Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 | AJMER | RAJASTHAN | 305001 | Admitted-Finance |
| 2 | Admitted-Finance KATTI GHATI SHIV COLONY ALWAR ALWAR RAJASTHAN 301001 | ALWAR | RAJASTHAN | 301001 | Admitted-Finance |
| 3 | Admitted-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | Admitted-Finance |
| 4 | Admitted-Finance C 488 SC PLOT NO 10 EKTA NAGAR NEAR ANANT LEWIS PUBLIC SCHOOL BANAR ROAD NANDRI PO SARAN NAGAR JODHPUR 342015 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342015 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
30 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) R AND D JODHPUR
AGE (I) R AND D JODHPUR, Defence Laboratory, Ratanada Palace, Jodhpur- 342011
OUT SOURCING OF 33/11KV YARDS RECEIVING AND DISTRIBUTION SYSTEM AT DEFENCE LAB JODHPUR
2020_MES_384254_1
8394/E8
Open Tender
Civil Works
Item Rate
330 days
AGE (I) R AND D JODHPUR
AS PER TENDER DETAILS
10 documents required · 10 mandatory
₹500
AGE (I) R AND D JODHPUR
₹19,000
Yes
12 Nov 2020
7 Oct 2020
2 Nov 2020
7 Oct 2020
30 Oct 2020
16 Oct 2020
8 Oct 2020 - 15 Oct 2020
60 days
Amount
Out sourcing, repair and maintenance of 33 KV / 11 KV HT receiving station from JVVNL to 33 KV yard, Four / Two Pole structure near NTC power house, Ratanada Palace, old IL Power house, MES Office Complex, New married accommodation of JCOs / ORs, AGE (I) Office Sub Stations, Aradhaana Kendra Sub station, BMP Workshop substation including connected items such as Post insulator, Pin insulator, GOD, Drop out fuse, DISC Insulator, Male / Female contact jumpers, Fuse wire, HT VCB 11 / 33 KV, Capacity, Lightening Arrestors, Power factor capacitors, HT VCB 11 KV indoor type battery bank complete with batteries etc. all as directed by Engineer - in - Charge and including below. Maintenance and monitoring of automatic / manual type Power Factor improvement capacitor panels to maintain the power factor to the minimum average value in between the range of 0.95 to 1 throughout, round the clock installed at different locations as given below. (i) Central Workshop Sub Station. (ii) NTC Power House. (iii) Old IL Power House. (iv) VRF AC Plant. (v) AGE (I) R&D Office complex. Note:- (a) 33 KV / 11 KV HT receiving station and Power Factor improvement capacitor panels, various equipment and electrical fittings will be handed over to contactor through an inventory in operation state at the time of commencement of the work for proper accounting and up keep. The taking over of all the items after expiry of contract shall be done as per inventory and any damage loss shall be made good by contractor before payment of final bill. Any dispute regarding Inventory and working condition of equipments the descision of AGE (I) will be final and binding. (b) The work shall be carried out in three shift (round the clock 24 Hrs) Contractor shall employ one semi-skilled electrician per shift . (c) Particular of 33 KV / 11 KV HT receiving station shall be as specified. (d) In case contractor fails to maintain minimum average value of power factor in between the range of 0.95 to 1 recoveries shall be made from RAR / FB at the rate 1% of tarrif bill amount. The contractor will manage material, labour and T&P to Maintain all Sub Stations Monthly to check / replace jumpers if required, PG Clamps with nut bolts, tightening all nut bolts of Channels, Earthings without any extra cost Cleaning of the sub stations / plants (as described below) shall be carried out by the contractor without any extra cost. (i) Cleaning of dusts of all the indoor / outdoor transformers, HT Panels etc. (ii) Clening / Sweeping of walls and floors of Panel rooms, Transformer Rooms, Duty room, Sub Stations etc. (iii) Cleaning / sweeping of surroundings 33 KV Yard, all the four pole stuctures, two pole structures by taking out vegetables, shrubs / bushes etc. (iv)The staff shall maintain log book of electrical supply of 33/11 KV hourly round the clock and shall be put up to JE E/M daily and put up to Engineer-in-Charge weekly.staff shall wear proper uniform indicating name,designation and firm name,If staff found without uniform recovery@500/-staff shall be done from the contractor. (v)Any breakdown shall be rectified after approval from JE/AGE.
Minimum Wage of tradesman for semi-skilled electrician as per prevailing Notification by the Govt of India or State Govt whichever is higher.
Employer's contribution towards Employees Provident Fund as per prevailing Notification by the Govt of India. Note:- The amount against this items shall be payable only after submission of valid and authentic document in support of having paid the requisite amount of EPF for the workmen i.e. proof of payment.
Contribution towards Employees State Insurance as per prevailing Notification by the Govt of India or State Govt whichever is high. Note:- The amount against this item shall be payable only after submission of valid and authentic document in support of having paid the requisite amount of contribution towards ESIC for the workmen i.e. proof of payment.
Contribution towards Bonus as per prevailing Notification/ directions by the Govt of India. Note:- The amount against this item shall be payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen i.e. proof of payment.
Over head & Profit of the contractor on srl No 1.01 to 1.04
Labour welfare cess as per prevailing Notification by the Govt of India.
Note for item No. 1.01 to 1.06 above:- Rate quoted by the contractor against the item No. 1.01 to 1.06 above which corresponds to/ works out to lower than the corresponding minimum rates of wages/ subscription, contribution towards Employees provident fund (EPF), Employees State Insurance Corporation, Bonus; Overhead & profit and labour welfare cess prevailing on the bid submission end date shall be treated as Non-Bonafide and such bid shall not be considered for acceptance.
Re-stringing & tightening of stay wire complete all as specified and as directed by Engineer-in-charge.
M&L for Repairs to GOD and Drop out fuse unit set , 9/12 insulator type complete including replacement of all UNSV jumpers, copper lugs, nut bolts, greasing,changing of U clips of horizental/vertical brass clamps, changing of copper strips from 11/33 KVA all movable portion complete including necessary adjustment complete all as specified and directed by Engineer-in-charge.
M&L for Straight Through joint out door (heat shrinkable ) for XLPE insulated 11000 volt grade Armoured Heavy duty UG Aluminium Conductor Cable of Nominal Cross-Sectional Area 95 Sqmm to 120 Sqmm 3 Core including Jointing Kit, Jointing Materials and accessories complete all as specified and as directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 1 KVAR to 30 KVAR to meet the requirement for power factor complete all as specified and as directed by Engineer-in-charge.
Supply & Fix aluminium lugs for cable size 70 Sqm to 120 Sqmm complete all as specified and as directed by Engineer-in-charge.
Supply fuse wire suitable for 33/11 KV yard/ four pole structure complete all as specified and as directed by Engineer-in-charge.
M/S JAGDAMBA ENTERPRISES
SNEH CORPORATION
M/s Yash Electrical and Maintenance
Shri Electrical Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .