| 1 | L1₹46.2 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹60.3 L+₹13.5 L (29.0%)Rejected-Finance INFRA HOUSE CHURCH ROAD PALLINADA ERNAKULAM KERALA 682025 | ERNAKULAM | KERALA | 682025 | L2 | Rejected-Finance L2 Rejected |
Tender Value
₹50.3 L
EMD Value
₹50,000
Closing Date
23 Feb 2024, 2:00 pmClosed
Regional Engineer Trivandrum
Regional Engineer Trivandrum
Re-tender Supply Installation Testing and commissioning of Lifts 2 nos and associated Electrical works at Revenue Towers of Pathanamthitta Division
2024_KSHB_658950_1
2023_RE_KSHB_THU_02(Ele)_1(a)
Open Tender
Electrical Works
Item Rate
60 days
Pathanamthitta
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,100
₹50,000
19 Sept 2024
15 Feb 2024
24 Feb 2024
15 Feb 2024
23 Feb 2024
15 Feb 2024
Amount
APPENDIX-1 LIFT at ADOOR RT
od216277/2023_2024 : Supply, erection, testing, and commissioning of V3F passenger cum freight lift 15 Person capacity suitable for installing 2150 MM X 2000 MM as per the Actual size of the lift well at the site and the following requirements. Number of Openings from cellar + Ground to four floors (G+1+2+3+4+5) Full Height Infrared Light curtain in the car door safety in full length. Door open and door close Buttons. Separate fan switch with timer cut off in the car. Indication of car and Landing call registration, Position indicator in the car, and all landings. Variable speed Door opening and closing time. Inverter-based Emergency alarm bell. 304 grande Stainless Steel Cabin hairline finishing with half-portion glass Height toughened viewing glass suitable thickness of both car and Landing door with frame work etc., and also provide the facilities to fix advertisements on the two sides of the lift wall Signal Fixtures.Car ceiling - Stainless Steel hairline Finish in 304 Grade, Car flooring - Granite Flooring, Car Illumination - LED Light Fittings of approved make, No of the entrance - One Location In Front, Car entrance - Automatic Centre Opening Doors in Stainless Steel Finish in 304 Grade, Door safety - Full-Length Infra-Red Light Curtain, Landing Entrance Automatic Side/Center Opening Doors in SS Stainless Steel Finish in 304 Emergency LED Lights supported with an inverter. Call registering micro push button. intercom system, Door Pressure Limit Switch (Enhanced Door Safety). Serial communication-based LCE Controller. Special features Battery-operated rescue device for power failure Braille buttons for car and landing Lift Floor Announcement system Intercom. Speed 1.00 Meter/Second Type of Drive Variable Voltage Variable Frequency (VVVF) Imported. Location of Machine Room Above the Lift Well. Machine Motor Unit Three Phase, Induction Motor, 415V Location of Machine Room Above the Lift Well. with the warranty period, the rate shall be quoted by you with a 5-year AMC after completing the DLP Overload protection. Granite Flooring, SS handrail, etc., complete as per EI & KSEB rules. Necessary lift Approval and License and insurance shall be obtained from the EI as per the Contractor's scope and it should continue in the AMC period; the Elevator shall be designed in line with the recommendation continued in the latest edition of applicable Indian Standards. The design / Construction /Installation codes shall confirm the latest edition of IS:14665(All parts) and also meet any additional requirements of IS: 4666, IS : 1860 and I S : 3534 and any other equivalent code
APPENDIX- II ADDITIONAL ELECTRICAL WORK FOR LIFT WELL AT ADOOR RT
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required.
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.3 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
od216278/2023_2024 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof FP enclosure Outdoor purpose (IP 66) for independent mounting of Isolator/ RCCB/ RCBO. It is suitable for one number 2 pole Isolator + one number 2 pole RCCB and facility to connect input and output cable Etc complete
od216279/2023_2024 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof FP enclosure Outdoor purpose (IP 66) for independent mounting of Isolator/ RCCB/ RCBO. It is suitable for one number 4 pole Isolator + one number 4 pole RCCB and facility to connect input and output cable Etc complete
od216280/2023_2024 : Supplying and fixing the following rating, four poles, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100mA in the existing MCB DB complete with connections, testing, and commissioning, etc. as required.100 amps
od216281/2023_2024 : Supply,providing,testing and commissioning of 7W to 9 W PWD Approved make LED Bulb<br>
2.1.4 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.125 Amp TP & N
APPENDIX-3 LIFT at Thiruvalla RT
od173515/2023_2024 : Supply, erection, testing, and commissioning of V3F passenger cum freight lift 13 Person capacity suitable for installing 1900 X 2500 mm as per the Actual size of the lift well at the site and the following requirements. Number of Openings from cellar + Ground to four floors (C+G+1+2+3+4) Full Height Infrared Light curtain in the car door safety in full length. Door open and door close Buttons. Separate fan switch with timer cut off in the car. Indication of car and Landing call registration, Position indicator in the car, and all landings. Variable speed Door opening and closing time. Inverter-based Emergency alarm bell. 304 grande Stainless Steel Cabin hairline finishing with half-portion glass Height toughened viewing glass suitable thickness of both car and Landing door with frame work etc., and also provide the facilities to fix advertisements on the two sides of the lift wall Signal Fixtures.Car ceiling - Stainless Steel hairline Finish in 304 Grade, Car flooring - Granite Flooring, Car Illumination - LED Light Fittings of approved make, No of the entrance - One Location In Front, Car entrance - Automatic Centre Opening Doors in Stainless Steel Finish in 304 Grade, Door safety - Full-Length Infra-Red Light Curtain, Landing Entrance Automatic Side/Center Opening Doors in SS Stainless Steel Finish in 304 Emergency LED Lights supported with an inverter. Call registering micro push button. intercom system, Door Pressure Limit Switch (Enhanced Door Safety). Serial communication-based LCE Controller. Special features Battery-operated rescue device for power failure Braille buttons for car and landing Lift Floor Announcement system Intercom. Speed 1.00 Meter/Second Type of Drive Variable Voltage Variable Frequency (VVVF) Imported. Location of Machine Room Above the Lift Well. Machine Motor Unit Three Phase, Induction Motor, 415V Location of Machine Room Above the Lift Well. with the warranty period, the rate shall be quoted by you with a 5-year AMC after completing the DLP Overload protection. Granite Flooring, SS handrail, etc., complete as per EI & KSEB rules. Necessary lift Approval and License and insurance shall be obtained from the EI as per the Contractor's scope and it should continue in the AMC period; the Elevator shall be designed in line with the recommendation continued in the latest edition of applicable Indian Standards. The design / Construction /Installation codes shall confirm the latest edition of IS:14665(All parts) and also meet any additional requirements of IS: 4666, IS : 1860 and I S : 3534 and any other equivalent code<br>
APPENDIX- II ADDITIONAL ELECTRICAL WORK FOR LIFT WELL at Thiruvalla RT
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required.
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.3 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
od173562/2023_2024 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof FP enclosure Outdoor purpose (IP 66) for independent mounting of Isolator/ RCCB/ RCBO. It is suitable for one number 2 pole Isolator + one number 2 pole RCCB and facility to connect input and output cable Etc complete
od173563/2023_2024 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof FP enclosure Outdoor purpose (IP 66) for independent mounting of Isolator/ RCCB/ RCBO. It is suitable for one number 4 pole Isolator + one number 4 pole RCCB and facility to connect input and output cable Etc complete
od173570/2023_2024 : Supplying and fixing the following rating, four poles, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100mA in the existing MCB DB complete with connections, testing, and commissioning, etc. as required.100 amps
od173571/2023_2024 : Supply,providing,testing and commissioning of 7W to 9 W PWD Approved make LED Bulb<br>
2.1.4 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.125 Amp TP & N
INFRA ELEVATORS INDIA PVT LTD
Bidder Name
INFRA ELEVATORS INDIA PVT LTD
Axis Elevators
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .