Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹3.0 L+₹17,220 (6.01%)Rejected-Finance PANCHAYATI RAJ ROHTAK | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹3.4 L+₹57,345 (20.0%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹3.6 L+₹73,350 (25.6%)Rejected-Finance C 488 SC PLOT NO 10 EKTA NAGAR NEAR ANANT LEWIS PUBLIC SCHOOL BANAR ROAD NANDRI PO SARAN NAGAR JODHPUR 342015 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L4 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹7,760
Closing Date
9 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) R AND D JODHPUR
AGE (I) R AND D JODHPUR, Defence Laboratory, Ratanada Palace, Jodhpur- 342011
PROVISION OF STONE MASONARY WALL FOR SAFETY OF DETC INCUMBENTS AND 02 X SOAK PIT NEAR MEGH BLDG AT DEFENCE LAB JODHPUR
2021_MES_421998_1
8414/E8
Open Tender
Civil Works
Item Rate
120 days
AGE (I) R AND D JODHPUR
AS PER TENDER DETAILS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹7,760
Yes
6 Jul 2021
13 Feb 2021
11 Mar 2021
13 Feb 2021
9 Mar 2021
23 Feb 2021
15 Feb 2021 - 22 Feb 2021
60 days
Amount
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and getting out in hard/dense soil complete all as specified and directed by Engineer-in-charge.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed by Engineer-in-charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as speciified & directed by Engineer-in-charge.
M&L for 100 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded granite stone aggregate) in sub base of foundation & column footing complete all as speciified & directed by Engineer-in-charge.
M&L for Squared rubble walling, Jodhpur type, regular courses, well bonded, bedded & solidly hearted, built in CM(1:4) complete all as speciified & directed by Engineer-in-charge.
Hammer dressing to face stones with maximum depression on face from a straight edge not exc 20mm & dressing face beds & joints as specified to square rubble walling, Jodhpur type, brought upto courses complete all as speciified & directed by Engineer-in-charge.
M&L 15 mm thick , plaster in cement mortar (1:4) on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing and finishing the surface even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion paint of approved tint over a coat of primer complete all as specified & directed by Engineer-in-charge.
S&F mild steel in framed work as in doors or gates or other such as grills, gratings, etc., with ends of bar shoulder &/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks & similar work conforming to Fe 290 GDE -E-165 complete all as speciified & directed by Engineer-in-charge.
M&L for preparation of New or previously un-treated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as speciified & directed by Engineer-in-charge.
Refixing old existing Anodized Aluminium partition panel /section from one location to another in office premises and fixing on PCC Floor/tiling/wall tiles with necessary screws by drilling in position and making necessary repair to aluminium partition if requied complete all as specified & directed by Engineer-in-charge.Note :- rates are included for glass pane,pre-laminated sheet in aluminium partition should be taken out from frame and refixing in the same opening including necessary jointing cleats,glazing clips,rubber packing,anodised aluminium snap beading,screws,anodised aluminium fittings etc complete all as speciified & directed by Engineer-in-charge.
S&F in Anodized Aluminium Frame for doors, windows, ventilators,partition with one or more rebates including joining cleat for fixing etc. complete all as speciified & directed by Engineer-in-charge.
S&F Anodized Aluminium door shutters, aluminum section weighting 0.55kg / m including necessary joining cleats, glazing clips, rubber neoprene packing, handles two nosin each door,100mm Butt hinges, extruded aluminium alloy B-21 hinges, anodized aluminum snap beading, screws etc complete all as speciified & directed by Engineer-in-charge.
S&F Solar control film 25 micron reflective type (gareware sun control or equivalent) complete all as speciified & directed by Engineer-in-charge.
S&F 12 mm thick Prelaminated particle board exterior grade both side laminated in bottom panel or complete all as speciified & directed by Engineer-in-charge.
S&F Brass Mortice lock, vertical type, size 100 mm 4 levers complete all as speciified & directed by Engineer-in-charge.
Supply and fixing door closer hydraulically regulated designation No 3, universal type, suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 Kg of aluminium (Die cast) body complete all as speciified & directed by Engineer-in-charge.
SOAK WELL:- Excavation of soil any type,PCC foundation type C1 (1:3:6)(20mm graded stone aggregate ,well of honey combed and solid in M-25 concrete,including intercepting chamber,screen chamber ,stone masonary in CM( 1:4), RCC cover slab in M-25/RR Masonary/ filling with brick bats (size of soak pit 2.40 mtr dia X 3.00 mtr deep) as per drawing complete all as speciified & directed by Engineer-in-charge.
M&L 150mm dia Reinforced concrete pipes, class NP2, laid & jointed complete with collars complete all as speciified & directed by Engineer-in-charge.
M&L PCC (1:3:6) type C-2 as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in for 150 mm bore pipe complete all as speciified & directed by Engineer-in-charge.
M&L for cutting into existing manholes for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20 mm graded complete) smooth finished and reforming benching as required complete (Internal dia of pipe 150 mm) complete all as speciified & directed by Engineer-in-charge.
M&L plain cement concrete (1:2:4) type B-1 using 20 mm graded stone agg as in coping, benching cills, seismic and other similar bands and the like including weathering sliglitely rounded or chamfered angles and throating complete all as speciified & directed by Engineer-in-charge.
M&L for Jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted & set, jointed & grouted in lime mortar 1:3 complete all as speciified & directed by Engineer-in-charge.
S&F cast-iron sand cast soil waste and vent pipe 100mm bore in any length with or without ears with cement joint laid in trenches or in floor/walls including vent cowl complete all as speciified & directed by Engineer-in-charge.
HOODA CONSTRUCTION COMPANY
vinayandsons
SNEH CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .