Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹83.7 Cr
EMD Value
₹83.7 L
Closing Date
16 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, P. H. Works Division, Tharad
Working survey, Soil Investigation, Design, Build and Operate(with Trial Run of 3 Months) Contract for Providing, Supplying, Lowering, Laying and Jointing Rising Main, Gravity Main and Distribution Pipeline, Supply, Installation, Testing and Commissioning of Pump With Associated Mechanical and Electrical Equipments, Instruments and Accessories, Clear water sump, Elevated Service Reservoir, Staff Quarters, Pump House, Compound Wall, Approach Road (RCC) at various HW SHW village with Operation and Maintenance of All type of Civil Structures, Mechanical Equipment and Pipeline Network for 10 years for 71 villages under BK 4 Ph 2B and 3A Regional Water Supply Scheme(Old and New component) based on NMC (East Zone) District Vav-Tharad
265213
17/2025-26
Open
Civil Works - Water Works
Works
Banaskantha
16 documents required · 16 mandatory
₹30,000
Executive Engineer, P.H. Works Division, Tharad
₹83.7 L
17 Jan 2026
17 Jan 2026
17 Jan 2026
16 Feb 2026
17 Jan 2026
Providing and supplying in standard length ISI mark unplasticised PVC pipes suitable for potable water with ringfit joint including cost of rings as per IS specificaiton no. 4985/1988 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the departmental stores and including cost of jointing material etc. complete. Grade - 6 kg/cm2 PVC Pipe. (i) 110 mm dia
140mm dia
160mm dia
180mm dia
200mm dia
250mm dia
315mm dia
Providing and supplying D. I. K-7 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). 200 mm dia
250mm dia
300mm dia
400mm dia
Manufacture, Supply and Delivery of Ductile Iron Flange socket spigot bends, tees, reducers or any other specials as per BS-EN-545/1995 Class-A series K12 suitable for use with D.I.Pipes manufactured as per IS:8329/1994delivery of specials is to be made to GWSSB store or site of works any where in Gujarat including all taxes, liading, unloading, carting, stacking, insurance, inspection charges, octroi etc. complete. with external bitumen and zinc coating and internal cement mortar lining.(i) 80 to 300 mm Dia
350 and Above
Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Or Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.(A) Sluice/Scavar valves with ISI mark only. PN 1 with hand wheel/cap operated (PD tpye short body) (i) 100.00 mm
Butterfly valves IS 13095 with ISI mark PN 1.6 100mm
Butterfly valves IS 13095 with ISI mark PN 1.6 150mm
Butterfly valves IS 13095 with ISI mark PN 1.6 200mm
Butterfly valves IS 13095 with ISI mark PN 1.6 250mm
Butterfly valves IS 13095 with ISI mark PN 1.6 300mm
Providing and supplying C. I. Temper proof Air valves with SS 304 Float gun metal- nozzle of approved make and quality of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. With Isolating Sluice valve PN 1.0 (i) 50 mm
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified. Upto 1.50 mt depth (i) In all sorts of soil and soft murrum
In hard murrum, boulders incl. macadam road.
In soft rock
In hard rock and / or in C. C. 1:2:4 or RCC with blasting and chiseling or by chiseling only.
Upto 1.50 to 3.00mt depth (i) In all sorts of soil and soft murrum
In hard murrum, boulders incl. macadam road.
In soft rock
In hard rock and / or in C. C. 1:2:4 or RCC with blasting and chiseling or by chiseling only.
Lowering, laying, fixing and jointing PVC/uPVC/cPVC pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of labour, material, cement solvent, giving satisfactory hydraulic testing as per ISI code.(i) 110
Lowering, laying and jointing C. I. S and S Spun pipes suitable for Tyton joints / Mortarlined D. I. K-7 and K-9 Pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-incharge includi including nut bolts and giving satisfactory hydraulic testing, etc complete.(i) 200
Item Description
Lowering, laying and jointing in position following C. I. / D/F Reflux valves, Butterfly valves, Sluice valves and Air valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete.S.C Valve PN 1.0 with hand wheel/cap operated (PD tpye short body) (i) 100
Butterfly valves IS 13095 with ISI mark PN 1.6 (i) 100 mm
Temper Proof Air valve (i) 50mm
Erection of airvalve riser by installing new MS pipe of 6mm thick and 3.2mt. Length with necessary fittings such as flange of appropriate size, nut, bolts and embedded the pipe in RCC M15 with offset of 10cm around pipe with necessary steel etc. complete (i) 50mm
Refilling the pipeline trenches incl. ramming, watering, consolidating desposal of surplus stuff as directed within a radius of 3 km. Refilling as directed
Construction of valves chambers in brick or bela stone masonary, locally available in C. M. 1:6.Foundation concrete 150 mm thick in C. C. 1:4:8 of trap metal size 25 mm to 40 mm thick, inside cement plaster in C. M. 1:3 and cement pointing outside in C. M. 1:3 and top cover of precast RCC slab 100 mm thick (with key hole in two parts, each with handles or MS Bar etc. complete as given size) Upto 1mt. depth from G.L. to pipe invert level comp. civil works but excl. cost of excavation and refilling.a) Size of 1.30 x 1.30 m and 1.0 m with precast slab in two parts 15 mm
b)Size of Chamber 1.30 m x 0.90 m and 1 mtr deep-with precast slab in two parts 15 mm
c)Size of Chamber 0.90 m x 0.90 m and 1 mtr deep-with precast slab in two parts 15 mm
d)Size of Chamber 0.60 m x 0.60 m and 1 mtr deep-with precast slab in two parts 15 mm
Extra depth of V.C beyond 1.00 mt depth (a) Size of Chamber 1.30 x 1.30 m and 1.0 m deep for (valve greater than 250mm dia)
b)Size of Chamber 1.30 m x 0.90 m and 1 mtr deep 250mm dia
c)Size of Chamber 0.90 m x 0.90 m and 1 mtr deep for (valve equal to 200-250mm dia)
d)Size of Chamber 0.60 m x 0.60 m and 1 mtr deep for (valve less than 200mm dia)
Providing C.C.M.:100 for encasing/CC Block pipes using trap metal size 12 mm to 25 mm incl. form work curing consolidation etc. complete for various location on pipeline
Reinstatement of roads with RCC where pipe crossing the asphalt road / rcc road / industrial area / residental area. the Work including excavation, dressing and making a base for road, 150 mm thick PCC in M10 grade of concrete,and Providing and laying 150 mm thick RCC M20 grade concrete, Providing TMT bars FE-415 reinforcement for RCC work including bending, binding and placing in position complete work including form work, curing etc. completed
Drilling of horizontal borehole for water main pipeline crossing under the road incl. in all starta with required length incl. fixing of MS casing pipe with pushing etc complete various size of pipe for water main. (For 45mtr. Length) (without water main only casing pipe) (i) 200mm dia bore hole with 150mm dia MS casting pipe of 5 mm thick
250mm dia bore hole with 200mm dia MS casting pipe of 5 mm thick
300mm dia bore hole with 250mm dia MS casting pipe of 5 mm thick
500mm dia bore hole with 400mm dia MS casting pipe of 6 mm thick
600mm dia bore hole with 500mm dia MS casting pipe of 8 mm thick
SITC of Full Bore Electromagnetic flow meter with 0.5Percent calibrated, IP-68, Battery back up, flanged connection, Flow sensor, indicator, transmitter and totaliser with all accessories viz. power and control cables upto starter pannel, cabinets, hardwares 1. Flow sensor:Neoprene / Polyurethene lining, DC pulsed, SS 316 electrodes, CS / SS 316 flanges, Fully welded / SS 304 sensor construction and housing II. Flow Transmitter / converter:Microprocessor based / Modular design / HART type, 2 line back lit LCD for indication of actual flow rate, forward, reverse, sum totaliser display. One current (4 20mA) / one scable pulse / one status output, IP 67, die cast allumunium with PU finish with glass window enclosure, 10 meters length sensor cable (i) 100mm dia
150mm dia
200mm dia
250mm dia
300mm dia
Design asthetically canal bridge with necesaary steel of beam,channel,angles,Chequered plate supported on both side of canal on RCC Block incl. lead paint and priming coat of approved colour. Etc Comp.
Item Description
Manufacture, Supply & Delivery of Electric Resistance Welded (Up to 400mm)/Submerged Arc Welded(Above 400mm) M.S.Pipe having beveled ends plate or coil conforming to IS-3589-2001 or its latest revision/ ammendment for following thickness outside diameter at GWSSB store or site anywhere in Gujarat State including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading conveyance to Departmental stores, stacking etc. all complete. (Rate for MS Pipe based on the ex. works price of HR Coil as Rs.58500 per MT - withouth GST (Above 3.15 mm to 10 mm) & Rs. 59000.00 per MT without GST (Above 10 mm) as onJan-23.( WPI Index of H. R Coil of Dec-22 is 144) I/S Solvent free Liquid Epoxy Lining (406 micron) + O/s LPE Coated M.S. Pipe 508 mm dia (OD), 6.3 mm thick - 1500 MTR.
Providing & supplying D.I D/F sluice valves with ISI mark as per IS:14846 (Latest Edition) or equivalent international standards including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores/Contractor's own stack yard, stacking, stack yard to site transportation charges, etc. complete, including supply, installation complete. PN 1.0 with hand wheel cap operated (PD type Short body) 350 mm dia
Providing and supplying Cast Steel D/F Butterfly Valves confirming to IS 13095 or equivalent international standards with bypass arrangement of 250mm sluice valve & MS Pipe of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, lowering, laying, Installation charges, loading, unloading, conveyance to departmental stores/Contractor's own stack yard, stacking, stack yard to site transfer etc. complete, including nut bolts and giving satisfactory hydraulic testing, etc. complete. 350 mm dia
Providing and supplying Ductile Iron Temper proof Air valves as per AWWA C512 with SS 304 float gun metal nozzle of approved make and quality of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores/Contractor's own stack yard, stacking, stack yard to site transportation charges, etc. complete. 100 mm dia with isolating sluice valve PN-1.0
Excavation for pipe line trenches for water supply, sewerage line, manhole, etc. all with shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site, including all type of dewatering (water incoming in pipeline trenches due to seepage, uplift ground water, rain, surrounding water bodies, etc.) complete for all lifts and strata as specified, including soil, soft murrum, Hard Murrum, boulders incl. macadam road, Soft Rock and/or masonary in CM or LM or Lime Concrete, hard rock and/ or in C.C. 1:2:4 or with blasting and chiselling or by chiselling only. (A)Upto 1.50 m Depth (i.) In all sorts of soil and soft murrum
ii) In Hard Murrum, boulders incl. macadam road
iii)In soft rock and /or masoanry in CM or LM or lime Concrete / Bituminous road
iv)In hard rock and/or in C.C 1:2:4 or RCC with blasting, breaking, chiseling, or by chiseling/breaking only
(B)1.50 to 3.00 m Depth i.) In all sorts of soil and soft murrum
(ii) In Hard Murrum, boulders incl. macadam road
iii)In soft rock and /or masoanry in CM or LM or lime Concrete / Bituminous road
iv)In hard rock and/or in C.C 1:2:4 or RCC with blasting, breaking, chiseling, or by chiseling/breaking only
Lowering, laying, jointing & welding in position to correct line & level M.S. Pipe with outer side 3 LPE coating & inside solvent free liquid epoxy lining on pedestal or chairs upon prepared formation or prepared bedding in trenches the rates include conveyance from store to site of work loading, unloading, field joint coating, 3mm thick heat shrink sleeve confirming to EN 12068 incl. hydro testing etc. complete.
Lowering, Laying and jointing in position following Cast Steel D/F Sluice Valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. 350mm dia
Lowering, Laying and jointing in position following Cast Steel D/F Butterfly Valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. 350mm dia
Lowering, laying and jointing in position following Ductile Iron D/F Air valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. 100 mm dia Air valve with isolating sluice valve PN-1.0
Erection of airvalve riser by installing new MS pipe of 6mm thick and 3.2mt. Length with necessary fittings such as flange of appropriate size, nut, bolts and embedded the pipe in RCC M15 with offset of 10cm around pipe with necessary steel etc. complete Diameter of Air valve 100mm
Construction of valves chambers in brick or bela stone masonary, locally available in C.M.1:6 Foundation concrete 150 mm thick in C. C. 1:4:8 of trap metal size 25 mm to 40 mm thick, inside cement plaster in C. M. 1:3 and cement pointing outside in C. M. 1:3 and top cover of precast RCC slab 100 mm thick (with key hole in two parts, each with handles or MS Bar etc. complete as give size) Upto 1 Mt. depth from G. L. to pipe invert level incl. complete civil works but excl. cost of excavation and refilling. With cast in situ RCC slab in one single piece with fixing of CI-MH Frame and cover (excl. cost of CI-MH Frame and cover) with 23 cm. thk. BM wall in C.M. 1:6. a) Size of Chamber 1.30 x 1.30 m and 1.0 m deep for (valve greater than 250mm dia)
For 1 Mtr. Extra Depth
Providing and casting in situ C.C. in grade M-20 (proportions as per mix design or as per table9 of IS456 2000 in masses by weigh batching ) using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work, including scaffolding centering, formwork, needle vibrated consolidation, curing complete up to 6 meter depth or height excluding cost of reinforcement, with centering and shuttering/deshuttering etc. complete for structure other than water retaining (Below G.L) for Thrust block.
Providing and casting in situ C.C. in grade M-15 ( approx. corresp. to prop. 1:2:4 proportions as per mix design or as per table9 of IS456 2000 in masses by weigh batching ) using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work, including scaffolding centering, formwork, needle vibrated consolidation, curing complete up to 6 meter depth or height excluding cost of reinforcement, with centering and shuttering/deshuttering etc. complete for structure other than water retaining for Encasing of Pipeline.
Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for reservoirs/structures only including lift up to 6 meter height or depth below G.L. for all diameters. Do-CRS steel all diameter FE 500 grade confirirming to relevant IS
Refilling of pipeline trenches incl. ramming, watering, consolidating disposal of surplus stuff as directed within a radius of 3 km.
Drilling of horizontal borehole for water main pipeline under the railway / Road tracks and Canal crossing in all starta with required length incl. fixing of MS casing pipe of suitable size and thickness. Rate includes the cost of drilling of bore hole. Casing pipe & welding pushing etc. complete but excluding the cost of water main, valves and other items. Entire work should be as per Approved Drawing and as per instruction of Railway/ road and Canal crossing Authority for Following Dia. of BoreholeFor MS Pipe. 900mm dia bore hole with 800 mm dia MS casting pipe of 12 mm thick
Flow Transmitter/converter (Remote field Mounted) : Microprocessor based, ,odular design, 2 line LCD for indication of actual flow rate, forward reverse, sum totaliser display, plus or minus 0.5percent accuracy at 0.3 to 4 m/sec velocity. One scalable pulse/one status, one modus output, one GPRS/GSM output, IP 67 protection, Die cast aluminium/polycarbonate/ SS31 with anticorrosive paint/PU finish with glass window enclosure, Inbuilt EEPROM and Data logger, 20 meter cable length for sensor to transmitter communication, minimum 5 years battery lifetime, 3.6 VDC Non rechargeable lithium-thionyl chloride/Ni-Cd high power batteries, Hourly basis worldwide transmission of measured data and events via e-mail and SMS by integrated GSM/GPRS modem, Reliable data storage facility through integrated SD card etc alongwith wall mounted/ stand mounted cabinet. 500mm dia
Item Description
Preparing structural design of RCC Under Ground / Partially under ground / above high ground level Reservoir of required capacity as per relevant I.S. standards and constructing the same, including excavation in all types of soil strata (including rock) including shoring strutting if required, for loose soil / to protect from collapse, casting 100 mm thick P.C.C. levelling course in M-15, Refilling the pit with proper soil and disposing of the surplus stuff at all lead. Including cement plaster in CM 1:2 with approved water proofing compound to all over inside container (i.e. walls, base, top slab/dome bottom etc. all). Including all types of labour and material charges of lowering, laying, erecting / hosting and jointing of pipe assembly to inlet, outlet overflow, washout and bye pass arrangement as per hydraulic design. Providing and fixing accessories, CI Manhole frame and cover, water level indicator, adequate cowl type ventilators or lantern type ventilator with stainless steel jail. RCC chambers for valves. Providing and applying three coats of cement paint / snowcem to the out side face of structure. It also includes satisfactory water tightness test as per relevant I.S. code and painting name of scheme and capacity on the tank as per direction of engineer incharge.List of Indian Standards for Design of GSR / SUMP:- The structural design of GSR shall be in accordance with provisions relevant I.S. (1) I.S. 3370, Part – 1 & 2, 2009 or latest revised. (1.1) I.S. 3370, Part – 3 & 4, 1965 or latest revised. (2) I.S. 456 – 2000 or latest revised. (3) I.S. 1893 – 2000 – 1984 or latest revised (4) I.S. 875, Part – 1 to 3, 1987 or latest revised. General Specifications:- (1) Water depth in container shall be adopted as per data of tender. If water depth is not specified the suitable water depth / acceptable to field engineer in accordance with hydraulic requirement shall be adopted for capacity. (2) Shape of container (in plan) specified by in data shall be adopted in absence circular shape shall be adopted. (3) Size shall be fixed as per availability of space (land area) at site / acceptable engineer in charge. (4) Effect of overlapping of pressure bulbs on soil due near by structure and proposed sump should be considered. (5) Care shall be taken that no damage should occur to nearby existing structure. Compensation shall be paid for the same by agency.(6) The minimum concrete grade for RCC shall be M-30 (7) HYSD Fe 415 / 500 grade reinforcing bars confirming to I.S. 1786 / 1139 shall be considered in design. CRS / TMT bars shall be provided. In saline atmosphere corrosion resistance stainless steel / HCR rebar shall be provided. Any other steel can be used with approval of C.E./ in situation of non availability in market without extra cost. (8) Minimum size (or thickness) of various components shall be provided as per tender criteria / specifications in absence as per I.S./ Std. practice of G.W.S.S.B. Minimum dimensions specified for various components in tender data / specifications shall be provided without fail. (9) The safe bearing capacity (SBC) shall be referred from SBC test report. In absence of report it shall be referred from data sheet. If poor soil is found / water table is met with during excavation SBC shall be scientifically ascertained and design shall be revise. No extra shall be paid for increase in quantity. (10) DI/CI pipes and special shall only be used if type is not specified in tender. (11) The rate shall include cost of dewatering during excavation making all arrangement when water table meets within depth. (12) The structure shall be designed properly to resist uplift due to ground water table specified in data or actual ground water table meets with during excavation. No extra shall be paid. If GWT / Uplift is mentioned in tender and during excavation it does not meet 7.5Percent rate shall be reduced.(13) SS pipes railing shall be provided when sump is more than 2 meter above ground level. (14.a) RCC staircase /RCC steps should be provided from GL to sump top slab based on the height of the GSR above/Below the ground. (14.b) RCC Staircase with SS railing to be provided inside reservoir container. BB Masonry staircabin to be provided to cover the same with MS safety door having locking arrangement. (15) Appearance of structure should be aesthetically good looking acceptable to authority. (16) Any charge in size, shape, depth below GL, height above GL, water depth, F.B., size of member etc can be permitted in exceptional case due to site condition or hydraulic design requirement by C.E. No extra shall be paid for change. (17) Any charge in data, dimensions, shape, water depth, reduction in size if permitted by competent authority and if it reduces quantity then payment shall be reduced prorate. (18) When capacity of GSR / Sump is > 20 lakh liters two or suitable compartments acceptable to executive engineer shall be designed and provided. (19) Agency shall engage qualified (at least graduate) consulting engineer for designing the structure and he / she shall visit the site for guidance of work. (20) 75Percent part rate shall be payable for concrete, reinforcement and plastering items of container until satisfactory hydraulic testing for water tightness is performed as per tender condition. Till the work shall be treated as incomplete. Above conditions / general specifications Sr. No. 1 to 20 are part and parcel of tender (contact) and prevail over other provisions in tender. As above without water table (Sub soil water level Below foundation) R.C.C.Partially Under Ground Rectangular Clear Water Sump as below Capacity as detail given in tender Without Water table. (I) 12.00 Lakh Lit U/G Sump At Savarakha Shw
10.00 Lakh Lit U/G Sump At Morthal Shw
8.00 Lakh Lit U/G Sump At Duva SHW & Bhordu Boosting st
7.00 Lakh Lit U/G Sump At Bordu SHW
4.00 Lakh Lit U/G Sump At Meghpura Shw
As above without water table (Sub soil water level below foundation) (i) 40,000 Lit U/G Sump
60,000 Lit U/G Sump
70,000 Lit U/G Sump
80,000 Lit U/G Sump
90,000 Lit U/G Sump
1,00,000 Lit U/G Sump
1,10,000 Lit U/G Sump
1,20,000 Lit U/G Sump
1,30,000 Lit U/G Sump
1,50,000 Lit U/G Sump
1,60,000 Lit U/G Sump
1,70,000 Lit U/G Sump
1,80,000 Lit U/G Sump
2,00,000 Lit U/G Sump
2,10,000 Lit U/G Sump
2,20,000 Lit U/G Sump
2,50,000 Lit U/G Sump
Designing structurally (and aesthetically) complying provisions of relevant Indian standards and constructing RCC Elevated service Reservoir of the following capacity and height , using latest Soil Investigation Report of proposed site , Seismic zone, Wind speed Zone. Including (1) Container shape any suitable type(or as specified), (2) Staging consisting of column brace trestle / shaft / combination column- brace trestle and shaft as appropriate(or as specified) and (3) Appropriate foundation system. This includes excavation in all types of soil strata(including hard rock ), casting100 mm thick P.C.C. levelling course in M-10 , Refilling the pit with proper soil and disposing of the surplus stuff at all required lead. (4) This will also include cement plaster in CM 1:2 with approved water proofing compound all over inside container (i.e. walls, base, top slab/dome bottom etc. all).. (5) All types of labour & material charges of lowering , laying, erecting / hoisting & joining of pipe assembly of Inlet, Outlet, overflow, washout and bye pass arrangement as per hydraulic design are including. (6) Providing and fixing of any accessories(specified), CI Manhole frame and covers, water level indicator , lightening conductor, GI Pipe railing around walk way, at roof level, at gallery and around landing of inside shaft, Adequate cowl type ventilators or lantern type ventilator with stainless steel jali. (7) Scope of work includes constructing RCC spiral staircase with adequate tie beams,staircase footing ,Rcc chambers for valves. ventilating shaft and ventilators as well as door in shaft, SS grating to be provided to outlet pipe (inside container) for safety.(8) including providing and applying three coats of cement paint/snowcem (as specified) to the whole structure. (9) It also includes satisfactory water tightness test as per relevant I.S. Code and painting name of scheme & capacity on the tank as per direction of engineer in charge. List of Indian Standards for design of ESR: List of Indian Standards for design of ESR:(1) I.S. 3370 part I & II 2009 or Its latest revision(1.1) I.S. 3370 part III & IV 1965 or Its latest revision(2) IS 456-2000 or Its latest revision(3) IS 11682- 1985 or Its latest revision(4) IS 1893-2002 part I to V or Its latest revision(5) IS 13920-1993, or Its latest revision(6) IS 875 part I to III,1987 or Its latest revision(7) IS 11089- 1987 or Its latest revision General specifications:(1) The Min. concrete grade for RCC shall be M:30. Proportion of concrete ingredients shall be as per Mix design using weigh batching. (2) HYSD( Fe 415)or higher grade reinforcing bars confirming to IS 1786/1139 or CRS /TMT bars shall be used as per detailed specification. (3) Incase of column –brace trestle type staging having more than 6 columns internal horizontal bracing is obligatory. One bracing shall be at foundation level incase of Individual footings . (4) Min. size/ thickness of various components shall be provided as per design criteria/specifications/IS Code ( or as per std. practice ) . Capacity of the ESR shall be considered excluding free board.(5) Minimum dimensions specified for various components in tender data /specifications shall be provided. (6) The Safe bearing capacity (SBC) /allowable pressure on soil shall be referred from SBC test report or tender datasheet. If poor soil strata is met with or ground water table is encountered, the SBC shall have to be re ascertained and the design shall be revised accordingly.(7) Maximum spacing between horizontal bracings shall be 5 m(storey height). (8) The BB Masonry cabin with MS door shall be constructed when spiral staircase is outside the staging.(9) RCC Staircase/M.S. Staircase shall be provided and fixed for access to roof when height of roof from G.L. is up to 10 m. For ESR having more than 10 m height proper RCC satircase or suitable RCC spiral staircase shall be constructed. Railing should be provided through out the staircase and around the top ring beam. (10) For ESR-having staging height more than 15 m the spiral staircase shall be provided inside the staging with effective tie beams in more than one direction.(11) Water level indictor shall be provided and fixed float type /electronic (as specified ).(12) The rate shall include providing and fixing pipes, specials, and valves required for inlet, outlet , wash out, over flow and bye pass arrangement. The scope of work includes constructing supporting RC pillars, erecting, laying ,fixing and joining pipes and specials etc up to 5m length from face of staging (outer most column). (13) DI/CI pipes & specials shall only be used .(14) The rate shall include cost of dewatering during execution making all arrangement and any dewatering technique.(15) The structure shall be designed properly for uplift due to Ground water table specified in data or GWT encountered during excavation.No extra payment shall be paid for the same.(16) Effective curing shall be carried out up to required period as per specifications.(17) Agency shall engage qualified (at least graduate)consulting engineer for designing the structure and he/she shall visit the site for guidance of work at all level (i.e. below foundation, up to GL for all lifts up to containers). (18) 75 Percent part rate shall be payable for Concrete, Reinforcement and Plastering items of container until satisfactory hydraulic testing for water tightness is performed or as per tender condition .Till then the work shall be treated as incomplete. Above conditions / general specifications Sr. No. 1 to 18 are part and parcel of tender (contract) Capacity of ESRs ( Shell type containers like cylindrical, conical, intze, folded plates & its combination) For Seismic Zone-4 Capacity (i) 6.00 Lacs Lit and 20.0 Mtr HT. Savrakha SHW
5.00 Lacs Lit and 20.0 Mtr HT. Morthal SHW
4.00 Lacs Lit and 20.0 Mtr HT. Duva SHW
3.00 Lacs Lit and 20.0 Mtr HT. Bhordu SHW
Designing (aestherically ) and constructing RCC framed structure earth quake proof pump House in M:300 mix. As per design with reinforcement / steel should be TMT steel Fe-500 as per relavent IS Only to be used. Requirement and specification at various site.incl. All associated civil works lke connection to sump through inlet pipe,pumping machinery foundation,thrust block in pump house suppoting work to headder main,jungle cutting,site clearnance and debris removal,required lighting work and wiring as per requrement,point Door window As per requirement Fan ponit chain pully arangement for Pumping Machinary etc. complete.Note:- 1. Minimum 15 Percentage opening for ventilation should be provided.2. Pump room rolling shutler, door and windows of aluminium section and window grill of iron should be provided (Included in Cost). 3. Plinth level of Pump house should be min.1 meter above GL 4.Cost does not include foundation for pumping machinery. (i) 15 mt X 10.0 mt. size & 6.0 mt, clear heigth from plinth level to top slab beam bottom Positive Suction Pump House At Savarkh SHW, Kesargam SHW, Morthal SHW,Bhordu SHW, Darbari Dental SHW, Duva SHW,Arantva SHW- 7 Nos
18 mt X 10.0 mt. size & 6.0 mt, clear heigth from plinth level to top slab beam bottom Positive Suction Pump House At Meghpura SHW
25 mt X 12.0 mt. size & 6.0 mt, clear heigth from plinth level to top slab beam bottom Positive Suction Pump House At Didarda SHW
60 mt X 10.0 mt. size & 6.0 mt, clear heigth from plinth level to top slab beam bottom Positive Suction Pump House At Bhapi MHW
At Bhordu Boosting Station without gantry 10 mt X 5 mt. size & 3.6 mt, clear heigth from plinth level to top slab beam bottom Without Gantry structure (Upto 3.60 M)
At various village level without gantry 3 mt X 3 mt. size & 3.6 mt, clear heigth from plinth level to top slab beam bottom Without Gantry structure (Upto 3.60 M)
Designing (aestherically), and Constructing Earthquake Proof R.C.C. Frame Structure Staff Quarters incl. using Iron Frame for Door & Shutter & Plywood sheet door/windows min. 35 mm thick, 15 mm thick Single Coat Cement Plaster in CM 1:3 Inside & 20 mm thick sand face Cement Plaster in CM 1:3 Outside, Filling Excavated Earth in Plinth, RCC Work in M:200, M.S. Stair Case Out Side the Quater, Using White Glazed Tiles in Bathroom, W.C. & Flooring, Vitrified tile Flooring of C.C 1:2:4 For All room , UPVC Pipe Connection for Water Supply In Bathroom, W.C. & Kitchen, 140 mm Dia PVC Pipe line for Drainage, Sockpit, Septic tank, Inspection Chamber, Consealed Light Fitting as per Design & two coat Oil Painting eith primer for Door, Window & Ventilator, two coat Palstic Paint Work with primer & Lappy putty in inside of Qtrs. & two coat Weather proof Exterior Emuision paint of Qtr. etc. Complete as per Design & instruction of EIC. Off take and Tharad Staff Quarters-280 Sq.Mt Rest house cum office Tharad-250 Sq.Mt
Item Description
Supply, Installation , Testing and Commissioning of Pump Set with Piping, Accessories and Electrical Equipment various Headworks and Sub Headworks as per drawing and detailed technical specifications : - HSCF Pump : Design, engineering, supply, installation, testing and commissioning of mechanical and electrical equipment of water supply pumping system viz pumping machinery of following type and rating), Valves (SV/BFV/DPCV/TPAV/ACV), Suction-Delivery-Discharge header pipes and specials, expansion bellows, full bore electromagnetic flow meter,Pressure Gauge, material handing system (EOT) ,RCC Chamber, Dewatering Pump, Drain Pump,11 KV two/four pole switch yard with distribution transformer (with standby of identical full load capacity),wire fencing, M.S. Gate, 11 kV HV Cables, Terminations Kits,Neutral Grounding Resistors, HV swith gear panel,FCMA Starter, LV MCC-APFC panels, LV XLPE insulated Cu / Al armoured cables with tray and kits,Capacitor Bank, Battery and Battery Charger,Fire and Safety equipments,Level Switch, Level Transmitter, Pressure Transmitter, earthing system with PLC based instrumentation with control system as per detailed specifications including dismentaling of existing pumping machineries and accessories to departmentalstore as per instruction of engineer in charge. - Manufacture, Supply, Delivery and Lowering Laying of MS Pipe and MS specials as per relevant IScodes. - Providing, Supplying, Lowering and Laying of Butterfly Valves, Sluice Valves , Dual Plate Check Valves, Temper proof Air Valves, expansion bellows and pressure gauges as per relevant IScodes. - SITC of full bore electromagnetic flow meter as per relevantstandard. - Providing and erecting control panel and MCC panel with suitable motor starter .- Providing and erecting APFCR panel consist of capacitor bank for continuous duty to improve PowerFactor. - Providing and erecting XLPE armoured cable including MS ladder type cable tray as per relevant standard. - Supplying and erecting Funnel type earthing including HOT deep Galvanised Strip for earthing as per relevantstandard.- Non Contract Type Radar / Ultrasonic Technology Based water level measuring device.- Providing and erecting miscellaneous items like rubber mat, metallic vertified danger notice board, Printed instruction chart bothin English and Gujarati, First aid box, FIRE bucket round bottom of 9 lit. capacity and floor mounting stand for keeping 4 nos of firebuckets. 45 KW x 4 set Equal to 180 KW (Capacity 300 M³/Hr x 35 meters head) (21.18.5 KW x 4 set Equal to 74 KW (Capacity 100 M³/Hr x 40 meters head) (2 Working + 2 Standby) HSCF Pump (Meghpura Pro PH to Meghpura Ex ESR) 2. 18.5 KW x 4 set Equal to 74 KW (Capacity 80 M³/Hr x 46 meters head) (2 Working + 2 Standby) HSCF Pump (Meghpura Pro PH to Morthal Pro Sump) 3. 15 KW x 4 set Equal to 60 KW (Capacity 100 M³/Hr x 30 meters head) (2 Working + 2 Standby) HSCF Pump Savarkha Sump to ESR 4. 30 KW x 4 set Equal to 120 KW (Capacity 200.41 M³/Hr x 36 meters head) (2 Working + 2 Standby) HSCF Pump kesargam Prop PH to Ex ESR 5. 37 KW x 4 set Equal to 148 KW (Capacity 200 M³/Hr x 41 meters head) (2 Working + 2 Standby) HSCF Pump Darbari Prop Sump to Ex ESR 6. 18.5 KW x 4 set Equal to 74 KW (Capacity 100 M³/Hr x 40 meters head) (2 Working + 2 Standby) HSCF Pump Morthal Prop Sump to Prop ESR 7. 18.5 KW x 4 set Equal to 74 KW (Capacity 100 M³/Hr x 41 meters head) (2 Working + 2 Standby) HSCF Pump Duva Prop Sump to Prop ESR 8. 11 KW x 4 set Equal to 44 KW (Capacity 50 M³/Hr x 40 meters head) (2 Working + 2 Standby) HSCF Pump (Didarda Sump to ESR) 9. 11 KW x 4 set Equal to 44 KW (Capacity 50 M³/Hr x 45 meters head) (2 Working + 2 Standby) HSCF Pump (Didarda Sump to Bhordu Pro Sump) 10. 15 KW x 4 set Equal to 60 KW (Capacity 60 M³/Hr x 41 meters head) (2 Working + 2 Standby) HSCF Pump Bhordu Prop ESR 11. 30 KW x 4 set Equal to 120 KW (Capacity 200 M³/Hr x 36 meters head) (2 Working + 2 Standby) HSCF Pump Arantva Prop PH to Ex ESR
Supply, Installation , Testing and Commissioning of Pump Set with Piping, Accessories and Electrical Equipment various Headworks and Sub Headworks as per drawing and detailed technical specifications : - HSCF Pump : Design, engineering, supply, installation, testing and commissioning of mechanical and electrical equipment of water supply pumping system viz pumping machinery of following type and rating), Valves (SV/BFV/DPCV/TPAV/ACV), Suction-Delivery-Discharge header pipes and specials, expansion bellows, full bore electromagnetic flow meter,Pressure Gauge, material handing system (EOT) ,RCC Chamber, Dewatering Pump, Drain Pump,11 KV two/four pole switch yard with distribution transformer (with standby of identical full load capacity),wire fencing, M.S. Gate, 11 kV HV Cables, Terminations Kits,Neutral Grounding Resistors, HV swith gear panel,FCMA Starter, LV MCC-APFC panels, LV XLPE insulated Cu / Al armoured cables with tray and kits,Capacitor Bank, Battery and Battery Charger,Fire and Safety equipments,Level Switch, Level Transmitter, Pressure Transmitter, earthing system with PLC based instrumentation with control system as per detailed specifications including dismentaling of existing pumping machineries and accessories to departmentalstore as per instruction of engineer in charge. - Manufacture, Supply, Delivery and Lowering Laying of MS Pipe and MS specials as per relevant IScodes. - Providing, Supplying, Lowering and Laying of Butterfly Valves, Sluice Valves , Dual Plate Check Valves, Temper proof Air Valves, expansion bellows and pressure gauges as per relevant IScodes. - SITC of full bore electromagnetic flow meter as per relevantstandard. - Providing and erecting control panel and MCC panel with suitable motor starter .- Providing and erecting APFCR panel consist of capacitor bank for continuous duty to improve PowerFactor. - Providing and erecting XLPE armoured cable including MS ladder type cable tray as per relevant standard. - Supplying and erecting Funnel type earthing including HOT deep Galvanised Strip for earthing as per relevantstandard.- Non Contract Type Radar / Ultrasonic Technology Based water level measuring device.- Providing and erecting miscellaneous items like rubber mat, metallic vertified danger notice board, Printed instruction chart bothin English and Gujarati, First aid box, FIRE bucket round bottom of 9 lit. capacity and floor mounting stand for keeping 4 nos of firebuckets. (Design of HT side cable,11KV/0.433KV transformer(With Standby), VCB(1 I/C and 4 O/G)(2Nos For Exsiting Sipu RWSS Transformers), LT side cable/Bus duct from Transformer to PCC/PMCC panel,APFC Panel,other necessary accessories,etc.Should be Done Considering Load of Bhapi West section , (i) 1. 55 KW x 4 set Equal to 220 KW (Capacity 120 M³/Hr x 99 meters head) (2 Working + 2 Standby) HSCF Pump (Bhapi Ex HW to Meghapura Ex Sump) 2. 18.5 KW x 4 set Equal to 74 KW (Capacity 100 M³/Hr x 40 meters head) (2 Working + 2 Standby) HSCF Pump (Bhapi Pro PH to savarkha Pro Sump) 3. 30 KW x 4 set Equal to 120 KW (Capacity 100 M³/Hr x 65 meters head) (2 Working + 2 Standby) HSCF Pump (BhapiPro PH to Didarda Ex Sump) 4. 45 KW x 4 set Equal to 180 KW (Capacity 150 M³/Hr x 62 meters head) (2 Working + 2 Standby) HSCF Pump (Bhapi Pro PH toKesargam Ex Sump) 5. 110 KW x 4 set Equal to 440 KW (Capacity 300 M³/Hr x 87 meters head) (2 Working + 2 Standby) HSCF Pump (Bhapi Ex PH to Bhordu Boosting Station) 6. 55 KW x 4 set Equal to 220 KW (Capacity 160 M³/Hr x 81 meters head) (2 Working + 2 Standby) HSCF Pump (Bhordu Boosting to Arantva Ex Sump) 7. 55 KW x 4 set Equal to 220 KW (Capacity 140 M³/Hr x 83 meters head) (2 Working + 2 Standby) HSCF Pump (Bhordu Boosting to Darbari Detal Ex Sump)
SITC of Horizontal mono submersible pump set Monoset sub. pump 3 phase 400/440 vott, 50 c/s. A.C. Supply and 2900 RPM , as per IS 14220 MOC : Casing: CI-FG260, Impeller : Bronze and Shaft : SS:41 (Rates exclusive of GST) (i) SM-2.1, 220 LPM, 22.5 m Head and 4 HP
SM-2.7, 690 LPM,40 m Head and 15 HP
SM-2.2, 360 LPM, 24 m Head and 5.5 HP
SM-2.5.3, 720 LPM, 25 m Head and 10 HP
SM-2.5.4, 900 LPM, 37 m Head and 15 HP
SM-2.5, 498 LPM, 32.5 m Head and 10 HP
SM-3.6, 1175 LPM, 37 m Head and 20 HP
SM-3.4, 870 LPM, 32.5 m Head and 15 HP
SM-4.4, 1250 LPM, 25 m Head and 15 HP
SM-4.6, 1500 LPM, 30 m Head and 20 HP
SM-4.7, 1860 LPM, 34 m Head and 25 HP
Providing, Supplying, Lowering, Laying and jointing of ISI mark G.I. pipes (IS 1239) with couplings and GI specials For Delivery, Header and Inter Connection Of Sump of following class and diameter in proper position, grade and alignment as directed by Engineer-In-Charge including conveyance from stores to site work, labour, giving hyrdraulic testing including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc, complete (1) 65 mm dia
80 mm dia
50 mm dia
100 mm dia
Manufacture, supply and delivery of MS / GI special flange ended including all taxes. Upto 300 mm dia.
Manufacture, supply and delivery of GI Fitting including all taxes. (Elbows,nipple,Stepnipple,union,plug,Tee,coupling,reducer) up to 65 mm
Above 65 mm and 100 mm
Providing, supplying, Lowering and Laying of ISI mark CI D/F reflux valve as per IS:5312 (Latest Edition) of following class and dia. Including all taxes, insurance, transportation, freight charges, octroi, Inspection charges, Loading, Unloading, Conveyance to departmental store, stacking etc. complete. (1) 50 mm dia
65 mm dia
80 mm dia
100 mm dia
Providing, supplying, Lowering and Laying of ISI mark CI D/F sluice valve as per IS:14846 (Latest Edition) of following class and dia. Including all taxes, insurance, transportation, freight charges, octroi, Inspection charges, Loading, Unloading, Conveyance to departmental store, stacking etc. complete. (PN 1.0 Hand wheel/Cap operated (PD type short body) (1) 50 mm dia
65 mm dia
80 mm dia
100 mm dia
Pressure Gauge with Accessories: Design , Supply, installation, testing and commissioning of Bourdon type pressure gauge ,+-1percent accuracy, Direct bottom 1/2" NPT (M) process connection ,IP 667, Glycerine filled ,SS304 Case with BAyonet Type Bezel,SS316 L Bourdon Tube, SS 316 Movement material ,Aluminium Dial with black graduation on white background, Micro Zero adustable pointer , neoprene gasket ,Blow out disc ,shatter proof glass, SS tag plate etc as per IS 3624 of . 0-10 kg/cm2
SITC of Approved make Four Pole LT Heavy Duty Switch Disconnector Fuse Unit Cubical type for panel mounting complete with operating mechanism suitable to operate on 415V A.C. With HRC fuses of suitable load confirming to IS. 13947 and errected on angle iron frame duly painted as per relevent IS specification with red oxide as per Tech. Speci. Cat:III for receiving GEB power (a) 32A, Cat-III
63A, Cat-III
Supply, installation, testing and commissioning RandB Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on 3 phase and neutral 415V. having characteristic of quick action and tripping with all advance feature and do not incorporate any electronic component for following Max. rating erected as directed. (a) 25A, FP, Cat-III
63A, FP, Cat-III
D.O.L. FROM 5 TO 7.5 HP
S.D. FROM 8 TO 10 HP
S.D. FROM 11 TO 15 HP
S.D. FROM 16 TO 20 HP
ATS FROME 21 TO 30 HP
1.1kV Grade Cable- Copper Conductor: Supply, laying, testing and commissioning 1.1 kVgrade, XLPE insulated ,stranded Copper conductor, galvansised steel flat strip / round wire Armoured, exruded PVC type ST2 shealthed, heavy duty cable conforming to IS 7098 (Part-I) and IEC 60502 / 1988 for 1100 Volts grade of approved make with glanding and termination with suitable size lugs / bolts and nuts with all required materials and labour. Cable shall be laid on wall surface with necessary clamps / in existing cable trench/ CAble trays / conduit / pipe sleeves at road crossing or floor as per site requirement. From GEB meter to Control Panel (i) 4C X 4 Sqmm
4C X 6 Sqmm
4C X 10 Sqmm
4C X 16 Sqmm
PVC Insulated Flat / round submersible Copper Cables (Rates exclusive of GST) SITC of PVC insulated flat submersible cable as per detailed technical specifications of R/C of GWSSB conforming to IS 694, IEC 60227 /60228. - From Control Panel to Motor (i) 3C X 2.5 Sqmm
3C X 4 Sqmm
3C X 16 Sqmm
Supplying and erecting funnel type earthing having earth plate of following size burried in specifically prepared earth pit 3 m below ground with 40 kg. charcoal and salt with alternate layer of charcoal and salt, 20mm dia GI pipe with funnel with a wirmesh for water and brick masonry block CI cover complete as per para 7.3 of IS 3043 with necessary length of double GI/Couper earth wire No. 6 SWG bolted with lug to the plate and cover in 12mm dia GI pipe 2.5 mt. long completed connected to the nearest swichgear with end socket as per direction and duly tested by earth tester confirming to ISS with following specifications. A) with 30 x 30 x 0.35 cms CI earth plate
Supplying Rubber Matting of 4.00 mm thickness as per IS 5424 and of require length and breadth with good insulation property for 22kv (1.5 m width x 14 m)
Providing and Laying Reinforced Cement Concrete in Thrust Block/Piping/Valves Supports etc. with Tar steel, Black Trap Kapchi as Coarse Aggreate for Raft,Grillage Footing with Necessary Centering Form work, Consolidating as per Directive in 1:2:4 Ratio comp. as per site requriement.
Item Description
Compound wall Excavation for foundation up to 1.50 m Depth including Sorting out and Stacking of useful materials and disposing of the excavated stuff up to 50 meter lead. (a) Loose or soft soil
Providing and laying cement concrete 1:3:6 (1cement : 3coarse sand : 6 hand broken stone aggregates 40 mm. nominal size) and curing complete excluding cost of from work in :(a) Foundation and plinth
Providing laying controlled cement concrete M-200 and curing complete excluding the cost of form work and reinforcement for reinforced concrete (a) Foundations, footings Base of columns and mass concrete. work in :
Providing and laying controlled cement concrete M-200 exposed work with curing etc. complete including the cost of form work but excluding the cost of reinforcement for R.C.C. work in :(a) BEAMS : Having cross sectional area 0.05 to 0.08 Sq.Mt.
(b) BEAMS : Having cross sectional area more than 0.08 Sq. M. and up to 0.12 Sq. M.
(c) COLUMNS :Having cross sectional area 0.05 to 0.08 Sq.Mt.
Brick work using common biurnt clay building brick having crushing strength not less than 35 Kg/ Sq.cm.in foundation and pilnth in cement mortar 1:6 ( 1 Cement:6 find Sand)( Conventonal)
Filling availbale excavated earth (Excluding rock) in trenches Plinth, sides of foundation etc.in layers not exceeding 20 cm in depth Conolidating each deposited layers by ramming and watering
Brick work using common burnt clay building brick having crushing strenght not less than 35 kg/sq.cm.in foundation and plinth in cement mortar 1:6 fine sand) (Extra for brick in super structure above plinth level up to floor two level) Conventional
Providing TMT bar FE 500D reinforcement for RCC work including,bending.binding and placing in position complete up to floor two level.
Providing 15 mm thick cement plaster in single coat on Rough side of single or half brick walls / concrete wall for interior plastering up to floor two level finished even and smooth in (i) Cement mortar 1:3
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on wall surface (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.
Providing and fixing 0.70 meter high fencing with 1.50 meter long M.S. Angle posts 50 mm. X 50 mm. X 6 mm. And Painting of 1 coat Ready mixied Red lead Paint and 2coats oil paint fixed at 3.0 mt. c/c with nine horizontal lines of galvanised steel barbed wire weighing 9.38 Kg. Per 100 meter, strained and fixed to posts with G.I. staples, including fixing posts on wall etc. complete.
Demolition of Brick work and Stone masonary including stacking of serviceable materials and disposal of unserviceable material with all lead and lift
Providing & fixing sliding gate of 40 mm. dia. mild steel pipe 'B' Class all roundand 20 mm. dia. mild steel pipe at 200 mm C/C and 12 mm. mild steel square bars at 200 mm. c/c alternatively i. e. One square bar to 40 mm dia. pipe frame as per drawing and design with necessary brackets,between two pipe vertically welded holdfasts, locking arrangement on top & aldrop on both sides including base rail for sliding the gate Flat with holdfast, fabrication of side supports including fixing the lettershaving ball bearing rollers & guide track of 50 X 6 mm. M. S. Flat with holdfast, fabrication of side supports including fixing the letters GWSSB on front side etc. complete with three (3) coats of approved Oil Painting & one cost of red oxide primer as directed , include the cost of reinforcement, column supports, joists, concrete masonry work and lighting arrangement etc Complate.
CC Road Box cutting the road surface to proper slope and camber for making a base for road work including removing the excavated stuff and depositing on the road side slops as directed upto 50 Mt. lead
Providing and laying compacted W.B.M. 150 mm thick of machine crushed B.T. metal of size 45 mm to 63 mm with using 0.12/ cmt./10 Sqm stone screenings as filler and binding material 0.06 cum./ 10 Sqm. including spreading, watering & consolidation by vibratory roller etc complete.
Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mmnominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
Providing and casting in Control cement concrete M.150 for C.C. Road including compaction and finishing by trimix process, including providing construction, contraction and expansion joint and filling in joints with bitumen etc. complete as directed by engineer in charge.
Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level
Supplying and erecting LED Solar street lights with High power White LEDs wattage of 1Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses with company mark/name engraved or embossed with 36 hours battery backup & MPPT 24V,7.5 A charge controller with 12 hours automatic switch on/off with wind speed resistance 44 m/s as per IEC 61215 (E) 36W, 3000 lumens, IP-65, PV Module -2x100W and 6 mtr poles complete erected
Providing and Fixing precast Rubber Dye inter locking concrete block 60 mm thickwith grade of concrete M250 pnumatic compressed by mechanically pressed and as per approved design including 75 mm sand layer for levelling and filling the joint with sand in proper line and level inc. necesaary excavation & PCC in grade M-10 (1:3:6) thickness not less than 0.15 mt etc comp.
Earthwork for embankment including breaking clods, dressing with all lead and lift and including watering rolling and consolidation of subgrade in layers at O.M.C. to required dry density including filling the depression which occur during the process using power roller 8T to 10T.(E) From Borrow area within 6 KM. lead (upto 10 ton)
Clearing and grubbing road land including uprooting rank vegetation grass bushes,shrubs,sapling and trees girth up to 300 mm removal of stumps of trees cut earlier and disposal of unserviceable materials(D) By mechanical means in area of Light jungle
Plantation of trees in soil incl digging 45 x 45 x 45cm size pits, preparing soil, providing and mixing organic fertiliser , watering, planting and filling the pits as per direction including etc comlete.
Providing Tree Plants having minimum 1.00 mt height and healthy growth of various kinds as like Peltoform, Gulmahore, Karanj, Ambla ,Rain tree, Saptparni, Cherry, Cryjeliya, Spethodiya, Paras Pipala, Garmalo, Neem, Borsalli, Kadam, Buch, Chanpo, Asopalav and as suggested etc
Providing and fixing gun metal check or non-return full-way contoll wheel valve 40MM dia.
Providing and laying in trenches 6.0 Kg. F/Cm2 working pressure PVC pipes for water supply line of the following outside dia. having white colour complete with necessary fittings, clamps etc (B) 50 mm
Providing and laying in trenches 6.0 Kg. F/Cm2 working pressure PVC pipes for water supply line of the following outside dia. having white colour complete with necessary fittings, clamps etc (A) 32 mm
Lawn Grass :- Filling the area up to the depth of23 cm. with good quality of field fertile soil, breaking the clods leveling the area, free from stone grass roots etc. and farm yard manure at the rate of 5 cum. Per 100 sq. mt. mixing the same with layer of soil, levelling rolling, pre planting, watering etc. and planting the lawn grass of approved varity at 10 x 10 cm. distance etc. complete as per detail specification and maintance for 3 months.
Providing and fixing 1.20 Metre high fencing with 2.0 Metre long M.S. Angle posts 40mm x 40 mm x6 mm and oil painting 3 coats fixed at 2.5 Mt,C/c. with five Horizontan lines and two diagonals of galvanised steel barbed wire weighting 9.38 Kg. per 100 Metre, strained and fixed to posts with G.I,staples including fixing the postsin ground with 0.5 M x 0.5.M x 0.5 M. block in C.C1:5:10 etc complete.
Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 30cm length,30cm height and 15cm thick of M250 grade concret as per approved design and including excavation for fixing in proper line and level,filling the joint with C:M 1:3 (1cement:3fine sand) etc complete. (upto 10 ton)
Providing & Supplying Wooden Executive Table Having Size of 1800 (L) X 1000 (W) X 760 (H) mm with necessary wooden with 8mm glass on laminated top supports and framing of 18 mm thick BWP plywood or equivalent and 1 mm thickness Laminate/Veneer with cost of all material & Labours with inside one primer coat Colour, SS Studs and box with Three Drawers & necessary fixtures and fastenings. The work shall be done as per drawing or directed by Engineer Incharge.
Providing & Supplying Wooden Office Table with laminated top having 1520 (L) X 900 (W) X 760 (H) using 18 mm thick BWP plywood & 25mm & 50mm X 12mm Teakwood patti, formica, handle, fastening & fixture including cost of all material & Labours with drawer & shutter, inside one priming coat and two coat of oil painting. etc. complete as per drawing or directed by Engineer in charge.
Providing & Supplying Wooden Computer Table (Modular Type) having size 1.20m Length X 0.70m Width X 1.20m Height with box size 0.45 X 0.53 X 0.70m Height with 03 drawers with Keyboard tray, using 18mm/12mm/6mm WP plywood, laminate sheet, teak wood, lumpsum Two Glass, necessary hardware, fixtures & fastening including Labour charges, CPU trolley, polishing were required etc., as directed by the Engineer in Charge.
Providing & Supplying Wooden Three Seated SOFA made using Indian Teak wood in framing and support of 19mm thick WP plywood, box of the sofa made with 100mm Thick 40 Density 'U' foam in seat and 50mm Thick 40 Density 'U' foam in back rest portion with imported POLYTEEL recron covering on back portion with textured TAPESTRY black Leather covering and S.S. legs with necessary fixtures & fastening etc., competed or as directed by Engineer in Charge.
Providing & Supplying Curtain of Vertical Blinds with runners, blind fabric, roller thread manual, powder coated channel with necessary fittings, fixtures & fastening for moving of blinds, etc. completed as directed by Engineer in Charge.
Providing & Supplying Visitors Chair E-PRO Cantilever BB-EP1-CT.
Providing & Supplying Revolving Swing Mid back chair BB-SG-02 D, with permanent contact single position locking mechanism, 5-prong low rise chrome base fitted with twin wheels of nylon castors, elegant chrome base armrest. Premium pneumatic gas lift and elegant nylon mesh for seat and back.
Providing & Supplying Armada Mid Back Chair BB-AR-02-C single position locking Synchro tilt mechanism with 'return-prevention' facility with heavy duty with nylon castors wheels elegant fabric, upholstery for seat and nylon mesh for back etc.
Providing & Erecting Split Air Conditioners 2 ton min. 5 star or above rated approved make air-conditioning unit consisting of condensing unit with fan motor, hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means of proper insulated copper tubing upto 5 RMT as per suitable, cost inclusive of M. S. stand, Gas charging & internal copper wiring & remote control etc. complete as per directed by the Engineer in Charge.
Providing & Supplying Wooden Dias Platform for CONFERENCE HALL/DEE Room having Size of 2000 (L) X 1500 (W) X 200 (H) mm using with 18 mm BWP plywood structure & Wooden Beading as per drawing or directed by Engineer in Charge.
Providing & fixing PVC Decorative Luvar Wall panels & Ceiling Panel with ambient Lighting arrangement (Roof light, Panel Light etc) as per direction of Engineer incharge.
Item Description
Second Year
Third Year
Fourth Year
Fifth Year
Sixth Year
Seventh Year
Eight Year
Nine Year
Ten Year
Inside Out side Painting to all Functional civil structures, as per schedule (Four time in the contract period) Distempeing (Two Coats) with oil bound distemper of approved brand and manufacture and of required shade on wall surfaces to give an even shade, over and including a priming coat with distemper primer of approved brand and manufacure after throughly brushing the surface free from mortar dropping and other foreign matter and also including preparing the surface even and sand papered smooth. UG sump, Pump house, Staff Quarter,Compund wall etc. Painting Inside/Outside to WTP inc. all buildings, RCC UG Sump, Pump room,Staff Quarters,Compund Wall etc. 1 st Quarter . Bhapi Main HW
Didarda SHW
Bhoradu HW
Kesargam HW
Meghpura SHW
Arantava HW
Detal Darbari HW
Morthal SHW
Savarakha SHW
Duva SHW
2 nd Quarter Bhapi Main HW
Didarda SHW
Bhoradu HW
Kesargam HW
Meghpura SHW
Arantava HW
Detal Darbari HW
Morthal SHW
Savarakha SHW
Duva SHW
3rd Quarter Bhapi Main HW
Didarda SHW
Bhoradu HW
Kesargam HW
Meghpura SHW
Arantava HW
Detal Darbari HW
Morthal SHW
Savarakha SHW
Duva SHW
4th Quarter Bhapi Main HW
Didarda SHW
Bhoradu HW
Kesargam HW
Meghpura SHW
Arantava HW
Detal Darbari HW
Morthal SHW
Savarakha SHW
Duva SHW
Item Description
Applying any approve quality of cement paint in three coats incl. cleaning,washing etc. complete for ESR Only. For Existing ESR Incl. Scaffolding. For ESR Only with Scaffolding 1 st Quarter . 8 Lacs at Didarada
0.80 Lacs at Bhoradu
10 Lacs at Kesragam
10 Lacs at Meghpura
12 Lacs at Arantwa
10 Lacs at Detal
5 Lacs at Morthal
6 Lacs at Savarakha
5 Lacs at Duva
2nd Quater 8 Lacs at Didarada
0.80 Lacs at Bhoradu
10 Lacs at Kesragam
10 Lacs at Meghpura
12 Lacs at Arantwa
10 Lacs at Detal
5 Lacs at Morthal
6 Lacs at Savarakha
3rd Quater 8 Lacs at Didarada
0.80 Lacs at Bhoradu
10 Lacs at Kesragam
10 Lacs at Meghpura
12 Lacs at Arantwa
10 Lacs at Detal
5 Lacs at Morthal
6 Lacs at Savarakha
4th Quater 8 Lacs at Didarada
0.80 Lacs at Bhoradu
10 Lacs at Kesragam
10 Lacs at Meghpura
12 Lacs at Arantwa
10 Lacs at Detal
5 Lacs at Morthal
6 Lacs at Savarakha
Supply of Necessary Chemicals for Treatment of Raw Water in Water Treatment plant incl. transportation,carting,loading,unloading etc. Complete.Refilling of Chlorine gas in cylinder incl. transportation to and from factory and back.1 st Year
2nd Tear
3 rd Year
4 th Year
5 th Year
6 th Year
7 th Year
8 th Year
9 th Year
10 th Year
Item Description
Supply of PAC-10percent Solution incl. transportation, loading,unloading etc. complete. 1 st Year
2 nd Year
3 rd Year
4 th Year
5 th Year
6 th Year
7 th Year
8 th Year
9 th Year
10 th Year
Cleaning of storage reservoir:UG sumps, ESR, HGLR/ GLCC and all village level sumps every Year (10 times in the contract period) 1 st Year Bhapi WTP U/G Sump 40 lakh Liter Capacity 1 Nos
5 Lacs Sump at Didarada HW
8 Lacs ESR at Didarada
7 Lacs Sump at Bhordu
0.80 Lacs at Bhoradu
3 Lacs ESR at Bhordu
30 Lacs Sump at Kesragam
10 Lacs Sump at Kesragam
10 Lacs ESR at Kesragam
5 Lacs ESR at Kesragam
25 Lacs Sump at Meghpura
10 Lacs ESR at Meghpura
30 Lacs Sump at Arantava
12 Lacs ESR at Arantwa
25 Lacs at Sump at Darbari Detal
10 Lacs ESR at Darbari Detal
10 Lacs UG Sump at Morthal
5 Lacs ESR at Morthal
12 Lacs UG Sump at Savarakha
6 Lacs ESR at Savarakha
8 Lacs UG Sump at Duva
5 Lacs ESR at Duva
2nd Year Bhapi WTP U/G Sump 40 lakh Liter Capacity 1 Nos
5 Lacs Sump at Didarada HW
8 Lacs ESR at Didarada
7 Lacs Sump at Bhordu
0.80 Lacs at Bhoradu
3 Lacs ESR at Bhordu
30 Lacs Sump at Kesragam
10 Lacs Sump at Kesragam
10 Lacs ESR at Kesragam
5 Lacs ESR at Kesragam
25 Lacs Sump at Meghpura
10 Lacs ESR at Meghpura
30 Lacs Sump at Arantava
12 Lacs ESR at Arantwa
25 Lacs at Sump at Darbari Detal
10 Lacs ESR at Darbari Detal
10 Lacs UG Sump at Morthal
5 Lacs ESR at Morthal
Item Description
12 Lacs UG Sump at Savarakha
6 Lacs ESR at Savarakha
8 Lacs UG Sump at Duva
5 Lacs ESR at Duva
3rd Year Bhapi WTP U/G Sump 40 lakh Liter Capacity 1 Nos
5 Lacs Sump at Didarada HW
8 Lacs ESR at Didarada
7 Lacs Sump at Bhordu
0.80 Lacs at Bhoradu
3 Lacs ESR at Bhordu
30 Lacs Sump at Kesragam
10 Lacs Sump at Kesragam
10 Lacs ESR at Kesragam
5 Lacs ESR at Kesragam
25 Lacs Sump at Meghpura
10 Lacs ESR at Meghpura
30 Lacs Sump at Arantava
12 Lacs ESR at Arantwa
25 Lacs at Sump at Darbari Detal
10 Lacs ESR at Darbari Detal
10 Lacs UG Sump at Morthal
5 Lacs ESR at Morthal
12 Lacs UG Sump at Savarakha
6 Lacs ESR at Savarakha
8 Lacs UG Sump at Duva
5 Lacs ESR at Duva
4th Year Bhapi WTP U/G Sump 40 lakh Liter Capacity 1 Nos
5 Lacs Sump at Didarada HW
8 Lacs ESR at Didarada
7 Lacs Sump at Bhordu
0.80 Lacs at Bhoradu
3 Lacs ESR at Bhordu
30 Lacs Sump at Kesragam
10 Lacs Sump at Kesragam
10 Lacs ESR at Kesragam
5 Lacs ESR at Kesragam
25 Lacs Sump at Meghpura
10 Lacs ESR at Meghpura
30 Lacs Sump at Arantava
12 Lacs ESR at Arantwa
25 Lacs at Sump at Darbari Detal
10 Lacs ESR at Darbari Detal
10 Lacs UG Sump at Morthal
5 Lacs ESR at Morthal
12 Lacs UG Sump at Savarakha
6 Lacs ESR at Savarakha
8 Lacs UG Sump at Duva
5 Lacs ESR at Duva
Item Description
5h Year Bhapi WTP U/G Sump 40 lakh Liter Capacity 1 Nos
5 Lacs Sump at Didarada HW
8 Lacs ESR at Didarada
7 Lacs Sump at Bhordu
0.80 Lacs at Bhoradu
3 Lacs ESR at Bhordu
30 Lacs Sump at Kesragam
10 Lacs Sump at Kesragam
10 Lacs ESR at Kesragam
5 Lacs ESR at Kesragam
25 Lacs Sump at Meghpura
10 Lacs ESR at Meghpura
30 Lacs Sump at Arantava
12 Lacs ESR at Arantwa
25 Lacs at Sump at Darbari Detal
10 Lacs ESR at Darbari Detal
10 Lacs UG Sump at Morthal
5 Lacs ESR at Morthal
12 Lacs UG Sump at Savarakha
6 Lacs ESR at Savarakha
8 Lacs UG Sump at Duva
5 Lacs ESR at Duva
6h Year Bhapi WTP U/G Sump 40 lakh Liter Capacity 1 Nos
5 Lacs Sump at Didarada HW
8 Lacs ESR at Didarada
7 Lacs Sump at Bhordu
0.80 Lacs at Bhoradu
3 Lacs ESR at Bhordu
30 Lacs Sump at Kesragam
10 Lacs Sump at Kesragam
10 Lacs ESR at Kesragam
5 Lacs ESR at Kesragam
25 Lacs Sump at Meghpura
10 Lacs ESR at Meghpura
30 Lacs Sump at Arantava
12 Lacs ESR at Arantwa
25 Lacs at Sump at Darbari Detal
10 Lacs ESR at Darbari Detal
10 Lacs UG Sump at Morthal
5 Lacs ESR at Morthal
12 Lacs UG Sump at Savarakha
6 Lacs ESR at Savarakha
8 Lacs UG Sump at Duva
5 Lacs ESR at Duva
Item Description
7h Year Bhapi WTP U/G Sump 40 lakh Liter Capacity 1 Nos
5 Lacs Sump at Didarada HW
8 Lacs ESR at Didarada
7 Lacs Sump at Bhordu
0.80 Lacs at Bhoradu
3 Lacs ESR at Bhordu
30 Lacs Sump at Kesragam
10 Lacs Sump at Kesragam
10 Lacs ESR at Kesragam
5 Lacs ESR at Kesragam
25 Lacs Sump at Meghpura
10 Lacs ESR at Meghpura
30 Lacs Sump at Arantava
12 Lacs ESR at Arantwa
25 Lacs at Sump at Darbari Detal
10 Lacs ESR at Darbari Detal
10 Lacs UG Sump at Morthal
5 Lacs ESR at Morthal
12 Lacs UG Sump at Savarakha
6 Lacs ESR at Savarakha
8 Lacs UG Sump at Duva
5 Lacs ESR at Duva
8h Year Bhapi WTP U/G Sump 40 lakh Liter Capacity 1 Nos
5 Lacs Sump at Didarada HW
8 Lacs ESR at Didarada
7 Lacs Sump at Bhordu
0.80 Lacs at Bhoradu
3 Lacs ESR at Bhordu
30 Lacs Sump at Kesragam
10 Lacs Sump at Kesragam
10 Lacs ESR at Kesragam
5 Lacs ESR at Kesragam
25 Lacs Sump at Meghpura
10 Lacs ESR at Meghpura
30 Lacs Sump at Arantava
12 Lacs ESR at Arantwa
25 Lacs at Sump at Darbari Detal
10 Lacs ESR at Darbari Detal
10 Lacs UG Sump at Morthal
5 Lacs ESR at Morthal
12 Lacs UG Sump at Savarakha
6 Lacs ESR at Savarakha
8 Lacs UG Sump at Duva
5 Lacs ESR at Duva
Item Description
9h Year Bhapi WTP U/G Sump 40 lakh Liter Capacity 1 Nos
5 Lacs Sump at Didarada HW
8 Lacs ESR at Didarada
7 Lacs Sump at Bhordu
0.80 Lacs at Bhoradu
3 Lacs ESR at Bhordu
30 Lacs Sump at Kesragam
10 Lacs Sump at Kesragam
10 Lacs ESR at Kesragam
5 Lacs ESR at Kesragam
25 Lacs Sump at Meghpura
10 Lacs ESR at Meghpura
30 Lacs Sump at Arantava
12 Lacs ESR at Arantwa
25 Lacs at Sump at Darbari Detal
10 Lacs ESR at Darbari Detal
10 Lacs UG Sump at Morthal
5 Lacs ESR at Morthal
12 Lacs UG Sump at Savarakha
6 Lacs ESR at Savarakha
8 Lacs UG Sump at Duva
5 Lacs ESR at Duva
10h Year Bhapi WTP U/G Sump 40 lakh Liter Capacity 1 Nos
5 Lacs Sump at Didarada HW
8 Lacs ESR at Didarada
7 Lacs Sump at Bhordu
0.80 Lacs at Bhoradu
3 Lacs ESR at Bhordu
30 Lacs Sump at Kesragam
10 Lacs Sump at Kesragam
10 Lacs ESR at Kesragam
5 Lacs ESR at Kesragam
25 Lacs Sump at Meghpura
10 Lacs ESR at Meghpura
30 Lacs Sump at Arantava
12 Lacs ESR at Arantwa
25 Lacs at Sump at Darbari Detal
10 Lacs ESR at Darbari Detal
10 Lacs UG Sump at Morthal
5 Lacs ESR at Morthal
12 Lacs UG Sump at Savarakha
6 Lacs ESR at Savarakha
8 Lacs UG Sump at Duva
5 Lacs ESR at Duva
Procurement & replacement of filter media: Effective size of filter sand 0.45 to 0.70 mm uniformity coefficient not more than 1.7 nor less than 1.3, depth of filter 0.75 M, freeboard 50 cm , gravel 0.45 M in depth, sand and gravel conforming to IS: 8491(i)-77 1 st Quarter at Bhapi WTP
2nd Quarter
3rd Quarter
4th Quarter
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Document
01.2_Volume-IB GCC Final.pdf
02.1_Volume-IIA Extent of work Final.pdf
02.2_Volume_IIB Tech Spec Civil Final -East.pdf
02.3 _Volume_IIB -2 R and B General Specification.pdf
Document
02.5_Vol_IIC-2 Tech Spec Elect.pdf
02.6_Vol_IID Data Sheet-M E and I.pdf
02.7_Volume_IID Data Sheet - Civil.pdf
02.8_Volume V O and M-1.pdf
03.0 Volume-III Price bid_East.pdf
04.0_Volume IV Drawings.pdf
5.3 Specification Horticlture.pdf
2-Augm_East Zone Drawing.pdf
6.0 100 SQ.MT.pdf
08_GST GR.pdf
09_INTEGRITY PACT_P_387.pdf
10_Vendor list_Pg_388.pdf
11_1.2_Royelty_18.06.19_New rate.pdf
12_04_Ann 4.pdf
13_4_Vigilace Unit-min.pdf
14_05_Ann 5 Purchase Policy.pdf
15_06_Any-6A_Labour Circular.pdf
16_6_Mecilianius-min.pdf
17_07_Ann 6B shramyogi GR.pdf
18_7_GR LD Deduction 10-1-2018.pdf
20_8_Circular_26_SIGN BOARD.pdf
21_13_GR- PART - 1_01 to 11.pdf
24_DMO_2859_01-05-2025_SD EMD GR _2025-26 (1).pdf
25_Min wages Circular.pdf
Badhakam Shramyogi.PDF
Deposit Release Circular.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .