Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC 95 A GOVIND NAGAR RACE COURSE OPP GURUDWARA DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹10.2 L+₹2.8 L (38.4%)Rejected-Finance SHOP NO 02 GROUND FLOOR SAMUDRIKA CHS PLOT NO 183 URAN RAIGAD MAHARASHTRA 400 702 | RAIGAD | MAHARASHTRA | 400702 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹10.2 L+₹2.8 L (38.5%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest |
Tender Value
₹10.5 L
EMD Value
₹21,000
Closing Date
3 Feb 2022, 6:00 pmClosed
GE Clement Town
GE Clement Town MES Dehradun
REPAIR TO DRAIN, PATH, CULVERT, SEWAGE LINE AND MISC WORKS OF NHO UNDER AGE B/R-III OF GE CLEMENT TOWN
2021_MES_490367_3
GE/CLT/ Of 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE Clement Town
Class E Cat a(ii)
7 documents required · 7 mandatory
₹500
Yes
GE Clement Town
₹21,000
Yes
15 Feb 2022
19 Jan 2022
5 Feb 2022
19 Jan 2022
3 Feb 2022
22 Jan 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m deep in soft/loose soil for foundation, etc. or for shafts, wells, cesspits, manholes, pierholes, etc. and getting out complete all as specified and directed.
M&L for returning filling in soft/loose soil including spreading levelling watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
M&L for removing excavated material (Soils) to a distance not exceeding 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
M&L 200mm internal dia of pipe salt glazed stoneware drain pipes grade 'A', laid in trenches and jointed in cement & sand mortar (1:1), including demolition and breaking up drain pipes (SGSW) of 200mm bore complete all as specified and directed.
M&L for concrete bed in PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200 mm bore pipe complete all as specified and directed.
S&F 150mm internal dia of pipe salt glazed stoneware drain pipes grade 'A', laid in trenches and jointed in cement & sand mortar (1:1), including demolition and breaking up drain pipes (SGSW) of 150mm bore complete all as specified and directed.
M&L for concrete bed in PCC (1:3:6) type C-2 ( using 40 mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified and directed.
M&L for Cleaning of blocked/filled W.C (any type) by roding the CI/SWG pipe of any dia upto first manhole/gully trap after taking off the cover and placing the same in position after cleaning and removing the waste material/sludge etc complete all as specified and directed.
Cleaning of Floor/Nahani/Gully trap washing with clean water up to Ist manhole after taking of manhole cover and placing the same in position after cleaning and removing the waste material/sludge etc complete all as specified and directed.
Demolition of (reinforced) cement concrete (reinforcement cut as required to facilitate demolition) of any description in any position not otherwise specifically provided for complete all as specified and directed.
M&L reinforcement cement concrete type B-1 (1:2:4) slab supported on wall using (20mm graded crushed stone aggregate) for slab supported on walls, beams and columns in floors , roofs landings, balconies, canopies deck slab and in shelves and the like complete all as specified and directed.
M&L for reinforced precast cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for manholes etc.), shelves and similar articles with plain faces including necessary form work, set in cement mortar (1:4) complete all as specified and directed. (Note:- Reinforcement shall be measured and paid for separately)
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columms,hooking ends and binding with and including mild steel wire annealed not less than 0.90 mm dia or securing with clips complete all as specified and directed.
M&L for Formwork to flat soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surfaces complete all as specified and directed.
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roof n.exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n.exc 20 cm wide complete all as specified and directed.
M&L for cutting into existing manholes for connecting new drains 150mm dia making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) smooth finished and reforming benching as required complete all as specified and directed.
Dewatering of soak well or sewage pit of any dia and depth manually or by using pump and removal of sludge if any to a distance exc 1.5 Km but not exc 5 Km out of MOD land complete all as specified and directed.
Removing of small vegetation /bushes /roots /plants/grass etc from any potition of buildings and removel of rubbish to a distance exc 50m and including making good disturbed surface by repair work including matching with the existing surface complete all as specified and directed.
Opening of manhole covers, taking out sludge from septic tanks, inspection chambers, man holes by removing sludge in solid, semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5 Km but n.exc 5 Km out of MOD land complete all as specified and directed. (Note:- Measurements will be taken only after dewatering of the septic tank) and no extra payment will be made for dewatering the same.
M&L for cleaning of hume pipe culvert or RCC culvert of any dia (Length of culvert not exc. 6 m) by excavation in mud/debris and decayed plants, manually under culvert and removing excavated material out of defence land, including minor repair to culvert complete all as specified and directed.
M&L for cleaning of SGSW Pipe 150 mm internal dia of any depth by rodding or by using pressure pump completely including man holes and removal of sludge to a distance exc 1.5 Km and n.exc 5 Km out of MOD land complete all as specified and directed.
M&L for cleaning of SGSW Pipe 200 mm internal dia of any depth by rodding or by using pressure pump completely including man holes and removal of sludge to a distance exc 1.5 Km and n.exc 5 Km out of MOD land complete all as specified and directed.
M&L for cleaning of SWG Pipe 100 mm internal dia of any depth by rodding or by using pressure pump completely including man holes and removal of sludge to a distance exc 1.5 Km and n.exc 5 Km out of MOD land complete all as specified and directed.
M&L for cleaning of blocked drain any depth by removing sludge/mud/debrises and flush with water and removal of sludge to a distance exc. 1.5Km and n.exc. 5Km out of MOD land complete all as specified and directed.
Disconnecting existing water storage tank of capacity exc 250 ltr but n exc 500 ltrs, setting aside including Cleaning and removing all scale and dirt, etc, from tanks exc 250 ltr n.exc 500 ltr capacity and refixing in same position complete all as specified and directed.
All as item No. 25 above but cap exc 500 ltr and n. exc 1000 ltrs complete all as specified and directed.
All as item No. 25 above but cap exc 1000 ltr and n. exc 2000 ltrs complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed.
Taking down cement plaster of any description on brick work or stone masonry walls including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for brick work with sub class "B" old size bricks straight or curved on plan exc 6 m mean radius built in CM (1:6) complete all as specified and directed.
All as item No. 30 above but except Brick work only in CM (1:6) complete all as specified and directed.
M&L for 15mm thick plaster in CM (1:4) on fair face of brick walls finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick plaster in CM (1:4) mixed with WPC as per manufacturer's instructions on fair face of brick walls finished even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid seperately)
Supply only liquid water proofing compound (ISI marked) complete all as specified and directed.
M&L two coats of cement based paint over a coat of primer to newly plastered surfaces of wall including preparation surfaces complete all as specified and directed.
Demolition of cement concrete of any descriptionand in any position not oterwise specially provided complete all as specified and directed.
M&L PCC (1:3:6) type C-2 (using 40 mm graded crushed stone agreegate) as in sub base 75 mm thick complete all as specified and directed.
M&L for Chequered cement concrete rubber molded tiles of size 30cm x 30cm x 25mm thick with grey cement and pigment set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floor over and including screed bed of 15 mm thick in CM (1:6) complete all as specified and directed.
S&F in repair PVC (SWR) pipe 75mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and fixed to wall complete all as specified and directed.
S&F in repair PVC (SWR) pipe 110mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and fixed to wall complete all as specified and directed.
S&F in repair PVC (SWR) bend 110mm dia, any radius as required and jointed with approved adhesive complete all as specified and directed.
S&F in repair PVC (SWR) bend with access door 75mm dia, any radius as required and jointed with approved adhesive complete all as specified and directed.
S&F in repair PVC (SWR) bend 75mm dia, any radius as required and jointed with approved adhesive complete all as specified and directed.
S&F in repair 75mm dia PVC junction single (single T) equal or unequal with access door, jointed with approved adhesive complete all as specified and directed.
S&F stack clamp out of 50mm x 5mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to wall and roof for 75mm dia bore pipe complete all as specified and directed.
S&F stack clamp out of 50mm x 5mm flat iron and 16 mm dia round iron stays incl bolts and nuts and securing ends of stays to wall and roof for 100mm dia bore pipe complete all as specified and directed.
S&F in repair PVC (SWR) vent cowl 75mm dia, any radius as required and jointed with approved adhesive complete all as specified and directed.
S&F in repair vitreous China wash down (EWC) water closet pan (pedestal pattern), white (excluding flushing cistern and flush pipe) but including seat cover for pedestal pattern complete all as specified and directed. (Make : Jaquar/Cera/Hindware as approved by GE).
S&F in repairs china water closet Orissa Pattern 580 x 440mm white with integral foot rest (excluding flushing cistern anfd flush pipe) with PVC 'S' trap including provn of cement concrete bedding including connections to flushing cistern/pipe and making good disturbed portion to match existing surfaces complete all as specified and directed.
S&F in repair PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action push type with inlet ball valve and float including flush pipe long 32mm dia, ball valve, handle, bracket etc. complete all as specified and directed.
S&F in repair rotational moulded polythylene water storage tank three layered cylinderical, verticle with closed top hoisted and fixed in position tank capacity 500 Ltr with connection for inlet and outlet including 20mm PTMT float valve complete all as specified and directed.
M&L PCC (1:3:6) type C-2 (using 40mm graded crushed stone agg ) as in surface channel and drains complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block as in road berm any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade with pigments over and including 50mm thick sand cushioning complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise described complete all as specified and directed.
Dismantling of fencing post or struts(wood, steel or RCC) of any description including taking down out embeded portion and making good disturb ground complete all as specified and directed.
Excavating in post holes (or similar holes) in hard/dense soil each n.exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, complete all as specified and directed.
M&L Cement concrete type C2 (1:3:6) (40mm graded crushed stone aggregate) as in foundations, post hole, filling and mass concrete etc complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, copings, benching, holdfast and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framed work and similar works conforming to Fe-290 Gd E-165 complete all as specified and directed.
M&L for two coats of synthetic enamel paint over one coat of red oxide primer on new steel surfaces of any description, not otherwise described, over 10cm width or girth including preparation of new surfaces complete all as specified and directed.
S&F angle iron post or struts in fencing including cutting top to shape as directed drilling holes, notching for wire, etc flat iron fillets(for securing wire mess etc ) including all necessary drilling, bolting or riveting, etc and simillar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F galvanised, 2 strand steel barbed wire 2.24mm dia barbed with 2.00mm dia barbs at 75mm spacings, straining & fixing to any type of standard rails staining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc (each line wire to be measured) as in wire entanglements aprons, barriers, gates, etc. complete all as specified and directed.
M&L for Removal of demolished materials to a distance exceeding 500 Mtr but not exceeding 1500 Mtr and deposting where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed.
S&F welded steel wire fabric weight n exc 4 Kg per square metre fixed complete to steel member complete all as specified and directed.
S&F in repair PVC water tank covers screw head type including four Nos of PVC nut and bolt in existing PVC water tanks of Cap 500 ltrs to 1000 ltrs cap with fixing arrangement complete all as specified and directed.
S&F in repair Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe & waste pipe) complete all as specified and directed.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
BRICKS ON CLOUD INFRA
Bharat Bhoomi Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .