| Sl No | Description | Qty | Unit | B5BUILDING SOLUTIONS L2 | Phejays Agencies L4 | WELTRONENGINEERINGSERVICES L3 | ELAN ENGINEERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Material and Labour for filteration of transformer oil of different capacity/Rating to remove moisture , sludge,carbon particles and to achieve the dielectric strength / repturing capacity of oil not less than 50 KV/ minute with 2.5 mm gap and topping up of oil to the required level of transformer indicator level complete all as specified and as directed .
Note: 1)Topping up of transformer oil shall be measured and paid separately
(2) Contractor has to make his own arrangement for oil filtration plant and it's electric supply.
3)Contractor should take shutdown and filtration should be done in offline only . | 4,000 | LITRE | 13 ₹52,000 | 12 ₹48,000 | 18.99 ₹75,960 | 15 ₹60,000 |
| 2.00 | Material and Labour for topping up oil for transformer of 11KV/433 Volt of different capacity / HT oil switch of 11 KV of different capacity of any rating of dielectric strength /repturing capacity of oil not less than 50 KV ( tested at site with testing kit with 2.5 mm gap ) and test the the dielectric strength of transformer oil before and after the topping up and make oil to the required level of transformer indicator level all as specified and directed by Engineer-In-Charge.
Note: 1)The transformer oil container shall be ISI marked and brought at site in sealed container only.
2) The Material and Labour for necessary T & P for collection of transformerr oil samples , testing kit and filteration plant is inclusive in rate quoted | 300 | LITRE | 240 ₹72,000 | 200 ₹60,000 | 269.99 ₹80,997 | 250 ₹75,000 |
| 3.00Supply and Fix breather for transformer oil conservator tank including filled with silica gel for transformer of following ratings complete all as specified and as directed. | |||||||
| 3.01 | 315 to 500 KVA | 5 | EACH | 3,300 ₹16,500 | 1,500 ₹7,500 | 1,999.99 ₹9,999.95 | 1,700 ₹8,500 |
| 3.02 | 1000 KVA | 2 | EACH | 6,000 ₹12,000 | 3,000 ₹6,000 | 4,325 ₹8,650 | 4,000 ₹8,000 |
| 3.03 | 1600 KVA | 2 | EACH | 8,500 ₹17,000 | 4,000 ₹8,000 | 7,241 ₹14,482 | 6,000 ₹12,000 |
| 4.00 | Supply and Fix in replacement of Silica Gel (Moisture absorbent chemical ) for breather of transformer 11 KV /433 Volt of any make / rating complete all as specified and as directed. | 5 | KILO GRAM | 300 ₹1,500 | 600 ₹3,000 | 444 ₹2,220 | 400 ₹2,000 |
| 5.00 | Supply and Fix in replacement of oil temperature indicator gauge suitable for transformer of capacity 11KV/433 Volt complete all as specified and as directed. | 2 | EACH | 3,000 ₹6,000 | 1,400 ₹2,800 | 1,998 ₹3,996 | 1,800 ₹3,600 |
| 6.00 | Material and Labour for drain cock ISI marked at the bottom of the main tank of transformer after drain out oil up to safe working level and changing of existing HT bushing with stud, seal etc complete all as specified and as directed . | 2 | EACH | 3,500 ₹7,000 | 1,200 ₹2,400 | 1,450.99 ₹2,901.98 | 2,000 ₹4,000 |
| 7.00 | Supply and Fix in replacement of HT bushings of transformer 11 KV/ 433 Volts including by disconnecting existng HT connection, drain out oil up to safe working level and changing of existing HT bushing with stud , seal etc complete all as specified and as directed . | 4 | EACH | 3,000 ₹12,000 | 750 ₹3,000 | 1,891 ₹7,564 | 2,000 ₹8,000 |
Updated dates
Tender Value
₹65 L
EMD Value
₹1.2 L
Closing Date
17 Nov 2025, 6:00 pmClosed
CHIEF ENGINEER RND SECUNDERABAD
CHIEF ENGINEER RND SECUNDERABAD PICKET OPP JUBILEE BUS STATION SECUNDERABAD 500003
REPAIR/MAINTENANCE TO HT/LT DISTRIBUTION SYSTEM SF6 CB, VCB, RMU SWITCHGEAR, ACB, CHANGE OVER PANELS, APFC PANELS, UG CABLES, FEEDER PILLAR BOX PANELS BOARDS, EARTHING AND PERIODICAL SERVICES TO TRANSFORMERS AND ITS CONNECTED ITEMS AT TECHNICAL AREA
2025_MES_732515_1
86138
Open Tender
Electrical and Maintenance Works
330 days
NPOL KOCHI
Class C
category b(ii)
7 documents required · 7 mandatory
₹1,000
ASSISTANT GARRISON ENGINEER I RND KOCHI
₹1.2 L
Yes
21 Jan 2026
25 Sept 2025
19 Nov 2025
25 Sept 2025
17 Nov 2025
3 Nov 2025
Amount
Material and Labour for filteration of transformer oil of different capacity/Rating to remove moisture , sludge,carbon particles and to achieve the dielectric strength / repturing capacity of oil not less than 50 KV/ minute with 2.5 mm gap and topping up of oil to the required level of transformer indicator level complete all as specified and as directed . Note: 1)Topping up of transformer oil shall be measured and paid separately (2) Contractor has to make his own arrangement for oil filtration plant and it's electric supply. 3)Contractor should take shutdown and filtration should be done in offline only .
Material and Labour for topping up oil for transformer of 11KV/433 Volt of different capacity / HT oil switch of 11 KV of different capacity of any rating of dielectric strength /repturing capacity of oil not less than 50 KV ( tested at site with testing kit with 2.5 mm gap ) and test the the dielectric strength of transformer oil before and after the topping up and make oil to the required level of transformer indicator level all as specified and directed by Engineer-In-Charge. Note: 1)The transformer oil container shall be ISI marked and brought at site in sealed container only. 2) The Material and Labour for necessary T & P for collection of transformerr oil samples , testing kit and filteration plant is inclusive in rate quoted
Supply and Fix breather for transformer oil conservator tank including filled with silica gel for transformer of following ratings complete all as specified and as directed.
315 to 500 KVA
Supply and Fix in replacement of Silica Gel (Moisture absorbent chemical ) for breather of transformer 11 KV /433 Volt of any make / rating complete all as specified and as directed.
Supply and Fix in replacement of oil temperature indicator gauge suitable for transformer of capacity 11KV/433 Volt complete all as specified and as directed.
Material and Labour for drain cock ISI marked at the bottom of the main tank of transformer after drain out oil up to safe working level and changing of existing HT bushing with stud, seal etc complete all as specified and as directed .
Supply and Fix in replacement of HT bushings of transformer 11 KV/ 433 Volts including by disconnecting existng HT connection, drain out oil up to safe working level and changing of existing HT bushing with stud , seal etc complete all as specified and as directed .
Supply and fix in replacement of LT stud of suitable size for transformer of 11/0.433 Volt for following rating and complete all as specified and as directed.
315 to 500 KVA
Material and labour for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT of size 25X20 cm, complete all as specified and as directed .
Material and Labour for dismantling the distribution Transformer 11/0.433 KV Oil Cooled copper wound of follwoing capacity from installed position on existing platform after disconnecting electric supply from HV and LV sides on site for necessary repairs like replacement of washers, replacement of sleeves, taps, kerb tapes, cork sheet, refilling of oil, etc after checking and make fully functional the Winding Temparature Indicator (WTI) and Oil Temparature Indicator (OTI) including replacement of unserviceable item (if required) as directed and installing in its original position and making all electric connections with thimble & PG clamps, commissioning including refilling of transformer oil after dehydration with dielectric strength (min 60 KV) and testing complete all as specified and as directed.
Notes : (i) Labour component required for the replacement of unserviceable parts shall be deemed to be included in the unit rate quoted against this item. (ii) HT/LT bushes, breather assembly, Transformer oil shall be measured & paid separately under relevant item. (iii) T&P and minor parts will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item. (iv) Filteration and topping up of transformer oil shall be measured and paid under respective items in shedule if necessary after checking the breakdown value of oil.
Dismantling GI earth wire or cradle guarding or GI anti climbing device etc. and serviceable materials keep in safe custody for reuse and unserviceable materials removing from the site complete all as specified and as directed.
Material and Labour for galvanised steel continuous wire 4mm dia complete all as specified and as directed.
Dismantling cross arms, MS channel or angle sections etc. complete and unserviceable removing from the site complete all as specified and as directed.
Material and Labour for cross arms, bracings, support clamps and back plates fabricated from structural steel section including nut bolts washer, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and as directed.
Material and Labour for preparation of old painted rusted LT cross arms ,bracings ,supports, clamps and back plate fabricated from structural steel sections including nuts bolts washers etc and Steel poles providing two coats of aluminum paint including numbering and making strips in circular shape of diameter 150mm black colour letter of height 50mm not exceeding 150 mm up to 1.5 mtr above ground level with alternative layer of yellow and black paint complete all as specified and as directed.
Dismantling HT/ LT stay assembly complete including MS clamps with bolts, nuts & washers etc along with necessary excavation and earth work, demolition of cement concrete and removing from thr site necessary excavation & earth work complete all as specified and as directed.
Material and Labour for stay assembly complete with accessories such as mild steel glavanised flat iron stay clamp, 7/3.15 mild steel galvanised stay strand/wire, one loop type porcelain vitreous insulator (white , brown or green) over all dimentions 65X90 mm & clearing hole 16 mm, stay grips, mild steel galvinsed stay bow, thimbles, 16 mm dia diameter of stay rod shown in electrical plate No 1 of MES SSR Part- I complete all as specified and as directed. (Note : Excavation & earthwork, cement concrete measured and paid separately relevant items of this schedule).
Dismantling of ACSR or AAC conductor squirrel type from poles of any size & capacity and unserviceable materials removing from the site complete all as specified and as directed.
Material and Labour for ACSR conductor squirrel type any size as approved on HT/ LT Poles including stringing, binding to insulators with aluminium binding wire with connectors, etc providing PVC sleeves for jumpers as in OH conductors complete all as specified and as directed.
Re-Streching, tightening and fixing the ACSR conductor of any size on LT poles including necessary aluminium binding wire connectors/spacer etc, without taking down the conductors complete all as specified and as directed.
Dismantling insulators or shackle of LT of any type and size from poles and unserviceable insulators removed from the site complete all as specified and as directed.
Supply and Fix in repair pin type insulator porcelain vitrous, white, brown or green including one galvanised mild steels spindle two galvanised iron washers and one galvanised iron nut 100 mm height 65 mm dia for 1100 volt grade complete all as specified and as directed.
Supply and Fix in repair shackle type porcelain, vitrous white brown or green insulator including GI/MS straps of size 31x3mm, 12mm dia insulator bolts nuts and washer for working pressure 1100 volts of size 75mm height 90mm dia complete all as specified and as directed.
Dismantling of Unserviceable Pre-stressed concrete poles/ steel poles of any size and shape including necessary excavation and earth work, taking out of embedded portion of poles from concrete after necessary demolition of cement concrete foundation and disposal of same complete all as specified and as directed. Note : Exacvation and earthwork, returning filling removing of surplus soil and demolition of concrete and disposed of the demolished concrete shall deemed to be included in the unit rate quoted by the tenderer.
Supply, erecting and fixing steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts & screws as specified type 410 SP - 31 ( 9.00 metres long), complete all as specified and as directed. Note : (i) Earthwork, cement concrete, etc. will be measured and paid separately under relevant items of this schedule . (ii) Excavation and earth work shall only be measured in case location is other than item No. 24 (iii) Painting to steel tubular poles (inside and outside) is included in the rates of steel tubular poles.
Replacement of PVC Zig Zag LT Line spacer/separator for LT over head ACSR conductor of any size without taking down the conductors complete all as specified and as directed.
Material and Labour in repair for HT danger notice and station name board readymade / printed on water proof sheet with White letters blue radium background , MES logo , conventional skull and bones in signal red colour and supporting channels of Approved size up to 1.5 X 1 m, complete all as specified and as directed. Note:-excavation and concrete work shall be measured and paid separately .
Dismantling and Rewinding of the distribution Transformer 11/0.433 KV Oil Cooled copper wound of 400 KVA capacity from installed position on existing platform after disconnecting electric supply from HV and LV sides on site and take it to the workshop Preliminary Inspection, Diagnosing the fault. Service charge for oil draining, transformer top cover removing, bush stem dismantling, removing of core coil assembly, job cleaning, dismantling of CCA, coil winding, re fixing of CCA, Terminal Gear Cutting & Rejoining charges, Tanking, and all other jobs & filteringpairs like replacement of washers, replacement of sleeves, taps, kerb tapes, cork sheet, refilling of oil, etc after checking and make fully functional the Winding Temparature Indicator (WTI) and
Oil Temparature Indicator (OTI) including replacement of unserviceable item (if required) as directed and installing in its original position and making all electric connections with thimble & PG clamps, commissioning including refilling of transformer oil after dehydration with dielectric strength (min 60 KV) and testing, complete all as specified and as directed.
Transformer capacity upto 400 KVA
Transformer capacity upto 1000 KVA
Transformer capacity upto1600 KVA
Material and Labour for laying 40 mm aggregate in substation yard to protect from touch potential Hard core, broken to gauge n exc 63, complete all as specified and as directed.
Material and Labour for Maintenance of HT/LT VCB/ACB of rating from 400 Amp to 3600 Amp 415 Volt 50 HZ of any make installed at substation/MRS at NPOL complete by taking the shut down with prior intimation Cleaning of panel by removing dust ,check the snatch gap,check the travel,check the tightness of contacts,check the entire mechanisam operation and replacing of damaged spares during the service.check the condition of closing and tripping spring ,check the VCB racking mechanism,apply lubrication where ever required, complete all as specified and as directed. Note: (i) Unit rate include for preventive maintenance / attending break down as and when required.Relay calibration and setting as per load condition. (ii) The work shall be carried out through OEM / OEM authorised vendor.
(iii) Rate Quoted deemed to be including cost of replacing small piece of control circuit wires up to 1.00 Mtrs , LT fuses and Push buttons for ON/Off if required . (iv) Contractor should attend the complaint on call basis on emergency . Condut the following test to ensure the panel work properly. (a) IR Test with 5 KV IR Testor (b) Contact Resistance Test (CRM) (c ) 3Pole Timing (d) Checking the servicebilty of control circuit , relays ,fuses and Electrical /Mechanical interlocks. (e)Replacing the spares such as Shunt release , UV release ,tripping/Closing coil shall be measured and paid separately under respective item.
Material and Labour for the preventive maintenance of schneider make CCT2 RMU as per schedule below, complete all as specified and as directed. 1.Checking jand cleaning of termination boot&bushings and cable compartments . 2.Visual inspection of RMU (including SF6 level)and opening of gland plate area. 3.checking of batteries ,relays ,FPI and RMU. 4.Inspect control wiring for continuity. 5.Checking of mechanical interlocks and latches . 6.Operate the RMU minimum 3 times manually& electrically. 7.Lubricate the mechanism portion. 8.Checking IR with 5 KV IR testor. Note : The work shall be carried out through OEM / OEM authorised vendor.
Material and Labour for attending emergency breakdown in substation Maintenance of HT/LT VCB/ACB of rating from 400 Amp to 3600 Amp 415 Volt 50 HZ of any make installed at substation/MRS at NPOL complete by taking the shut down with prior intimation and cleaning the HT/LT VCB/ACB by using air blower tightening of connection of control circuit and complete checking of all fuses, checking relay and control circuit for smooth functioning by employing one skilled tradesman as and when required and also to carry out following works, complete all as specified and as deirected . Note: (i) Unit rate include for preventive maintenance / attending break down as and when required. (ii) The work shall be carried out through OEM / OEM authorised vendor.
Supply and fix in replacement shunt release for LT ACB 415/240 Volt AC up to 3600 Amp as per existing, complete all as specified and as directed.
Supply and fix in replacement under voltage release 415/230 Volt suitable for LT ACB of rating up to 630 Amp as per existing, complete all as specified and as directed.
Supply and fix in replacement Volt meter 0-500 Volt digital type, Three phase of size 96 X 96 mm flush mounted case in existing panel including wiring from bus bar to volt meter terminals so as to match with the existing control wiring complete all as specified and as directed.
Supply and fix in replacement digital Ammeter of size 96 X 96 mm flush mounted of range from 50 Amp to 3500 Amp , three phase connected from CT ratio -/ 5 A in existing panel with necessary wiring from CT to Ammeter and so as to match with existing control wiring complete all as specified and as directed .
Supply and fix in replacement current Transformer of following rating ,Indoor type, insulated ring type tape wound /resin cast in existing panel includintg taking down old unserviceble CT's of any make /rating complete all as specified and as directed .
CT ratio 200 /5 Amps .
CT ratio 500 /5 Amps .
CT ratio 1000 /5 Amps .
CT ratio 1500 /5 Amps .
CT ratio 2500 /5 Amps .
CT ratio 3000 /5 Amps .
Material and Labour for surface dressing to E/M installations /1.5 Mtrs from out side of fencing , E/M store yards of following area not exceeding 15 cm deep getting out soft / loose soil removing shrubs, small trees height up to 1.0 Mtrs, removing the grass from route and cleaning the fencing by removing small trees / vegitation on fencing complete all as specified and as directed. Note : (i) Rate includes removing all waste material and grass not exceeding 50 Mtrs distance from installation,depositing where directed at a level not exceeding 1.5 mtrs above the starting point and cleaning of yard.
Main Receiving substation of area 100 Sqm inside the Technical area.
Substaion no 02 ( MATS) of area 50 Sq m inside the Technical area
Substaion no 03 (Near Post office) of area 50 Sqm
Substaion no 04 ( At Site A ) of area of area 100 Sqm
Substaion no 05 (Site A near type IV/V Accn) of area 80 Sqm
Substaion no 06 (At Site ' B Near DREMI) of area 80 Sq m
Substaion no 07 ( At Site ' B Near Type III Accn Area) of area 80 Sq m
Substaion no 08/ T complex S/S ( At Site ' B ) of area 150 Sq m
Supply and Fix fire retardant insulated synthetic mat for 1100 Volt of 2.0 mm thick +/- 10% conforming to IS 15652:2006, tested for breakdown strength, ageing properties, insulation resistance, effect of acid,Alkaline, Diesel & transformer oil ,leakage current test,fire test etc having the width of 1000mm (+/-) 20mm complete as required sutable and using adhesive and alied chemical and scaling of all parts of all joints and border ends and fixing tape making good as paste near HT switch gear and transformer, complete all as specified and as directed.
Supply and Fix in replacement Capacitor duty contactors with auxiliary contacts of following capacity including dismatling the existing duty contactors of any rating/make and making connection to fuse links /MCB and capacitor bank complete alll as specified and as directed.
Capacitor duty contactor suitable for 50 KVAR
Capacitor duty contactor suitable for 25 KVAR
Capacitor duty contactor suitable for 20 KVAR
Capacitor duty contactor suitable for 15 KVAR
Capacitor duty contactor suitable for 12.5 KVAR
Capacitor duty contactor suitable for 5/8.5 KVAR
Supply and fix in replacement 8 - stage APFC relay with built in P.F Meter after dismantling the existing meter from APFC unit and programme the newly installed relay unit as per OEM instructions or in presence of OEM representative to match with existing arragement of capacitor banks complete all as specified and as directed. Note: Rate includes contractor has to check the APFC relay/panel after completion of work with different load condition, after disconnecting the existing supply connections to Relay panels complete.
Supply and Fix in replacement Capacitor banks, Cylindrical type Heavy duty of rating as required at site complete all as specified and as directed.
Supply and Fix in replacement LED type pilet lamp suitable for working voltage range up to 240 Volt AC complete all as specified and as directed.
Supply and Fix in replacement on load change over switch of 630 Amp , 4 pole in existing panel with necessary modification in bus bar arrangement if required complete as specified and as directed.
Material and Labour for wiring from CT's inserted in Incomming Switch gear/Bus Bar for sensing the instantanious power factor to APFC relay with two run 2.5 Sq mm PVC insulated FR conductor passing through PVC conduit not less than 20 mm dia surface type fixed on wall/Panel with necessary saddles and fixing arrangments comple all as specified and as directed.
Material and Labour for removing and replacement of porcelain busbar supporter (Approx 200 Nos) with new as of same size, including removing and replacement of deterioted SS Screws (Aprox 250 Nos, 1½ inch or 2 inch) SS bolts, nuts and washers (Approx 200 Nos) etc in the existing Galvanised Iron/copper strip of any size upto the end connected to equipment complete all as specified and as directed.
Supply and Fix in repair spring charging motor suitable for existing 11 KV VCB complete all as specified and as directed.
Supply and Fix in repair vacuum Interrupter cylindrical type suitable for 11 KV VCB complete all as specified and as directed.
Supply and Fix in repair DC power pack 24 Volt, 22 AH supply built with battery and auto battery charger complete all as specified and as directed.
Material and Labour for XLPE insulated, screened , PVC bedded, galvanised steel strip or wire armoured, electric power cables (Heavy duty) with aluminium conductor, 11000 Volts (Earthed) grade cross sectional area 120 Sq mm 3 core in trenches/fixed on wall with supporting insulator/saddles etc, complete all as specified and as directed.
Lifting and laying HT UG cable of any size up to 120 Sqmm complete all as specified and as directed. Note : Excavation/PCC and sand cushioning shall be measured and paid separatley.
Lifting the existing precast cement concrete cable cover and laying the same covers, in trenches for cable protection, complete all as specified and as directed.
Material and Labour for laying XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 Volts grade, in trenches/fixed on wall with supporting insulators/saddles etc for following size complete all as specified and as directed.
400 sqmm 3.5 core
150 sqmm 3.5 core
120 sqmm 3.5 core
95 sqmm 3.5 core
70 Sq mm 3.5 Core
50 Sq mm 3.5 Core
35 Sqmm 3.5 Core
25 Sq mm 3.5 Core
10 Sq mm 4 Core
Supply and Fix in repair for heat shrinkable HT, 11 KV , outdoor type, cable end joint suitable for 11 KV, 3 Phase, AC, 50 Hz, , XLPE cable including jointing materials including taking down old end joints complete all as specified and as directed for following size.
50-95 Sqmm 3 core
120-185 Sqmm 3 core
Supply and Fix in repair of heat shrinkable HT, 11 KV , indoor type, cable end joint suitable for 11 KV, 3 Phase, AC, 50 Hz, , XLPE Cable including jointing materials complete including taking down old end joints cpomplete all as specified and as directed for following size.
120-185 Sqmm 3 core
Supply and Fix in repair of cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 Sqmm to 185 Sq mm complete all as specified and as directed .
Hiring of HT UG Cable fault locator from authorised agency to find the exact location of the fault , complete all as specified and as directed. Note:- (a) Transportation of instrument is contractor responsibility.
Supply and Fix in repair for heat shrinkable LT, 1100 volt grade, outdoor type, cable end joint suitable for 1100 Volt grade, 3 Phase, AC, 50 Hz, , XLPE Cable including jointing materials complete including taking down old end joints all as specified and as directed for following size.
10-35 sq mm 3.5 core
50-120 sq mm 3.5 core
150-240 Sq.mm 3.5 core
300-400 Sq.mm 3.5 core
Excavation in trenches not exceeding 1.5 mtr deep and 1.5 mtr width as in Hard dense soil complete all as specified and as directed. Note: NO JCB Excavation is permitted for earth work.
Returning filling including levelling watering and well ramming in layer not exceeding 25 cm thick complete all as specified and as directed.
Removing excavated soil of surface soil to a distance n.exc 50 m and deposited where directed at a level n. exc 1.5 m above the starting point complete all as specified and as directed.
Supply and laying riddled earth /sand for cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable complete all as specified and directed. ( Note: Punned thickness shall be taken for measurement)
Material and Labour for laying un-reinforced precast concrete cable cover, class HVP, type -1 with peack size 300 mm x 180 mm x 40 mm (ISI marked) complete all as specified and as directed .
Material and Labour for laying LV unreinforced precast concrete cable cover but Type 2, flat, size 300mm x 180mm x 40mm (ISI marked) complete all as specified and as directed.
Material and Labour for road cutting /removing the hard Standing/Cutting floor inside the Substaion /E/M Installtions / Path for laying of cables of any size complete all as specified and as directed.
Material and Labour for PCC 1:4:8 type D2 40 mm graded aggregate and making good to the excvated portion of Road/Hard Standing at road crossing etc , complete all as specified and as directed.
Supply and fix in repair water proof junction box made from SMC sheet ready made of size 155 x 210 x 92 mm with aluminium bus bar of 150 Amp capacity for RYB and neutral fixed inside the junction box with necessary supporting insulators fixed on hylem sheet /Insulating sheet ,MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete , entire assembly fixed to pole /Wall with MS clamp 25 X 5 mm and nuts & bolts, and connecting cables from junction box to fittings complete all as specified and as directed .
Material and Labour for HT cable route indicator for under ground cable indication complete all as specified and as directed.
Material and Labour for LT cable route indicator for under ground cable indication complete all as specified and as directed.
Supply and lay GI tubing light grade in trenches / fixed on wall with necessary fittings such as bend, tee,elbow etc for the following sizes. Complete all as specified and as directed.
80 mm size.
50 mm size.
40 mm size.
Supply and lay double wall corrugated (DWC) HDPE pipe 63mm bore, as per IS-14930 including couplers and bend for cable protection laid in trenches etc complete all as specified and as directed .
Supply and fixing in replacement MCCB of following ratings in existing indoor/ Outdoor HT/LT panel board including connecting with proper size link set at incoming and outgoing cable connections and making necessary modification in existing panel as required complete all as specified and as directed. Note: cost includes taking down the existing MCCB from panel board, disconnecting incoming / outgoing cable and fix the new MCCB in position at panel board including necessary cable connections of any size/ rating.
MCCB 63 to 100 Amp 4 pole 16 KA.
MCCB 125 Amp 4 pole 36 KA.
MCCB 125 Amp 3 pole 16 KA.
MCCB 200 Amp 4 pole 36 KA.
MCCB 200 Amp 3 pole 36 KA
MCCB 250 Amp 4 pole 36 KA
MCCB 400 Amp 4 pole 35/36 KA
Supply and fix in replacement MCB of following rating , 50 Hz AC Supply 10 KA with necessary aluminium lugs up to 16 Sq mm complete all as specified and as directed .
MCB TPN 4 Pole 32-40 Amp.
MCB TPN 4 Pole 63 Amp.
MCB TPN 4 pole 100-125 Amp.
Supply and fix in replacement MCB 240 V 50 Hz AC 10 KA , of follwing rating with necessary lugs for incomming and outgong connections fixed on DB / Enclosure /Panel Boards after taking down the existing MCB, complete all as specified and as directed.
MCB SP 6 to 32 Amp, 'C' curve.
MCB DP 32 Amp, 'C' Curve
Supply and fix ELCB 40-100 MA , 4 Pole ,10 KA, 'C' Curve complete all as specified and as directed.
Supply and fix MCB DB TPN 4 way IP 43 protection ,double door , concealed on wall and making good to disturbed surface so as to match with existing, complete all as specified and as directed
Supply and Fix vertical double door,TPN DB 8 way with modular incommer surface /wall mounting IP-54 metal door protection with provision for 3 pole and 4 pole MCCB as incommer and SP/TP MCB as outgoing with and including MCCB 125 AMPS 4 pole, complete all as specified and as directed.
Supply and Fix VTPN DB withMCCB incommer ,Metal double door,415 V, three phase,6 way ready to use DBs provided with Neutral Bar, Mechanical Impact Strenth IK 09 , Insulated busbar assembly, cement spill protector, color-coded interconnecting wire set, cable ties blanking plates and circuits identification labels suitable for MCCB's upto 125Amp as I/C (Frame 1) and MCBs (TP/DP/SP) as outgoing, IP 43 protection, module optimum F2+6+6+6, conforming to IS 8623-1 & 3, IEC 61439-1 & 3 including connection of incomming and out going cables using suitable size lugs and glands complete all as specified and as directed.
Material and Labour for cleaning the LT feeder pillar box indoor/ Outdoor type of size up to 3m X2m X0.5m of different rating bus bar, after dismantling the Incoming and outgoing connections from MCCB/ Bus bar and replacing the old unserviceable nut, bolts, supporting insulators etc. and check the serviceability of MCB/MCCB, earth continuity conductor, tightening the earth conductor and incoming and outgoing cables and removing existing old insulation of bus bar and MCCB/ MCB terminals and providing new insulation tape of standard quality applied to Bus bar and MCCB terminals and cleaning the feeder pillar box complete all as specified and directed.
Supply and Fix in repair LED indicators (colours red/ yellow/ blue/ white/ green) complete all as specified and as directed.
Supplly of LT cable lugs and replace with rusted and damaged lugs with proper connection complete all as specified and as directed.
Supply nuts and bolts for fixing end terminals of LT cables remove rusted nutbolts with suitable size complete all as specified and as directed.
Material and Labour for painting of Feeder pillar box with anti corrosion two coats of synthetic enemel paint over one coat of red oxide primer, complete all as specified and as directed .
Material and Labour for writing feeder pillar No on feeder pillar with super enamelled synthetic paint of size 75x75 mm height 75mm with black back ground surface, complete all as specified and as directed .
Supply WD 40 for rust cleaner for removing rusted nut bolts, complete all as specified and as directed. Note: nut bolts paid separatly .
Supply CRC 2-26 Power Spray Cleaning Electro With 2 Spray Technology complete all as specified and as directed.
Repair of 6 KVA / 4.8 KW 120 VDC online UPS 30 Minutes Back up version Technology, pure sine wave, LCD display, , Crest factor 3:1 with Protection of Out put over voltage/ Under voltage and over load with in built Galvanic Isolation complete all as specified and as directed .
Supply and Fixing of 26 AH fast recharging sealed maintenance free (SMF) Heavy duty alloy construction Battery for incommer VCB control power backup batteries . Complete all as specified and as directed .
Supply and Fixing of 12 AH fast recharging sealed maintenance free (SMF) Heavy duty alloy construction Battery for RMU Control wiring for auto charge .Complete all as specified and as directed .
Material and Labour for cable duct cover of steel plate, 6 mm thickness cut in required size including painting applying two coats of priming with red oxide Zinc chrome and a final coat of black japan paint by spray paint ( Using Machine) at both sides i.e., top and bottom of cable duct cover, complete all as specified and as directed.
Replacement of outdoor type LT Feeder pillar box made out of 3.0 mm thick CRCA sheet outdoor type, CPRI Approved, totally enclosed weather dust and vermin proof as per IS with front and rear 300 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary made out of 50 X 50 X 6 mm angle iron grouted at Floor above 30 cm from ground level Comprising the following including taking down old unserviceable feeder pillar box, complete all as specified and as directed . Note: (i) Cost includes necessary internal wiring for meters , CTs, indication lamps, etc and Rigid bus bar connections from bus bar to MCCB terminals connection Bus to MCCB/MCB connections.
(ii) Connection from HT Switch gears (Ringmain system) to new LT feeder pillar box to be done and necessary fitting fixtures to be borne by the contractor without extra cost to the department. Incoming (i) Provision of MCCB 400 Amp 4 pole (ii) Digital multifunction meter, class 1 - 1 no (iii) LED type Indicating lamps -03 Nos Outgoing (i) Provision of MCCB 200 Amp 4 pole 25 KA - 01 Nos (ii) Provision of MCCB 100 Amp 4 pole 25 KA - 03 Nos (iii) Provision of MCCB 63 Amp 4 pole 16 KA - 1Nos
Material and Labour for cutting the tree branches at a distance not exceeding 2.0 Mtrs away from LT distribution lines , of tree branch size up to 50 mm dia and deposited the removing branches at a distance not exceeding 50 Mtrs from Road /Path, complete all as specified and as directed. Note: Each pole locations / Distance between Two poles of Distance maximum up to 30 Mtrs is considred as One job irrespective of number of tree branches for cutting tree branches for over head lines .
Material and Labour for Earthing complete with galvanized steel earth plate electrode 600x600x6.0mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron strip 32x6 .00 mm as earthing by means of bolts nuts and washers of galvanized iron including excavation and earth work and disposal of surplus soil including 40 mm GI tubing light grade and necessary fittings for protection of GI strip including laying of charcoal , dust and common slat , PCC 1:2: 4 type B 1 using 20 mm graded aggregate with earth pit with 40 X 40 X 6.0 mm MS angle iron frame RCC cover 40 mm thick (1:2: 4) type C1 using 20 mm graded stone aggregate reinforced with 8 mm dia round
bar @ 75 mm C/C both way with plastering 15 mm thick CM ( 1: 6) internally and up to 150 mm below ground level externally . PGI funnel with wire mesh ,20 mm dia medium grade GI pipe for watering complete all as shown on electrical plate No : 03 of SSR part - I 2009 and connected to earth test point including testing complete all as specified and as directed. Note:- (i) RCC pit cover shall be precast of RCC 1:2:4 type B-1, 80mm thick reinforcement with 8mm TMT steel bar @ 100 c/c in lieu of CI cover and the rate includes in the unit rate of item.
(ii) Earth electrodes shall be protected upto test point using necessary arrangement with suitable size GI pipe upto 7.50m and the rate includes in the unit rate of item. (iii) The earth chamber shall be constructed min 3m away from the edge of the bldg pit and the cost of the same is deemed to be included in the rate quoted for this item. (iv) If the earth resistance value turned out to be unsatisfactory upon testing, the contractor has to re do the earthing at free of cost.
Supplying and Fixing in replacement earth continuity conductor or main earthing lead of Galvanised iron strip of size 32 X 6 mm, fixed on Floor/ Wall with supporting insulators / laid in trench from existing earth test point complete all as specified and as directed .
Material and Labour for Earthing complete with galvanised steel earth plate electrode 60X60cmX6.0 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 25x4 mm GI strip means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrial plate No. 5 connected or indicated including testing on completion. Including necessary excavation,earth work,pcc pit, RCC cover ,funnel with watering pipe 20mm bore light grade,GI protection pipe 40 mm bore light grade complete all as specified and as directed . Note: No JCB excavation permitted inside the E/M installation
Supplying and Fixing in repairs earth continuity conductor or main earthing lead of Galvanised iron strip of size 25 X 4 mm, fixed on pole from existing earth test point complete all as specified and as directed.
All as per item no 97 above, but for copper plate 60× 60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead.
Material and Labour for providing copper strips of size 20x3mm from test point/ panel/DB body to earth pit above /under ground complete all as specified and as directed.
Material and Labour for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanised iron wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, as shown in electrical plate No.3 connected to earthing test point including testing on completion. Complete all as specified and as directed.
Material and Labour for painting of Earth pit chamber with cement base paint one coat suitable for outdoor including cleaning of Earth pit surrounding and write earth resistance value and test date on earth pit with green background letters with white paint complete all as specified and as directed .
Supply and Fix test links box PVC Surface mounting ,colour coated ,rectangular shape with 5mm thikness complete all as specified and as directed
Supply and Fix DMC insulators for supporting GI strip and copper strip complete all as specified and as directed
B5BUILDING SOLUTIONS (BID ID -3471575)
WELTRONENGINEERINGSERVICES (BID ID -3476443)
Phejays Agencies (BID ID -3476116)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.54 MB
86138Tender.pdf
Tender Documents • 1.31 MB
BOQ_820167.xls
BOQ • 1.61 MB
Download all tender documents and submit your bid