| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹26.2 L+₹63,080.05 (2.47%)Rejected-Finance 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹26.5 L+₹95,050.89 (3.72%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹26.6 L+₹1.0 L (4.05%)Rejected-Finance 17 NO TIKIA MAHAL ORDERLY BAZAR PO PS BARRACKPORE DIST 24 PGS KOLKATA 700120 WB | KOLKATA | 24 PGS | WB | 700120 | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹26.7 L+₹1.2 L (4.78%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
4 Jul 2020, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
SPECIAL REPAIR TO BLDG NO. PB-68 INCLUDING PATH AT NEW COLONY AND SPECIAL REPAIRS TO BLDG NO. NP-33 AND PROVN OF BLDG SECURITY LIGHTS AT KANCHRAPARA UNDER GE BARRACKPORE
2020_MES_352993_1
8420/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
2 documents required · 2 mandatory
₹500
GE Barrackpore
₹54,000
Yes
5 Oct 2020
15 Jun 2020
6 Jul 2020
15 Jun 2020
4 Jul 2020
29 Jun 2020
Amount
Taking down chowkats with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm each all as specified and directed.
Taking down chowkats with shutters (without taking off shutter from the frames) exceeding 1.50 Sqm and not exceeding 4.00 Sqm each complete all as specified and directed.
Taking down of shutter of any description exceeding 1 Sqm and not exceeding 2.0 Sqm each all as specified and directed.
Taking down of shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm and refixing in same opening after easing and adjusting all as specified and directed.
S&F for factory made steel windows with side hung shutters including box type hinges with steel handle, frame, steel peg stay, complete with glazing bars, dovetailed or welded to receive wire mesh/glass including one coat of red oxide zinc chrome primer at factory complete all as specified and directed.
S&F for factory made steel windows with side hung shutters including box type hinges with steel handle, frame, steel peg stay, complete without glazing bars, dovetailed or welded to receive wire mesh/glass including one coat of red oxide zinc chrome primer at factory complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over and including a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
S&F for pressed steel frames (factory made) for door of size 125mm X 60mm of 1.25mm thick with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded crushed stone aggregate) with and including applying of two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed.
S&F for pressed steel frames (factory made) for door of size 105mm X 60mm of 1.25mm thick with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded crushed stone aggregate) with and including applying of two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed.
S&F for 35mm thick, second class hard wood plain frames, panelled (factory made) shutters with lock rails and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS-1003 (Part-I) (larger size to be provided) klin seasoned and chemically pressure treated fitted to chowkats complete all as specified and as directed.
S&F for 35mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made), open rebated & prepared to receive glass, gauge etc. (with sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR part-I, section-8, clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm in width or girth complete all as specified and directed.
S&F for factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube as per specification and drawing complete all as specified and directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified and directed.
S&F for pressed steel frames for doors/windows of size 75mm X 50mm of 1.25mm thick with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded crushed stone aggregate) back of chowkhats and including two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed.
S&F for 18/19 mm thick prelaminated particle board as in kitchen cabinet, cupboard shelves & shutter interior grade, prelaminated in one side with decorative choice lamination solid core medium density general purposes, and other side white lamination fixed with screw including teakwood lipping complete all as specified and directed.
S&F for 18/19 mm thick prelaminated particle board as in kitchen cabinet, cupboard shelves & shutter interior grade, prelaminated in one side with decorative choice lamination solid core medium density general purposes, and other side white lamination fixed with screw including teakwood lipping complete as in repair all as specified and directed.
S&F for 18 to 20mm thick PVC solid board with one side decorative choice laminate and other side balancing white as in kitchen cabinet, cupboard etc fixed with screws to steel/timber frame work etc complete as in repair all as specified and directed.
Hacking out old broken glass (any thickness size quality or description) from wooden or steel frame, glazed with putty or fixed with beads etc complete all as specified and as directed.
S&F for stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple complete all as specified and directed.
S&F for stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple complete as in repair all as specified and directed.
S&F for 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F for 3.0mm thick frosted sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F for 100 mm long stainless steel butt hinges, medium weight complete all as specified and directed.
S&F for 50 mm long stainless steel butt hinges, medium weight complete all as specified and directed.
S&F for 250 mm aluminium , sliding door bolt with sand or die cast brass hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts fixed complete all as specified and directed.
S&F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F for second class hardwood small fittings such as brackets of any type, latch and hinge blocks, shapes door and window stops and the like including all necessary articles not exceeding 200 Cucm each all as specified and as directed.
S&F for peg set of six, brass fixed with chromium plated brass screws and wooden and plastic cleats (minimum weight 190 gms) complete all as specified and approved by GE
S&F for 100 mm long hasp and staple, mild steel, wire type, stove enamelled, black including bolt to hinge plate and fixed with screws complete all as specified and directed
S&F for 25mm bore mild steel powder coated, single curtain rod (wall thickness not less than 1mm) including PVC powder coated brackets, funnels etc suitable for single curtain rod, fixed etc complete as in repair all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:3) on ceiling surfaces, finished fair and even complete all as specified and directed
M&L for rendering 15mm thick in cement mortar (1:4) on brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:3) on facia/edging/ceiling of chajjas, roof projections etc, including and making the line in true shape and finishing the surfaces without using extra cement complete all as specified and directed
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls and chajja including preparation of surface complete all as specified and directed.
M&L for applying two coats of distemper oil emulsion after applying 2 mm thick wall care putty after preparation of newly plastered surfaces of walls complete all as specified and directed.
M&L for applying three coats of white wash on surface of wall including preparation of new plastered surface complete all as specified and directed.
M&L for applying three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and directed.
M&L for applying two coats of oil bound distemper over 2 mm thick wall care putty on wall as directed by GE as per site condition after complete removal of existing treatment of wall including preparation of old painted wall surfaces complete all as specified and directed.
M&L for applying one coat of white wash on old decorated wall surfaces after preparation of old plastered surfaces complete all as specified and directed.
M&L for one coat of white wash on ceiling surfaces after preparation of old plastered surfaces complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistant primer on old plastered surface of walls after complete removal of existing treatment complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors & pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in plinth protection/paving including finishing the cement concrete surface even and smooth without using extra cement in slope including making joints of every 2.5m and at corner filled with bitumen 85/25 and sand in ratio (1:2) by weight and complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in subbase of floor complete all as specified and directed.
M&L for 60mm thick machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2008 (M-35 grade) over 25mm thick compacted sand cushioning including watering and consolidation complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping, clean and washing down with water to remove, dust etc complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured (colour & shade as approved by GE) tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in colour cement to match over and including 15mm thick Screed bed or beading layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
All as per Item No.57.00 here-in-before but in skirting/dado/riser over and including a backing coat of 10mm thick plater in cement mortar (1:4) complete all as specified and directed.
M&L for glazed ceramic coloured tiles (colour & shade as approved by GE) in vertical surface of size 450mmX 300mmX7 to 8mm thick set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed of cement mortar (1:6) complete all as specified and directed.
M&L for machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10mm cement screed bed in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 20mm thick granite (any type) work (table rubbed and polished) machine cut in steps, jambs, pillars, window cill, cooking platform etc bedded and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust with admixture of pigment to match the granite stone including and polishing over and including 15mm thick cement mortar (1:4) complete all as specified and directed.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations not exceeding 15mm wide complete all as specified and directed.
Demolition of reinforcement cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed.
M&L for precast reinforced cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in cover slab/slab of drain/manhole water tank/shelf, landing, cooking platform, chullah hoods, chajja & similar articles etc set in cement mortar (1:4) complete all as specified and directed. (NOTE: Cost of Form Work is deemed to be inclusive of unit rate quoted by the contractor & reinforcement shall be measured & paid Separately.)
M&L for TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns (as in stirrups), hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description etc complete all as directed.
S&F for mild steel wind ties for roofing including screwing bolts with steel structure including cutting, drilling holes etc conforming to Fe-290 Gde-E-165 complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi-corrugated etc.) sheets in roof coverings complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet all as specified and directed.
Dismantling timber scantlings (framed work) 40 sq.cm and over in section, in any position complete all as specified and directed.
Dismantling timber in fillets, rails posts, rafters, purlins etc under 40 Sqcm in section complete all as specified and directed.
S&F for false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee gird false ceiling using “T” Gird System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board (oceanic) of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T gird Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Gird module to form complete as per the drawing & directions of Engineer-in-Charge.
Taking up or down steel tubings & connections including cleaning for refixing or removal from site for 15 mm bore pipes complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor etc.) for 15mm bore pipes with new fittings etc complete all as specified and as directed. (Note : Pipe shall be obtained from Item No 75.00 above)
S&F for 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
Taking up or down steel tubings & connections including cleaning for refixing or removal from site for 20 mm bore pipes complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor etc.) for 20mm bore pipes with new fittings etc complete all as specified and as directed. (Note : Pipe shall be obtained from Item No 78.00 above)
S&F for 20mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
S&F for 15 mm dia angular stop valve cast copper alloy, chromium plated, fancy type, screwed down high pressure with wall flange complete as in repairs all as specified and directed .
S&F for 15mm dia bib taps, cast copper alloy, fancy type, chromium plated with flange complete as in repairs all as specified and directed.
S&F for vitreous china wash basin, white, flat back, size 550 X 400mm, excluding taps, chain and plug and porcelain stopper but including 32mm dia PVC waste pipe, brackets (02 Nos), 32mm size full threaded brass chromium plated waste coupling etc and cutting for and pinning in ends of brackets or erecting stand complete as in repair all as specified and directed.
S&F for 15mm dia pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes complete as in repair all as specified and directed.
S&F for brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges as in repairs all as specified and as directed.
S&F for 125mm size brass chromium plated shower roses with arms, swivel joints, including fixing to steel pipe or union complete as in repair all as specified and directed.
S&F for shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete as in repairsall as specified and directed.
S&F for vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests with P or S trap (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floors with PCC bedding (1:5:10) type E2 using 40mm nominal brick ballast and connection to trap with cement mortar all as specified, and making good to floor including demolition of PCC / lime concrete bedding existing pan complete as in repairs all as specified and directed.
S&F for 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete as in repair all as specified and directed.
S&F for PVC connection pipe 15 mm size with PTMT nuts of length 600 mm complete as in repair all as specified and as directed.
S&F for 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer) hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection, including 15mm ball valve high pressure of PTMT including dismantling / taking down old PVC water tank, ball valve etc complete all as specified in SSR Part-I all as specified and directed.
S&F for 20mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe & fixed (minimum weight 210 gms) complete as in repairs all as specified and directed.
S&F for 20mm dia gun metal gate valves with iron wheel head screwed both ends for iron pipes or for unions pipes, fixed as in repairs all as specified and directed.
S&F for sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or in and including fixing cantilever brackets, waste coupling, waste pipe and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete as in repair all as specified and directed.
S&F for stainless steel plate rack of 1mm thick of best quality as approved by GE of size 900mmX600mm X250mm complete as in repair all as specified and directed.
S&F for 100mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, laid in trenches or in floors complete all as specified and directed.
S&F for 100mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, fixed in wall with clamps and cement joints complete as in repair all as specified and directed.
S&F for 100 mm dia cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) complete as in repair all as specified and directed.
S&F for 100mm dia CI branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access door complete as in repair all as specified and directed.
S&F for 75 mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, laid in trenches or in floors complete all as specified and directed.
S&F for 75 mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, fixed in wall with clamps and cement joints complete as in repair all as specified and directed.
S&F for 75 mm dia cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) complete as in repair all as specified and directed.
S&F for 75 mm dia cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) fixed with oval access door complete as in repair all as specified and directed.
S&F for 75 mm dia CI branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access door complete as in repair all as specified and directed.
M&L for 100mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete as in repair all as specified and directed.
S&F for 100 mm cast iron cowls complete as in repairs all as specified and directed.
S&F for salt glazed stone ware gully trap of size 150mmX150mm square or round moulded type 'P' complete as in repair all as specified and directed.
Demolition of cement concrete (un-reinforcement) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) averaging 50mm thick as in roof padding / levelling course with WPC @ 2% by weight of cement complete all as specified and directed. (Note : WPC shall be measured and paid separately).
M&L for rendering 15mm thick on concrete surfaces in RCC roof surfaces with cement mortar (1:4) with WPC @ 2% by weight of cement finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately)
S&F for box type steel hinges (for window) including necessary fixing and welding, cutting of existing hinges etc complete all as specified and directed
S&F for MS handles for steel windows with necessary notch for arragement to suit the existing window (left/right) complete all as specified and as directed
M&L for machine cut kota stone slab flooring (pre-mirror polished) 20-25mm thick over and including 15mm thick screed bed of cement mortar (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including dismantling of old kota stone slab all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in surface channel and drains etc complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
M&L for rendering 20 mm thick, 1st coat 10mm thick in cement mortar (1:6) & 2nd coat 10mm thick in cement mortar (1:4) with water proofing compound @ 2% by weight of cement, plastered surface shall be finished even and fair with using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately, WPC shall be used in second coat only)
Supply only integral water proofing compound, ISI marked complete all as specified and directed.
M&L for two coats of white wash on old decorated plastered surfaces after preparation of old plastered surfaces all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) used as in brick, concrete wall for fixing of hold fast including necessary form work complete all as specified and directed.
S&F for bands, straps, supports or stays for rainwater, ventilating pipes including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fast, wind ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-e-165 complete all as specified and directed.
M&L for sub main wiring (concealed) complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty including cutting and cheasing complete all as specified and directed after taking down existing sub-main wiring of any type/size from wall and making good disturbed surface. (Note : Two run of 6 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit)
M&L for sub main wiring (concealed) complete with 2 run of 1.5 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 20mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 1.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty including cutting and cheasing complete all as specified and directed. (Note : Two run of 1.5sqmm single core copper conductor cable and one run of 1.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit)
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with the existing surfaces and applying white/ colour wash/distemper after applying putty for smooth finish surface complete all as specified and directed.
M&L for point wiring (concealed) complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box of 1.20mm thickwith top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of bakelite laminated top cover of 3mm thick , blanking plate as per numbers of switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures accessories and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers and all modular electrical fixtures are to be used same make/brand only and shall be deemed in to included in quoted rate only.)
One light point controlled by one switch .
One light point controlled by two Nos two way switches .
One fan point/ exhaust fan point controlled by one switch. .
One 3 pin 5/15 amps socket outlet point on same board.
One 3 pin 5/15 amps socket outlet point on independent board.
One bell/buzzer point controlled by one bell push.
All as per Item No.125.00 here-in-before but point wiring with 4.0sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of 3 pin, 15 Amps socket outlet on independent board complete all as specified and directed .
S&F for decorative box type 20 watt/22 watt LED fitting of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible conductor cable of 0.50 Sqmm size and including mounted on PVC/Wooden round/square blocks-02 Nos including removing old unserviceable light fittings complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DIJB12LT8-20 as approved )
S&F for 20 watt linear LED T8 tubular lamp with extruded aluminium/polycarbonate body and polycarbonate diffuser complete with inbuilt driver complete all as specified and directed. (Make: Crompton Greaves Cat No LTT8-20 /Havells Cat No TL20WLED865SPC OR PHOTONULTRA1213T8SSTL20WLED865 SPC as approved)
S&F for angle lamp holder, insulated body with back plate for batten fittings in and including LED lamp 12 watts complete all as specified and directed. (Make: Havells/Anchor/Legrand as approved)
S&F for stepped type (0-4/5 step) electronic fan regulator for ceiling fan 1200 mm, 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing complete all as specified and directed.
S&F for call bell, AC, 230 Volts single pole, multi music type ISI marked complete as in repair all as specified and directed.
S&F for bell push switch, single pole, one way, flush type, 6 Amps, 240 volts, ISI marked complete as in repairs all as specified and directed.
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, AC, ISI Marked complete all as specified and directed.
S&F for switch piano flush button single pole one way, 5/6 amp 240 volts, AC, ISI marked complete all as specified and directed.
S&F for switch piano, flush type, single pole, two way, 5/6 Amps, 240Volts, AC, ISI marked complete all as specified and directed.
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 and15/16 Amps, 240 volts, AC, ISI marked complete all as specified and directed.
S&F for switch piano flush button single pole, one way, 15/16 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F for ceiling rose , surface bakelite 65X50mm, three terminal, PVC/polycarbonate body complete all as specified and directed.
S&F for rectangular block for mounting switches, sockets, fan regulator, tub light fittings, ceiling rose etc with 3mm thick plastic laminated sheet cover of size 100mmX100mmX50mm deep complete all as specified and directed.
S&F for powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 4 way suitable for flush mounting with 200 amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100 Amps, MCB TPN/DP and MCB SP, 10KA as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete as in repair all as specified and as directed. (Make:- Legrand cat No. 5076 80 4 way / Hager Cat No.VYT04GH/ L&T Cat No. DBTPE004GD as approved)
S&F for MCCB, 63 Amps, 4 pole, 415 Volts, 50 KA, 'C' Series, AC, 50 Hz, ISI Marked complete all as specified and as directed. (Make:Legrand /Havells /L&T as approved)
S&F for FR-LSH PVC insulated (unsheathed) single core, multistrandad copper cable 10 Sqmm from MCCB to TPN DB complete all as specified and directed.
S&F for MCB, 100 Amps, 4 pole, 240 Volts, 10 KA, 'C' Series, AC, 50 Hz, ISI Marked complete all as specified and as directed. (Make:Legrand /Havells /L&T as approved)
S&F powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete as in repair all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way / Hager cat No.VYS08G / L&T Cat No.DBSPN008GD as approved)
S&F for MCB, double pole, 40 Amps, 10 KA, "C" series, AC, 240 Volts, 50Hz, ISI marked complete all as specified and directed. (Make: Legrand / Hager / L&T as approved)
S&F for MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 5 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. (Galvanised strip upto 7.5m including testing consider in this item).
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 35 sqmm, 3.5 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable service cable complete all as specified and directed . (NOTE: Excavation/earth wall, sand cushioning, cable cover/brick shall be measured and paid separately if required)
Supply, fabricated and fixing of street light bracket made out of GI pipe 1.0 Mtr long, 32mm dia medium grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer complete after taking down old unserviceable bracket all as specified and directed.
S&F for LED secruity light fitting of capacity 70w/72w LED street light fitting with LED lamps in aluminium PDC housing, toughened glass cover with IP65 protection with 4 KV inbuilt surge protector and cable connection from looping box to light fitting and testing and including removing of old unserviceable fittings complete all as specified and directed. (Make:- Crompton cat No.LSTP-72-CDL/Havells cat No.ENDURAPEARLPLUSSL70WLED757SASYTOPC as approved
Taking down ceiling fan of 1200/1400 mm sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, connecting wire from ceiling fan, ceiling rose or connection complete all as specified and directed.
Taking down existing electric meter carefully from the meter box and re-fixed the same in the existing or new location including supply and fix PVC enclosed for meter box alongwith suitable cut out complete all as specified and directed.
M&L for fixing of PVC insulated FR-LSH cable with multistranded copper conductor 1100 volt grade of size 6 sqmm for connection from MCB to electric meter by using clips in meter box complete all as specified and directed after taking down existing cable of any type and any size. (Note : Two run of 6Sqmm copper cable shall be measured as one unit length)
M&L for boring holes horizontally under road without damaging the surface of road (minimum 1.0m bellow the road surfaces) with the help of GI tubing of any dia not exceeding 80mm dia for passing of UG cable complete all as specified and directed.
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed
Excavation in trenches for laying under ground cable, foundation, erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points as in soft/loose soil all as specified and directed.
M&L for brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
S&F for LED street light fittings Indus series IP-65 powder coated pressure die cast aluminium compact high power LED street light with heat resistant toughened glass of capacity 40 watt with LED lamp complete as in repair all as specified and directed . (Make : Crompton Greaves Cat No LSTS-40-CDL/ Havells Cat No ENDURAPEARLNEOSL40WLED757PASYTOPC as approved)
M&L for GI pipe 40mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, on wall, floors, on roof, on pole for cable protection complete all as specified and directed.
M/S H.P Singha
M/S KARTICK CHANDRA CHAKRABORTY
B N ENTERPRISE
BHUPENDRA LAL CHAKRABORTY
ABHISHEK CONSTRUCTION CO
INDUSTRIAL CONSTRUCTION
R.S. COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .