Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC SHOP NO 13 MOHINI MARKET KISHORE BAGH MANDORE JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹12.5 L+₹77,606.50 (6.64%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹14.7 L+₹3.0 L (26.1%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L3 | Rejected-Finance Not lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
1 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR/MAINT OF SECURITY LIGHT, PERMETER LIGHTS, CABLES JUNCTION AND ALLIED ITEMS IN AA BANAR
2022_MES_521658_1
8822/10/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Banar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer Banar
₹40,000
Yes
9 Jun 2022
4 May 2022
3 Jun 2022
4 May 2022
1 Jun 2022
18 May 2022
60 days
Amount
Taking out old unserviceable LT UG cable, Supply and laying, testing, commissioning in replacement of LT underground cables, 1100 volts grade, XLPE insulated PVC sheathed, heavy duty armoured, with multistranded aluminium conductors of size 10 Sqmm 2 core, IS-7098 (Part-I) marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified. Note : The heavy duty lugs/thimbles to terminate the LT cables with proper crimping tool should be deemed into the rate qoted in this item.
All As per Item Srl No 1.00 above but of size 16 Sqmm 4 core.
All As per Item Srl No 1.00 above but of size 35 Sqmm 3.5 core.
Excavation in trenches in any type of soil not exc 1.5 mtr in depth and 1.5 mtr wide and getting out for laying of cables.
All as per ser No-04 above but depth exc 1.5 mtr but not exc 3.00 mtr.
Returning and filling in including spreading, leveling , watering and well ramming in layers not exceeding 25 cm thick of excavated earth complete all as specified.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing at a leval not exceeding 1.5 mtrs above the starting point complete all as specified.
M&L for tibba sand locally available sand filling in trenches dry and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified.
Supply and laying reinforced precast concrete cable cover, class LV, Type 2, flat, size 300mmx180mmx40mm laid perpendicular to cable length in trench air gap should not more than 5mm to each other after sand cushioning to cable and all as specified.
Dismantling of unservicable PCC/ steel tubular poles of any type and Supply and erect Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including 2 coats of aluminium painting over a coat of primer and writing pole No etc complete all as specified and directed. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.
S&F in replacement of 40 mm dia GI pipe bracket (light grade) bent to shape of length not less than 1.2 mtr including fixing on wall/pole using flat iron clamps of suitable size ,nuts,bolts,washers etc includig paint of two coats of alluminium paint over one coat of red oxide primer for FI clamps for street light fittings all as specified and directed by Engr-in-charge.
M&L for cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate) for foundation of pole / stay including form work etc.
M&L PCC (1:3:6) Type C1 with 20 mm graded stone aggregate for coping of poles or in base of platform including form work in any situtaion as required and directed at site
S&F in replacement of galvanised tubes 50 mm bore light grade with all fittings like bend, elbow, reducer, socket tee laid in trenches icnluding all necessary clamps if required and all as specified and directed.
S&F in replacement of galvanised tubes 40 mm bore light grade with all fittings like bend, elbow, reducer, socket tee laid in trenches icnluding all necessary clamps if required and all as specified and directed.
Taking down defective street light/ flood light/post top lantern fitting of any size /type/capacity 45-150 Watt from height of pole/walls/high mast of any location up to 12M height for repair work and fixing back after repair work including checking, inspecting, testing and commissioning complete all as directed by Engr-in-Charge. Note :- (a) Spares like LED Driver,surge protector etc. shall be measured and paid as supply only separetely under relavant items of schedule'A' (b) Necessary tools like mobile ladder & other T&P required etc shall be arranged by the contractor without any extra cost. (c) The rate quoted deemed to be inclusive for minor repair parts like nuts, bolts, cirle clips , clamps etc required if any at site.
Supply only electronic driver for LED light fitting, LED out put power 45 watt, input voltage range : 170 - 300 volt AC , out put voltage DC as per make/ model range: 24 volt to 110 volt, make as per site requirement complete all as directed.
All as per item No 17.00 above but capacity 75 watt
All as per item No 17.00 above capacity 100watt
All as per item No 17.00 above capacity 150watt
Supply only Surge Protector 10KV for street light fitting, Normal voltage input range : 170- 300 volt complete all as specified and directed by Engineer-in-Charge.
Material and labour as in repair for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed andinclusive of one primer coat, one under coat and one finishing coat of paint etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement loop-in/ loop-out box of outer size 155x210x92 mm (Hensel) made out of FRP(Hot moulded type), IP-66 protection , suitable for outdoor installation with weather proof canopy and locking screws along with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed.
Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by using of PCC 1:2:4, type B1 and matching with the surroundings all as directed.
Supply and fixing in repalcement of power contactor 3 pole 415 volts 45 Amp operatnig coil of 230 volts with control wiring and ferrule/thimbles for connections and all as specified.
Supply and Fixing in replacement of digital timer double module, astronomical type along with replacig the control wiring of Street light timer panel and all as specified.
Supply andd Fixing in replacement of MCB SP 230 volts 10KA ,5-32 Amps capacity all as specified.
Supply and fixing in replacement of MCB TPN 415 Volts 50Hz, rupturing capacity 10KA of capacity 63Amp and all as specified.
Fixing only street light fitting LED type of 60-120 Watt and any size suitable for mounting on 40 mm dia bracket arms with pole fixing attachements and proper fixing/connecting of service cable from pole box to street light fitting including taking out old existing light fitting complete all as specified and directed by Engr-in Charge. Note :- LED street light luminares shall be issued to contractor under Schedule 'B" free for fixing.
Fixing only LED flood light luminares 100-150 watt mounted on bracket at height of 6 mtr to 12 mtr on pole/high mast inclunding taking out existing flood light fitting complete all as specified and directed by Engr-in Charge. Note :- LED street light luminares shall be issued to contractor under Schedule 'B" free for fixing.
Supply and Fixing in replacement of Rigid non-metallic PVC conduit 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, locknuts, saddles, pipe hooks etc on steel tubular/PCC/RCC Poles and all as specified and directed.
Supply and connecting in replacement PVC wire 4 sqmm nominal area 3 Core multi stranded aluminum conductor PVC sheathed and weather proof round/flat shape and drawn through PVC conduit/ steel tubular pole and connecting to Street light fitting on PCC/RCC/Steel pole all as specified and directed at site by Engr-in-charge.
Supply and connecting in replacement PVC wire 6 sqmm nominal area 2 Core multi stranded aluminum conductor PVC sheathed and weather proof rflat shape and drawn through PVC conduit/stretched on pole/srut/wall and connecting to Street light fittinf on PCC/RCC/Steel pole alla s specified and directed at site by Engr-in-charge.
Supply and connecting in replacement PVC wire 10 sqmm nominal area 2 Core multi stranded aluminum conductor PVC sheathed and weather proof rflat shape and drawn through PVC conduit/stretched on pole/srut/wall and connecting to Street light fittinf on PCC/RCC/Steel pole alla s specified and directed at site by Engr-in-charge.
Trimming and cutting of tree branches coming across LT over head line, clearing the line around 1.5m on both sides and disposal of shrubs to a distance up to 500mtr distance and cleaning the site complete all as directed. Note :- (i) Length of span shall be 45 to 50m. (ii) Due care shall be given while trimming/cutting the tree branches that there shall be no damage to over head line conductor/pole. In case, due to any negligence, damage is caused, it shall be made good by the contractor and nothing extra shall be admissible. Note : All T&P shall be provoded by contractor
Material and labour for decarbonising the electric connection of street light fitting on pole/junction box/OH conductor and made fresh end of cable and reconnecting the cable by ensuring the tight/ proper connection to the street light fitting and all as specified and directed.
M/s Vishaka Enterprises
Anil Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .