| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹21.5 LAccepted-AOC 602 DOLI CHAMBERS 06TH FLOOR BRAHMAKUMARIS MARG NEAR STRAND CINEMA COLABA MUMBAI CITY 2829 400058 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L 1 | Accepted-AOC AOC | |
| 2 | L 2₹22.1 L+₹64,900 (3.02%)Rejected-Finance | L 2 | Rejected-Finance L 2 | |
| 3 | L 3₹26.2 L+₹4.7 L (21.9%)Rejected-Finance 85 AMALANGSHU SEN ROAD KOL 700048 | KOLKATA | KOLKATA | WEST BENGAL | 700048 | L 3 | Rejected-Finance L 3 |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
23 Sept 2020, 2:00 pmClosed
Executive Engineer, BNED,PWDte.
Room No.119 1st Floor,Purta Bhawan Kolkata - 700091
Supply of firefighting extinguishers for the use of various Offices Academic Building Laboratories in the Campus of Electrical PanelMeeter GeneratorTransformar Security room I Big Car parking area of A P J Abdul Kalam Govt College at New t
2020_WBPWD_295526_3
WBPWD/EE /BNED/NIeQ-8 of 2020-2021
Open Tender
CIVIL WORKS
Item Rate
120 days
Rajarhat, New Town, Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹25,000
3 Sept 2021
8 Sept 2020
25 Sept 2020
9 Sept 2020
23 Sept 2020
9 Sept 2020
Amount
CO2 ALUMINIUM 4.5 Kg. Fire Extinguisher - Vessel used in the manufacturing should be constructed using Cold Impact Extrusion. Diameter of shell up to 150 mm and mounted on trolley. Sheet metal thickness should not less than: 4.0 mm. 5. Material of construction should be [Al Alloy 6061].9. Gross weight should be within the range of 13.90 to 14.40 kg. Content mass should be within the range of 4.275 to 4.725 kg. Service pressure and Maximum service pressure of extinguisher should be 70 bar and 156 bar respectively. Discharge time should not less than 12 Secs. Applicable on Class B, C & Electrically started fire. Fire rating should be class B: 55 B. • Certification : 1. The current and valid BIS certification IS: 15683 needs to be submitted along with offer. 2. The vessel should be PESO Approved. 3. The Product should be EN PED Approved and CE marked. 4. The bidder must have valid PESO license to refill and store compressed gas cylinders as per Gas Cylinder rules 2004. 5. The carbon dioxide gas shall conform to IS 15222 with latest amendment. 6. Discharge valve shall be conform to all the requirement given in IS 3224:2002 or latest version thereof. 7. The Co2 Cylinder shall be conform to all the requirement given in IS 7285:2004. 8. Minimum Fire rating as per IS: 15683 Class B: 55B needs to be provided for the extinguisher. 9. The firm should submit the product performance test report from NABL accredited Lab as per IS 15683. warranty - 10 years.
Stored Pressure Water mist Portable Fire Extinguisher Capacity 6 Liter. (Stainless Steel) for Class A, F & Electrical Fires. Stored Pressure EN3-7, EN3-8 and EN3-9 tested & certified along with IS marked as per IS:15683 : The body of the extinguisher shall be of Stainless Steel. The Diameter of shell is 175mm. Sheet metal thickness should not less than: 1.5MM. Material of construction should be [SS 304(1.4301))]. Gross weight should be within the range of 10.30kg to 10.90kg. Content mass should be 5.70kg to 6.00Ltr. Discharge hose should provided and length of flexible section should not be less than 460mm. 11. Serial no. and date of manufacturing should be embossed on the body of the fire extinguisher. Extinguisher should be stored pressure type. Extinguisher must have a tamper-proof safety pin to avoid unintended use. Min. Discharge Time should be 42 Seconds. The working pressure should be at least 15 bars. Actual burst pressure should not be less than 105bar. Bulk range throw should be minimum 2.00 Meters. The extinguisher must have a Pressure Gauge to enable the checking of pressure gauge’s working without dismantling or opening of the cylinder. The equipment should have a specialized rotor to mix propellant and agent to help in producing fine mist. Extinguisher must be Helium Leak Detection Tested & test report must be furnished at the time of delivery. As per IS: 15683, Fire rating should be class A: 3A As per EN 3-7, Fire rating should be class A: 13A and Class F: 75F. Applicable on A, F and electrically started Fire. • Certification : The current and valid BIS certification IS 15683:2006 needs to be submitted along with the offer. The firm should submit the product performance test report from NABL accredited Lab as per IS 15683. The Product should be certified by any EN notified body as per EN 3-7, EN 3-8, EN 3-9. The firm shall submit the product certificate from an EN notified body. The Product should be EN PED Approved and CE marked. Electrical Test Certificate - Certification from ERDA as per IS 15683 - 2006 (Cl. No. : 8.6) & BS EN3-7:2004+A1:2007 (E) (Cl. No. : 9). Warranty - 6 years.
CAFS(Compressed Air Foam System) Watermist fire ectinguisher 50 liter trolley mounted Low pressure design 55a, IVb, 1000v - . Trolley Mounted Water mist & Compressed Air Foam ( CAF) System – 50Ltr–Technology : Water Mist & CAFS Fire Extinguisher with Low Pressure Dual Phase technology. (As per DIN EN 1866-1:2007-10 Standards) Water Container Capacity -50 liters. Water Cylinder working pressure- – 05 to 12 bars. water cylinder construction - Non Corrosive Stainless Steel SS 316. Water Cylinder external paint-The cylinder should be of red color with powder coating. The paint should confirm to IS:5:2007 Shade 538. Operating working pressure- Not more than 11 bars. Air Bottle – certification- PESO (Petroleum and explosive safety organization). Total weight - Empty Filled - Not more than 54 kg. (Empty). Not more than 105 kg (Water Bottle filled & Air bottle capacity - 6 liters / 300 bar air. Air Bottle - construction - Seamless Mild Steel Cylinder. Operating temperature - Minimum +5 degree to maximum +60 degree Celsius.Gun – construction - 1. rDevice operation - Shall be suitable for both left and right hand operations. Fire extinction – suitability - Class – A, Class – B ,Live Electrical fires - 1000 V as per EN 3-7/IS - 15683 (Tested for 36 kva). System Test : Electrical Test Certificate - With details of test methods - Certification from ERDA as per IS 15683.Fire Rating Certificates:- Certification from NABL accreditated Indian Lab as per EN3-7:2004+A1:2007 (test reports not older than 48 months from the date of bidding).Fire Rating Certificates: For Class A- Minimum A 55. Fire Rating Certificates: For Class B - Minimum II B. Warranty - - 36 Months (Air Cylinder). Spare parts support - 10 years.
Lamonte Enterprise
SAYAN CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .