Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹17.2 L+₹22,263 (1.31%)Rejected-Finance 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹18.0 L+₹1.1 L (6.21%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹19.4 L+₹2.5 L (14.7%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹19.5 L+₹2.6 L (15.2%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹21.4 L
EMD Value
₹42,800
Closing Date
12 Jun 2024, 6:00 pmClosed
Col Manish Dhaka CWE
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
PROVN OF HT SWITCHGEAR AND CANNECTED ITEMS AT GANDHINAGAR
2024_MES_654005_1
82198/CHL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Gandhinagar
As per tender document
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Chiloda
₹42,800
Yes
4 Jul 2024
15 May 2024
19 Jun 2024
15 May 2024
12 Jun 2024
29 May 2024
16 May 2024 - 18 May 2024
Amount
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc completed all as specified and directed.
Returning, filling including spreading, leveling watering & well ramming in laying not exc. 25cm for not exc. 25 cm thick for soft/ loose soil complete all as specified and as specified and as directed.
M & L Dry Sand cushioning to underground cable with screened, washed river sand, including punning gently all as specified and directed. Note: - Thickness after punning will be measured for payment.
Removal of excavated material at a distance not exc 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point for soft/loose soil complete all as specified and as directed.
M&L 100mm bore GI tubing light grade with all fittings for Laying in trenches in road cross / floors as in cable protection complete all as specified
Labour only for boring under road/drain by manual method for inserting the light grade pipe GI tubing up to 100 mm dia for cable protection complete all as specified and directed by Engineer In Charge.
Supplying and laying reinforced precast concrete cable cover, class EHV, Type 1, flat, size 450 mm x 180mmx 40mm as in under ground cable protection complete all as specified and directed by Engineer in Charge.
S&F Cable jointing kit suitable for cable of size 95 sqmm to 120 sqmm 3 core, 11000 volts grade cable for indoor end termination, heat shrinkable type joint with jointing material and accessories complete all as specified
S&F Cable jointing kit suitable for cable of size 95 sqmm to 120 sqmm 3 core, 11000 volts grade cable for outdoor end termination, heat shrinkable type joint with jointing material and accessories complete all as specified
Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts earthed grade with stranded aluminium conductor of size 95 sq mm 3 core complete all as specified. Note:- Excavation / earth work will be measured and paid under respective item.
M&L Earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth strip of 32X6mm size by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation &earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 15 mm bore GI tubing medium grade as in watering pipe, lugs, 40 mm bore light grade GI as in protection pipe, test point etc. complete all as specified and directed. Note: (i) Rate quoted under this item is deemed to include the cost of 7.5m length of earth strip and its protection tube.
Supply install, testing and commissioning indoor type HT 11 KV, 3 Phase, 50Hz motorised operated Ring main unit IP 54 enclosure, totally enclosed metal clad SF6 switchgear having rupturing capacity upto 630 Amps, one incoming three outgoing (VVVV+M) fully enclosed, compact, factory assembled cabinet inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200 . Switchgear Operating Mechanism shall have an IP2X Protection and Cable Chamber shall have IP3X Protection. Each 3 Pole Load Break Switch shall comprise of 11 kV, 630 Amps 21 kA / 3 Seconds, , Short Time Current [STC] 21 KA for 3 Sec, Rated Power Frequency Withstand Voltage of 28 KV, Rated Lightning Impulse Withstand Voltage 75 KVp. Fault Passage Indicator System [FPIS] & Voltage Presence Indicator System [VPIS], Self-Powered microprocessor controlled Numerical Protection Relay for Short Circuit, Over Current and Earth Fault with auxiliary power, battery and battery charger. The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/ replacement purposes. Cable covers with self-Interlocking mechanism between doors, earth switch, disconnector & VCB Capacitive voltage indication fixed type system Mechanical Indications for breaker ON, OFF, EARTH, TRIP, Spring Charged-Discharged.
RMU shall have complete accessories such as Ring core current transformer type 30/1A, 2.5 VA, 5P10 for protection, Space heater with thermostat (230V AC), Terminal boots, cable supports, all front cable termination boots, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60265-1, 62271-102,62271-100 and 60694.Suitable for altitude of installation up to 1000m as per IEC 60120. Note:- (i) All civil works including foundation for RMU to be carried out as per manufacturer's specification and the amount for the same are included in the rates quoted. (ii) Necessary T & P , transportation etc are included in the rates quoted. (iii) Installation, testing & commissioning will be done by OEM rep. (iv) It is preferable to have a design of accommodating minimum five nos. modules in a single tank wherever applicable (v) Necessary HT cable connection with lugs etc. are included in the rates quoted.
Electricals India
ARTI CONSTRUCTION
ALBA AC AND REF SERVICES
Vending Services And Solutions
RISING ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .