bus bars of 400 Amp current rating capacity, of suitable size of length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator complete with nut bolt fixing arrangement complete - 01 set | |||||||
| 1.03Outgoing :- (c) MCCB FP 100 A 16 kA with Adjustable Thermal release for over load 0.7 to 1.0 and Adjustable magnetic release (10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -05 Nos | |||||||
| 1.04Metering Compartment | |||||||
| 1.05(f) Digital type Amp meter 0-200 Amp(size 96mmx96mm) with Selector switch and 3 Nos CT of ratio 250 A/5A-1No | |||||||
| 1.06(g) Digital Type volt meter 0-500 V with selector switch -1Nos | |||||||
| 1.07(h) Digital Multifunction meter having for mearing KW, KVA KVRa, KWAH, KVAH , Pf, Hz etc-1Nos | |||||||
| 1.08(i) RYB LED incating lamp -3 Nos | |||||||
| 1.09Note :- (i) Cost of taking out old unserviceable panel is deemed to be included with unit rate of item. (ii) Earth work, PCC base etc is deemed to be included with unit rate of item. (iii) All MCCB to be onstalled vertically therefor panel shall be designed accordingly. (iv) Taking Out Existing MCCBs of any Capacity from old LT Panel to be fixed in any other LT Panel Board wherever required and rate will be inclusive in this item for fixing or deposited in MES Yard store. This will not measured as schedule Credit items | |||||||
Tender Value
₹43.7 L
EMD Value
₹87,370
Closing Date
13 Oct 2025, 6:00 pmClosed
GE (AF) BARODA ,DARJIPURA
GE (AF) BARODA ,DARJIPURA , GUJARAT-390022
SPECIAL REPAIR TO LT DISTRIBUTION PANELS AND DAMAGE LT CABLE DURING STORM AND RAIN AT OLD DARJIPURA AT AFS VADODARA
2025_MES_731088_1
8122/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DARJIPURA AF STN
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) BARODA
₹87,370
Yes
26 Nov 2025
15 Sept 2025
15 Oct 2025
15 Sept 2025
13 Oct 2025
29 Sept 2025
15 Sept 2025 - 29 Sept 2025
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .