Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC 260 332 285 WARD NO 24 VILL SOUTH JAGADISHPUR BANSHTALA ULUBERIA | ULUBERIA | HOWRAH | WEST BENGAL | 711315 | L1 | Accepted-AOC Lowest bidder rate | |
| 2 | L2₹2.7 L+₹404.02 (0.15%)Rejected-Finance 16 B VIVEKANANDA ROAD NABAGRAM HOOGHLY 712246 | HOOGHLY | HOOGHLY | WEST BENGAL | 712246 | L2 | Rejected-Finance L2 | |
| 3 | L3₹2.7 L+₹634.04 (0.24%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹5,578
Closing Date
27 Dec 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Assistant Engineer, EMSD-II,PHE Dte.
Office of the Assistant Engineer.Eastern Mechanical Sub Division - II, P.H. Engineering Directorate.A2 Market, Rail Gate, Shiv Mandir, P.O.- Kalyani, Dist.- Nadia.
Dismantling and carrying the defective voltage stabilizer to storehouse and supply, delivery and installation of new voltage stabilizer and allied works at P/H-II under SONDA (ZONE-I) PWSS in KRISHNAGAR-I BLOCK, PHE Dte., Dist.-Nadia.
2024_PHED_781048_3
WBPHED/AE/EMSD-II/NIET_12 of 2024-2025
Open Tender
MECHANICAL
Item Rate
30 days
Kalyani
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,578
Yes
17 Feb 2025
13 Dec 2024
30 Dec 2024
13 Dec 2024
27 Dec 2024
14 Dec 2024
Amount
Dismantling & taking out the existing defective voltage stabilizer & allied accessories from its existing position after disconnection of electrical power connection & allied works by skilled electrician and labours as per direction of EIC.
Supply, delivery and storage at site 15 KVA, 3-Ph, Oil cooled type Servo Motor operated copper wound line voltage corrector suitable for un-balanced input voltage with following specification including first filling oil. I/P Voltage: 225V-500V (phase to phase) or 130V-290V (phase to neutral) O/P voltage: 415V ± 1% Line regulation: 1% of set voltage. Load regulation: 1% of set voltage. Efficiency: getter than 95% on full load. etc. as per specification of NIT. [Make of Machine: As per attached latest vendor list of PHED.] N.B. 1) T.C. & G.C. of pump & motor needed. 2) All works should be carried out as per relevant & latest IS code.
Supply, delivery and storage of 63 Amp, 415 V AC, 4 Way, wall mounted, Copper Bus-Bar Chamber as per relevant standard. [Make- Havells/ any equivalent Dept. approved.]
Supply, delivery and storage of 63 Amp, 415 V AC, Four Pole, wall mounted, Changeover Switch, as per relevant standard. [Make- Havells/ any equivalent Dept. approved.]
Supply, delivery and storage of 63 Amp, 415 V AC, Three Pole with Neutral link, wall mounted, Main Switch as per relevant standard for VS. [Make- Havells/ any equivalent Dept. approved.]
Supply, delivery and storage of 25 sq.mm., 1.1 kV grade, 3.5 Core, XLPE insulated, Al., Ar. Cable as per relevant standard. [Make- Havells/ any equivalent Dept. approved.]
Making brick built foundation with supplying of all required materials suitable for the above voltage stabilizer by (4:1) cement mortar including holding down foundation bolts (if required) and plaster with neat cement finish incl, dept settled painting done as per direction of EIC.
Installation of above supplied VS on the foundations including all connection complete including socketing the cable ends and testing commissioning the same as per direction of EIC.
Drawing of supplied cable on ground/floor/wall with fixing by saddles etc. as per direction of EIC.
Making joints of the cable by supplying compression type gland thimple, socket etc. as per requirement and as per direction of EIC.
Earthing with 50 mm dia. G.I. pipe, 3.65 mm thick & 3 mtr long (2 sets) and conn.by 25mm x 6 mm G.I. strip (for required length) upto earth bus-clamp with equipments on wall/floor with staples buried inside as reqd. at site and with 25 mm x 6 mm GI flat strip to earth electrode pipe, fastening with 13 mm x 80 mm G.I. bolts, nuts, washers, incl. all f&f of materials, filling & restoring the suface by ramming & making suitable earthpit with brick structure & MS lid on top as per direction.
Making internal/external electrification of P/House by 2 x 1.5 sq.mm. P.V.C. Cu. wire through suitable size casing/capping for 4 nos. point ( 1 no. bracketpoint , 1 no. LED tube light point , 1 nos. LED bulk head point and 1 fan point ) and 1 no. 5A ,5 pin plug point with earthing attachment of 1 x 1.5 sqmm cu. Wire with supplying of tube light fittings (Make-Philips/as per approved vendor list.), fan (Make- as per approved vendor list), bulbs (Make- Philips/as per approved make) including suppying and fixing 10 A. DP MCB (As per approved vendor list.) make on wall all complete as per I.E. rules and direction. (including making external illumination by Supply & fixing of 1 no. 45W LED IP 66 type outdoor luminairie incl. Supply & installation of MS bracket & connection complete) (Make : As per Approved Vendor List.)
Supply, delivery & storage of plastic chair without hand rest. [Make- any equivalent Dept. approved make]
Supply, delivery & storage of plastic chair table. [Make- any equivalent Dept. approved make]
Carrying of dismantled defective VS & other items, etc. from worksite to storehouse (appx. 80 km) for future repairing purpose including loading & unloading complete the job as per direction of EIC.
Add GST @ 18%
Add LWC @ 1%
ANJAN ENTERPRISE (BID ID -5863864)
SMILE (BID ID -5863685)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .