Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr Quoted ₹1.4 Cr | L1 | Accepted-AOC Lowest accept |
| 2 | L2₹1.5 Cr+₹6.7 L (4.77%)Rejected-Finance | ₹1.5 Cr+₹6.7 L (4.77%) | L2 | Rejected-Finance 2 nd lowest |
Tender Value
₹1.3 Cr
EMD Value
₹50,000
Closing Date
19 Jan 2024, 3:00 pmClosed
Superintending Engineer
Superintending Engineer,KWA, P H Circle,Thrissur
Supply, installation, testing and commissioning of Floating intake structure and motor Pump set at Peechi reservoir for pumping to 36MLD WTP at Peechi- Pipeline work.
2024_KWA_641471_1
288/SE/PHC/TSR/2023-24
Open Tender
Civil Works - Water Works
Item Rate
180 days
Peechi
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,900
₹50,000
4 Mar 2024
8 Jan 2024
20 Jan 2024
8 Jan 2024
19 Jan 2024
8 Jan 2024
Amount
Floating Intake Structure at Peechi
OD98966/2023-2024:Supply and erecting Submerged Cetrifugal Pumpset, Horizontal Portable, Water Immersed, Dry Air filled, Class "F" insulated, induction motor, Vacuum pressure impregnation treatment, TEWC Motor Integrally mounted for handling Raw Water application for 3 phase, 50 Hz +/- 3%, 415V along with set of 10 m suitable size copper EPR flexible round cables and EPR Copper control cable, Strainer & installation device having material of construction: Casing - Cast Iron,Impeller- CF8M, Wearing Rings - S.S.-CF8M as per the detailed Specifications to draw Raw Water having Discharge Capacity (Q)832.2m3/hr @ 45m Head (H) @ 50 Hz each, (Syn.)-3 W +1 S. Supply of 0-10 kg / cm2 - 100 mm dia, Glycerin Filled Type Pressure Gauge with siphon & cock as per IS specifications with SS ball valve, SS hex nipple, with required accessories, erection hardware, necessary mounting supports, etc. complete and as per the direction of engineer incharge (on each Pump delivery pipe & on header pipe line). Earthing of Electrical equipments confirming to IS 3043. Supply of MCC Panel suitable for above pump set with required 1 No Incomer MCCB with metering & protections , 2 sets of Out going with MCCB + All other equipments as per IS with all required metering and protections, 2 sets MCCB + Capacitor for maintaining the Power factor above 0.95, 2 sets of 63 A MCCB for Misc Supply and installing suitable size soft Starter for above motor as per relevant IS .The item supplied should confirm the type test certificate issued from CPRI Bangalore etc complete. Erection of all equipment's equipments. Supply of 500 mm diameter sizes PN-1.0, Double Flanged Dual Plate Check Valve (DPCV) conforming to API - 594 having body, door, cover in graded Cast Steel ASTM A216 Grade WCB, Metal Seat, Hing/ stop pin, Spring - S.S. AISI 410, Resilent seal - Nitride. Valve seat tested to 10 kg/cm2 and body to 24 kg/cm2. Flanges machined faced and drilled to IS : 1538 / 1976 Part-IV/VI. Hydraulic tests certificate & certificate of material of construction of parts shall be submitted before despatch of valves as per design with required accessories, hardware, bolts, nuts, washers, rubber paking, necessary mounting supports etc. complete. Supply of 500 mm dia., PN-1.0, Double Flanged Manual operated Butter fly valve generally conforming to IS :13905 having body, disc, in graded cast iron to IS:210, FG : 260, shaft, thurst pad of stainless steel AISI 410, body seat ring, internal hardware of SS AISI 304. Valve seat tested to 16 kg/ cm2 and body to 24 kg / cm2 flanges machined faced and drilled to IS : 1538 / 1976 Part-IV/VI. Hydraulic tests certificate & certificate of material of construction of parts shall be submitted before despatch of valves as per design with required accessories, erection hardware, necessary mounting support, etc. SITC 100 mm dia., PN-1.0, Flanged End High Performance Tamper Proof Kinetic Air Valve with Automatic Air Release Valve with Isolating PN 1.6 Sluice Valve, for water combination type (non temporing type) having double ball, double orifice with stainless steel ball, tamper proof air vents rolling seal mechanism for air release and anti vacuum application designed for 16 kg/cm2 working pressure and tested for 24 kg/cm2 pressure, having flat faced flanges and drilled to IS : 1538 / Part-IV /VI. Hydraulic tests certificate & certificate of material of construction of parts shall be submitted before despatch of valves. (Rate to include cost of gaskets, bolts, nut and any other materials required for jointing and its transportation etc. including all taxes and duties. with required accessories, erection hardware, necessary mounting supports etc. (on Header Line)
OD98967/2023-2024:Design,manufacture,transport to site, erect and test one pontoon made of HDPE heavy duty cubes to accomdate 1 No of Submersible Pump set with suitable with required. M. S. frame structure, platform with Aluminum chequered plate, hoisting posts, holding chains and cross beam, pulley block, pump set holding frame, Screen facility to prevent foreign materials from infiltrating the pump suction bell, fixing bolts, MS pipe powder coated hand rails ,epoxy painted,PVC/ HDPE Heavy Duty Drums/ of suitable capacity to withstand the thrust imposed by the dead and live loads and having sufficient working space along with tools and tackles .
OD98968/2023-2024:Design, manufacture, transport to site, erection, testing and commissioning of, walk way cum pipe carrying plat form 1.5 mtrs wide and made of HDPE cubes and mettalic platforms cum provision for walkway with chequered aluminium sheets and cable supports provided with powder coated hand rails, brackets for fixing pipe, hinges etc.- Running Mtrs.
OD99248/2023-2024:Supply and delivery at site - 250mm SS pipe PN 1 AISI 304 annular corrugated metallic flexible hose pipe with AISI 304 double wire braiding with both end flanes. ( Each pipe having a length of 2m D/F ) including cost of flanges etc.
OD99249/2023-2024:Supply and delivery at site - 250mm SS pipe PN 1 AISI 304 annular corrugated metallic flexible hose pipe with AISI304 double wire braiding with both end flanges. ( Each pipe having a length of 3m D/F ) including cost of flanges etc.
OD98969/2023-2024:Supply Fabricated MS Specials like (i) D/F Tapper/ Enlargers (ii) 90 Deg. D/F Bends (iii) D/F Distance Pieces (DPCV & BFV) (iv) Double flanged M.S.Pipes pieces for Air Valves (v) 90 Deg. Bends ,(vi) Blind Flanges/Blank plates (vii) Std. Drilled Flanges for pumpset delivery (viii) Std. Drilled Flanges for Header line including bolts, nuts, washers, rubber packings etc, suitable for above pumpsets and common header. Dimensions and Drilling of flanges should be as per IS;1538/1976. Flange faces should be machined and holes should be drilled on drilling machine. M.S pipe should be conforming to IS-3589/ 2001 and for 113.10 mm dia. IS-1239 Part-1/ 2004. All specials & pipes should be painted by epoxy paint.
18.30.6:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:250 mm diameter pipe
18.30.11:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:500 mm diameter pipe
OD100038/2023-2024:Supplying at site 3.5 Core x 240 sq. mm size 1100 V rated, XLPE insulated, Aluminium conductor and steel strip armoured LT power cables as per IS 7098 / Part I 1988 with latest amendments, (Red, Yellow, Blue for phase and Black for neutral) with following specifications : Type - XLPE (Cable code A2XFY), Voltage grade 1000 V, size 3.5 C x 240 sq mm, Conductor - Stranded Aluminium wires conforming to IS 8130 with latest amendments, Insulation - Cross Linked Polyethylene, Inner sheath - Insulating material of vulcanized rubber or Thermoplastic materials, Armour - Flat steel strip, Over sheath - Overall extruded PVC as per IS 5831-1984 with latest amendments, Standards - The cable shall confirm to IS 7098 / Part I 1988 with latest amendments
OD100050/2023-2024:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Above 185 sq. mm and upto 400 sq. mm
OD100049/2023-2024:Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm
OD100054/2023-2024:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 185 sq. mm and upto 400 sq. mm DSR(E&M) 2018 7.8.4
OD219144/2023-2024:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 240Sqmm
OD100055/2023-2024:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm
100.98.437:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Kinetic Air Valve Type DK, Size 100mm.
100.32.5:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 100mm Double Acting Air Valve.
OD100691/2023-2024:Supply at site 1.5 sqmm 24 core PVC / XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE
OD98981/2023-2024:Supply at site 2.5 sqmm 10 core PVC/ XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE
OD219301/2023-2024:Supplying at site 95 sqmm 3.5 core PVC /XLPE insulated armoured cable with copper conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/ 1988 for PVC IS 7098 part I for XLPE
OD219554/2023-2024:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
OD98973/2023-2024:Supply,Installation,Testing and Commissioning of Junction box on the shore with Connection strips, terminal plates, angular frame and necessary fixing materials and provision for receiving power & control cable from starter and motor including push buttons, RYB lamps, Voltmetre, Ammeter, stop button with key
OD98974/2023-2024:Supply Installation testing commissioning of of Junction box on the pontoon with Connection strips, terminal plates, angular frame and necessary fixing materials and provision for receiving power & control cable from starter and motor
OD98976/2023-2024:Supply,Installation,Testing and Commissioning of necessary earthing system at junction box on shore and in floating unit
OD219650/2023-2024:Supply & laying the following sizes of Earth Strip for earthing interconnection, termination and leads, for continous earthing along with cables tinned at terminals etc. complete. 25 x 6 mm Copper Strip
OD98977/2023-2024:Supply,Installation,Testing and Commissioning of electrically operated winteches to anchor the floating system with necessary steel rope and electrical control system to anchor floating pontoon towards header side
OD98978/2023-2024:Supply of necessary, steel ropes, concrete blocks for using as counter weight etc. as required for stabilizing the pontoons and walk way including steel ropes for sideways anchoring of pontoon
OD98979/2023-2024:Supply Installing Testing and Commissioning of PN 1 double door type check valve 500mm
OD98980/2023-2024:Supply InstallationTesting Commissioning of PN 1 Butterfly valve on delivery side 500mm
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
OD199588/2023-2024:Conveying and laying SS Flexible corrugated hose pipe of 250mm diameter. Excluding cost of pipe and specials
Providing light and power point arrangements
OD98984/2023-2024:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required
OD98985/2023-2024:Wiring to the 5 Amps plug points with 3/22 PVC insulated copper conductor along with single run 3/22 PVC insulated copper conductor (Green colour) drawn inside suitable size PVC conduit pipe with necessary bends, elbows, junction boxes etc. in open conduit system clamped on struss/wall with suitable clamps and saddle clips including supplying and fixing of 5 Amps flush type 3 pin plug control switches fixed in combined position on suitable box per point
OD98986/2023-2024:Supplying and fixing LED tube light fitting (Twin tube - 24W) with lamp holder, 2 Nos. 24W tube of 1200 mm long fittings directly on the wall/ceiling.
OD98987/2023-2024:Supplying and fixing of 100W LED street light fitting with all accessories etc. complete as per standards.
OD98988/2023-2024:Supplying, fixing of the 10 A SP MCBs in a suitable size MS enclosure for controlling street lights
OD98989/2023-2024:Supplying and fixing of 1200 mm sweep AC ceiling fan with standard down rod and electronic type regulator.
OD98990/2023-2024:Supplying and fixing of 12” dia single phase heavy-duty 1500 RPM exhaust fan with necessary MS frame work.
OD98991/2023-2024:- Supply, laying, and termination of 3 core 2.5Sqmm PVC/XLPE insulated, sheathed armoured copper conductor cable (1100 volts grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench etc. complete as per standards.
Extension of pump control Panel Room
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
50.6.1.6:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
OD99014/2023-2024:Dismantling and fixing in new position existing rolling shutters of pump house including all charges cost of materials, hire charges of tools, labor etc as per direction of Department officers etc complete.
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.3:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness
10.25.1:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete
Truss Work - Header block panel area
10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
12.4.2:Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m2
12.7.2:Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.63 mm thick with zinc coating not less than 275 gm/ m2
12.41.1:Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.75 mm diameter
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
SAJU JOHN N
Bidder Name
SAJU JOHN N
TONY P THEKKINIYATH
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_978840.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .