Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹22.6 L+₹4.2 L (23.1%)Rejected-AOC GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L2 | Rejected-AOC NOT LOWEST |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
18 Dec 2021, 6:00 pmClosed
CWE(HILLS) DEHRADUN
Headquarters Commander Works Engineers (Hills) Military Engineer Services, Mall Road, Dehradun Cantt
SPECIAL REPAIR TO BLDG NO DS 16 OR MARRIED ACCN AT GRRC LANSDOWNE.
2021_MES_485587_2
87077/LDN/E8
Open Tender
Civil Works
Item Rate
150 days
AGE(I) Lansdowne
Class E cat a i
6 documents required · 6 mandatory
₹500
AGE(I) Lansdowne
₹48,000
Yes
30 Dec 2021
1 Dec 2021
20 Dec 2021
1 Dec 2021
18 Dec 2021
6 Dec 2021
1 Dec 2021 - 3 Dec 2021
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ -150) as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as Specified & directed by GE/Eng-in-Charge.Make - Tata Durashine , JSW Colouron+ or equivalent in Roffit( Shiv Shakti Fibre Udyog)
M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ- 150) as in ridges, hips, valleys/rain water / roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.Make - Tata Durashine , JSW Colouron+ or equivalent in Roffit( Shiv Shakti Fibre Udyog)
Dismantling timber scantling 40 sqcm and over in section,in any position, any description complete all as specified and directed.
M & L for 2nd class softwood in timber scantling for wall panelling, ceiling, roof truss,post, purlins, rafters and similar work (Clean sawn Timber framed and fixed type) including necessary coating framed joints with glue, complete all as specified and directed.
Dismantling of timber scantling in fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section in any description complete all as specified and directed.
S & F 2nd class hard wooden fillets (SAL) square or rectangular or triangular in section wrought fixed to wall with screw area exc 13 but n. exc 25 sq cm complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
M & L for 2nd class soft wood boarding 20 mm thick planed one side, rebeted or fixed with screw, fixed to timber frame work with nails complete all as specified and directed. .
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc and including removing unserviceable material,outside of A 1 defence land complete all as specified and directed.
Material & labour for Rendering 10 mm thick CM 1:6 on brick or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
M & L for Rendering 15 mm thick in two layers i.e. 10mm thick in CM 1:6 and 5mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick or concrete surfaces and finishing surfaces even & smooth without using extra cement complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
Material & labour for Rendering 5 mm thick CM 1:3 using water proofing liquid compound as per manufacturer's instructions on brick or concrete surfaces of ceiling /chajja's finished even & smooth without using extra cement complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
Supply only liquid water proofing compound.ISI marked complete all as specified and directed.
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equivalent in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- 1. The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE before application of distemper for each building. (v). The colour / shade will be all as approved by GE (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L for preparation of newly plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper The cost of all material T&P and labour required for preparation of surface are deemed to be included in the rates quoted . (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper using roller all as specified and prescribed by manufacturer of paint and all as directed at site by Engr-in-Charge . Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
M&L for Preparation of old wooden surfaces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint Ist quality after removal of existing treatment from old surface with help of thiner or other removing chemical materials complete all as specified and directed.
M & L for preparation of old steel surafces of any description over 10 cm width or girth & applying two caots of synthetic enamel paint Ist quality after removal of old existing treatments with help of thiner or other removing chemical materials complete all as specified and directed
M & L preparing of new plastered or un plastered surface of ceilings and applying two coats of white wash complete all as specified and directed.
Material & Labour for 300x300x 7 to 8mm thick:- Non-Skid light coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (Square/rectangular) area of each tiles exceeding 0.06 Sqm and not exc. 0.11 Sqm, in floor etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. including 15 mm thick screed bed in cm 1:6 including dismantling of existing old tile. complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE(I)
Material & Labour for 300X450X 8 to 9 mm thick joint free light coloured glazed ceramic tiles of any design and pattern, as in dado etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects. including 10 mm thick in cm (1:4) backing coat and including dismantling of old tiling and removing old unserviceable materials from the distance not exceeding 1.5 Km complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE(I) Lansdowne
Material & Labour for 400x400x 7 to 8mm thick Joint free Non-Skid light coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (Square/rectangular) area of each tiles exceeding 0.06 Sqm and not exc. 0.11 Sqm, in floor etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. including 15 mm thick screed bed in cm 1:6 including dismantling of existing old tile. complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE(I)
Supply & Fixied in repair ,tiled false ceiling of Everest tile (High Pressure Steam Cured) of 4mm thickness (as per IS:14862) of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gsm, both side inclusive and black painted groove on all T webs) consisting of main "T" runner with suitably spaced joints to get required length and 15x32 mm made from 0.30mm thick sheet, spaced at 1200 mm c/c and cross "T" of size 15x32mm made of 0.30mm sheet, 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 15x32mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 15x20x0.40 mm and laying false ceiling tiles in the grid including , required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanized Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15mm of all T -sections shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width,including making good all the disturbed portion with existing surface with necesary arrangemnets of scaffolding all complete at all heights as per direction of Engineer-in-charge.
Taking down Chowkats with shutter exceeding 1.5 sqm . but n . Exc 4sqm each (Without taking off shutters from the frames). complete all as specified and directed.
Taking down chowkats with shutter n. exc 1.5 sqm each. (without taking of shutter from the frame) .complete all as specified and directed.
Taking down shutter of any description exc. 1 sqm but n exc 2 sqm.complete all as specified and directed.
Taking down shutter of any description n. exc. 1 sqm complete all as specified and directed..
Providing and fixing windows & ventilators fabricated from Rolled Formed GI Section made of Galvanised steel colour coated(PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality. Galvanised as per IS 277 with Zinc of 90 Gsm/SqMt w. PAINT: Pre-Painted sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick.GI Section of 0.58mm thick in Double rebate windows in which both glazed shutter and flymesh shutter, 74 X 60mm outer frame , Mullion 72 x 49mm, Glazed shutter 48 x 22mm, Flymesh 41 x 22mm, Beading with round ends for Glass Fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters the sections cut to length metre joined with corner PolyVinylChloride brackets centre mullion fixed with PolyVinylChloride Mullion caps . Glass of 4mm thick plain float glass fitted with Ethylene Propylene Diamine Monomer in glazed shutter and wiremesh of Stainless steel of 36 guage to fix mesh in mesh shutter using VC Black Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with crca of zinc phosphate coat.Each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each, PolyVinylChloride handle 1 in each and Powder coated Peg stay in Glass shutter.Window shall be provided with Powder coated MS Grill/Guard Bars made of 10mm MS Sq Bar welded to 6 x 12mm MS Flat with countersunk holes at both vertical ends . Gap between the bars should not be more than 150mm . Window frames shall be fixed to brick / concrete masonry by using nylon self expension caps & 75/100 mm MS screws after drilling in walls. VC Black Gypsum Drywall screws should be used while fixng corner brackets,stay,hinges,mullion caps of windows. . Windows to be procured from any of the below mentioned companies- i)_Ashwani and sons, 1246/2 Meerut Road,Morta, Murad nagar-201003 ii)TATA Steel-Mumbai iii)Jindal,2-32,Gurgaon, Haryana-122001iv) Ashish Industries, R-4/66, Raj Nagar, Ghaziabad , Ph-9891542779
S&F 100mm x 63mm single rebated facotry made 100% solid WPC Door frame made from 100% LEAD Free (Single extruded process) material with density 780 kg/cum and manufactured by an ISO : 9001-2015 certified company , all as per specification. The door frame should be water proof, termite proof, fire retardent and having excellent screw holding capacity complete all as specified & directed. Make:- ECHON/ Flooresta/ Archidply as approved by Engg-in-Charge/GE.
S&F 30mm thick molded WPC factory made 1005 solid door shutter (confirming as per IS: 4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 600kg/cum manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, termite proof, fire retardent and having screw holding capasity complete all as specified & directed. Make:- ECHON/ Flooresta/ Archidply as approved by Engg-in-Charge/GE.
S & F Butt hinges, 100 mm long stainless steel non magnetic ( ISI marked ) complete all as specified and directed..
S & F Butt hinges, 75 mm long stainless steel non magnetic (ISI marked) complete all as specified and directed..
S&F 300mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and directed.
S&F 200mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and directed.
All as per item No. 39 here in before but 150 mm length of bolt.complete all as specified and directed.
S & F Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified and directed.
S & F Aluminium handles cast type anodised of size 125 mm long ISI marked complete all as specified and directed.
M/L Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165. complete all as specified and directed.
S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165.complete all as specified and directed.
S&F, in repair, for Stainless steel wire cloth non megentic of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples. Complete all as specified and directed by Engineer in Charge .
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 sq.m. each pane including hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones.complete all as specified and directed.
Disconnecting existing tanks, setting side (or lowering if required) for repairs, cleaning and removing all scale and dirt etc. from tanks and mouths of circulating pipes etc. and hoisting if required reconnecting and refixing in position exc 250 Ltrs but n .exc 500 Ltrs capacity .complete all as specified and directed.
Dismantling water tanks exc 250 & n exc 500 capacity in litres and removing to store.complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tank (ISI Marked only) including, plastic lid cover ( ISI Marked) , double layered, cylindrical vertical with closed top hoisted and fixed in position of capacity 500 ltrs including making connections,20 mm dia ball valves( ISI Marked heavy duty ) high pressure PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe anf fixed (min wt 210 gram) complete all as specified in SSR Part I.complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in Stone concrete block or slab walls. complete all as specified and directed.
Taking up or down steel tubing with connections for cleaning for refixing or removing to storeyard complete of bore 15mm.complete all as specified and directed.
Taking up or down steel tubing with connections for cleaning for refixing or removing to storeyard complete of bore 20mm. complete all as specified and directed.
S& F for GI tubing 15mm bore, medium grade ISI marked with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions, including short lengths etc.) ( heavy grade ISI Marked) , fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and directed.
S& F for GI tubing 20mm bore, medium grade ISI marked with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions, including short lengths etc.) ( heavy grade ISI Marked) , fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and directed.
S & F in repairs vitreous china squatting pan 'orissa pattern 580 mm X 440 mm white (ISI Marked only) with integral foot rests (excluding flushing cistern and heavy duty flushing pipe (ISI Marked only) but incl fixing of flushing cistern, flush pipe (ISI Marked only),12 mm dia 450 mm long PVC connection (ISI Marked only) etc complete) complete all as specified and directed.
S & F CI Nahani trap 75 mm dia with grating (ISI Marked only) including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) complete all as specified and directed
S & F in repairs stainless steel kitchen sink 1.00 mm thick (ISI Marked only) for kitchen with plugs, washer and waste 32/40mm dia incl bedding in cement mortar on to dwarf wall or including fixing cantilever cast iron brackets and connecting union to waste pipe overall all size 495mmx420mm bowl size 410x330x160mm complete all as specified directed.
S & F in repairs PVC low level flushing cistern (ISI Marked only), valveless, syphonic action dwell type, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 60/90 cm long etc, supplied and fixed, complete all as specified.
S&F Vitreous china wash hand basin ,white ,flat back of size 550x400mm (ISI Marked only) with PVC connection 15mmdia 450 mm long with PTMT (ISI Marked only) nuts and PVC washer and including cutting for pinning in ends,pair of cast iron brackets and provision of PVC waste pipe 32mm of adequate length , waste coupling 32 mm dia of PTMT half or full threaded Min wt 45 gram,complete all as specified and directed by Engr-in-charge.
Supply only low density PVC pipe 32 mm dia as in waste pipe to sink (ISI Marked only) complete all as specified and directed
Demolition and breaking up 150 mm internal dia drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
M&L 150 mm bore Salt-glazed stoneware drain pipes laid in trenches and jointed as specified SGSW drain pipes ISI Marked) laid in trenches.complete all as specified and directed.
M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in concrete bed of drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipes.complete all as specified and directed.
S&F in repair soap dish brass chromimum plated screw 125mm size complete all as spcified and directed Make – JaquarEssco Cat part No. AEC-1131N ,Hindware Cat Part No. F-890005 Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
S&F in repair bib tap cast copper alloy with crutch or butter fly handle, screwed down for iron pipe 15 mm bore of tubing fancy type cromium plated (ISI Marked). complete all as specified and directed.Make -JaquarEssco Cat No MQT-511KN or equvalent in Gem Cat part No. 12210 Gem and Hindware Cat part No. F200003 ( Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
S&F in repair stop valve cast copper alloy screwed down high presure screwed both end for iron pipe 15 mm dia fancy type cromium plated (ISI Marked). complete all as specified and directed. Make JaquarEssco Cat Par No -MQT-526KN or equvalent in Part No. 12260 (Gem), F110004 (Hindware) Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
S&F in repair Pillar taps, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly-nuts, screwed for iron pipe screwed down for 15 mm dia bore GI pipe complete all as specified and directed Make –Jaquar Essco Cat Part No DLX 508 KN or equivalent in Gem , Hindware ( Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
S&F in repair 20 mm dia bras chromium palted tubler towel rail D type 60 cm long between flange including one pair of fixing brackets complete all as specified and directed Make – JaquarEssco) Cat Part No. AEC-1111N ,Hindware Cat Part No. F-870012 ( complete all as specified and directed.
S&F in repairs PVC ( SWR ) floor trap ( ISI Marked) of 75mm dia of outlet, plain with grating including jointing with solvent cement.complete all as specified and directed.
S&F PVC (SWR ) bend of 75 mm bore ( ISI Marked) pipe of any radius.complete all as specified and directed.
All as per sl item 71 above but with access door ( ISI Marked).complete all as specified and directed.
S&F in repairs PVC ( SWR ) waste pipe pipe ( ISI Marked) of 75 mm dia bore in any length ,single socketed with rubber ring joints laid in trenches or in floors.complete all as specified and directed.
All as per item 73 here in before but 110mm dia ( ISI Marked)complete all as specified and directed..
S&F PVC ( SWR ) junction single,(single T) equal or unequal 110mm bore with access door ( ISI Marked) .complete all as specified and directed.
S&F PVC ( SWR ) vent cowl 75mm bore ( ISI Marked). complete all as specified and directed.
S&F PVC ( SWR ) waste pipe of 75 mm dia bore in any length ( ISI Marked) ,single socketed with rubber ring joints fixed to walls with necessary MS fixtures all as directed
S&F as in repairs grating doom 100mm dia ( ISI Marked) with waste hole of PTMT (Min. Wt. 25 gram ) complete all as specified and directed.
Demolition Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L for walling of random rubble stone masonry, un-coursed, well bonded, bedded, solidly hearted and built in cement mortar 1:6 complete all as specified and directed.
M & L for walling of random rubble stone masonry but except stones un-coursed, well bonded, bedded, solidly hearted and built in cement mortar 1:6 complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level ) and including removing unserviceable material,outside of A 1 defence land complete all as specified and directed.
M&L cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) 75 mm thick as in plinth protection surface finished even and smooth without using extra cement including 4 mm thick glass dividing strip of figured glass, pin headed type, 73 mm wide inserted in position Complete all as specified and directed by Engineer in Charge .
M & L PCC Type C-1 1:3:6 (using 20 mm graded stone aggregate) as in surface channels and drains or benching in manholes complete including necessary form work as specifed and directed.
M & L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.
Dismantling and taking down U/S copper / aluminium point wiring (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates ii) If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
All as per item No.83 above but one light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way. complete all as specified and directed.
All as per item No.83 above but one 3 pin 5 Amps socket outlet on same board controlled by one, one way 5 Amps piano switch.complete all as specified and directed.
All as per item No.83 above but one socket outlet 5/3 pin 5 Amps controlled by one switch on independent board.complete all as specified and directed.
All as per item No 83 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point.complete all as specified and directed.
S & F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz all as specified and directed by Engr-in-Charge.Make: Legrand cat No: 6734 01/ Indoasian Cat No: 800000 or equivalent make of L&T/Havells
Supply and fix Modular switch 1 way 16 Amps, 1 module, 230 volts, 50 hz white/ivory finish all as specified and directed by Engr-in-Charge. Make: Legrand cat No: 6734 11/ Indoasian Cat No: 800002 or equivalent make of L&T /Havells
Supply and fix Modular switch 1 way 16 Amps, 1 module, 230 volts, 50 hz white/ivory finish all as specified and directed by Engr-in-Charge. Make: Legrand cat No: 6734 11/ Indoasian Cat No: 800002 or equivalent make of L&T /Havells
Supply and fix Modular Socket outlet, 16A - 6 pin combined, 2 module ISI marked, 230 volts, 50 hz all as specified and directed by Engr-in-Charge. Make: Legrand cat No: 6734 55/ Indoasian cat No 800022 or equivalent make of L&T/Havells .
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting ISI marked complete all as specified & directed Make : Anchor/ Cona / Havells
M&L ceiling rose 3 terminal / PVC/ polycarbonate,ISI marked 230 volts,50 Hz isolated body all as specified and directed Make : Anchor Cat part No.14307/ Cona Cat Part No.7091 / or equivalent in Havells.
S & F bell push Modular single pole, one way 6 Amps , 1 module, ISI marked, 230 volts, 50 hz all as specified and directed by Engr-in-Charge.Make: Legrand cat No: 6734 06 / Indoasian cat no: 800007 or equivalent make of L&T /Havells.
S&F bell ding dong elelctric 230V AC single pole all as speccified and directed Make : Anchor cate part No doorbell-10489-1B or equavalent in Cona / Havells
S&F MCB DB TPN 4 way with 200 amps 415 V rated copper busbar in sheet steel enclosure,double door type,complete all as specified and as directed. Make:- Legrand,Schneider,Siemens,L&T,
S&F MCB DB SPN 8 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and as directed. . Make:- Legrand,Schneider,Siemens,L&T,
Supply & fixing MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed. Make:- Legrand,Schneider,Siemens,L&T,
Supply & fixing MCB, SPN, AC, 240 volts of 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed. Make:- Legrand,Schneider,Siemens,L&T,
Supply & fixing MCB, TPN, AC, 415 volts of 63 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed. Make:- Legrand,Schneider,Siemens,L&T
Supply and fix surface mounted LED luminiare, 20 watt with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose all as directed. Model: SZSLBMX020 of Shakti or equivalent make of Philips or crompton. Note: The firm has to give warranty for fitting including driver minimum for 3 years for any defects developed during the period.
S&F LED Bulb 10 Watt (Cool day light) housing made from polycarbonate, with opaque diffuser, having Colour temp 6500 K and lumen output 950, voltage range 120V-280V AC, power factor >0.9, THD <33% suitable for “B-22 type to fix on batten holder Make : Shakti/Havells/Wipro/C&S.
Supply and fix new LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit prtection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive wway, 80 degree luminaire efficiciency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing on existing bracket including connecting with 1.5 sqmm , 3 core, PVC insulated copper onductor cable 1100 Volt grade from distribution box to light complete all as specified and as directed by Eng-in-Charge (i) The firm has to given warranty of street light fittings including driver minimum for 03 years for any defect developed during the period. (ii) The contractor Shall submitt the third Party LM 79 report from any NABL approved laboratory (iii) The fiitting should have BIS , CRS No(iv) Connection to luminaire shall be done in suitable PVC connector within the bracket/luminaire end and are inclusive in above.
S&F sub main wiring with two single core PVC insulated,unsheathed, stranded copper conductor cable 6 Sqmm with 6 Sqmm FRLSH PVC insulated, unsheathed, stranded copper conductor cable as earth wire in existing surface/recessed steel/PVC conduit and earth wire connected to common earth dolly all as specified & directed. Note: Three run of 6 sqmm cable shall be measured as one unit Make:- Havells,KEI,Universal,RPG,Gloster
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 25 sqmm 3.5core complete all as specifed and directed. Note:- The Earth work,GI pipe Shall be measured and paid Sepretely under appropriate item of Sch A
Excavation in trenches in all type of soil not exc 1.5 m wide and not exceeding 1.5m in depth for laying UG cable/foundation etc complete all as specified and directed.
Returning filling in soft/disintegrated soil including spreading levelling watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed.
Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Material and Labour for sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. (Note:- Punned thickness shall be considered for payment purpose.)
Supply and laying well burnt clay brick old size class 'B' laid dry flat for protection over the cable, width equal to the length of brick complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by 4 mm GI wire as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
PIONEER REFRIGERATION AND ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .