Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.7 LAccepted-AOC COMET ELECTRICAL ENGINEERING CO KOTTAKKAL MALAPPURAM | 1 | Accepted-AOC AEE/LIDEW-DIV/MPM/057/24-25 |
Tender Value
₹5.0 L
EMD Value
₹12,454
Closing Date
12 Aug 2024, 6:55 pmClosed
EXECUTIVE ENGIEER
Office of the Executive Engineer, LID and EW Division, Malappuram, civil station, Malappuram District Panchayath Building, Malappuram, 676505
Annual Plan-Malappuram District Panchayath Conference hall electrification and public address system for District Homeo Hospital Munduparamb Providing Air Conditioner-S0464/25-General Electrical Work(Retender)
2024_LSGD_684066_1
DB1/TN/06/24-25
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
MALAPPURAM
Please refer Tender documents.
11 documents required · 11 mandatory
₹1,180
₹12,454
Yes
24 Sept 2024
5 Aug 2024
14 Aug 2024
5 Aug 2024
12 Aug 2024
5 Aug 2024
Amount
ELECTRIFICATION
OD27058/2024-2025:Supply, installation, testing and commissioning of wall mounting type 3 star Copper Condenser Invertor split air conditioner unit conforming io IS 1391(Part II)(amendments-1 except power consumption norms) fitted with hermetically sealed compressor operating on 230V single phase AC supply, R32/R134/R410 /non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc with copper condensing coil,white / off white colour of
OD27093/2024-2025:Supply, installation, testing and commissioning of wall mounting type 3 star Copper Condenser Invertor split air conditioner unit conforming io IS 1391(Part II)(amendments-1 except power consumption norms) fitted with hermetically sealed compressor operating on 230V single phase AC supply, R32/R134/R410 /non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc with copper condensing coil,white / off white colour of following capacity, with cordless remote control etc with one year warranty for machine and 3 years for compressor. 1 Tr 3 star single phase Invertor split AC unit including Cu pipe connection & electric cabling from indoor to outdoor unit upto 3m ( (O General /Voltas /Blue star/Carrier /LG DUAL Inverter )
OD27043/2024-2025:Supply and providing 5KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and output range of 210-240V
OD27106/2024-2025:Supply and providing 3 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and output range of 210-240V
OD27154/2024-2025:Supply and providing Heavy Duty AC Outdoor Wall Mounting Bracket Stand | Outdoor Ac Unit| Ac Stand Outdoor for 1 Ton, 1.1 Ton, 1.2 Ton, 1.5 Ton, 2 Ton etc aws required
OD27045/2024-2025:Supply and providing following size soft drawn Copper pipe for extending pipe between out door and indoor units including insulating pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc. 3/8(9.52mm) and 5/8 (15.8mm) 22 gauge
OD27046/2024-2025:Supply and providing following size Drain pipe for condensate drain to the nearest drain point with 32mm U PVC pipe insulated using 9mm thick Nitrile Rubber tubing as per Client/Engineers instruction
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.8:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Bidder Name
ANSARI KUNDIL
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1064411.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .