Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.1 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED | |
| 2 | L2₹45.8 L+₹25,404.19 (0.56%)Rejected-AOC | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 3 | L3₹46.9 L+₹1.4 L (3.05%)Rejected-AOC NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 4 | L4₹52.8 L+₹7.3 L (16.1%)Rejected-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L4 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
10 Jun 2025, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE ARMY GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR REPLACEMENT AND IMPROVEMENT IN MAINTAINENCE OF WATER SUPPLY PUMPING SYSTEM AND SECURITY LIGHT IN OTM AND MD ACCN AT GANDHINAGAR MIL STATION
2025_MES_708103_1
GE(A)/GNR/TOKEN/07 of 2025-26
Open Tender
Civil Works - Water Works
Item Rate
180 days
GANDHINAGAR MIL STATION
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹97,000
Yes
11 Jul 2025
14 May 2025
17 Jun 2025
14 May 2025
10 Jun 2025
28 May 2025
14 May 2025 - 26 May 2025
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cable etc including getting out soft/loose soil complete all as specified.
Excavation in trenches (Earth work in excavation) by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-incharge
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type soil.
Removing of surplus soil not exceeding 50mtrs and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed by Engineer-in-Charge
Taking up 300 mm bore, cast iron water mains (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed.
Taking up,250 mm bore, cast iron water mains (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed.
Taking up 200 mm bore, cast iron water mains (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed.
Taking up,150 mm bore, cast iron water mains (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed.
Supply, laying, connecting, jointing and testing of DI pipe with spigot and socket ends, class K-7 conforming to IS: 8329/2000 suitable for (push-on) rubber gasket jointing with centrifugally applied inside cement mortar lining with sulpher resistant with a finishing layer of black bitumen coating on external surfaces in any length, laid in trenches as per IS 12288 (1987) complete all as specified and as directed of the following sizes :
300 mm Bore
250 mm Bore
200 mm Bore
150 mm Bore
Note:- For item 9, 9.01, 9.02, 9.03, 9.04 pipe will layed in full piece, halflength, short piece to rectify any kind of leakage as per site requirement and rate shall deemed to be incl in quoted rate.
S&F, in repair, Ductile iron resilient seated gate valve 300 mm dia with flanged ends class PN-1.6, Hand wheel operated, Non rising stainless steel stem, EPDM seat, EPDM bonnet gasket, EPDM Housing bush O ring, and EPDM sealing Ring flanges drilled to IS:1538, Shell test pressure-2.4 MPa (Hyd), Seat test pressure-1.6 MPa, confirming to IS :14846 including all jointing materials such as nuts, bolts, washers and gaskets etc. complete all as specified & directed by Engr-in-charge.
S&F, in repair, Ductile iron resilient seated gate valve 250 mm dia with flanged ends class PN-1.6, Hand wheel operated, Non rising stainless steel stem, EPDM seat, EPDM bonnet gasket, EPDM Housing bush O ring, and EPDM sealing Ring flanges drilled to IS:1538, Shell test pressure-2.4 MPa (Hyd), Seat test pressure-1.6 MPa, confirming to IS :14846 including all jointing materials such as nuts, bolts, washers and gaskets etc. complete all as specified & directed by Engr-in-charge.
S&F, in repair, Ductile iron resilient seated gate valve 200 mm dia with flanged ends class PN-1.6, Hand wheel operated, Non rising stainless steel stem, EPDM seat, EPDM bonnet gasket, EPDM Housing bush O ring, and EPDM sealing Ring flanges drilled to IS:1538, Shell test pressure-2.4 MPa (Hyd), Seat test pressure-1.6 MPa, confirming to IS :14846 including all jointing materials such as nuts, bolts, washers and gaskets etc. complete all as specified & directed by Engr-in-charge.
S&F, in repair, Ductile iron resilient seated gate valve 150 mm dia with flanged ends class PN-1.6, Hand wheel operated, Non rising stainless steel stem, EPDM seat, EPDM bonnet gasket, EPDM Housing bush O ring, and EPDM sealing Ring flanges drilled to IS:1538, Shell test pressure-2.4 MPa (Hyd), Seat test pressure-1.6 MPa, confirming to IS :14846 including all jointing materials such as nuts, bolts, washers and gaskets etc. complete all as specified & directed by Engr-in-charge.
S&F, in repair, DI fittings conforming to IS 9523 (2000), bends, tapers any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of size for 80 to 350 mm bore complete all as specified and directed by Engr-in-charge.
M&L for horizontal drilling, in any type of soil, using trenchless technology suitable for insertion of CI/GI/DI pipe complete all as specified and directed of following sizes.
250 mm size bore for 150 mm pipe
300 mm size bore for 200 mm pipe
350 mm size bore for 250 mm pipe
400 mm size bore for 300 mm pipe
M&L for run lead joint for 200mm bore spigot & socket CI pipes and fittings complete all as specified and directed.
M&L for run lead joint for 300mm bore spigot & socket CI pipes and fittings complete all as specified and directed.
M&L for Cleaning of underground RCC reserviour(sump) 2,00,000 gallon (inner compartment capacity 1,60,000 gallons, outer compartment capacity 40,000 gallons) at main pump house, by draining out stored water completely with mud, pumping out and throwing away manually with buckets and cleaning of inner surface of bottom and walls of sump after removing complete accumulated sludge/mud, dirt etc and scraping all inner surfaces with steel wire brush and finally washing with fresh water two times, disinfecting the reserviour with 2% solution of potassium permanganate, two coat of white wash inside of the sump and two coat of snowcem paint to the out side of the sump including writing date of cleaning with white synthetic enamel paint complete all as specified and directed.
M&L for Cleaning of underground RCC reserviour(sump) 25000 gallon at MAP pump house, by draining out stored water completely with mud, pumping out and throwing away manually with buckets and cleaning of inner surface of bottom and walls of sump after removing complete accumulated sludge/mud, dirt etc and scraping all inner surfaces with steel wire brush and finally washing with fresh water two times, disinfecting the reserviour with 2% solution of potassium permanganate, two coat of white wash inside of the sump and two coat of snowcem paint to the out side of the sump including writing date of cleaning with white synthetic enamel paint complete all as specified and directed.
Dismantling existing pipe connections and electrical connections and lifting up the submersible pump and motor with submersible cable to ascertain the fault occured in PH of borewell open type/In house type with depth not less than 200M of cap 60 HP type , 3 phase 415 volts 50 HZ carefully and transporting to workshop for repair and bringing back at site after repair and lowering the same including making the water and electric connection including commissioning and testing complete. Note :- (i) Repair of submersible pump and pump motor shall be measured & paid separately under respective item of this schedule. (ii) T&P shall be arranged by the contractor. (iii) Transportation of pump set from site to workshop and bringing back at site inclusive in quoted rate.
Dismantling existing pipe connections and electrical connections and lifting up the submersible pump and motor with submersible cable to ascertain the fault occured in PH of borewell open type with depth not more than 15M of cap 25 HP type , 3 phase 415 volts 50 HZ carefully and transporting to workshop for repair and bringing back at site after repair and lowering the same including making the water and electric connection including commissioning and testing complete. Note :- (i) Repair of submersible pump and pump motor shall be measured & paid separately under respective item of this schedule. (ii) T&P shall be arranged by the contractor. (iii) Transportation of pump set from site to workshop and bringing back at site inclusive in quoted rate.
De-assembling of electric motor of 45 KWs/60HP of submersible pump set cutting and removing the existing burnt winding wire of any gauge, cleaning and making good the slots, rewinding the electric motor with PVC insulated copper wire of appropriate size/gauge, application of insulating material & varnishing including replacing of ball bearings-02 Nos, moisture seal and re-assembling the motor, commissioning & testing complete to the entire satisfaction of Engineer-in-charge all as specified and directed.
De-assembling of submersible pump assembly of cap 60 HP Make-KSB, for repair by replacing of company recomended parts of Mechanical seal - 2 Nos, CI impeller - 1 No, Lower Bearing - 1 No, O Ring - 1 No, Spiral plate - 1 No, Compay recomended Lubriucating oil - 7 Ltrs, Moisture sensor including bolts, nuts and washers, re-assembling the same and comisioning & testing complete all as specified and directed.
De-assembling of electric motor of 10-20 KWs of submersible pump set (Make KSB), cutting and removing the existing burnt winding wire of any gauge, cleaning and making good the slots, rewinding the electric motor with PVC insulated copper wire of appropriate size/gauge, application of insulating material & varnishing including replacing of ball bearings-02 Nos, moisture seal and re-assembling the motor, commissioning & testing complete to the entire satisfaction of Engineer-in-charge all as specified and directed.
De-assembling of submersible pump assembly of cap 25 HP Make-KSB, for repair by replacing of company recomended parts of Mechanical seal - 2 Nos, CI impeller - 1 No, Lower Bearing - 1 No, O Ring - 1 No, Spiral plate - 1 No, Company recomended Lubriucating oil - 7 Ltrs, Moisture sensor including bolts, nuts and washers, re-assembling the same and comisioning & testing complete all as specified and directed.
Disconnecting electrical connection from panel and detachment from Pump and Mot Base Frame and existing pipes for carrying out repairs and rewinding to 30 HP capacity mono block pump set, motor, 3 phase 415 Volt of any make Kirloskar, Jyoti, Crompton Greaves / Mother platt) with super enameled copper winding wire of appropriate gauge, insulation and varnishing with 'E' class varnish including replacement of water seal, dismantling existing motor from foundation after disconnecting electric connection transporting the same at work shop for repair and back at site after repair, reassembling with pump, commissioning and testing etc complete all as specified and directed by Engineer-in-charge.
M and L for cleaning of RCC OH tank of Cap 2 LG complete by adding 1 kg of bleaching powder in 10 Litres of water and pumping into the tank, leaving the mixture for 30 min and draining out all the dust and solid matter residue from drain pipe of inner and outer tank by pumping the water into the inner and outer tank for sufficient time complete all as directed by Engr-in-charge. Note:- the access ladder of OH tank is not in service and OH tank is not approachable
M and L for cleaning of RCC OH tank of Cap 1 LG complete by adding 1 kg of bleaching powder in 10 Litres of water and pumping into the tank, leaving the mixture for 30 min and draining out all the dust and solid matter residue from drain pipe of inner and outer tank by pumping the water into the inner and outer tank for sufficient time complete all as directed by Engr-in-charge. Note:- the access ladder of OH tank is not in service and OH tank is not approachable
Demolition of existing valve pit and M&L for construction of valve pit consisisting of 230mm thick, old size brick masonry wall in cement mortar (1:6), PCC (1:4:8) type D2, using 40mm graded stone aggregete as in fondation, PCC (1:2:4) type B1, using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash and earth work in any type of soil and including 2 mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc. as specified and directed for the size 1350mm x 1000mm x 1200mm
Supply, install, testting and commisioning of LT MCC panel box company fabricated, outdoor type made out of MS CRCA sheet 3.0mm thick with angle iron frame 50x50x6mm floor mounted support suitable for 3 phase 4 wire 50 HZ, 1100 V system weather and vermin proof double door including front and back opening, all internal connections incoming to outgoing with copper BUS BAR, chromium plated brass cable glands painting with a coat of redoxide primer and powder coated paint of approved colour and make complete with structure, insulators, nuts and bolts, washers etc includng PCC for fixing and consisting of the following :- INCOMING (a) Changeover switch of cap 250 A (b) MCCB incoming , 250 Amps, 4 pole, 415 volts (for incoming) 36 kA breaking capacity-01 No (c) Bus bar with aluminium strip of 40 mm x 10 mm for 3 phase and neutral system with CTs - 01 Set (d) Digital multi function meter for volt, Amp, KWH, PF and other parameter OUTGOING (a) outgoing fully automatic star delta 3 phase starter 24 kw-03 Nos incl push buttton for start/stop (b) outgoing fully automatic star delta 3 phase starter 40kw-01 incl push buttton for start/stop (c) Outgoing MCCB 160 A, 4 pole, 415 V, 26 kA Breaking Capacity-02 Nos (d) MCB SPN 32 Amps, 415 Volts (for outgoing) 10 KA - 01 No (e) Internal control wiring with suitable size and rating of wire
Supply, install, testting and commisioning of LT panel box company fabricated, outdoor type made out of MS CRCA sheet 3.0mm thick with angle iron frame 50x50x6mm floor mounted support suitable for 3 phase 4 wire 50 HZ, 1100 V system weather and vermin proof double door including front and back opening, all internal connections incoming to outgoing with aluminium BUS BAR, chromium plated brass cable glands painting with a coat of redoxide primer and powder coated paint of approved colour and make complete with structure, insulators, nuts and bolts, washers etc includng PCC for fixing and consisting of the following :- INCOMING (a) Changeover switch of cap 250 A (b) MCCB incoming , 250 Amps, 4 pole, 415 volts (for incoming) 36 kA breaking capacity-01 No (c) Bus bar with aluminium strip of 40 mm x 10 mm for 3 phase and neutral system with CTs - 01 Set (d) Digital multi function meter for volt, Amp, KWH, PF and other parameter OUTGOING (a) Outgoing MCCB 160 A, 415 V, 26 kA Breaking Capacity-01 Nos (b) MCB SPN 32 Amps, 415 Volts (for outgoing) 10 KA - 02 No (c) DigitalTimer switch for street light operation with 40 A contactor, AC-3 with 220 V AC (d) Internal control wiring with suitable size and rating of wire
M and L along with Spl T & P for Shifting of existing LT MCC panel complete incl making all cable terminations with glands, lugs etc as well as making the PCC plafform to the site complete all as specified and directed by Engr-in-charge
Supply, laying and testing cable XLPE Insulated galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core x 70 Sqmm.
Supply, laying and testing cable XLPE Insulated galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core x 50 Sqmm.
M and L for taking water sample from borewell No 1, 2,3,4, Narmada Filteration plant and STP plant Qtrly for supply Water Test and submission of water test report complete all as specified and directed by Engr-in-charge. Note :- (i) The Sample of water to be taken in a clean closed container of glass bottle as recommended from the lab to be provided by the contractor. (ii) The water test report must be obtained from an FSSAI recognised /NABL accredicted Lab.
M/L providing cement concrete type B1 (1:2:4) using 20mm graded stone aggregate as in roof kerbs or mud stops, base for valve pit, making good the road cutting and like, rounded or chamfered on edges all as specified and directed by Engr-in-charge.
M & L rendering 15 mm thick plaster in CM 1:6 on brick work or concrete surface, finished even & smooth without using extra cement all as specified and directed by Engr-in-charge.
M and L for breakdown maintainence of 300mm MS/CI pipes between GTPH to GE (A) Gandhinagar by providing Special T and P (JCB, Hydra, Crane) and taking shutdown from GWS&SB to ensure the work carried out in online/offline with coordination of contractor to GWS&SB and as directed by Engr-in-charge.
M and L for repair of leakage in MS pipe with special T and P ( e.g JCB, Crane, Welding Machine) of Size 300 mm inner dia by using Heavy duty MS pipe line Clamps alongwith nut bolts and necessary accessories complete all as specified and directed by Engr-in-charge.
M and L for repair of leakage withwith special T and P ( e.g JCB, Crane, Welding Machine) for Online pipe leak repair joints with rubber gaskets, adhesive, nut bolts of adequate size of CI/DI pipe with dia not less than 250/200mm complete all as specified and directed by Engr-in-charge.
Repair to existing damaged valve chamber of any size by PCC work using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash including 2 mm thick MS sheet cover suitable with exsiting chamber fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc. as specified and directed by Engr-in-Charge.
Dismantling/taking Out path/Interlocking tiles/ chequered tiles from the site safely laid bedded and pointed in any mortar, kept in custody and relaying the same after execution of work at existing site incl PCC work complete all as speciifed and directed by Engr-in-charge.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to using galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by ENgr-in-charge
Supply and Fix extended stem of sluice valve for not less than 2 m of any type and size complete all as specified and directed by Engr-in-charge.
Hiring of Special T&P such forklift, Hydra crane, JCB for lifting of Hevay duty pipes/Pumps/motor/Panels from the site complete all as specified and directed by Engr-in-charge.
Note for item 1 to 45, for any damage to MES property (Path, walls, Road, UG cable, UG pipes etc) done by the contractor while execution of work shall be repaired by the contrcator within 2 Hrs of breakdown if it pertains to E/m Ext Elec, Ext water Supply to avoid hampering of services in Stn without claiming any extra cost from the Department.
Material and labour for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Complete all as specified and as directed. Note: Depth after punning shall be measured and paid.
Supply and laying sub class 'B' burnt bricks, minimum size of brick 228 mm x 90mm x 65 mm, laid as cable protection cover complete all as specified and as directed.
Supplying & laying, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium conductor, 1100 volt grade, of size 6 Sqmm 2 core, laid in trenches/ duct, passing through pipe/ duct or fixed on pole and connecting and testing complete all as specified and as directed by Engr-in-charge. Make:- Seewel, CCI, Asian
S&F, PVC insulated and PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, passing throuth pipe, on pole/wall from juntion box to street light fitting complete all as specified and directed by Engr-in-charge. Make:- Seewel, CCI, Asian
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP66 protection complete including taking out old unserviceable fitting of any type complete all as specified and as directed.
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including taking out old unserviceable fitting of any type complete all as specified and as directed.
Supply and fix in repair LED Flood light 100 watt 230 volt AC outdoor type with thermal management in multiple optics and equipped with IP 66 proection with impect and corrosion resistant complete all as specified and as directed.
Supply and fix in repair LED Flood light 120 watt 230 volt AC outdoor type with thermal management in multiple optics and equipped with IP 66 proection with impect and corrosion resistant complete all as specified and as directed.
Supply and fix in repair LED post top Lantern 30 W, 230 volt AC outdoor type withdie cast aluminium powder coated top cover and clear acrylic diffuser equipped with IP 65 protection with corrosion resistant complete all as specified and as directed.
Supply and fix in repair cylindrical shaped cast aluminium LED bollard light 10W, 900mm size with opaque threaded polycarbonate diffuser for optimum ingress protection, in built driver, 230 volt AC outdoor type equipped with IP 65 protection with corrosion resistant complete all as specified and as directed.
M&L for scratching out old bubbled paint, finishing the surface with one coat of primer (red oxide) & two coats of aluminium paint of 1st quality to street light steel tubuler poles of any height 7/9 mtr , any type (double swan, single swan) all as per site including two strips of 30 cm wide to be painted red synthetic enamele above embedded level, including pole number writting with white colour enamel paint on black colour circular base) with two coat of lime wash on pole coping all as directed by Engr-in-charge.
M&L for repair of street light timer switching system, by replacement of following incl fixing to panels, setting of time of operation for street lights complete all as specified and as directed by Engr-in-Charge.
Digital time switch, Electro mechnical type with programming using captive segments with 24 hrs timing setting, AC 230 V Make: Alpharex D21 Legrand or equivalent L&T, Schenider
AC contactor, (relay), 3 Pole, 230 V, 40 Amps complete with electrical internal connection Make: DX3 in legrand or equivalent in L&T, Schenider
S&F in repair MS made junction box of CRCA sheet min thickness 1.6 mm, outdoor type, size 250 x 200x 150 mm factory made,, with one No SP MCB of 6 Amp rating, class-B and terminal assembly with min 4 terminals necessary clamps and bolts etc of MS iron including connecting with street light cable complete all as specified and directed by Engr-in-charge.
Taking down high mast LED light fitting of 18 Mtr hight and repair to existing motor with replacement steel rope etc and refixing the same including electrical connection and testing complete all as directed by Engr-in-charge.
Supply and replacement of High mast panel front/back door with existing thickness MS sheet not less than 1.5 mm powder coating paint including locking arrangement , Panel internal wiring and one coat existing paint complete all as per directed by Engr-in-charge
M and L for servicing , maintainence and repair/replacement of street/ security light fixed on pole by cleaning of all parts such as driver, control gears, reflectors, diffusers etc complete all as per directed by Engr-in-charge for the street light of follwing capacity:-
LED street light of 25 W
LED street light of 35 W
LED street light of45 W
LED street light of 60-70 W
M and L for servicing , maintainence and repair/replacement of LED flood light fixed on high mast pole by cleaning of all parts such as driver, control gears, reflectors, diffusers etc complete all as per directed by Engr-in-charge for the street light of follwing capacity:-
LED Flood light of 90-100 W
LED Floodt light of 120-150 W
M and L for servicing , maintainence and repair/replacement of LED Gate light/Post top Lantern of any capacity and any size by cleaning of all parts such as driver, control gears, reflectors, diffusers etc complete all as per directed by Engr-in-charge
M and L for servicing , maintainence and repair/replacement of LED bollard light of any capacity and any size by cleaning of all parts such as driver, control gears, reflectors, diffusers etc complete all as per directed by Engr-in-charge
NOTE for item No 61 to 64 : Replacement of UNSV parts shall be measured and paid seperately under mentioned items.
M and L for soldering of terminals inside the LED street light of any capacity and size complete all as specified and directed by Engr-in-charge.
M and L for replacement of LED strip by soldering of LED of 1-10 W having each strip of 1 to 20 LED complete all as specified and directed by Engr-in-charge.
M and L for repair/replacement of diode/resistor/defective parts of surge protection system of LED street light of any size and capacity complete all as speciifed and directed by Engr-in-charge.
M and L for replacement of compatible drivers as per existing by proper termination for LED street light of follwing capacities complete all as specified and directed by engr-in-charge.
Driver for LED of cap 5 W
Driver for LED of cap 8-24W
Driver for LED of cap 25-35 W
Driver for LED of cap 60-80 W
Driver for LED of cap 90-100W
Driver for LED of cap 120-150 W
M and L for replacement of compatible diffuser as per existing for LED street light of follwing capacities complete all as specified and directed by engr-in-charge.
Diffuser for LED of cap 10 W
Diffuser for LED of cap 15 W
Diffuser for LED of cap 35 W
Diffuser for LED of cap 60 W
Diffuser for LED of cap 70 W
Diffuser for LED of cap 100 W
M and L for replacement of compatible rubber gasket as per existing for LED street light of follwing capacities complete all as specified and directed by engr-in-charge.
Rubber Gasket for LED street light of cap 10 W
Rubber Gasket for LED street light of cap 15 W
Rubber Gasket for LED street light of cap 35 W
Rubber Gasket for LED street light of cap 60 W
Rubber Gasket for LED street light of cap 70 W
Rubber Gasket for LED street light of cap 100 W
M and L for replacement of compatible base plate as per existing for LED street light of follwing capacities complete all as specified and directed by engr-in-charge.
Base Plate for LED street light of cap 35 W
Base Plate for LED street light of cap 60 W
Base Plate for LED street light of cap 70 W
Base Plate for LED street light of cap 100 W
M and L for repair of terminals of junction box by replacement of 4 way terminal block complete all as specified by Engr-in-charge.
M and L for locking arrangement of LED street light/flood light fitting of any capacity/size complete all as specified and directed by Engr-in-charge.
M and L for repair of bracket by welding of new additional pipe of dia 20 mm-25mm upto 0.3 m in order to make it compatible with existing LED street light fitting for mounting incl repair to bracket clamp by suitable nut bolts, clamps etc complete all as specified and directed by Engr-in-charge.
M and L for painting of PCC pole by one coat of cement based paint and two coat of Birla white weather paint/waether coat complete all as specified and directed by Engr-in-charge
M and L for paintiing of PCC poles by synthetic enamel paint as such Zebra painting of alternate height of yellow and black for 300 mm of each colour upto 3 levels of each colour per PCC poles complete all as specified and directed by Engr-in-charge.
M and L for paintiing of steel tubular poles by synthetic enamel paint as such Zebra painting of alternate height of yellow and black for 300 mm of each colour upto 3 levels of each colour per steel tubular poles complete all as specified and directed by Engr-in-charge.
Supply and Fix in repair tricolour LED flexible rope light, IP 65 protection, rust resistant, water resistant, with surge protection 3.5 kV, 120 LED per meter, 6 Mtr Length, Wide Operating Voltage Range (140V-300V), life of minimum 15000 Hrs complete all as specified and directed by Engr-in-charge.
Taking out carefully from existing grouted position PCC/steel tubular poles by using special T&P (Crane, JCB, Hydra) from the site by removing all the cradles, cross arm, complete incl all as specified and directed by Engr-in-charge. Note:- Taken out poles should be transported out of the mil stn Gnr to the charge of the contractor rate of which shall deemed to be incl in quoted rate
Labour and special T &P for erection and grouting of Steel tubular swaged poles complete with MS base plate, finial taper plug, bolts, nuts & screws as specified (8.5 metres long) complete all as specified and directed by Engr-in-charge.
M&L for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundtion of PCC poles/struts all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed.
DIGNATION ENTERPRISE (BID ID -3318723)
BK CONSTRUCTION (BID ID -3307771)
Abhishek Enterprises (BID ID -3318452)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .