| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC PLOT NO 102 H NO 21 1382 102 GROUND FLOOOR SAMATHA NAGAR COLONY OLD SAFILGUDA ROAD NO 3 HYDERABAD RANGAREDDI TELANGANA 500056 | HYDERABAD | TELANGANA | 500056 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹41.6 L+₹1.2 L (3.03%)Rejected-AOC D NO 49 23 27 A FLAT NO 301 3RD FLOOR SRI SAI TIRUMAL ENCLAVE LALITHANAGAR VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹42.5 L+₹2.2 L (5.39%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹42.9 L+₹2.6 L (6.45%)Rejected-AOC D NO 58 20 33 FLAT NO F 2 VAIKUNTAPARVATHI RESIDENCY APSEB COLONY BUTCHIRAJUPALEM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹43.2 L+₹2.8 L (7.03%)Rejected-AOC | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | G Srinivas Rao L2 | SATYAMEGHA ENGINEERS L5 | SRI THULASI TECH L6 | venkata sai constructions L4 | NAVEEN INFRASTRUCTURES L7 | Squad 7 Projects and Services Pvt Ltd L1 | K.ADITYA ENGINEERING CONTRACTORS L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| .01SCHEDULE 'A' PART-I: B/R WORKS | ||||||||||
| 1.00 | Dismantling floor, hearth or wall tiling incuilding cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises. | 49.41 | Sqm | 70 ₹3,458.7 | 60 ₹2,964.6 | 110 ₹5,435.1 | 132 ₹6,522.12 | 120 ₹5,929.2 | 52.35 ₹2,586.61 Lowest | 70 ₹3,458.7 |
| 2.00 | M&L for light shade Virified Ceramic coloured tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement lurry and pointed in white or coloured cement to match and laid over 15 mm thk cement screed bed in cm 1:6 for laying floor finishes. | 29.01 | Sqm | 1,200 ₹34,812 | 1,100 ₹31,911 Lowest | 1,500 ₹43,515 | 1,200 ₹34,812 | 1,550 ₹44,965.5 | 1,178 ₹34,173.78 | 1,450 ₹42,064.5 |
| 3.00 | M&L Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cm 1:6 for laying floor finishes. | 3.6 | Sqm | 1,100 ₹3,960 | 1,000 ₹3,600 | 1,150 ₹4,140 | 1,100 ₹3,960 | 1,150 ₹4,140 | 807.5 ₹2,907 Lowest | 1,250 ₹4,500 |
| 4.00 | M&L for Glazed ceramic coloured tiles 350x250x7 mm/450x350x7 mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in white or Coloured cement to match & including 10mm thick rendering in CM (1:4) on fair faces of brickwork or concrete surfaces. | 16.8 | Sqm | 1,000 ₹16,800 | 1,200 ₹20,160 | 1,050 ₹17,640 | 1,100 ₹18,480 | 1,050 ₹17,640 | 760 ₹12,768 Lowest | 1,250 ₹21,000 |
| 5.00 | Demolition of stone slabs tiles of any description or thickness in floors aprons laid bedded and pointed in any morter etc | 0.07 | Per 10 Sqm | 5,000 ₹350 | 600 ₹42 | 5,000 ₹350 | 5,500 ₹385 | 6,000 ₹420 | 253.12 ₹17.72 Lowest | 5,000 ₹350 |
| 6.00 | S&F for Anodised aluminium snap grid of size 605x605mm framed work for false ceiling all as specified with 4mm thick GI suspender complete all as specified and as directed. | 20 | Sqm | 1,000 ₹20,000 | 1,500 ₹30,000 | 1,050 ₹21,000 | 1,050 ₹21,000 | 1,050 ₹21,000 | 522.5 ₹10,450 Lowest | 1,000 ₹20,000 |
| 7.00 | M & L for 12 mm thick medium density fibre board exterior grade fixed to timber framework with screws as in ceiling flat or sloping . | 20 | Sqm | 1,500 ₹30,000 | 500 ₹10,000 Lowest | 1,500 ₹30,000 | 1,500 ₹30,000 | 1,600 ₹32,000 | 912 ₹18,240 | 1,800 ₹36,000 |
| 8.00 | Demolition of reinforced cement concrete in ground floors and paving not exc 15 cm thickness (below or aboce ground Level.) | 2.7 | Cum | 2,500 ₹6,750 | 800 ₹2,160 | 2,550 ₹6,885 | 2,540 ₹6,858 | 2,550 ₹6,885 | 332.5 ₹897.75 Lowest | 2,500 ₹6,750 |
| 9.00 | Earthwork in excavation in foundation trenches n.exc 1.50m wide and n.exc 1.50m in depth and getting out in soft/loose soil complete all as specified and as directed. | 58.5 | Cum | 250 ₹14,625 | 450 ₹26,325 | 255 ₹14,917.5 | 255 ₹14,917.5 | 255 ₹14,917.5 | 214 ₹12,519 Lowest | 250 ₹14,625 |
Tender Value
₹43.8 L
EMD Value
₹87,600
Closing Date
12 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Naval Depot
GARRISON ENGINEER NAVAL DEPOT INDUSTRIAL ESTATE 104 AREA VISAKHAPATNAM 530007
ADDITIONS AND ALTERATION OF AIR DEPARTMENT AT INS DEGA VISAKHAPATNAM
2025_MES_702149_1
8457/GEND/E8
Open Tender
Civil Works - Others
Item Rate
Visakhapatnam
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE ND VISAKHAPATNAM
₹87,600
Yes
8 Oct 2025
3 Apr 2025
14 May 2025
3 Apr 2025
12 May 2025
18 Apr 2025
Amount
SCHEDULE 'A' PART-I: B/R WORKS
Dismantling floor, hearth or wall tiling incuilding cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises.
M&L for light shade Virified Ceramic coloured tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement lurry and pointed in white or coloured cement to match and laid over 15 mm thk cement screed bed in cm 1:6 for laying floor finishes.
M&L Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cm 1:6 for laying floor finishes.
M&L for Glazed ceramic coloured tiles 350x250x7 mm/450x350x7 mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in white or Coloured cement to match & including 10mm thick rendering in CM (1:4) on fair faces of brickwork or concrete surfaces.
Demolition of stone slabs tiles of any description or thickness in floors aprons laid bedded and pointed in any morter etc
S&F for Anodised aluminium snap grid of size 605x605mm framed work for false ceiling all as specified with 4mm thick GI suspender complete all as specified and as directed.
M & L for 12 mm thick medium density fibre board exterior grade fixed to timber framework with screws as in ceiling flat or sloping .
Demolition of reinforced cement concrete in ground floors and paving not exc 15 cm thickness (below or aboce ground Level.)
Earthwork in excavation in foundation trenches n.exc 1.50m wide and n.exc 1.50m in depth and getting out in soft/loose soil complete all as specified and as directed.
Earthwork in excavation in foundation trenches n.exc 1.50m wide and exc 1.50m and nexc 3.00 m in depth and getting out in soft/loose soil complete all as specified and as directed.
M&L for Cement concrete Plain cement concrete 1:4:8 type D2 as in foundations, filling and mass concrete and similar works complete all as specified and as directed.
Returning, filling in, including, spreading, leveling, watering and well ramming in layers n.exc 25cm complete all as specified and as directed
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and as directed.
M&L for M30 Desgn mix in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for Cement concrete M30 design mix as in Beams, cantilevers, bressummers, lintels over 1.5m span similar works complete all as specified and as directed.
M&L for Cement concrete M30 design mix as in Columns, pillars, piers, posts and struts and similar works complete all as specified and as directed.
M&L for Cement concrete M30 design mix Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for flat edges Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed
M&L for formwork to sides of RCC columns ,Pillars ,Posts,Struts, foundations , Piers finished in rough surfaces finishned rough complete all as specified and as directed
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and as directed.
M&L TMT bars 5 mm dia and over upto and incl 10mm, bent to shape required including cranking bending spirally for stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete.
M&L TMT bars 10 mm dia and over cut to length, bent to shape required including cranking bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete.
M&L for brick work with flyash bricks straight or curved on plan to any radius in half brick thick walls old size bricks built in cement mortar 1:4
M&L Taking down cement plaster on brick or stone walls,ceiling etc. including raking out joints, hacking for key, scrubbing down wih water, etc complete all as specified and as directed
Rendering 15 mm thick on stone masonry surfaces or surfaces other than fair faces of brick work or on one side of lathing in cement mortar 1:6 and finished even and smooth without using extra cement.
Demolition of concrete in ground floors and pavings nexc 15cm thickness(below or above ground level) complete all as specified and as direcetd.
S&F stainless steel sinks with drainage board of 1mm thick in kitchen or laboratory with plug washers and waste pipe including bedding in cement mortar to dwaft wall or including fixing cantilever brackets andover all size 915mm x 460mm bowl size 410mm x 330 mm x 160mm complete as specified and directed.
S&F 32mm waste fitting,brass , CP for glazed ware sinks,basins etc. with long screwed shanks and flynuts, flange end bedded in red lead cement and other end fixedcomplete all as specified.
Supply of Water proofing compound
Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal to store
Supply and laying of 16 mm bore CPVC pipes SDR 11 & plain CPVC SDR 11 on walls/ceiling or laying in floors complete all as specified.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to store
Supply and laying of 20 mm bore CPVC pipes SDR 11 & plain CPVC SDR 11 fittings walls/ceiling or laying in floors complete all as specified.
Taking up or down 25 mm bore steel tubing and connections, including cleaning for Refixing or removal to store
Supply and laying of 25 mm bore CPVC pipes SDR 11 & plain CPVC SDR 11 fittings walls/ceiling or laying in floor complete all as specified.
S&F rotational moulded polyethylene water storage tanks two layered (ISI Marked) 1000 ltrs capacity(cylindrical vertical with closed top) hoisted and fixed in position including dismantling of old tank and removing from site complete all as specified
S&F 20mm dia ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 20mm bore minimum weight 210 gms complete all as specified.
S&F 25mm repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces with CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
S & F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe)including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including 'P' or 'S' trap complete as specified and as directed.
S & F health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 m long flexible tube and ABS wall hook including making connection and fixed in position complete in all respect as specified.
S&F PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float & handle, & brackets complete set all as specified and directed.
S&F vitreous china wash and basin, white, flat back, size 550 mm x 400 mm fixed on existing bracket, fixing of tap, waste fitting, pipe and union complete all as specified and as directed.
Brick work with fly ash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6
S&F CP shower rose with or without swivel joint, any size including fixing to tube complete all as specified and as directed.
S&F 15 mm bore pillar tap, fancy type, cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts screwed for iron pipe fixed. complete all as specified and directed
S&F 15 mm bore CP bib tap of fancy type with long shunk with cast copper alloy of crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule fixed complete all as specified and directed.
S&F 15mm bore CP stop valve with wall flange fancy type with long shunk with cast copper alloy of crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule of concealed type complete all as specified and as directed.Make-Parko/Seiko/Parryware
S&F 15mm bore brass chromium plated towel towel rail 20 mm dia .
S&F PVC connections 15 mm size with PTMT of 450mm long complete all as specified and as directed.
S&F 100mm dia grating doom of PTMT steel complete all as specified and as directed.
M&L PVC (SWR) gully trap 125/110 mm setting & fixing of size 125/110 mm complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with carefully prepare rubber ring joints (or solvent joint) fixed to walls / ceiling or laid in floor complete all as specified and directed
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls / ceiling or laid in floor complete all as specified and directed
S&F 110mm size PVC (SWR) bends any radius complete all as specified and directed
S&F 75 mm size PVC(SWR) bends any radius complete all as specified and directed
S&F 110mm size PVC (SWR) branch piece, single (single Y) equal or unequal with access door.
S & F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door.
S & F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door.
S&F 75mm dia of PVC floor trap plain with grating including jointing with solvent cement of outlet complete all as specified and directed.
S&F in repair to Harrison rails,mild steel,chromium plated with fixing brackets,stops,rollers etc complete all as specified and directed
S&F Factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm wood grain printed PVC sheet reinforced with MS square tube with wooden grain printed PVC sheet used inserted of wood grain colour PVC sheet & edges will be painted to match with printed sheet complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded wood grain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and wood grain pirinted PVC for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of wood grain printed PVC sheet to be fitted in the MS frame welded / sealed to & 5 mm thick x 15 mm wide PVC sheet beading and decorative PVC beading of 10mm x 10mm (90 degree) with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified .
S&F Powder coating anodised aluminium frame for doors, windows, ventilatiors with one or more rebtes including joining cleat for fixing etc. complete all as specified. (Minimum thickness of powder coating 50 micron).
S&F for powder coating of any colour anodised alluminium door shutters sections weight not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing,handles in each door, hinges, anodised aluminium snap beading screws etc, complete all as specified. (Minimum thickness of powder coating 50 micron).
S & F in repairs 12mm thick Prelaminated particle board, exterior grade, prelaminated on both sides with decorative choice lamination fixed with screws to timber frame work complete all as specified and directed.
S & F 4.8 mm thick tinted Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq. M in each pane for cup board, cabinet, racks etc.
Supply only Powder Coated Aluminium Deco Grill of Model / Design No. DG 104 (7.2mmx4.2mm) including Powder Coated Aluminium Channel of size 15 X 10 X 1.5mm for fixing Deco Grill complete all as specified and as directed.
S&F 150mm long anodised aluminium handles, cast type complete all as specified and as directed.
S&F 100 mm size mild steel hinges medium weight complete all as specified and directed
S&F for 150 mm long mild steel barrel tower bolt of extruded section complete all as specified .
S&F in repair 30mm continuous(piano) hinges,mild steel, bright finish or electrogalvanised complete all as specified.
S & F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy.
Preparation of New or previously untreated surfaces of cement or plastered surfaces, of any description and girth, not otherwise described and applying 3mm thick wall care putty and primer on wall surface to achieve even and smooth surface and applying two coats of oil bound distemper on walls.
Material & Labour for applying wall care putty of 1mm thick over plastered surface to prepare the surface even and smooth and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290. Gde-E-165
M&L for 75 mm thick cement concrete 1:3:6 type C-2 using 20 mm graded stone aggregate .
M & L for 100mm thick, PCC 1:2:4, type B-2, using 40mm graded stone aggregate .
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and as directed.
M&L for two coats of synthetic enamel paint on new steel surface exc 10 cm width or girth on 01 coat of primer (Red oxide Zinc chrome) incl preparation of new surfaces complete.
M&L for cement concrete type c-2 (1:3:6) as in plinth protection finishing even and smooth without using extra cement complete all as specified and as directed.
M&L for PCC (1:3:6) type C-2 using 40mm graded machine crushed stone aggregate as in foundation.
S&F 15mm mm bore dia stop valve cast copper alloy screwed down, high pressure with crutch or butter fly handle, screwed both ends for pipe or for unions and fixed complete all as specified and directed.
M&L for brick work with flyash modular size bricks staright or curved on plan to any radius in half brick thick walls builtin CM 1:4 complete all as specified and as directed.
M&L hard core of broken stone or boulders of guage not exc 63mm but n exc 40mm deposited spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete.
M&L for 100 mm thick cement concrete type B-1, 1:2:4 (20 mm graged aggregate) complete all as specified and as directed.
M&L for sand filling under floors or in foundations incl watering and consolidation complete al as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80 mm thickness M-40 grade with grey cement and no pigment complete all as speicified and as directed
M&L preparation of new plastered surface and three coats of white wash complete all as specified and as directed
M&L for providing precast cement concrete type B1 1:1.5:3 (20 mm graded aggregate) in landings cover slabs, (for manholes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and setting in mortar CM 1:4 complete with joints to match complete all as specified and as directed.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and with WPC @ 2% finished even and smooth without using extra cement.
M&L for 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints ,laid in trenches or in floors complete all as specified and as directed
SCHEDULE 'A' PART-II:E/M WORKS
M & L for point wiring with 3 runs of 1.5 Sqmm PVC insulated and stranded copper cable 1100V, FRLS grade multistranded drawn in and including 20mm PVC conduit / casing caping /concealed PVC conduit on/in walls/ceiling with tee, bend, elbows , junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable module for fixing modular switches, sockets, regulator and connected the earth wire to common earth dolly for One light / fan point / bell point / 5 Amps socket piont same board controlled by one switch Note:-(i) The quoted rate shall includes all the cost of cutting, chasing, cementing work and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour.
Description all as per item No. 96 above but for 5Amp switch socket out let, independent , complete all as specified and directed.
Description all as per item No. 96 above but for 15/16Amp switch socket out let, independent with 4 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified and directed.
Material and labour for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including 25mm surface stove enamel steel conduit in walls/ceiling with tee, bend, elbows,junction box end clousers etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity suitable for flame proof switches, sockets regulator and connected the earth wire to common earth dolly for One light point/fan point controlled by one switch complete all as specified and as directed.
S & F in Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge.
S & F in Modular switch 1 way 16A, 1 module single pole complete all as specified and directed by Engr-in-charge.
S & F in of Socket, 6A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified and directed.
S & F in of Socket 15A/16A - 2/3 pin combined 2 module, 230 volt,multipurpose, complete all as specified and directed.
S & F in of modular Fan step regulator, 120W - 1/2 module as per site requirement, complete all as specified and directed.
S & F in bell push modular, one way 6 Amps, 1 module 230V complete all as specified and directed.
S & F in calling bell Ding dong, AC 230 volts single pole, complete all as specified and directed.
S & F in ceiling rose surface bake lite 65 x 30 mm with 3 terminals complete all as specified and directed by Engr-in-charge.
S & F in Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up driver with three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete including testing after completion all as directed by Engineer in charge
Supply and fix LED light fitting 1 x 16 watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed.
Supply and fix flame proof exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including making suitable hole for fixing Exhaust fan complete all as specified and directed. (For New Provn)
S&F Modular single pole and neutral enclosure with two pin and earth plug and socket complete including with one SPN MCB 20 Amps capacity.
S & F in Building Security light LED type of 4500 Lumens (45 W) Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted incluidng taking down old unsv fittings complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 12 Way, DD, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified and as directed.
Supply and fixing of MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified and as directed.
Supply and fixing of MCB 6 to 32Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, complete all as specified and as directed.
Supply and fixing of RCBO DP 30mA, 32A , 415 Volt, complete all as specified and directed.
M&L for sub main wiring with two run of 4.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4.0 Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, complete all as specified and as directed. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
Supply lay and testing of cable in trenches/walls XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 25sqmm 4.0 core complete all as specified and directed by Engr-in-charge.
M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with GI earth wire of 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber,CI frame with CI 10mm thick cover, 20mm dia GI medium grade pipe for watering , and water funnel with wirw mesh, 20mm dia light grade GI pipe for protection of strip complete all as specified and testing on completion.
Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified
Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Material and labour for natural river sand as cushioning of cables, including spreading and punning down complete all as specified and directed by Engineer in charge. Note : punned thickness shall be measured for payment purpose
Supply, install, testing and commissioning of hi wall split type air conditioner of capacity 1.5 TR units indoor unit / outdoor unit complete with cordless remote control unit ,copper winding compressor, copper condensor coil ,drain pipe for better indoor air quality with minimum 5 star rating and EER 3.2 complete all as specified and directed by the Engineer-in-Charge. (Note :- 1. Rates for 5 years onsite replacement warranty is included in quoted rate. 2.The rate for fixing of brackets/stand for indoor and outdoor unit in wall of any height deemed to be included in rate quoted. 3. The copper tube of suitable size (for each ACs), Drain pipe, cables with plug top are included in quoted rate. 4. Provision of passing of copper tubes from wall by machine core cutting in any type of wall are included with quoted rate.)
S & F voltage stablizer for automatic operation, sigle phase naturally air cooled indoor type & designed for input varitation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ( + / - ) 2.5% and of capacity 4.0 KVA
Supplying, installing testing and commissioning of Analogue Addressable type Single Loop Fire Alarm Control Panel with 99 detectors & 99 Modules & up to 200 Detectors and Modules per each loop, expandable Up to 1000 fire detection zones, with UL/ULC/ LPCB/ FM listed and complying with BS EN 54 Parts 2 and 4 along with Network interface Card and Lead Acid Battery backup for 08 Hours normal operation and 15 minutes alarm operation, the control panel, battery charger including provision of protective cover as and where required and taking down existing old panel of any description and type complete all as specified and as directed and consistiong of lthe following features:-
Note: The rate quoted shall also deemed to include for the following provisions also:- [i] Supply and installation of Batteries 12v 18/07 Ah - 02 Nos [ii] Supply and installation of 24 volt Fault Torrent Network card/ OLYNET/ ONERING with bulit in diagnostics and is fully monitored for both short and open circuit faults between nodes installed in fire alarm panel with maximum 200 Network nodes. [iii] Fire detection and alarm system connected with Compatible GSM/PSTN auto dialer alongwith activated Sim for easy communication with pre recorded messages to stored phone numbers - 1 Set Make: Compatible with Honeywell, Notifier, Apollo Discovery, Argus Vega, Hochiki ESP and Nittan Evolution protocols
Supply installation & testing and commissioning of GSM communicator which converts the Contact ID codes of the fire alarm panel’s PSTN communicator. For central alarm monitoring: GSM Communicator is special for converting the PSTN Adecco Contact ID codes to readable SMS notifications and SIA-09 IP over GPRS network to central monitoring station (CMS). Available in 2G/3G/4G/LTE mobile network versions. Fire detection and alarm system are to be connected with GSM Module with 2/4G GSM version of. 2G QUAD BAND (850/900/1800/1900 MHz). Direct mount Antenna with SMA Male L-Type Connector – CDMA and WCDMA, 2.5 dBi Gain and 850-2100/2400 MHz. IP communicator for fire alarm control panels, Supports full transmission Contact ID over IP SIA-DC09 event information to security monitoring station. 4/8 general alarm inputs including power supply voltage monitoring via SMS messages,800 remote control users via free short call,800 users control by GSM call or using maxim- Dallas I Button keys, Configuration using standard mini-USB cable Remote configuration and firmware upgrade, Easy installation.
Testing and diagnostic of the module via USB by using program SOFTWARE. Very useful features are troubleshooting and testing of the module via USB PC; this saves time for installer and allows real-time monitoring of module parameters, input/output and GSM modem status (IMEI, SIM, registration) etc. Supports up to 32 temperature sensors or 1 humidity/temperature sensor for automation purposes such as HVAC temperature control, alarm, and control – Optional with extra senser.Free configuration and diagnostic software, Free android APP and WEB Cloud service with Software for Mobile / Tab’s / PC’s. -1Set with each panel (Mobile / Tab’s / PC’s at extra cost). To be connected with existing fire alarm system at various units. Central alarm monitoring at security through cloud-based software (With out ant receiver) with PC/TAB (PC / TAB at extra cost). Make: compatible with Existing Apollo/ Cooper/ Notifier/ Honeywell protocol Fire alarm panel as per international communication protocol standards.
Supply, fix and testing of Addressable single action manual call point, resettable type, having integrally mounted addressable module to monitor and report contact status complete all as specified and as directed.
Supplying, installing and testing of Multisensor Detector with self built intelligence Complying with and type certified to EN 54 and conforming to IS - 11360 comprising of optical smoke and thermistor temperature sensors, to give both combined signal as well as a separate heat signal for improved false alongwith isolator modules as required, provided as per area requirment below or above the false ceiling including taking down old detectors of andy descrition and type complete all as specified and as directed and with following specifications:-
Communications protocol: 5-9V peak to peak Operating voltage: 17-28V DC Quiescent current: 500µA average 750µA peak Power-up surge current: 1mA Maximum power-up time: 10s Alarm LED current: 3.5mA Remote LED current: 4mA at 5V (measured across remote load)
Clean air analogue value: 23 +4/-0 Alarm level analogue value: 55 Alarm indicator: 2 colourless LEDs; illuminated red in alarm Optional remote LED Dimensions: 100mm diameter 50mm height 58mm (height in base) Weight: Detector: 105g Detector in base: 160g Materials: Housing: White polycarbonate V-0 rated to UL94 Terminals: Nicket plated stainless steel Smoke element only: Cahmber configuration: Horizontal optical bench housing infra-red emitter and sensor, arranged radially to detect forward scattered light Sensor: Silicon PIN photo-diode
Supply and installation of UV Flame Detector with air Purging provision, Flickering LED indication for normal operation 24V DC, 4 Wire system with IHMB01XY complete all as specified and as directed.
Supply & Installation and Commissioning of Short circuit isolator module to be installed between every 20 nos. of devices to isolate the circuit from single short circuit on the analogue addressable loop cable, this is non addressable device with yellow LED for status indications, including all accessries all as specified and directed by Engr-in-Charge
Supplying, installing and testing of Addressable electronic loop sounder cum strobe alongwith in-built isolators complete all as specified and as directed.
Supply, lay, test and commissioning of 2 Core, 1.50 Sq.mm, PVC Insulated and PVC sheathed, heavy duty cable, ISI marked with Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked complete all as specified and as directed.
Supply and Laying of 20mm Stove enamelled rigid steel conduit for Surface area Including Bends, Junction Boxes,couplings, Base Saddles, Screws Etc all as specified and directed by Engr-in-Charge
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 KVA
G Srinivas Rao (BID ID -3288329)
K.ADITYA ENGINEERING CONTRACTORS (BID ID -3291065)
venkata sai constructions (BID ID -3294176)
SATYAMEGHA ENGINEERS (BID ID -3291185)
SRI THULASI TECH (BID ID -3291215)
NAVEEN INFRASTRUCTURES (BID ID -3291157)
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .